Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

MOBY, A Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols

The Marine Optical Buoy (MOBY) is the centerpiece of the primary ocean measurement site for calibration of satellite ocean color sensors based on independent in situ measurements. Since late 1996, the time series of normalized water-leaving radiances L(sub WN)(lambda) determined from the array of radiometric sensors attached to MOBY are the primary basis for the on-orbit calibrations of the USA Sea-viewing Wide Field-of-view Sensor (SeaWiFS), the Japanese Ocean Color and Temperature Sensor (OCTS), the French Polarization Detection Environmental Radiometer (POLDER), the German Modular Optoelectronic Scanner on the Indian Research Satellite (IRS1-MOS), and the USA Moderate Resolution Imaging Spectrometer (MODIS). The MOBY vicarious calibration L(sub WN)(lambda) reference is an essential element in the international effort to develop a global, multi-year time series of consistently calibrated ocean color products using data from a wide variety of independent satellite sensors. A longstanding goal of the SeaWiFS and MODIS (Ocean) Science Teams is to determine satellite-derived L(sub WN)(labda) with a relative combined standard uncertainty of 5 %. Other satellite ocean color projects and the Sensor Intercomparison for Marine Biology and Interdisciplinary Oceanic Studies (SIMBIOS) project have also adopted this goal, at least implicitly. Because water-leaving radiance contributes at most 10 % of the total radiance measured by a satellite sensor above the atmosphere, a 5 % uncertainty in L(sub WN)(lambda) implies a 0.5 % uncertainty in the above-atmosphere radiance measurements. This level of uncertainty can only be approached using vicarious-calibration approaches as described below. In practice, this means that the satellite radiance responsivity is adjusted to achieve the best agreement, in a least-squares sense, for the L(sub WN)(lambda) results determined using the satellite and the independent optical sensors (e.g. MOBY). The end result of this approach is to implicitly absorb unquantified, but systematic, errors in the atmospheric correction, incident solar flux, and satellite sensor calibration into a single correction factor to produce consistency with the in situ data.

Clark, Dennis K.↗

Analysis of SRM model nozzle calibration test data in support of IA12B, IA12C and IA36 space shuttle launch vehicle aerodynamics tests

Variations of nozzle performance characteristics of the model nozzles used in the Space Shuttle IA12B, IA12C, IA36 power-on launch vehicle test series are shown by comparison between experimental and analytical data. The experimental data are nozzle wall pressure distributions and schlieren photographs of the exhaust plume shapes. The exhaust plume shapes were simulated experimentally with cold flow while the analytical data were generated using a method-of-characteristics solution. Exhaust plume boundaries, boundary shockwave locations and nozzle wall pressure measurements calculated analytically agree favorably with the experimental data from the IA12C and IA36 test series. For the IA12B test series condensation was suspected in the exhaust plumes at the higher pressure ratios required to simulate the prototype plume shapes. Nozzle calibration tests for the series were conducted at pressure ratios where condensation either did not occur or if present did not produce a noticeable effect on the plume shapes. However, at the pressure ratios required in the power-on launch vehicle tests condensation probably occurs and could significantly affect the exhaust plume shapes.

Baker, L. R., Jr.↗

Software For Calibration Of Polarimetric SAR Data

POLCAL (Polarimetric Radar Calibration) software tool intended to assist in calibration of synthetic-aperture radar (SAR) systems. In particular, calibrates Stokes-matrix-format data produced as standard product by NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). Version 4.0 of POLCAL is upgrade of version 2.0. New options include automatic absolute calibration of 89/90 data, distributed-target analysis, calibration of nearby scenes with corner reflectors, altitude or roll-angle corrections, and calibration of errors introduced by known topography. Reduces crosstalk and corrects phase calibration without use of ground calibration equipment. Written in FORTRAN 77.

