Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A radio optical reference frame. IV - Additional radio source positions in the Northern Hemisphere

Seventy-seven extragalactic radio sources north of -2 deg declination have been observed using Mark III VLBI during 13 experiments from 1988 October to 1989 November. Radio positions derived from these observations supplement an ongoing project to define and maintain an all-sky radio/optical reference frame of 400 or more extragalactic sources with milliarcsecond (mas) accurate radio and optical positions. Positions for 11 new sources are presented along with improved positions for 54 sources already in the reference-frame catalog. An additional five sources have been determined to be unsuitable reference-frame objects. Observations of seven calibration sources tie the new positions to the existing catalog. The radio positions of the new sources have formal mean errors of about 0.7 mas in each coordinate. Sources for which improved positions are reported now have formal errors not greater than 1 mas, an improvement in some cases by as much as 85 percent. The complementary optical program is addressed briefly.

Fey, A. L.↗

In-flight radiometry of an airborne multispectral sensor

The in-flight radiometric behavior of the NS001 Landsat Thematic Mapper simulator is being reexamined. The absolute radiometric calibration and polarization sensitivity are being analyzed based on data collected in 1990 and 1991. The NS001 has continuously variable gain settings controlled by the aircraft operator. As such, the of in-flight calibration source, an integrating sphere in the solar reflective spectrum, is the only means for calibrating this instrument. Upgrades to the power supply and monitoring circuitry in 1990 improved the in-flight stability. Preliminary results in-flight calibrations of the NS001 indicate no improvement in radiometric accuracy. Laboratory tests have also shown that the NS001 shows strong sensitivity to the degree of polarization and state of the incoming radiations. Simulation studies for typical in-flight conditions have shown that for the NS001 scanning in the principal plane of the sun over a vegetated target, radiance errors reached +/-10 percent in the 0.45-0.52-micron channel and varied with scan angle.

Markham, Brian L.↗

Radio optical reference frame. 6: Additional source positions in the northern hemisphere

Radio and optical positions for northern hemisphere extragalactic sources are reported. Milliarcsecond (mas) accurate radio positions of 106 sources north of -2 deg declination are derived from Mark III Very Long Baseline Interferometry (VLBI) observations taken during ten experiments from 1990 January through 1990 October. The results presented supplement an ongoing project to define and maintain an all-sky radio/optical reference frame of 400 or more extragalactic sources with mas accurate radio and optical positions. Radio positions for 34 new sources are presented along with improved radio positions for 72 sources already in the reference frame catalog. An additional nine sources have been determined to be unsuitable reference frame objects. Radio observations of nine calibration sources tie the new positions to the existing catalogue. The radio positions of the new sources have formal mean errors of approximately 0.7 mas in right ascension and approximately 1.0 mas in declination. Sources for which we report improved radio positions now have formal mean errors of approximately 0.5 mas in both coordinates, an improvement in some cases by as much as 75%. Positions in the FK5 system have also been obtained for the optical counterparts of an additional five northern hemisphere radio sources using prime focus plates from the Kitt Peak National Observatory's 4 m telescope and a Ritchey-Chretien focus plate from the Calar Alto 2.2 m telescope. The optical positions have internal accuracies of about 0.03 sec and differ from the radio positions by about 0.07 sec on the average.

Fey, A. L.↗

Laboratory Astrophysics Using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

We completed modifications to the new microcalorimeter system dedicated for use on the EBIT at NIST, which included: 1) a redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) the microcalorimeter electronic circuit was significantly improved to ensure long-term stability for lengthy experimental runs

Brinton, John↗

COBE Final Report: Dirbe Celestial Calibration

We report the results of a comparative study of the COsmic Background Explorer/Diffuse InfraRed Background Experiment (COBE/DIRBE) photometric calibration over about 100 selected stellar and non-stellar calibration objects across a wide range of the DIRBE instrument dynamic range, wavelength coverage, and source temperature. A statistical comparison of the DIRBE-reported flux to the accepted values from the literature (as summarized in the CIO) provides an independent verification of the DIRBE point source calibration.

