Search NASA⌕ Search

SEARCH · Search NASA

Results for “and lower operating pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ramjet bypass duct and preburner configuration

A combined turbofan and ramjet aircraft engine includes a forward bypass duct which allows the engine to operate more efficiently during the turbofan mode of operation. By mounting a ramjet preburner in the forward duct and isolating this duct from the turbofan bypass air, a transition from turbofan operation to ramjet operation can take place at lower flight Mach numbers without incurring pressure losses or blockage in the turbofan bypass air.

Orlando, Robert J.↗

Altitude-Wind-Tunnel Investigation of the 19B-2, 19B-8 and 19XB-1 Jet- Propulsion Engines: Analysis of Compressor Performance - 4

Investigations were conducted in the Cleveland altitude wind tunnel to determine the performance and operational characteristics of the 19B-2, 19B-8, and 19XS-1 turbojet engines. One objective was to determine the effect of altitude, flight Mach number, and tail-pipe-nozzle area on the performance characteristics of the six-stage and ten-stage axial-flow compressors of the 19B-8 and 19XB-1 engines, respectively, The data were obtained over a range of simulated altitudes and flight Mach numbers. At each simulated flight condition the engine was run over its full operable range of speeds. Performance characteristics of the 19B-8 and 19XB-1 compressors for the range of operation obtainable in the turboJet-engine installation are presented. Compressor characteristics are presented as functions of air flow corrected to sea-level conditions, compressor Mach number, and compressor load coefficient. For the range of compressor operation investigated, changes in Reynolds number had no measurable effect on the relations among compressor Mach number, corrected air flow, compressor load coefficient, compressor pressure ratio, and compressor efficiency. The operating lines for the 19B-8 compressor lay on the low-air-flow side of the region of maximum compressor efficiency; the 19B-8 compressor operated at higher average pressure coefficients per stage and produced a lower over-all pressure ratio than did the 19XB-1 compressor.

Dietz, Robert O.↗

Dual-Compartment Inflatable Suitlock

There is a need for an improvement over current NASA Extravehicular Activity (EVA) technology. The technology must allow the capacity for quicker, more efficient egress/ingress, allow for shirtsleeve suit maintenance, be compact in transport, and be applicable to environments ranging from planetary surface (partial-g) to orbital or deep space zero-g environments. The technology must also be resistant to dust and other foreign contaminants that may be present on or around a planetary surface. The technology should be portable, and be capable of docking with a variety of habitats, ports, stations, vehicles, and other pressurized modules. The Dual-Compartment Inflatable Suitlock (DCIS) consists of three hard inline bulkheads, separating two cylindrical membrane-walled compartments. The Inner Bulkhead can be fitted with a variety of hatch types, docking flanges, and mating hardware, such as the Common Berthing Mechanism (CBM), for the purpose of mating with vehicles, habitats, and other pressurized modules. The Inner Bulkhead and Center Bulkhead function as the end walls of the Inner Compartment, which during operations, would stay pressurized, either matching the pressure of the habitat or acting as a lower-pressure transitional volume. The Inner Compartment contains donning/doffing fixtures and inner suit-port hatches. The Center Bulkhead has two integrated suit-ports along with a maintenance hatch. The Center Bulkhead and Outer Bulkhead function as the end walls of the Outer Compartment, which stays at vacuum during normal operations. This allows the crewmember to quickly don a suit, and egress the suitlock without waiting for the Outer Compartment to depressurize. The Outer Compartment can be pressurized infrequently for both nominal and off-nominal suit maintenance tasks, allowing shirtsleeve inspections and maintenance/repair of the environmental suits. The Outer Bulkhead has a pressure-assisted hatch door that stays open and stowed during EVA operations, but can be closed for environmental protection of the suits, suit maintenance, and pressurization.

Kennedy, Kriss J.↗

A parametric study of single-wall carbon nanotube growth by laser ablation

Results of a parametric study of carbon nanotube production by the double-pulse laser oven process are presented. The effect of various operating parameters on the production of single-wall carbon nanotubes (SWCNTs) is estimated by characterizing the nanotube material using analytical techniques, including scanning electron microscopy, transmission electron microscopy, thermo gravimetric analysis and Raman spectroscopy. The study included changing the sequence of the laser pulses, laser energy, pulse separation, type of buffer gas used, operating pressure, flow rate, inner tube diameter, as well as its material, and oven temperature. It was found that the material quality and quantity improve with deviation from normal operation parameters such as laser energy density higher than 1.5 J/cm2, pressure lower than 67 kPa, and flow rates higher than 100 sccm. Use of helium produced mainly small diameter tubes and a lower yield. The diameter of SWCNTs decreases with decreasing oven temperature and lower flow rates.

