Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

In-situ heating-and-electron tomography for materials research: from 3D ( In-situ 2D) to 4D ( In-situ 3D)

In-situ observation has expanded the application of transmission electron microscopy (TEM) and has made a significant contribution to materials research and development for energy, biomedical, quantum, etc. Recent technological developments related to in-situ TEM have empowered the incorporation of three-dimensional observation, which was previously considered incompatible. In this review article, we take up heating as the most commonly used external stimulus for in-situ TEM observation and overview recent in-situ TEM studies. Then, we focus on the electron tomography (ET) and in-situ heating combined observation by introducing the authors’ recent research as an example. Assuming that in-situ heating observation is expanded from two dimensions to three dimensions using a conventional TEM apparatus and a commercially available in-situ heating specimen holder, the following in-situ heating-and-ET observation procedure is proposed: (i) use a rapid heating-and-cooling function of a micro-electro-mechanical system holder; (ii) heat and cool the specimen intermittently and (iii) acquire a tilt-series dataset when the specimen heating is stopped. This procedure is not too technically challenging and can have a wide range of applications. Essential technical points for a successful 4D (space and time) observation will be discussed through reviewing the authors’ example application.

36 MATERIALS SCIENCE↗

Protein Adhesion on Semi-Fluorinated Polystyrene Surfaces in Static and Dynamic Measurements

Reducing protein adhesion is a critical strategy in fouling-resistant material innovation, with broad applications spanning biomedical and healthcare devices, biosensors, industrial and environmental systems, and other important technological domains. Here, in this study, we elucidated protein adhesion behavior on polystyrene-based thin films by neutron reflectometry (NR) and quartz crystal microbalance with dissipation (QCM-D), using both lysozyme and bovine serum albumin (BSA) as model proteins. To this end, semifluorinated polystyrene thin films with gradient wettability and surface energy were fabricated through dry processing using plasma oxidation and gas-phase deposition. Although it is believed that a fully fluorinated alkyl chain offers extremely low surface energy, thus rejecting foulants, and has been used in many fouling-resistant surface designs, enhanced protein–surface interactions were observed consistently in NR and QCM-D results, due to the combined effects of surface morphology and chemistry. On the contrary, depositing shorter fluorinated silane onto a hydrophilic PS surface contributed to a more homogeneous nanoscale fluorine coating, resulting in less initial protein adsorption and improved surface recovery. Comparative analysis of proteins with different sizes on the nanopatterned semifluorinated surface revealed the influence of molecular characteristics on surface interactions. Lysozyme, being smaller and more compact, showed faster adsorption kinetics and higher surface coverage but largely reversible binding, whereas BSA, with its larger and more flexible structure, formed broader and more stable interfacial layers. This study fills the gap in understanding protein adhesion within the range of hydrophobicity (water contact angle ∼90°), as current strategies often associate with extreme hydrophilic and superhydrophobic surfaces due to hydration or low-surface-energy rejection mechanisms, respectively. It also provides in-depth insights into current combinatorial fouling-resistant surface design.

Yuan, Yue [Oak Ridge National Laboratory (ORNL), O↗

Self-mixing in microtubule-kinesin active fluid from nonuniform to uniform distribution of activity

Active fluids have applications in micromixing, but little is known about the mixing kinematics of systems with spatiotemporally-varying activity. To investigate, UV-activated caged ATP is used to activate controlled regions of microtubule-kinesin active fluid and the mixing process is observed with fluorescent tracers and molecular dyes. At low Péclet numbers (diffusive transport), the active-inactive interface progresses toward the inactive area in a diffusion-like manner that is described by a simple model combining diffusion with Michaelis-Menten kinetics. At high Péclet numbers (convective transport), the active-inactive interface progresses in a superdiffusion-like manner that is qualitatively captured by an active-fluid hydrodynamic model coupled to ATP transport. Results show that active fluid mixing involves complex coupling between distribution of active stress and active transport of ATP and reduces mixing time for suspended components with decreased impact of initial component distribution. This work will inform application of active fluids to promote micromixing in microfluidic devices.