Burdick, Shawn V.↗

Calibration of X-Ray Observatories

Accurate calibration of x-ray observatories has proved an elusive goal. Inaccuracies and inconsistencies amongst on-ground measurements, differences between on-ground and in-space performance, in-space performance changes, and the absence of cosmic calibration standards whose physics we truly understand have precluded absolute calibration better than several percent and relative spectral calibration better than a few percent. The philosophy "the model is the calibration" relies upon a complete high-fidelity model of performance and an accurate verification and calibration of this model. As high-resolution x-ray spectroscopy begins to play a more important role in astrophysics, additional issues in accurately calibrating at high spectral resolution become more evident. Here we review the challenges of accurately calibrating the absolute and relative response of x-ray observatories. On-ground x-ray testing by itself is unlikely to achieve a high-accuracy calibration of in-space performance, especially when the performance changes with time. Nonetheless, it remains an essential tool in verifying functionality and in characterizing and verifying the performance model. In the absence of verified cosmic calibration sources, we also discuss the notion of an artificial, in-space x-ray calibration standard. 6th

Weisskopf, Martin C.↗

Development of In-Flow Phased Microphone Array Windscreen Corrections for Small and Large Arrays

The corrections needed in acoustic level measurements using an in-flow phased-array were documented with detailed measurements in the NASA Ames 25- by 18- by 11-Ft Anechoic Chamber for 4 different in-flow arrays fitted with conformal windscreens of stainless-steel wire cloth and Kevlar120 fabric. This study considered the effects of source measurement angle and distance, and the effects of compact vs large distributed broadband calibration-sources. The study verified a simple geometric scaling that accurately derives the windscreen correction for arbitrary incidence angles from the correction measured at normal incidence. The acoustic corrections for windscreens of stainless-steel wire cloth with 200x600 wires/inch were significantly smaller and more regular than for the Kevlar120 windscreen. The qualitative effects of screen tautness were measured and found to be insignificant for the typical assembly specifications at Ames. Correcting phased array peak levels with the measured windscreen corrections created results that compare well with free-field microphone measurements of broadband noise sources.

windscreens↗

Detector Noise Characterization and Performance of MODIS Thermal Emissive Bands

MODIS has 16 thermal emissive bands, a total of 160 individual detectors (10 for each spectral bands), located on the two cold focal plane assemblies (CFPA). MODIS TEB detectors were fully characterized pre-launch in a thermal vacuum (TV) environment using a NIST traceable blackbody calibration source (BCS) with temperatures ranging from 170 to 340K. On-orbit the TEB detectors are calibrated using an on-board blackbody (BB) on a scan-by-scan basis. For nominal on-orbit operation, the on-board BB temperature is typically controlled at 285K for Aqua MODIS and 290K for Terra MODIS. For the MODIS TEB calibration, each detector's noise equivalent temperature difference (NEdT) is often used to assess its performance and this parameter is a major contributor to the calibration uncertainty. Because of its impact on sensor calibration and data product quality, each MODIS TEB detector's NEdT is monitored on a daily basis at a fixed BB temperature and completely characterized on a regular basis at a number of BB temperatures. In this paper, we describe MODIS on-orbit TEB NEdT characterization activities, approaches, and results. We compare both pre-launch and on-orbit performance with sensor design specification and examine detector noise characterization impact on the calibration uncertainty. To date, 135 TEB detectors (out of a total of 160 detectors) in Terra MODIS (launched in December 1999) and 158 in Aqua MODIS (launched in May 2002) continue to perform with their NEdT below (or better than) their design specifications. A complete summary of all TEB noisy detectors, identified both pre-launch and on-orbit, is provided.

Xiong, X.↗

Calibration for the SAGE III/EOS instruments

The calibration plan for the SAGE III instruments for maintaining instrument performance during the Earth Observing System (EOS) mission lifetime is described. The SAGE III calibration plan consists of detailed preflight and inflight calibration on the instrument performance together with the correlative measurement program to validate the data products from the inverted satellite measurements. Since the measurement technique is primarily solar/lunar occultation, the instrument will be self-calibrating by using the sun as the calibration source during the routine operation of the instrument in flight. The instrument is designed to perform radiometric calibration of throughput, spectral, and spatial response in flight during routine operation. Spectral calibration can be performed in-flight from observation of the solar Fraunhofer lines within the spectral region from 290 to 1030 nm wavelength.