Nanotubes, Carbon/chemistry↗

Design and Study of a LOX/GH2 Throttleable Swirl Injector for Rocket Applications

A LOX/GH2 swirl injector was designed for a 10:1 propellant throttling range. To accomplish this, a dual LOX manifold was used feeding a single common vortex chamber of the swirl element. Hot-fire experiments were conducted for rocket chamber pressures from 80 to 800 psia at a mixture ratio of nominally 6.0 using steady flow, single-point-per-firing cases as well as dynamic throttling conditions. Low frequency (mean) and high frequency (fluctuating) pressure transducer data, flow meter measurements, and Raman spectroscopy images for mixing information were obtained. The injector design, experimental setup, low frequency pressure data, and injector performance analysis are presented. C* efficiency was very high (approx. 100%) at the middle of the throttleable range with somewhat lower performance at the high and low ends. From the analysis of discreet steady state operating conditions, injector pressure drop was slightly higher than predicted with an inviscid analysis, but otherwise agreed well across the design throttling range. Dynamic throttling of this injector was attempted with marginal success due to the immaturity of the throttling control system. Although the targeted mixture ratio of 6.0 was not maintained throughout the dynamic throttling profile, the injector behaved well over the wide range of conditions.

Greene, Christopher↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy is required. a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point. the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating, boil-off losses.

Flachbart, Robin H.↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.

Flachbart, Robin H.↗

Radio frequency studies in the NASA Lewis Bumpy Torus

The fluctuations in potential of the plasma in the NASA Lewis Bumpy Torus are observed using capacitive probes over frequencies from 1 kHz to 25 MHz and a wide range of operating conditions. The spectra are found to differ greatly above and below a background gas pressure of .000034 torr deuterium. Above this pressure, the spectrum is dominated by the ion spoke frequency and a spectral index may be defined. Below this pressure, the spectrum below 200 kHz is lower in amplitude by a factor of ten and no spectral index can be defined. At these lower pressures, fluctuations appearing to be ion spokes are observed, but have a dependence of frequency on operating conditions which is previously unreported.

Gerdin, G. A.↗

Performance Comparison of Helium and sCO 2 as Coolants for Modular Finger-Type Divertors

Several studies at the Georgia Institute of Technology have evaluated the thermal and fluids performance of the helium-cooled modular divertor with multiple jets (HEMJ) over the past decade. This finger-type divertor was studied both experimentally at nearly prototypical conditions and numerically at fully prototypical operating conditions using experimentally validated simulations. Recently, supercritical carbon dioxide (sCO 2 ) has been studied as the primary coolant in power cycles and other applications in various systems, in part because CO 2 achieves the high densities typical of supercritical fluids at relatively low temperatures and pressures, with a critical point of (7.38 MPa, 31°C). This density makes it possible to realize very compact and efficient sCO 2 power cycles. The feasibility of sCO 2 as a coolant for plasma-facing components, specifically the divertor, was therefore evaluated as part of the Fusion Energy System Studies design study activities. This work compares the thermal-fluid performance of helium and sCO 2 in the HEMJ divertor geometry using numerical simulations at prototypical conditions: inlet temperatures T i = 600°C to 700°C, pressures p ≈ 10 MPa, and steady-state incident heat fluxes on the tile q″ < 17 MW/m 2 . The performance is quantified here as the maximum heat flux that can be accommodated by the plasma-facing tile, the pumping power fraction, defined as the ratio of the coolant pumping power to the incident thermal power, and the operating stress limits based on ASME pressure vessel criteria. As expected, helium requires lower mass flow rates and pumping power fractions within imposed maximum temperature limits for the HEMJ pressure boundary. However, it also appears that neither helium nor sCO 2 can remove 10 MW/m 2 of incident heat flux while meeting ASME pressure vessel criteria. Finally, the numerical modeling reveals that sCO 2 may remove slightly higher incident heat fluxes than helium due to the imposed stress limits due to the sCO 2 coolant resulting in smaller local temperature gradients, albeit at a considerably higher pumping power fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Integration of a Stochastic Clad Damage Propagation Model into PRONGHORN-SC Subchannel Analysis Code

