Minimizing beneficiation wastewater through internal reuse of process water in flotation circuit
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Here, the plane-stress assumption can be challenging to support in a finite element program because it traditionally requires separate implementations of constitutive models than those intended for three-dimensional or two-dimensional plane-strain simulations. As a solution to this issue, this paper presents a method to solve the plane-stress problem using a mixed formulation. In this formulation, the out-of-plane strain is treated as a field variable that is solved for in addition to the standard in-plane displacement variables, in a manner that weakly enforces the condition that the out-of-plane stress is zero. The proposed formulation is non-intrusive, requiring no modifications to the constitutive models in contrast to the conventional plane-stress formulation. The proposed mixed formulation has been benchmarked against analytical solutions and numerical solutions, with good performance and accuracy.
Not Available
Not Available
Not Available
This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water (FPW) from hydraulic fracturing and oil production operations. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe 3+ coagulating agent, and the base is used to neutralize the treated water. The costs for generating the ferric iron coagulant were determined as a function of current density and feed water salinity. The process was shown to be effective for removing colloidal bentonite particles from brine solutions. Here, the process has several advantages over conventional electrocoagulation using iron anodes, including: the ability to treat anoxic waters, elimination of electrode fouling, lower cost for the coagulant, and the ability to deliver Fe 3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen required to oxidize ferrous to ferric iron.
Not Available
Abstract not provided.
We develop a model showing how reflection from both the front and back contacts of thermophotovoltaic (TPV) cells affects the system efficiency. From this foundation we determine the design rules for front grids for TPV cells, and assess the consequences of those rules on cell design and system performance. We show that these design rules are different and more complex than the corresponding design rules for solar photovoltaic (PV) cells, and can lead to substantially different grid design and system performance than if the simpler solar PV design rules were used.
ABSTRACT Campylobacterinfections are a leading cause of bacterial diarrhea in humans globally. Infections are due to consumption of contaminated food products and are highly associated with chicken meat, with chickens being an important reservoir forCampylobacter. Here, we characterized the genetic diversity ofCampylobacter jejuni(C. jejuni) andCampylobacter coli(C. coli) detected in broiler chicken litter over three consecutive flocks and determined their antimicrobial resistance (ARM) and virulence factor (VF) profiles.Campylobacterwas detected in 9.38% (27/288) of litter samples collected. Antimicrobial susceptibility testing and whole genome sequencing were performed onC. jejuni(n= 39) andC. coli(n= 5) isolates.Campylobactervirulence factors differed within and across broiler houses but were explained by the broiler flock cohort raised on litter,Campylobacterspecies andCampylobactermultilocus sequence type (MLST). Virulence factors involved in the ability to invade and colonize host tissues and evade host defenses were present inC. jejuniisolates (ST-464) from flock cohorts 1 and 2 but absent inC. jejuniisolates (ST-48) from flock cohort 3.C. jejuniisolates from house three harbored a significantly higher proportion of virulence genes with functions related to glycosylation and immune evasion thanC. jejuniisolates from houses 1 and 2 (P< 0.01). AllC. jejuniisolates were susceptible to all antibiotics tested whileC. coli(n= 4) were resistant to tetracycline and harbored the tetracycline resistant ribosomal protection protein (TetO). Our results suggest that house environment and broiler management practices imposed selective pressures on virulence factors and antimicrobial resistance genes ofCampylobacter. IMPORTANCE Campylobacteris a leading cause of foodborne illness in the United States due to consumption of contaminated or mishandled food products, often associated with chicken meat.Campylobacteris common in the microbiota of avian and mammalian gut; however, acquisition of antimicrobial resistance genes (ARGs) and virulence factors (VFs) may result in strains that pose significant threat to public health. Although there are studies investigating the genetic diversity ofCampylobacterstrains isolated from post-harvest chicken samples, there are limited data on the genome characteristics of isolates recovered from preharvest broiler production. Here, we show thatCampylobacter jejuniandCampylobacter colidiffer in their carriage of antimicrobial resistance and virulence factors may also differ in their ability to persist in litter during consecutive grow-out of broiler flocks. We found that presence/absence of virulence factors needed for evasion of host defense mechanisms and gut colonization played an integral role in differentiatingCampylobacterstrains.
Searches for new physics at the Large Hadron Collider have constrained many models of physics beyond the Standard Model. Many searches also provide resources that allow them to be reinterpreted in the context of other models. We describe a reinterpretation pipeline that examines previously untested models of new physics using supplementary information from ATLAS Supersymmetry (SUSY) searches in a way that provides accurate constraints even for models that differ meaningfully from the benchmark models of the original analysis. The public analysis information, such as public analysis routines and serialized probability models, is combined with common event generation and simulation toolkits MADGRAPH, PYTHIA8, and DELPHES into workflows steered by TOML configuration files, and bundled into the mapyde Python package. The use of mapyde is demonstrated by constraining previously untested SUSY models with compressed sleptons and electroweakinos using ATLAS results.
The goal of this final project report is to summarize the work conducted on project DE-FE0031555. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed a hybrid electrochemical-membrane technology for treating wet flue gas desulfurization (WFGD) blowdown from coal-fired power generation plants that (1) removes government-regulated species and total suspended solids (TSS) via electrocoagulation with solid/liquid separation to avoid further treatments by a biological method specifically for selenium, and (2) reduces total dissolved solids (TDS) in a nanofiltration unit to promote water recycle and reduce freshwater intake. Additional technological configurations were pursued, including (1) nanofiltration combined with zeolite dewatering for a near-zero liquid discharge (ZLD) scenario, and (2) polishing discharge from zeolite dewatering using capacitive deionization (CDI) with 90+% salt rejection to produce water with less than 100ppm TDS for more beneficial use. Project results verified that UK CAER’s hybrid approach addressed the complexities of WFGD blowdown with simplified unit operation at relatively low capital investment by demonstrating: (1) an effective in-situ generated solid sorbent material, green-rust (GR), that specifically removes regulated dissolved species in WFGD blowdown, including selenium, arsenic, and nitrates; (2) a low-cost, high flux nanofiltration treatment that removes both monovalent and divalent species at >80% rejection to adequately provide water recycle and extend the life of FGD equipment by mitigating chloride aided pitting corrosion mechanisms; and (3) a solidification and stabilization process using pozzolanic agents that retain regulated species and satisfy the Resource Conservation and Recovery Act (RCRA) leachate requirements. UK CAER proved electrocoagulation with GR to be an intensified solution for effluent limit guidelines (ELG), and based on preliminary techno-economic analysis (TEA), in comparison to DOE’s Case 1 for Biological Wastewater Treatment that had a purchased equipment cost (PEC) of $\$$5.26 million and a Total plant cost (TPC) of $\$$30.0 million, the EC process had a PEC of $\$$2.67 million and the TPC of $\$$17.0 million. While the electricity consumption for Case 1 was 53 kW, it was 110 kW for the EC process due to dissolving iron for a three-stage reaction design. However, electricity consumption for the EC process could be significantly reduced by adopting a counter-current reactor design for at least a 6-stage chemical reaction operation.