Chu, W. P.↗

Test GammaPix™ Radiation Detection Software with Smartphones

GammaPix™ is a smartphone application that uses smartphone cameras to detect ionizing radiation. Brookhaven National Laboratory (BNL) evaluated the performance of the software in detecting radioactive materials. For this purpose, a series of tests were conducted at the Radiation Calibration Facility Annex at BNL. The experiments included dose measurements with three types of NIST-traceable calibration sources, 60Co, 241Am, and 137Cs. The recorded results by GammaPix™ were compared with the values measured by calibrated dosimeters to determine the detection thresholds. Several selected models of iPhones and Android cell phones with different pixel sizes and resolution were tested. In this paper, we present the test procedures and discuss the test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of satellite sensors after launch

A simple and accurate method for the postflight calibration of satellite Visible Infrared Spin-Scan Radiometers (VISSR) is presented, and the results of inflight testing are reported. The calibration source for the VISSR with its effective wavelength of 610 nm is the radiance of sunlight, measured in calibrated reflectance units, scattered by the atmospheric gas above ocean which is far from land. Only the lowest 20 percent of the full-scale VISSR response is calibrated. VISSR testing aboard two geostationary operational evironmental satellites between 1980 and 1983 showed significant calibration coefficient variations of only + or - 12 percent and + or - 2 percent. Good agreement was found between values of aerosol optical thickness measured by VISSR and those measured from the ground.

Fraser, R. S.↗

Precision frequency sources

The development of precision oscillators for time and frequency standards is discussed. The applications of the oscillators to radio communication, research projects, navigation systems, and calibration sources are reported. The status of a cesium beam stabilized oscillator is examined. Photographs of the components are provided. The performance of quartz and rubidium oscillators is compared with the performance of cesium resonators.

Mccoubrey, A. O.↗

Gallium neutrino absorption cross section and its uncertainty

In the recent Baksan Experiment on Sterile Transitions (BEST), a suppressed rate of neutrino absorption on a gallium target was observed, consistent with earlier results from neutrino source calibrations of the SAGE and GALLEX/GNO solar neutrino experiments. The BEST Collaboration, utilizing a 3.4 MCi 51 Cr neutrino source, found observed-to-expected counting rates at two very short baselines of 𝑅 = 0.791 ± 0.05 and 0.766 ± 0.05, respectively. Among recent neutrino experiments, BEST is notable for the simplicity of both its neutrino spectrum, line neutrinos from an electron-capture source whose intensity can be measured to a estimated precision of 0.23%, and its absorption cross section, where the precisely known rate of electron capture to the gallium ground state, 71 Ge ⁢(𝑒−, 𝜈 𝑒 )⁢ 71 Ga ⁢(g.s.), establishes a minimum value. However, the absorption cross section uncertainty is a common systematic in the BEST, SAGE, and GALLEX/GNO neutrino source experiments. Here, in this work, we update that cross section, considering a variety of electroweak corrections and the role of transitions to excited states, to establish both a central value and reasonable uncertainty, thereby enabling a more accurate assessment of the statistical significance of the gallium anomalies. Results are given for 51 Cr and 37 Ar sources. The revised neutrino capture rates are used in a reevaluation of the BEST and gallium anomalies.

electroweak interactions in nuclear physics↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

Gamma ray observations of the Crab pulsar - Past, present, future

The paper describes some of the high-energy observations of the Crab-Nebula pulsar, PSR0531+22. The pulse profiles of the Crab pulsar obtained in balloon-borne observations in 1967 and 1980 are presented. At present, gamma-ray scintillation detectors aboard the Gamma Ray Observatory (GRO) form the basis of the Burst and Transient Source Experiment (BATSE). The pulsar, which is observed daily by the BATSE, is used by all four GRO/BATSE detectors as a calibration source since it emits a steady, strong, well-known spectrum of gamma rays over the entire energy range to which detectors are sensitive. The paper presents an example of a pulse profile obtained with the BATSE.