Van Zyl, Jakob↗

Development of a Non-Iterative Balance Load Prediction Algorithm for the NASA Ames Unitary Plan Wind Tunnel

A non-iterative load prediction algorithm for strain-gage balances was developed for the NASA Ames Unitary Plan Wind Tunnels that computes balance loads from the electrical outputs of the balance bridges and a set of state variables. A state variable could be, for example, a balance temperature difference or the bellows pressure of a flow-through balance. The algorithm directly uses regression models of the balance loads for the load prediction that were obtained by applying global regression analysis to balance calibration data. This choice greatly simplifies both implementation and use of the load prediction process for complex balance configurations as no load iteration needs to be performed. The regression model of a balance load is constructed by using terms from a total of nine term groups. Four term groups are derived from a Taylor Series expansion of the relationship between the load, gage outputs, and state variables. The remaining five term groups are defined by using absolute values of the gage outputs and state variables. Terms from these groups should only be included in the regression model if calibration data from a balance with known bi-directional outputs is analyzed. It is illustrated in detail how global regression analysis may be applied to obtain the coefficients of the chosen regression model of a load component assuming that no linear or massive near-linear dependencies between the regression model terms exist. Data from the machine calibration of a six-component force balance is used to illustrate both application and accuracy of the non-iterative load prediction process.

Ulbrich, Norbert M.↗

Studies of regional and global tectonics and the rotation of the earth using very-long baseline interferometry

Progress in the areas of data analysis, atmospheric delay calibration and software conversion is reported. Over 800 very long baseline interferometry (VLBI) experiments were analyzed in the last 6 months. Reprocessing of the Mark III VLBI data set is almost completed. Results of analysis of the water-vapor radiometer (WVR) data were submitted and a preprint of a related paper is attached. Work on conversion of the VLBI analysis software from HP1000 to Unix based workstations is continuing.

Shapiro, Irwin I.↗

Space radiation studies

Instrument design and data analysis expertise was provided in support of several space radiation monitoring programs. The Verification of Flight Instrumentation (VFI) program at NASA included both the Active Radiation Detector (ARD) and the Nuclear Radiation Monitor (NRM). Design, partial fabrication, calibration and partial data analysis capability to the ARD program was provided, as well as detector head design and fabrication, software development and partial data analysis capability to the NRM program. The ARD flew on Spacelab-1 in 1983, performed flawlessly and was returned to MSFC after flight with unchanged calibration factors. The NRM, flown on Spacelab-2 in 1985, also performed without fault, not only recording the ambient gamma ray background on the Spacelab, but also recording radiation events of astrophysical significance.

Gregory, J. C.↗

WRATS Integrated Data Acquisition System

The Wing and Rotor Aeroelastic Test System (WRATS) data acquisition system (DAS) is a 64-channel data acquisition display and analysis system specifically designed for use with the WRATS 1/5-scale V-22 tiltrotor model of the Bell Osprey. It is the primary data acquisition system for experimental aeroelastic testing of the WRATS model for the purpose of characterizing the aeromechanical and aeroelastic stability of prototype tiltrotor configurations. The WRATS DAS was also used during aeroelastic testing of Bell Helicopter Textron s Quad-Tiltrotor (QTR) design concept, a test which received international attention. The LabVIEW-based design is portable and capable of powering and conditioning over 64 channels of dynamic data at sampling rates up to 1,000 Hz. The system includes a 60-second circular data archive, an integrated model swashplate excitation system, a moving block damping application for calculation of whirl flutter mode subcritical damping, a loads and safety monitor, a pilot-control console display, data analysis capabilities, and instrumentation calibration functions. Three networked computers running custom-designed LabVIEW software acquire data through National Instruments data acquisition hardware. The aeroelastic model (see figure) was tested with the DAS at two facilities at NASA Langley, the Transonic Dynamics Tunnel (TDT) and the Rotorcraft Hover Test Facility (RHTF). Because of the need for seamless transition between testing at these facilities, DAS is portable. The software is capable of harmonic analysis of periodic time history data, Fast Fourier Transform calculations, power spectral density calculations, and on-line calibration of test instrumentation. DAS has a circular buffer archive to ensure critical data is not lost in event of model failure/incident, as well as a sample-and-hold capability for phase-correct time history data.

