Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam independence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Adaptive autoencoder latent space tuning for more robust machine learning beyond the training set for six-dimensional phase space diagnostics of a time-varying ultrafast electron-diffraction compact accelerator

In this work, we present a general adaptive latent space tuning approach for improving the robustness of machine learning tools with respect to time variation and distribution shift. We demonstrate our approach by developing an encoder-decoder convolutional neural network-based virtual 6D phase space diagnostic of charged particle beams in the HiRES ultrafast electron diffraction (UED) compact particle accelerator with uncertainty quantification. Our method utilizes model-independent adaptive feedback to tune a low dimensional 2D latent space representation of ~1 million dimensional objects which are the 15 unique 2D projections (x, y),...,(z, p z ) of the 6D phase space (x, y, z, p x , p y , p z ) of the charged particle beams. We demonstrate our method with numerical studies of short electron bunches utilizing experimentally measured UED input beam distributions.

43 PARTICLE ACCELERATORS↗

Expected sensitivity of the Light Dark Matter eXperiment to long-lived dark photons and axion-like particles

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment primarily designed to achieve world-leading, model-independent sensitivity to sub-GeV dark matter particles. LDMX aims to identify dark sector particle production through the detection of events with substantial missing energy and momentum, a signature of invisible particles escaping detection. Beyond this primary objective, LDMX offers a complementary search strategy for long-lived, visibly decaying particles, such as dark photons and axion-like particles. We present the first detailed evaluation of the ability of LDMX to identify visibly decaying, long-lived particles that couple to electrons using a detailed simulation, based on the Geant 4-toolkit, that incorporates realistic detection efficiencies and background levels. We demonstrate that LDMX can achieve a sensitivity that is competitive with other experiments that are currently running. The models explored in this paper are distinct and complementary to those probed in the LDMX flagship missing-momentum analysis. Through searching for both invisible dark matter and visibly decaying long-lived signatures, LDMX will significantly advance the search for light dark matter and provide a broad exploration of the sub-GeV dark sector.[graphic not available: see fulltext]

Akesson, Torsten [Lund U.] (ORCID:0000000341415408↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Impact of the optical parametric amplification phase on laser pulse compression

Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system’s spectral and spatial phases are required for Fourier transform–limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. Here, we show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate (DKDP) amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

47 OTHER INSTRUMENTATION↗

Observation of Polarization-Dependent Changes in Higher-Order Mode Responses as a Function of Transverse Beam Position in Tesla-Type Cavities at FAST

Higher-order modes (HOMs) in superconducting rf cavities present problems for an electron bunch traversing the cavity in the form of long-range wakefields from previous bunches. These may dilute the emittance of the macropulse average, especially with low emittance beams at facilities such as the European X-ray Free-electron Laser (XFEL) and the upgraded Linac Coherent Light Source (LCLS-II). Here we present observations of HOMs driven by the beam at the Fermilab Accelerator Science and Technology (FAST) facility. The FAST facility features two independent TESLA-type cavities (CC1 and CC2) after a photocathode rf gun followed by an 8-cavity cryomodule. The HOM signals were acquired from cavities using bandpass filters of 1.75 ± 0.15 GHz, 2.5 ± 0.2 GHz, and 3.25 ± 0.2 GHz and recorded using an 8-GHz, 20 GSa/s oscilloscope. The frequency resolution obtained is sufficient to separate polarization components of many of the HOMs. These HOM signals were captured from CC1 and cavities 1 and 8 of the cryomodule for various initial trajectories through the cavities, and we observe correlations between trajectory, HOM signals, and which polarization component of a mode is affected.

Thurman-Keup, Randy Michael↗

High-sensitivity gas-mapping 3D imager and method of operation

Measurement apparatuses and methods are disclosed for generating high-precision and -accuracy gas concentration maps that can be overlaid with 3D topographic images by rapidly scanning one or several modulated laser beams with a spatially-encoded transmitter over a scene to build-up imagery. Independent measurements of the topographic target distance and path-integrated gas concentration are combined to yield a map of the path-averaged concentration between the sensor and each point in the image. This type of image is particularly useful for finding localized regions of elevated (or anomalous) gas concentration making it ideal for large-area leak detection and quantification applications including: oil and gas pipeline monitoring, chemical processing facility monitoring, and environmental monitoring.

Kreitinger, Aaron Thomas↗

High-sensitivity multi-channel atomic magnetometer

High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.

