Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Constraining the masses of high-redshift clusters with weak lensing: Revised shape calibration testing for the impact of stronger shears and increased blending

Weak lensing measurements suffer from well-known shear estimation biases, which can be partially corrected for with the use of image simulations. Here we present an analysis of simulated images that mimic Hubble Space Telescope/Advance Camera for Surveys observations of high-redshift galaxy clusters, including cluster specific issues such as non-weak shear and increased blending. Our synthetic galaxies have been generated to have similar observed properties as the background-selected source samples studied in the real images. First, we used simulations with galaxies placed on a grid to determine a revised signal-to-noise-dependent (S/N KSB ) correction for multiplicative shear measurement bias, and to quantify the sensitivity of our KSB+ bias calibration to mismatches of galaxy or PSF properties between the real data and the simulations. Next, we studied the impact of increased blending and light contamination from cluster and foreground galaxies, finding it to be negligible for high-redshift (z > 0.7) clusters, whereas shear measurements can be affected at the ~1% level for lower redshift clusters given their brighter member galaxies. Finally, we studied the impact of fainter neighbours and selection bias using a set of simulated images that mimic the positions and magnitudes of galaxies in Cosmic Assembly Near-IR Deep Extragalactic Legacy Survey (CANDELS) data, thereby including realistic clustering. While the initial SExtractor object detection causes a multiplicative shear selection bias of –0.028 ± 0.002, this is reduced to –0.016 ± 0.002 by further cuts applied in our pipeline. Given the limited depth of the CANDELS data, we compared our CANDELS-based estimate for the impact of faint neighbours on the multiplicative shear measurement bias to a grid-based analysis, to which we added clustered galaxies to even fainter magnitudes based on Hubble Ultra Deep Field data, yielding a refined estimate of ~ –0.013. Our sensitivity analysis suggests that our pipeline is calibrated to an accuracy of ~0.015 once all corrections are applied, which is fully sufficient for current and near-future weak lensing studies of high-redshift clusters. As an application, we used it for a refined analysis of three highly relaxed clusters from the South Pole Telescope Sunyaev-Zeldovich survey, where we now included measurements down to the cluster core (r > 200 kpc) as enabled by our work. Compared to previously employed scales (r > 500 kpc), this tightens the cluster mass constraints by a factor 1.38 on average.

79 ASTRONOMY AND ASTROPHYSICS↗

The WRF-Solar Ensemble Prediction System to Provide Solar Irradiance Probabilistic Forecasts

In this study, we introduce the recently developed WRF-Solar Ensemble System (WRF-Solar EPS) and a calibration method. The performances of forecast models are evaluated using the National Solar Radiation Data Base (NSRDB) observational analysis for day-ahead solar irradiance predictions. The results demonstrate that the ensemble forecast improves the quality of the forecasts by taking into account the uncertainty of each ensemble member. The Analog Ensemble (AnEn) calibration contributed to the reduction of positive bias and an overall improvement in the probabilistic attributes such as reliability and statistical consistency.

analog ensemble↗

Variational inference of effective range parameters for 3 He− 4 He scattering

We use two different methods, Monte Carlo sampling and variational inference (VI), to perform a Bayesian calibration of the effective-range parameters in 3 He– 4 He elastic scattering. The parameters are calibrated to data from a recent set of 3 He– 4 He elastic scattering differential cross section measurements. Analysis of these data for E lab ≤ 4.3 MeV yields a unimodal posterior for which both methods obtain the same structure. However, the effective-range expansion amplitude does not account for the 7/2 − state of 7 Be so, even after calibration, the description of data at the upper end of this energy range is poor. The data up to E lab = 2.6 MeV can be well described, but calibration to this lower-energy subset of the data yields a bimodal posterior. After adapting VI to treat such a multi-modal posterior we find good agreement between the VI results and those obtained with parallel-tempered Monte Carlo sampling.