The failure of fuel pins in nuclear reactors is intrinsically stochastic. Typically, a combination of variation in manufacturing that affects the material characteristics and the fuel assembly dimensions, variation in operating conditions, such as local power, coolant flow rate, and irradiation induced changes in material properties lead to a large uncertainty in failure margin of the fuel pins. Failure, therefore, may occur in exceptional pins with adverse combinations of these variations. Upon a metal fuel pin (U-Pu-Zr/HT9) failure, depressurization of the fuel pin takes place by release of fission gas, liquid sodium bond, and potentially solid fuel particles or molten/eutectic fuel droplets through the hole in cladding. The effect of a fission gas jet on neighbor fuel pins and possible propagation of a clad damage during normal operation was studied experimentally in 1970s and it was found that the post-failure fission gas jet insulates the jet impingement area of the target fuel pin surface and could increase the target pin’s surface temperature by as much as 100 – 200 K during the failed pin depressurization. It was concluded that the effect should not lead to fuel pin failure propagation during normal operation. In accident scenarios of sodium and lead fast reactors such as Unprotected Loss-Of-Flow (ULOF) or Unprotected Transient Over Power (UTOP), the fuel pins can be subjected to higher clad temperatures and fuel pin pressures or fuel clad mechanical/chemical interaction where thermal creep margin becomes significantly lower compared to the normal operation conditions. Therefore, possible stochastic failure and the post-failure fission gas/fuel jet impingement could be critical in order to predict fuel pin failure propagation. Pin depressurization due to fission gas release may degrade the heat transfer by formation of a gas blanket on a neighboring pin surface, which is a local phenomenon, and by causing coolant flow deceleration and starvation, which could affect a surrounding region as well. Furthermore, the potential presence of solid fuel particles or molten fuel at the time of clad failure could boost post-failure jet induced degradation even further. The present study models the U-Pu-Zr/HT9 metal fuel pin failure and stochastic clad damage propagation by biased sampling based on a Cumulative Damage Fraction (CDF) type clad failure criterion and the normal distribution of fuel failure probability density as a function of logarithm of Cumulative Damage Fraction. In addition, the effect of post-failure fission gas jet on heat transfer degradation is modeled for the target pins. This model is called stochastic Clad Damage Propagation (CDAP). The CDAP model is now fully integrated into developmental version of PRONGHORN-SC subchannel analysis code, allowing for modeling local failures and its propagation potential. Section 2 describes the components of the CDAP models. Section 3 describes the model implementation to PRONGHORN-SC and input specifications. Section 4 describes the CDAP model validation coupled to PRONGHORN-SC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surfactant-assisted coal liquefaction

Improved process of coal liquefaction utilizing nonaqueous surfactant has increased oil yield from 50 to about 80%. Asphaltene molecule formation of colloid particles is prevented by surfactant. Separated molecules present more surface area for hydrogenation reaction. Lower requirements for temperature, pressure, and hydrogen lead to reduction in capital and operation costs.

Hsu, G. C.↗

Altitude performance of a low-noise-technology fan in a turbofan engine with and without a sound suppressing nacelle

Test variables were inlet Reynolds number index (0.2 to 0.5), flight Mach number (0.2 to 0.8), and flow distortion (tip radial and combined circumferential - tip radial patterns). Results are limited to fan bypass and overall engine performance. There were no discernible effects of Reynolds number on fan performance. Increasing flight Mach number shifted the fan operating line such that pressure ratio decreased and airflow increased. Inlet flow distortion lowered stall margin. For a Reynolds number index of 0.2 and flight Mach number of 0.54, the sound suppressing nacelle lowered fan efficiency three points and increased specific fuel consumption about 10 percent.

Biesiadny, T. J.↗

Design and Study of a LOX/GH2 Throttleable Swirl Injector for Rocket Applications

A LOX/GH2 swirl injector was designed for a 10:1 propellant throttling range. To accomplish this, a dual LOX (liquid oxygen) manifold was used feeding a single common vortex chamber of the swirl element. Hot-fire experiments were conducting for rocket chamber pressures from 80 to 800 psia at a mixture ratio of nominally 6.0 using steady flow, single-point-per-firing cases as well as dynamic throttling conditions. Low frequency (mean) and high frequency (fluctuating) pressure transducer data, flow meter measurements, and Raman spectroscopy images for mixing information were obtained. The injector design, experimental setup, low frequency pressure data, and injector performance analysis will be presented. C efficiency was very high (approximately 100%) at the middle of the throttle-able range with somewhat lower performance at the high and low ends. From the analysis of discreet steady state operating conditions, injector pressure drop was slightly higher than predicted with an inviscid analysis, but otherwise agreed well across the design throttling range. Analysis of the dynamic throttling data indicates that the injector may experience transient conditions that effect pressure drop and performance when compared to steady state results.