Kim, Young Jin↗

High-sensitivity gas-mapping 3D imager and method of operation

Measurement apparatuses and methods are disclosed for generating high-precision and -accuracy gas concentration maps that can be overlaid with 3D topographic images by rapidly scanning one or several modulated laser beams with a spatially-encoded transmitter over a scene to build-up imagery. Independent measurements of the topographic target distance and path-integrated gas concentration are combined to yield a map of the path-averaged concentration between the sensor and each point in the image. This type of image is particularly useful for finding localized regions of elevated (or anomalous) gas concentration making it ideal for large-area leak detection and quantification applications including: oil and gas pipeline monitoring, chemical processing facility monitoring, and environmental monitoring.

Kreitinger, Aaron Thomas↗

Photoproduction of K 0 S Pairs at GlueX

We present an study of the ¿¿ ¿ ¿0 ¿¿0 ¿¿ channel measured by the GlueX experiment. This channel selects for resonances with ¿¿¿ = even++ quantum numbers (the ¿0, ¿2, ¿0, and ¿2 light, flavorless mesons) and potentially contains contributions from the lightest scalar glueball (¿0). Data from the 2017, 2018, and 2020 run periods are used to perform a mass independent (binned) partial-wave analysis to distinguish spin states. Due to the polarized photon beam at GlueX, we are also able to extract reflectivity amplitudes for the first time in this channel. Additionally, we perform mass-dependent partial-wave analyses using a fixed ¿-matrixparameterization to attempt a determination of the relative contribution of each res onance, and we present a guided initialization method which facilitates navigation through a parameter space with many local minima. These mass-dependent fits are a proof-of-concept in using fixed ¿-matrix models constrained by other experiments to measure photoproduc tion amplitudes for overlapping states which may only differ by isospin, a property which cannot be distinguished in this channel.

Hoffman, Nathaniel [Carnegie Mellon University]↗

3D small-gain formula allowing strong focusing and harmonic lasing for a ring-based x-ray free electron laser oscillator

We present a detailed derivation of a formula for the small-gain calculation for an x-ray free electron laser oscillator (XFELO) based on a medium-energy (3–4 GeV) storage ring. We found harmonic lasing and strong focusing are essential for this beam energy range. Taking the small-signal low-gain formula developed by Kim and his colleagues, we modified it in such a way that the gain can be calculated without the “no focusing approximation,” and a strong focusing can be applied, as well as harmonic lasing. In this formula, the gain is represented as a product of two factors with one of them depending only on the harmonic number, undulator period, and gap. Using this factor, we show that it is favorable to use harmonic lasing to achieve hard x-ray FEL working in the small-signal low-gain regime with the medium-energy electron beam. Our formula also allows FEL optimization by varying the vertical gradient of the undulator, the vertical dispersion, and the horizontal and vertical focusing, independently. As an example, we applied this formula to study the feasibility of an XFELO option for the National Synchrotron Light Source II (NSLS-II) upgrade. Since a quite high peak current is required for the FEL, collective effects of beam dynamics in medium-energy synchrotrons significantly affect the electron beam parameters. We carried out a multiparameter optimization taking collective effects into account. Note, even though our example is for a ring-based XFELO at 3 to 4 GeV, the formula and, in particular, the approach developed here may be applied to other types of FELs. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Design of Electrostatic Aberration Correctors for Scanning Transmission Electron Microscopy

Abstract In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular beam epitaxy growth and characterization of GePb alloys

Pb based group-IV alloys such as GePb have been gaining interest as a potential alternative for infrared detectors, quantum materials, and high-speed electronic devices. Challenges remain in their growth due to the extremely low solid solubility of Pb in the Ge–Pb system. This paper reports molecular beam epitaxy growth of GePb alloy thin films on Ge(100) substrates. Effusion cells of Ge and Pb are used to control the flux ratio independently. The optimal substrate temperature is found to be near the thermocouple temperature of 300 °C based on the characterization of the grown films using high-resolution x-ray diffraction. A large change in the Ge:Pb beam equivalent pressure ratio from 10:1 to 1:1 results in only a minimal increase of the Pb composition from 0.74% to 2.84% as estimated from Raman spectroscopy and Rutherford backscattering spectrometry. Furthermore, scanning electron microscopy images show a large volume of Pb islands on the surface that form into either long trapezoidal rods or uniform droplets, with increasing Pb flux and growth time the density of Pb islands increased.