effective field theory↗

A measurement of the Higgs boson mass in the diphoton decay channel

A measurement of the mass of the Higgs boson in the diphoton decay channel is presented. This analysis is based on 35.9 fb$^{-1}$ of proton-proton collision data collected during the 2016 LHC running period, with the CMS detector at a center-of-mass energy of 13 TeV. A refined detector calibration and new analysis techniques have been used to improve the precision of this measurement. The Higgs boson mass is measured to be $m_\mathrm{H} =$ 125.78$\pm$0.26 GeV. This is combined with a measurement of $m_\mathrm{H}$ already performed in the H$\to$ZZ$\to$4$\ell$ decay channel using the same data set, giving $m_\mathrm{H} =$ 125.46$\pm$0.16 GeV. This result, when further combined with an earlier measurement of $m_\mathrm{H}$ using data collected in 2011 and 2012 with the CMS detector, gives a value for the Higgs boson mass of $m_\mathrm{H} =$ 125.38$\pm$0.14 GeV. This is currently the most precise measurement of the mass of the Higgs boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-dimensional plasma density evolution local to the inversion layer during sawtooth crash events using Beam Emission Spectroscopy

Here, we present methods for analyzing Beam Emission Spectroscopy (BES) data to obtain the plasma density evolution associated with rapid sawtooth crash events at the DIII-D tokamak. BES allows coverage over a 2D spatial plane, inherently local measurements, with fast time responses, and, therefore, provides a valuable new channel for data during sawtooth events. A method is developed to remove sawtooth-induced edge-light pulses contained in the BES data. The edge light pulses appear to be from the D α emission produced by edge recycling during sawtooth events, and are large enough that traditional spectroscopic filtering and data analysis techniques are insufficient to deduce physically meaningful quantities. A cross-calibration of 64 BES channels is performed by using a novel method to ensure accurate measurements. For the large-amplitude density oscillations observed, we discuss and use the non-linear relationship between the BES signal δI/ I 0 and the plasma density variation δn e / n e0 . The 2D BES images cover an 8 × 20 cm 2 region around the sawtooth inversion layer and show large-amplitude density oscillations, with additional significant spatial variations across the inversion layer that grows and peaks near the time of the temperature crash. The edge light removal technique and method of converting large-amplitude δI/ I 0 to δn e / n e0 presented here may help analyze other impulsive MHD phenomena in tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinetic model development and Bayesian uncertainty quantification for the complete reduction of Fe-based oxygen carriers with CH 4 , CO, and H 2 for chemical looping combustion

In this work, three kinetic models are developed and calibrated for the complete multi-step reduction of an Fe-based oxygen carrier (OC) particle with CH 4 , CO, and H 2 , using data from thermogravimetric analysis. The complete reduction rate profiles exhibit complex dynamics whose trajectory is significantly different depending on the reducing gas. A Bayesian model building and parameter estimation framework is applied for simultaneous parameter and model structure uncertainty quantification. The final models show excellent agreement between model predictions and calibration data, as well as new data not used for calibration (for the reduction of the OC with CH 4 ). Parameter uncertainty is quantified by determining joint posterior distribution, and model structure uncertainty is addressed by incorporating Gaussian process stochastic functions (represented by Bayesian smoothing splines) into the kinetic models. The final kinetic models with discrepancy functions are readily employable in equation-oriented simulation and optimization platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

When physics-informed data analytics outperforms black-box machine learning: A case study in thickness control for additive manufacturing

Aerosol jet printing (AJP) has emerged as a promising noncontact additive manufacturing method for high-resolution printing for a wide range of material systems. A key challenge limiting the broader adoption of AJP in the material science community is the lack of methods to precisely control thickness. Herein, we develop a model-based design of experiment (MBDoE) framework that integrates physics-informed models, nonlinear regression, and information criteria to postulate, select and calibrate the best model to describe and optimize the AJP manufacturing process. Starting with already available data from system commissioning (e.g., prior single variable sensitivity analysis), four candidate physics-informed models are postulated and trained. MBDoE identifies a single additional optimal experiment to validate these predictive models with quantified uncertainties, which are then used to determine the best experimental conditions to control printed film thickness. As a comparative benchmark, the analysis is repeated using the same dataset with nonparametric Gaussian process regression (GPR) model that does not incorporate physical information. Using MBDoE principles, we find that only five experiments are necessary to calibrate the nonlinear physics-informed parametric model, and with said limited data, this model outperforms the black-box machine learning GPR model. This key result underscores an emerging trend in the data science community: incorporating physical information into predictive models often drastically reduces the data requirements. Leveraging MBDoE further increased the data efficiency. By design, the proposed data science framework is general in nature and can be easily extended to other experimental and additive manufacturing systems beyond AJP.