59 BASIC BIOLOGICAL SCIENCES↗

Phage display and other peptide display technologies

ABSTRACT Phage display technology, which is based on the presentation of peptide sequences on the surface of bacteriophage virions, was developed over 30 years ago. Improvements in phage display systems have allowed us to employ this method in numerous fields of biotechnology, as diverse as immunological and biomedical applications, the formation of novel materials and many others. The importance of phage display platforms was recognized by awarding the Nobel Prize in 2018 ‘for the phage display of peptides and antibodies’. In contrast to many review articles concerning specific applications of phage display systems published in recent years, we present an overview of this technology, including a comparison of various display systems, their advantages and disadvantages, and examples of applications in various fields of science, medicine and the broad sense of biotechnology. Other peptide display technologies, which employ bacterial, yeast and mammalian cells, as well as eukaryotic viruses and cell-free systems, are also discussed. These powerful methods are still being developed and improved; thus, novel sophisticated tools based on phage display and other peptide display systems are constantly emerging, and new opportunities to solve various scientific, medical and technological problems can be expected to become available in the near future.

Jaroszewicz, Weronika (ORCID:0000000302948682)↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applications of Kinetic Methods in Thermal Analysis: A Review

Determining kinetic parameters such as activation energy (Ea), pre-exponential factor (A), rate constants, and reaction order (n) via thermal analysis techniques is important to material synthesis and fabrication, industrial production, biomedicals, energy storage, catalysis, etc. Various kinetic methods based on the non-isothermal techniques have been developed to obtain the kinetic parameters. In this review, we focus on introducing various kinetic methods in non-isothermal analysis and their applications in different reactions, including thermal decomposition, solid-state phase transformation, crystallization, thermal ignition, curing process, etc.

Zhang, Xin↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

NASA Tech Briefs, March 2002

Topics include: a special section on data acquisition, software, electronic components and systems, materials, computer programs, mechanics, machinery/automation, manufacturing, biomedical, physical sciences, book and reports, and a special section of Photonics Tech Briefs.

Source record↗

Toward Standardized Microscale Tensile Testing for Two‐Photon Polymerization‐Fabricated Materials in Liquid

Two-photon polymerization (TPP) enables the fabrication of intricate 3D microstructures with submicron precision, offering significant potential in biomedical applications like tissue engineering. In such applications, to print materials and structures with defined mechanics, it is crucial to understand how TPP printing parameters impact the material properties in a physiologically relevant liquid environment. Herein, an experimental approach utilizing microscale tensile testing (μTT) for the systematic measurement of TPP-fabricated microfibers submerged in liquid as a function of printing parameters is introduced. Using a diurethane dimethacrylate-based resin, the influence of printing parameters on microfiber geometry is first explored, demonstrating cross-sectional areas ranging from 1 to 36 μm 2 . Tensile testing reveals Young's moduli between 0.5 and 1.5 GPa and yield strengths from 10 to 60 MPa. The experimental data show an excellent fit with the Ogden hyperelastic polymer model, which enables a detailed analysis of how variations in writing speed, laser power, and printing path influence the mechanical properties of TPP microfibers. The μTT method is also showcased for evaluating multiple commercial resins and for performing cyclic loading experiments. Collectively, this study builds a foundation toward a standardized microscale tensile testing framework to characterize the mechanical properties of TPP printed structures.

mechanical characterization↗

Nanodiamonds in Advancing Biomedical Sciences

Nanodiamonds (NDs), tetrahedral carbon frameworks with size ranging from 1 to 100 nanometers, have gained growing attention in recent years due to their distinct optical, thermal, and mechanical properties compared to other carbon nanomaterials (e.g., graphene, carbon nanotubes, carbon dots). Combined with a high surface-to-volume ratio and tunable and chemically versatile surfaces, these support broad applications across catalysis, electronics, and life sciences. Moreover, the biocompatible characteristics of NDs enable their controllable interfacial interactions with biological systems, positioning them as excellent candidates for advancing cutting-edge biomedical sciences, particularly through the engineering of efficient material-biointerfaces that facilitate optimal interactions with biological systems. Among various forms of NDs, fluorescent nanodiamonds (FNDs) have emerged as some of the most impactful and rapidly advancing materials, demonstrating strong potential in ultrasensitive spin-enhanced bioimaging, high-precision biosensing, traceable drug delivery, and quantum-enabled biomedical technologies. This Perspective introduces the key principles underlying NDs and FNDs, including their structural properties, synthesis methods, and surface functionalization strategies. It also highlights emerging biomedical applications of NDs and FNDs, with particular emphasis on neurological disorders. Last, the article discusses current challenges in advancing NDs as a multifunctional platform for neural therapies with translational potential toward clinical trials.