36 MATERIALS SCIENCE↗

Heisenberg-limited Hamiltonian learning for interacting bosons

We develop a protocol for learning a class of interacting bosonic Hamiltonians from dynamics with Heisenberg-limited scaling. For Hamiltonians with an underlying bounded-degree graph structure, we can learn all parameters with root mean square error ϵ using ${\mathcal{O}}(1/\epsilon )$ total evolution time, which is independent of the system size, in a way that is robust against state-preparation and measurement error. In the protocol, we only use bosonic coherent states, beam splitters, phase shifters, and homodyne measurements, which are easy to implement on many experimental platforms. A key technique we develop is to apply random unitaries to enforce symmetry in the effective Hamiltonian, which may be of independent interest.

computer science↗

Toroidal modeling of runaway electron loss due to 3-D fields in DIII-D and COMPASS

The 3-D field induced relativistic runaway electron (RE) loss has been simulated for DIII-D, COMPASS and ITER plasmas, utilizing the MARS-F code incorporated with the recently developed and updated RE orbit module (REORBIT). Modeling shows effectively 100% loss of a post-disruption, high-current runaway beam in DIII-D, due to the 1 kG level of magnetic field perturbation produced by a fast growing n = 1 resistive kink instability. The RE loss is shown to be independent of the particle energy or the initial location of particles in the configuration space. Applied resonant magnetic perturbation (RMP) fields from in-vessel coils are not effective for RE beam mitigation in DIII-D, but do produce finite (>10%) RE loss in COMPASS, consistent with experimental observations in above two devices. The major reasons for this difference in RE control by RMP between these two devices are (i) the coil proximity to the RE beam and (ii) the effective coil current scaling versus the machine size and the toroidal magnetic field. About 10% RE loss fraction is also predicted for an ITER 15 MA scenario with pre-disruption plasma, highlighting the role of the plasma response. Up to 30% loss is computed, however, by artificially scaling the equilibrium pressure to zero. This is due to the more resistive plasma response and stronger resulting field line stochasticity. Distributions of the lost REs to the limiting surface show poloidally peaked profile near the high-field-side in both DIII-D and COMPASS, covering about 100o poloidal angle. Higher perturbation field level and/or higher particle energy also result in REs being lost to the low-field-side of the limiting surface of these two devices, increasing the effective wetted area. Finally, for the modeled ITER plasmas, the applied RMP field, with optimal poloidal spectrum that maximizes the edge localized mode control, leads to REs being lost to the lower divertor region of the limiting surface within a narrow poloidal band.

3-D field↗

Investigation of low-energy particle remnants in high-energy collisions at the LHC with a skipper-CCD detector

We deployed the Mobile Skipper Testing Apparatus ∼33 m away from the Compact Muon Solenoid collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider. In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb −1 and 1.54 nb −1 for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: ≤ 20⁢𝑒 − and > 20⁢𝑒 − . For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% confidence level constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

Cervantes-Vergara, Brenda A. [Fermi National Accel↗

Double deeply virtual Compton scattering with positron beams at SoLID

Double Deeply Virtual Compton Scattering (DDVCS) is the only experimental channel for the determination of the dependence of the Generalized Parton Distributions (GPDs) on both the average and the transferred momentum independently. The physics observables of the electron induced di-muon production reaction $\vv{e}^{\pm}p \to e^{\pm}p\mu^+\mu^-$ off unpolarized hydrogen are discussed. Their measurement with the high luminosity and large acceptance SoLID spectrometer at the Thomas Jefferson National Accelerator Facility, using polarized and unpolarized positron and electron beams at 11 GeV is investigated. This experimental configuration is shown to provide unprecedented access to the GPDs with the determination of the real and imaginary parts of the Compton Form Factor H in an unexplored phase space, and to enable an exploratory investigation of higher twist effects.

Zhao, S.↗

β -Ga 2 O 3 trench Schottky diodes by low-damage Ga-atomic beam etching

β-Ga 2 O 3 trench Schottky barrier diodes fabricated through a Gallium atomic beam etching technique with excellent field strength and power device figure of merit are demonstrated. Trench formation was accomplished by a low-damage Ga flux etch that enables near-ideal forward operating characteristics that are independent of fin orientation. The reverse breakdown field strength of greater than 5.10 MV/cm is demonstrated at a breakdown voltage of 1.45 kV. This result demonstrates the potential for Ga atomic beam etching and high-quality dielectric layers for improved performance in β-Ga 2 O 3 vertical power devices.

42 ENGINEERING↗