Aerosol jet printing↗

Isotopic Analysis using FRAM [Slides]

FRAM is an isotopic analysis code nominally designed for plutonium and uranium. It stands for Fixed-energy Response-function Analysis with Multiple efficiencies. It has self-calibration using several gamma-ray peaks and can analyze gamma ray data from 30keV to >1MeV of HPGe, CdTe, or LaBr3 detector. The key difference between the MGA family of codes (from LLNL) and FRAM is the use of user-editable analysis parameters in the latter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Unified Photometric Redshift Calibration for Weak Lensing Surveys Using the Dark Energy Spectroscopic Instrument

The effective redshift distribution n(z) of galaxies is a critical component in the study of weak gravitational lensing. Here, we introduce a new method for determining n(z) for weak lensing surveys based on high-quality redshifts and neural-network-based importance weights. Additionally, we present the first unified photometric redshift calibration of the three leading stage-III weak lensing surveys, the Dark Energy Survey (DES), the Hyper Suprime-Cam (HSC) survey, and the Kilo-Degree Survey (KiDS), with state-of-the-art spectroscopic data from the Dark Energy Spectroscopic Instrument (DESI). We verify our method using a new, data-driven approach and obtain n(z) constraints with statistical uncertainties of the order of $σ_z$ ~ 0.01 and smaller. Our analysis is largely independent of previous photometric redshift calibrations and, thus, provides an important cross-check in light of recent cosmological tensions. Overall, we find excellent agreement with previously published results on the DES Y3 and HSC Y1 data sets, while there are some differences on the mean redshift with respect to the previously published KiDS-1000 results. We attribute the latter to mismatches in photometric noise properties in the COSMOS field compared to the wider KiDS self-organizing map-gold catalog. At the same time, the new n(z) estimates for KiDS do not significantly change estimates of cosmic structure growth from cosmic shear. Finally, we discuss how our method can be applied to future weak lensing calibrations with DESI data.

Lange, J. U. [American Univ., Washington, DC (Unit↗

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator↗

BiRD (BioReactorDesign) [SWR-24-35]

Numerical simulations can accelerate scale up and optimization of bioreactors. This project provides a toolbox to facilitate such numerical simulations in OpenFOAM. The tool box contains 1) mesh generations tools for several typical bio reactor types in OpenFOAM 2) Inverse modeling tools to calibrate models using available experimental data 3) post processing tools that accelerate and streamline the analysis of the numerical simulations.

Hassanaly, Malik↗

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

SELKIE Spectral Extraction Results

This document describes results from the WAMOR Chesapeake Bay collection in October 2024, a data collection from the Arkeus HSOR hyperspectral sensor. The calibration array was staged at USCG Station Little Creek, Virginia. With the provided HSOR imagery and data, our analysis does not show a capability to effectively detect materials of interest from non-materials of interest as well as differentiate materials of interest from each other, the materials of interest being polypropylene, polyester, and cotton. The fundamental reasons are (1) the spectral bands of HSOR do not reside in specific wavelength locations to allow for material identification and (2) the provided imagery appears to not have consistent band-to-band relationships indicative of a lack of calibration (gain/offsets) or some other calibration issues. With regard to analyzing a subset of the delivered HSOR, HSOR can make general statements about materials not being water and have the capability to make color assessments.

36 MATERIALS SCIENCE↗

MultiPEM Toolbox: User Manual [Rev. 2]