36 MATERIALS SCIENCE↗

Fe-carbide/Fe-oxide-based nanocomposites synthesized as magnetic nanomaterials via laser ablation synthesis in solution (LASiS)

Magnetic nanostructured materials (MNMs) have gained prominence in materials technology developments owing to their potential biomedical applications for hyperthermia cancer treatment, and transplant organ cryopreservation. Herein, we report the facile and cost-effective synthesis of Fe-based composite MNMs, comprising both Fe@Fe 2 O 3 and Fe 3 C@C core-shell nanoparticles (NPs), via Laser Ablation Synthesis in Solution (LASiS) using Fe targets ablated under acetone and toluene. Detailed materials characterizations using electron microscopy-based imaging, diffraction studies, and spectroscopic analyses - including Raman and Mössbauer spectroscopy - relate the structure-composition properties for different Fe-oxide/carbide phases in the aforesaid MNMs to their respective magnetic responses. Specifically, we confirm the presence of ultra-small (2–10 nm) amorphous Fe-oxide NPs, as well as Fe@Fe 2 O 3 core-shell NPs (20–40 nm) in the samples synthesized by ablating Fe under acetone. In contrast, samples synthesized under toluene indicate a higher concentration of Fe 3 C@C core-shell NPs (20–40 nm) with a relatively low concentration of Fe 2 O 3 NPs (2–10 nm). Furthermore, the crystallinity of the metallic phases and carbonaceous shell coatings are systematically increased by carrying out LASiS under heated toluene (up to ~95 °C). Importantly, mössbauer spectroscopy results indicate that the elevation in toluene temperature leads to an increase in the concentrations of Fe 3 C@C NPs from ~40 % to ~53 % (at.).

36 MATERIALS SCIENCE↗

Towards controlled synthesis of 2D crystals by chemical vapor deposition (CVD)

We report the emergence of two-dimensional (2D) materials has captured the imagination of researchers since graphene was first exfoliated from graphite in 2004. Their exotic properties give rise to many exciting potential applications in advanced electronic, optoelectronic, energy and biomedical technologies. Scalable growth of high quality 2D materials is crucial for their adoption in technological applications the same way the arrival of high quality silicon single crystals was to the semiconductor industry. A huge amount of effort has been devoted to grow large-area, highly crystalline 2D crystals such as graphene and transition metal dichalcogenides (TMDs) through various methods. While CVD growth of wafer-scale monolayer graphene and TMDs has been demonstrated, considerable challenges still remain. In this perspective, we advocate for the focus on the crystal growth morphology as an underpinning for understanding, diagnosing and controlling the CVD process and environment for 2D material growth. Like snowflakes in nature, 2D crystals exhibit a rich variety of morphologies under different growth conditions. The mapping of crystal shapes in the growth parameter space “encodes” a wealth of information, the deciphering of which will lead to better understanding of the fundamental growth mechanism and materials properties. To this end, we envision a collective effort by the 2D materials community to establish the correlation between crystal shapes and the intrinsic thermodynamic and kinetic parameters for CVD reactions through integrated crystal growth experiment, database development and machine learning assisted predictive modeling, which will pave a robust path towards controlled synthesis of 2D materials and heterostructures.