Piatak, David J.↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10-5 for the non-dimensional total pressure and 2.88 x 10-5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10 -5 for the non-dimensional total pressure and 2.88 x 10 -5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

TESS Data Release Notes:Reprocessing of Sectors 14–19, DR30 & DR33

TESS data release 30 (DR30) provides reprocessed data products of Sector 14 to 19. The updated data products were generated using version 4.0 of the science processing pipeline and conform to the final set of data anomaly flags defined over the last two years of TESS data analysis and pipeline development. Data release 33 (DR33) corresponds to a multisector search for transiting planets in the same reprocessed data. A detailed description of the changes in the data products in DR30 and DR33 is discussed in§2, and a brief list of changes is summarized here: The timestamps for 2 minute cadence and FFI data are more accurate. The differences between reprocessed data and previous data releases are less than 2.0 seconds in all cases. Photometric apertures were increased in size for targets with T mag<11. Three new Data Anomaly Flags were added to mitigate the effects of scattered light:–Cadences with strong scattered light signals or saturation effects that corrupt the calibration data are flagged and removed from analysis (bit 15, value 16384, “Bad Calibration Exclude”).–Scattered light data anomaly flags are customized for each target, and flagged automatically based on the local background level (bit 13, value 4096, ”Scattered light flag”).–Cadences with insufficient targets to derive cotrending basis vectors are flagged and the PDCSAP FLUX light curves are set to NULL at these times (bit 16, value 32768, “Insufficient Targets for Error Correction Exclude”). The planet search of the reprocessed light curves produced a different set of TCEs from the original processed data. Although there is a high degree of overlap between the original and reprocessed data (∼83% of targets produced TCEs in common), new TCEs were produced in DR30 and not every TCE from previous data releases was recovered. The same is true of the multisector search results from DR33 compared to DR28

TESS'↗

Graphical and Numerical Description of Strain-Gage Balance Interactions

A new approach for the graphical and numerical description of balance interactions is presented. The approach uses data from single-component loads as input. This choice has the two advantages. First, the number of applied loads is at the minimum needed for interactions to be observed. In addition, the loads used for the description of interactions can easily be repeated at different sites. Output differences relative to the outputs of the zero load point of a load series are used for the description of interactions. Similarly, load differences relative to the loads of the zero load point of a load series are used for the description of the loads. Interactions are plotted versus the load differences for each load component while omitting the outputs of the primary gage of the chosen load component. The resulting plots have a characteristic star pattern as interactions are zero at zero load. Numerical estimates of the slopes of the interactions can be reverse-engineered from the load prediction equations of a balance if calibration data is examined. The slopes are the off-diagonal coefficients of the inverse of the matrix that has the coefficients of the linear terms of the fitted loads if the Non-Iterative Method is used for the analysis. Similarly, the slopes are the off-diagonal coefficients of the inverse of the matrix that is the non-iterative part of the primary load iteration equation if the Iterative Method is used for the analysis. Data from the calibration of a force balance is processed to illustrate the proposed graphical and numerical description of interactions.

wind tunnel test↗

Improved Regression Analysis of Temperature-Dependent Strain-Gage Balance Calibration Data

An improved approach is discussed that may be used to directly include first and second order temperature effects in the load prediction algorithm of a wind tunnel strain-gage balance. The improved approach was designed for the Iterative Method that fits strain-gage outputs as a function of calibration loads and uses a load iteration scheme during the wind tunnel test to predict loads from measured gage outputs. The improved approach assumes that the strain-gage balance is at a constant uniform temperature when it is calibrated and used. First, the method introduces a new independent variable for the regression analysis of the balance calibration data. The new variable is designed as the difference between the uniform temperature of the balance and a global reference temperature. This reference temperature should be the primary calibration temperature of the balance so that, if needed, a tare load iteration can be performed. Then, two temperature{dependent terms are included in the regression models of the gage outputs. They are the temperature difference itself and the square of the temperature difference. Simulated temperature{dependent data obtained from Triumph Aerospace's 2013 calibration of NASA's ARC-30K five component semi{span balance is used to illustrate the application of the improved approach.