This document explains use of the Multi-Phenomenology Explosion Monitoring (Multi PEM) Toolbox, a collection of R scripts for estimating the unknown device parameters of a new event with uncertainty quantification. The methodology and application used for illustration in this user manual are fully documented in a Los Alamos National Laboratory technical report hereafter designated “WPA” for reference. Additional details on the application are found in a recent journal article. Two assessment types are available: rapid and complete. Rapid assessments are conducted in two stages, as described in Section 2. In the first stage, calibration data are used to estimate forward and error model parameters (WPA, §5.1) and (if relevant) errors-in-variables yield values for calibration sources (WPA, §3, Equation (3)). In the second stage, new event data are used to estimate the unknown new event device parameters (WPA, §5.2) with uncertainty quantification. Two options for treating the inferred first stage parameters in second stage Bayesian analysis are available: fixing them at their maximum likelihood estimate (default), or multiple imputation. Multiple imputation involves utilizing several posterior samples (imputations) of the first stage parameters as fixed values in the second stage posterior sampling of the new event device parameters. Second stage sampling is conducted across imputations in parallel to improve computational efficiency. This method produces improved uncertainty quantification of the new event device parameters compared with the default treatment of the first stage parameters, at the expense of additional computation. Complete assessments are conducted in a single stage, as described in Section 3. Calibration and (if relevant) new event data are used simultaneously to estimate all forward model, error model, and (if relevant) new event device parameters with uncertainty quantification on the latter. As the name suggests, rapid assessments generally run substantially faster than complete assessments (even with multiple imputation), because the results of first stage analysis can be stored and incorporated into estimating a relatively low-dimensional space of new event device parameters whenever relevant new event data becomes available. On the other hand, complete assessments must be run on the full set of model and device parameters with calibration and new event data every time the latter becomes available.

97 MATHEMATICS AND COMPUTING↗

Parametrizing the detector response with neural networks

In high energy physics, characterizing the response of a detector to radiation is one of the most important and fundamental experimental tasks. In many cases, this task is accomplished by parameterizing summary statistics of the full detector response probability density. The parameterized detector response can then be used for calibration as well as for directly improving physics analysis sensitivity. This paper reports on how to parameterize summary statistics of the detector response using neural networks. Specifically, neural networks are powerful tools for incorporating multidimensional data and the loss function used during training determines which summary statistic is learned. One common summary statistic that has not been combined with deep learning (as far as the authors are aware) is the mode. A neural network-based approach to mode learning is proposed and empirically demonstrated in the context of high energy jet calibrations. Altogether, the neural network-based toolkit for detector response parameterization can enhance the utility of data collected at high energy physics experiments and beyond.

47 OTHER INSTRUMENTATION↗

Planck intermediate results

We present the NPIPE processing pipeline, which produces calibrated frequency maps in temperature and polarization from data from the Planck Low Frequency Instrument (LFI) and High Frequency Instrument (HFI) using high-performance computers. NPIPE represents a natural evolution of previous Planck analysis efforts, and combines some of the most powerful features of the separate LFI and HFI analysis pipelines. For example, following the LFI 2018 processing procedure, NPIPE uses foreground polarization priors during the calibration stage in order to break scanning-induced degeneracies. Similarly, NPIPE employs the HFI 2018 time-domain processing methodology to correct for bandpass mismatch at all frequencies. In addition, NPIPE introduces several improvements, including, but not limited to: inclusion of the 8% of data collected during repointing manoeuvres; smoothing of the LFI reference load data streams; in-flight estimation of detector polarization parameters; and construction of maximally independent detector-set split maps. For component-separation purposes, important improvements include: maps that retain the CMB Solar dipole, allowing for high-precision relative calibration in higher-level analyses; well-defined single-detector maps, allowing for robust CO extraction; and HFI temperature maps between 217 and 857 GHz that are binned into 0'.9 pixels (Nside = 4096), ensuring that the full angular information in the data is represented in the maps even at the highest Planck resolutions. The net effect of these improvements is lower levels of noise and systematics in both frequency and component maps at essentially all angular scales, as well as notably improved internal consistency between the various frequency channels. Based on the NPIPE maps, we present the first estimate of the Solar dipole determined through component separation across all nine Planck frequencies. The amplitude is (3366.6 ± 2.7) μK, consistent with, albeit slightly higher than, earlier estimates. From the large-scale polarization data, we derive an updated estimate of the optical depth of reionization of τ = 0.051 ± 0.006, which appears robust with respect to data and sky cuts. There are 600 complete signal, noise and systematics simulations of the full-frequency and detector-set maps. As a Planck first, these simulations include full time-domain processing of the beam-convolved CMB anisotropies. The release of NPIPE maps and simulations is accompanied with a complete suite of raw and processed time-ordered data and the software, scripts, auxiliary data, and parameter files needed to improve further on the analysis and to run matching simulations.

79 ASTRONOMY AND ASTROPHYSICS↗