36 MATERIALS SCIENCE↗

2022 American Conference on Neutron Scattering (ACNS 2022)

The 11th American Conference on Neutron Scattering (ACNS 2022) will be held on June 5-9, 2022, in Boulder, CO. The Conference will provide essential information on the breadth and depth of current neutron-related research worldwide. Hosted by the Neutron Scattering Society of America, this year’s Conference will feature a combination of invited and contributed talks, poster sessions, and tutorials. Topics of the conference are: Advances in Neutron Facilities, Instrumentation and Software: Developments in sources, instrumentation, sample environments and control software. Hard Condensed Matter: Magnetism, correlated metals, quantum/topological materials, superconductors, ferroelectrics, multiferroics, glasses, and disorder phenomena. Submissions outlining examples of neutron scattering in industrial and engineering applications involving hard condensed matter systems are also encouraged. Soft Matter: Neutron studies of soft materials and related fields including in situ and in operando studies. Polymers, surfactants, emulsions, gels, nanoparticles, colloidal suspensions and more. Submissions of computational studies or applications of machine learning beneficial to neutron scattering experiments, as well as examples of neutron scattering in industrial and engineering applications are strongly encouraged. Biology, Biophysics and Biotechnology: Neutron studies of biological and biologically relevant systems. Proteins, bio membranes, biological assemblies, natural materials, nucleic acids, drug-delivery platforms and biomedical systems. Submissions of computational studies or applications of machine learning beneficial to biological neutron scattering experiments, as well as examples of neutron scattering in applied research involving biological systems, are strongly encouraged. Materials Chemistry and Energy: Neutron-based studies of functional materials and materials for energy applications. Examples include porous materials such as metal organic frameworks (MOFs), zeolites; phosphors; novel pigments; electrolytes; catalysts; ionic conductors/cathode materials; photovoltaic materials (hybrid perovskites); thermoelectrics; magnetocalorics/electrocalorics. Structural Materials and Engineering: Neutron scattering studies of materials and engineering processes including structural materials, concrete and metals, as well as engineering processes including combustion, corrosion, additive manufacturing, and others. Neutron Physics: Fundamental physical studies of the neutron and related areas. Emerging Applications in Neutron Scattering: Machine Learning and Data Science: Advances in computing power have contributed to rapidly evolving machine learning and data science fields that can be leveraged to the benefit of the neutron scattering community. The purpose of this session is to highlight recent advances in machine learning and data science and to serve as the foundation of a parallel data and computation track highlighting computation advances and applications in neutron scattering throughout the conference.

36 MATERIALS SCIENCE↗

In Situ EXAFS-Based Nanothermometry of Heterodimer Nanocrystals under Induction Heating

The ability to heat nanocrystalline materials through magnetic induction has been used in the fields of catalysis, biomedical sciences, and polymer degradation. However, the working temperature to which the inductively coupled material rises is still poorly understood. Herein, we use extended X-ray absorption fine structure spectroscopy in conjunction with thermal imaging to improve the understanding of heating in inductively coupled systems. After extraction of the Debye–Waller factor from the spectroscopy, we obtain the temperature of inductively heated nanocrystals from the correlated Debye model. We combine carbon-supported iron oxide nanocrystals as induction heating agents with platinum nanocrystals as thermal probes. By testing these nanocrystal species as both unattached nanocrystals and heterodimers, we report that nanostructured systems show a significant temperature difference of up to 73.60 °C when compared to their local support environment. Furthermore, this result has implications for inductively heated catalysis, magnetic hyperthermia for targeted cell death, and polymer synthesis.

09 BIOMASS FUELS↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

Fabrication and testing of high-performance all-metal neutron guides and axisymmetric mirrors by electrochemical replication

Neutron scattering is one of the most useful methods of studying the structure of matter, with applications to biomedical, structural, magnetic and energy-related materials. Neutron-scattering instruments are installed around research reactors or accelerator-based neutron sources, and neutron guides are critical components of these facilities. They are neutron-transport optical devices consisting of state-of-the-art mirrors often tens of meters long. Here we demonstrate a novel fabrication method of all-metallic neutron guides and axisymmetric mirrors by electroplating from precision mandrels. The process allows for the fabrication of single-piece all-metal guides of prismatic and axisymmetric shapes. We also demonstrate supermirror guides and axisymmetric focusing supermirrors produced with the same technology. We present the fabrication and tests of the multilayer-coated replicated guides and optic and show that the mandrel is reproduced with high fidelity and reliability. Furthermore, such supermirror optics will provide game-changing improvements in neutron techniques.

36 MATERIALS SCIENCE↗

Image-Processing Program

IMAGEP manipulates digital image data to effect various processing, analysis, and enhancement functions. It is keyboard-driven program organized into nine subroutines. Within subroutines are sub-subroutines also selected via keyboard. Algorithm has possible scientific, industrial, and biomedical applications in study of flows in materials, analysis of steels and ores, and pathology, respectively.

Roth, D. J.↗

Toxic substances registry system. Index of material safety data sheets

The January 1995 revision of the index of material safety data sheets is presented. The index of toxic substances is divided by maufacturer, tradename, stock number, and distributor. This index provides a means of accessing information including hazards, uses, and chemical composition of materials stored and used at KSC's Biomedical Operations and Research Office.

Source record↗