wind tunnel testing↗

Study on spectral/radiometric characteristics of the Thematic Mapper for land use applications

Previous characterization of scan-related low-frequency noise was extended and refined through detailed analysis of shutter calibration data on CCT-ADDS tapes and reflective-band data from nighttime acquisitions. A recommended correction procedure was identified that uses calibration shutter data both as a diagnostic and to obtain correction values. Through comparison of coincident TM and MSS data, illustrations of the added information content of TM data for agricultural applications were developed. The capability of improved spatial resolution to better define boundaries and to resolve spatial details is shown. Spectral analysis of tasseled-cap transformations of TM and MSS data shows high correlation between greenness features, greater signal range for TM, and indications that a subset of TM bands could accurately simulate MSS data, if required.

Malila, W. A.↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibration and Change Detection of [Alaska Satellite Facility] ASF/ERS-1 SAR Image Data

The results of a calibration analysis performed on ERS-1 synthetic aperture radar (SAR) images produced by the Alaska SAR facility (ASF) are presented, together with some preliminary results on change detection on the Alaskan north slope derived from the same images. Image quality, geometric and radiometric fidelity, and repeat pass radiometric stability have all been determined to be satisfactory. A calibration workstation has been designed and implemented for use in operational data quality analysis of ASF data products. Higher-level data analysis programs have been developed for interferometry, texture analysis, and change detection.

Fatland, Rob↗

US Navy Submarine Sea Trial of NASA developed Multi-Gas Monitor

During a successful 2 year technology demonstration of the tunable diode laser spectroscopy (TDLS) based Multi-Gas Monitor (MGM) on the International Space Station (ISS), we began discussing with the US Navy the possibility of conducting a sea trial of an MGM on a submarine. The sea trial would also include a gas chromatography/differential mobility spectrometer based Air Quality Monitor (AQM), which is used operationally on ISS for volatile organic compound analysis. AQM preparation and results will be the subject of a separate paper. The Navy's interest in testing NASA equipment in general relates to their ongoing search for better air monitoring technology. NASA's goal is studying submarines as closed environment analogs to spacecraft. MGM's core technology was developed by Vista Photonics Inc. using Small Business Innovation Research (SBIR) grants and expanded for various applications using NASA program funding. The MGM measures oxygen, carbon dioxide, ammonia and water vapor in ambient air, displays concentrations with temperature and pressure, and stores 30 second moving averages. The sea trial involves collocating the instrument with the Central Atmosphere Monitoring System (CAMS Mk II) of the submarine, connecting it to rack power prior to departure, and letting it run during the entire 90 day patrol. All data is stored within MGM, with no connection to the vessel data bus. Crew intervention is limited to checking MGM periodically to see that it is working and power cycling if necessary. After the trial is over, the unit with its data will be retrieved. Post sea trial calibration check and data analysis are planned and results will be compared with both CAMS Mk II data and results from MGM's ISS technology demonstration. Since the sea trial itself has been delayed, this paper describes the preparation of MGM for the sea trial and also provides a summary of the latest data from the ISS MGM technology demonstration.

Mudgett, Paul D.↗

Optimizing ICEBERG LArTPC Run Configuration for Data Collection

To ensure accurate data collection and diagnostics of the ICEBERG electronics, charge injection runs were completed using a pulser to mimic known charge deposition amounts on the LArTPC wires and collect data for analysis and calibration. This analysis is essential for optimizing the detector's performance by identifying the optimal range of DAC values that avoid saturation zones and provide the best experimental results for non-pulser runs.

Ganguly, Neil↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