Fishman, Gerald J.↗

Results and Lessons from MODIS Thermal Emissive Bands Calibration: Pre-launch to On-orbit

MODIS is a major instrument for the NASA EOS Terra (launched in December 1999) and Aqua (launched in May 2002) missions. It was designed and built to enhance and extend its heritage sensors' measurements and data records with applications covering a wide range of studies of the Earth's land, oceans, and atmosphere. Its 16 thermal emissive bands (TEB), each with 10 detectors, are located on the two cold focal plane assemblies (FPAs) controlled by a passive radiative cooler. Because of instrument design complexity and stringent calibration requirements, extensive calibration and characterization activities were conducted pre-launch by the sensor vendor for both Terra and Aqua MODIS. For TEB, these activities include characterization of detectors' noise and non-linearity and evaluation of their radiometric performance in thermal vacuum at difference instrument temperatures and FPA temperatures. In addition TEB system level response versus scan-angle (RVS) and relative spectral response (RSR) were characterized. MODIS TEB radiometric calibration transfer from pre-launch to on-orbit was performed using spectral bands' responses to the instrument on-board blackbody and a laboratory blackbody calibration source (BCS) traceable to NIST standards. This paper provides a summary of MODIS TEB pre-launch and on-orbit calibration and characterization activities, challenges, data analysis results, and lessons learned with focus on sensors' radiometric performance. A comparison between Terra and Aqua MODIS TEB performance is also presented. A similar summary for the reflective solar bands (RSB) is reported in a separate paper in these proceedings.

Xiong, X.↗

New Approach for Temporal Stability Evaluation of Pseudo-Invariant Calibration Sites (PICS)

Pseudo-Invariant Calibration Sites (PICS) are one of the most popular methods for in-flight vicarious radiometric calibration of Earth remote sensing satellites. The fundamental question of PICS temporal stability has not been adequately addressed. However, the main purpose of this work is to evaluate the temporal stability of a few PICS using a new approach. The analysis was performed over six PICS (Libya 1, Libya 4, Niger 1, Niger 2, Egypt 1 and Sudan 1). The concept of a “Virtual Constellation” was developed to provide greater temporal coverage and also to overcome the dependence limitation of any specific characteristic derived from one particular sensor. TOA reflectance data from four sensors consistently demonstrating “stable” calibration to within 5%—the Landsat 7 ETM+ (Enhanced Thematic Mapper Plus), Landsat 8 OLI (Operational Land Imager), Terra MODIS (Moderate Resolution Imaging Spectroradiometer) and Sentinel-2A MSI (Multispectral Instrument)–were merged into a seamless dataset. Instead of using the traditional method of trend analysis (Student’s T test), a nonparametric Seasonal Mann-Kendall test was used for determining the PICS stability. The analysis results indicate that Libya 4 and Egypt 1 do not exhibit any monotonic trend in six reflective solar bands common to all of the studied sensors, indicating temporal stability. A decreasing monotonic trend was statistically detected in all bands, except SWIR 2, for Sudan 1 and the Green and Red bands for Niger 1. An increasing trend was detected in the Blue band for Niger 2 and the NIR band for Libya 1. These results do not suggest abandoning PICS as a viable calibration source. Rather, they indicate that PICS temporal stability cannot be assumed and should be regularly monitored as part of the sensor calibration process.

Tuli, Fatima Tuz Zafrin↗

Effect of Directional Array Size on the Measurement of Airframe Noise Components

A study was conducted to examine the effects of overall size of directional (or phased) arrays on the measurement of aeroacoustic components. An airframe model was mounted in the potential core of an open-jet windtunnel, with the directional arrays located outside the flow in an anechoic environment. Two array systems were used; one with a solid measurement angle that encompasses 31.6 deg.of source directivity and a smaller one that encompasses 7.2 deg. The arrays, and sub-arrays of various sizes, measured noise from a calibrator source and flap edge model setups. In these cases, noise was emitted from relatively small, but finite size source regions, with intense levels compared to other sources. Although the larger arrays revealed much more source region detail, the measured source levels were substantially reduced due to finer resolution compared to that of the smaller arrays. To better understand the measurements quantitatively, an analytical model was used to define the basic relationships between array to source region sizes and measured output level. Also, the effect of noise scattering by shear layer turbulence was examined using the present data and those of previous studies. Taken together, the two effects were sufficient to explain spectral level differences between arrays of different sizes. An important result of this study is that total (integrated) noise source levels are retrievable and the levels are independent of the array size as long as certain experimental and processing criteria are met. The criteria for both open and closed tunnels are discussed. The success of special purpose diagonal-removal processing in obtaining integrated results is apparently dependent in part on source distribution. Also discussed is the fact that extended sources are subject to substantial measurement error, especially for large arrays.

Brooks, Thomas F.↗