Greene, Christopher↗

Mars Flyer Rocket Propulsion Risk Assessment: ARC Testing

This report describes the investigation of a 10-N, bipropellant thruster, operating at -40 C, with monomethy1hydrazine (MMH) and 25% nitric oxide in nitrogen tetroxide (MON-25). The thruster testing was conducted as part of a risk reduction activity for the Mars Flyer, a proposed mission to fly a miniature airplane in the Martian atmosphere. Testing was conducted using an existing thruster, designed for MMH and MON-3 propellants. MON-25 oxidizer was successfully manufactured from MON-3 by the addition of nitric oxide. The thruster was operated successfully over a range of propellant temperatures (-40 to 21 C and feed pressures (6.9 to 20.7 kPa). The thruster hardware was always equal or lower than the propellant temperature. Most tests were 30- and 60-second durations, with 600- and 1200-second duration and pulse testing also conducted. When operating at -40 C, the mixture ratio of the thruster shifted from the nominal value of 1.65 to about 1.85, probably caused by an increase in MMH viscosity, with a corresponding reduction in MMH flowrate. Specific impulse at - 40 C (at nominal feed pressures) was 267 sec, while performance was 277 sec at 21 C. This difference in performance was due, in part, to the mixture ratio shift.

Source record↗

Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radio frequency studies in the NASA Lewis Bumay Torus

The fluctuations in potential of the plasma in the NASA Lewis Bumpy Torus were observed using capacitive probes over frequencies from 1 kHz to 25 MHz and a wide range of operating conditions. The spectra were found to differ greatly above and below a background gas pressure of 3.0.000034 torr deuterium. Above this pressure the spectrum was dominated by the ion spoke frequency and a spectral index was defined. Below this pressure the spectrum below 200 kHz was lower in lower in amplitude by a factor of ten and no spectral index could be defined. At these lower pressures, fluctuations that appeared to be ion spokes were observed, but had a dependence of frequency on operating conditions which was previously unreported.

Gerdin, G. A.↗

New circumferential seal design concept using self-acting lift geometries

Seal operating temperatures, leakage (pressurizing gas flow), torque, and wear of a conventional circumferential shaft seal were measured and compared to those of a conventional seal modified to have self-acting lift geometries. Both seal types had a 2.625-in diameter bore and were operated at a sliding velocity of 150 ft/sec with differential pressures ranging from 0 to 100 psi. Results of this investigation show that the self-acting seal operated at lower bulk carbon temperatures with half the torque and approximately one-tenth the wear of the conventional seal. Seal leakage of the self-acting seal was of order of 0.04 scfm for pressures above 60 psi which is well within the accepted range for gas turbine engine applications.

Hady, W. F.↗

Experimental Combustion and Flame Characterization of a Chemical Looping-Based Oxidative Dehydrogenation Byproduct Fuel Mixture Containing High CO2 Dilution

Abstract This study investigates the combustion performance of a CO2-rich fuel mixture containing ethane and methane as active species using a constant volume combustion chamber. This fuel is obtained as a byproduct of a chemical looping-based oxidative dehydrogenation (Cl-ODH) process ethylene production. The byproduct gas mixture has 40.79% CO2, 39.49% ethane, and 4.88% methane by weight with other minor compounds. Using this fuel for energy extraction would improve the process efficiency of the ethane to ethylene conversion. After initial combustion modeling, the gas fuel mixture was reduced to just the major species: CO2, ethane, and methane. The mixture was then tested for flammability limits and combustion performance under spark-ignition conditions. Effects of ambient conditions like temperatures between 300 and 400 K with initial pressures from 1 to 10 bar were tested. The effects of stoichiometry were tested to understand flame velocities and heat release. The fuel mixture showed an overall reduced flame velocity compared to gasoline. Instability in combustion was believed to be caused by the dissociation of ethane under elevated conditions. At higher pressures, the flame produces lower cumulative heat release. Simulations were also performed using a model tuned to replicate the operations of the combustion chamber used in the experiments. Heat release and unburnt fuel mass data were calculated to identify the discrepancies in the combustion completeness at elevated pressures. The effects of CO2 quenching the flame coupled with the increased dissociation of the fuel species can lead to up to more than 75% of the fuel mixture being unburnt. Data from this study were used to modify a small-scale spark-ignition engine to use this fuel and produce usable energy.

Energy & Fuels↗