Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Efficient and Flexible Sensitivity Matrix Computation for Adaptive Electrical Capacitance Volume Tomography

Electrical capacitance tomography is a widely used sensor modality for flow imaging in many industrial settings. Adaptive Electrical Capacitance Volume Tomography (AECVT) extends the capabilities of traditional ECT by enabling direct volumetric imaging and an improved resolution. Construction of the sensitivity matrix is a necessary step to obtain flow images. This step requires computation of the electric field inside the sensing domain, which is done via a typical field solver such as the finite element method. In this work, we present an efficient and flexible method to construct the sensitivity matrix for Adaptive Electrical Capacitance Volume Tomography (AECVT) based on individual electrode segment excitations and their judicious combination to form desired matrix elements. We illustrate how the proposed method yields the same sensitivity matrix as the traditional method but at a much lower computational cost. Once all segment contributions are obtained, we also indicate how the proposed method, unlike the traditional approach, can generate the sensitivity matrix on demand for an arbitrary combination of synthetic electrodes and obviating the need for any additional field computations. Finally, we present image reconstruction results for two different experimental scenarios where the mutual capacitance data and the corresponding sensitivity vectors are obtained through the proposed measurement combination scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Control Architecture and Sensor Information Development for Process Automation, Optimization, and Imaging of Chemical Looping Systems

The Syngas Chemical Looping (SCL) process developed at The Ohio State University (OSU) uses an iron-based oxygen carrier to convert syngas into high-purity hydrogen while simultaneously capturing carbon dioxide that is readily sequestrable. A 25 kWth sub-pilot unit was successfully demonstrated multiple times on the OSU Clean Coal Research Facility, and a 250 kWth – 3 MWth pilot demonstration unit has been designed and constructed at the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The focus of this project is to develop multiple technologies to automate the startup and shutdown of chemical looping system. Success of this project will propel the advanced carbon capture method toward commercialization, hence be disruptive to the fossil fuel and power industries. Advanced process automation control architecture and imaging and optimization sensor software were developed for OSU chemical looping process. A high-level controller (HLC) consisting of decision-making and controller-selection logic integrated with sliding mode controllers (SMCs) were developed to perform chemical looping process startup and shutdown. Babcock & Wilcox Power Generation Group’s FocalPoint Optimization System was implemented to optimize the process operating conditions. The process automation controller and optimization information were realized and tested on OSU’s existing sub-pilot chemical looping test unit under atmospheric condition. The implemented control architecture was able to perform the complete process procedure from startup, steady-state reaction operation to shutdown with minimal operator intervention. The controller was also implemented on the pressurized syngas chemical looping (SCL) pilot test unit constructed at the National Carbon Capture Center (NCCC), demonstrating its pressure control capability with a designed transient state trajectory. An electrical capacitance volume tomography (ECVT) sensor device and its software were developed to image the packed moving bed and slugging fluidized bed of oxygen carriers in chemical looping systems at elevated temperatures. The ECVT device constructed was capable of tracking the subtle voidage variance along the moving bed axis as a feature for directly measuring the oxygen carrier particles’ linear velocity. Also, the high temperature ECVT device was used to study the fluidization characteristics of Geldart Group D particles.

08 HYDROGEN↗

Investigation of core-annular flow in an industrial scale circulating fluidized bed riser with electrical capacitance volume tomography (ECVT)

There is a paucity of riser data for industrial scale units, particularly with regard to the solids fraction. This is especially true for detailed spatially distributed values. To alleviate this problem, NETL installed a 0.445 m tall electrical capacitance volume tomography (ECVT) sensor 9.66 m from the gas distributor of its industrial size (15.45 m high and 0.3 m diameter) circulating fluidized bed (CFB) cold model. A series of tests were conducted to investigate the gas-solid flow behavior using high density polyethylene (PPE) solids. Static electricity was successfully minimized using Larostat and humidification. Time averaged radial solid fractions profiles are presented and discussed. The time and spatially averaged solid fractions measured by the ECVT agree well with estimates from the pressure drop. The annular thickness was measured and found to increase with increases in the solids flow rate and decrease with increases in the gas velocity. Comparisons of the annular thickness and solids fraction as determined from the ECVT unit were compared to existing correlations. In conclusion, the average error ranged from 13% to 275% which is not surprising since the literature correlations were developed from data on much smaller units and for significantly different particles.

42 ENGINEERING↗

Sensitivity map computation in adaptive electrical capacitance volume tomography with multielectrode excitations

Electrical capacitance tomography (ECT) is a low‐cost, high‐speed imaging technique useful in many industrial settings. ECT is predicated on the knowledge of sensitivity maps between capacitance electrodes that blanket the imaging domain. The simultaneous activation of multiple electrodes can be advantageous to manipulate the resulting field distributions and capture additional spatial information for imaging purposes. However, conventional methods for sensitivity map computation in ECT are not adequate in the presence of multielectrode activation because the mutual coupling between electrodes is not properly accounted for. This coupling becomes especially critical in adaptive electrical capacitance volume tomography (AECVT) sensors, where signals from many small electrode segments are combined into synthetic electrodes. A more general approach is presented for sensitivity map computation in AECVT based on the actual posteriori (induced) charge distributions rather than the conventional approach based on boundary conditions with no account for electrode interactions.

Zeeshan, Z.↗

In-Situ Real Time Monitoring and Control of Mold Making and Filling Processes: Final Report

This project presents a model for addressing several objectives envisioned by the metal casting industries through the integration of research and educational components. It provides an innovative approach to introduce technologies for real time characterization of sand molds, lost foam patterns and monitoring of the mold filling process. The technology developed will enable better control over the casting process. It is expected to reduce scrap and variance in the casting quality. A strong educational component is integrated into the research plan to utilize increased awareness of the industry professional, the potential benefits of the developed technology, and the potential benefits of cross cutting technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ESSENCE- A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules

The rapid, sensitive, and selective detection of target analytes using electrochemical sensors are challenging. ESSENCE, a new Electrochemical Sensor that uses a Shear-Enhanced, flowthrough Nanoporous Capacitive Electrode, overcomes current electrochemical sensors' response limitations, selectivity, and sensitivity limitations. ESSENCE is a microfluidic channel packed with transducer material sandwiched by a top and bottom microelectrode. The room-temperature instrument less integration process allows the switch of the transducer materials to make up the porous electrode without modifying the electrode architecture or device protocol. ESSENCE can be used to detect both biomolecules and small molecules by simply changing the packed transducer material. Electron microscopy results confirm the high porosity. In conjunction with the non-planar interdigitated electrode, the packed transducer material results in a flow-through porous electrode. Electron microscopy results confirm the high porosity. The enhanced shear forces and increased convective fluxes disrupt the electric double layer's (EDL) diffusive process in ESSENCE. This disruption migrates the EDL to high MHz frequency allowing the capture signal to be measured at around 100 kHz, significantly improving device timing (rapid detection) with a low signal-to-noise ratio. The device’s unique architecture allows us multiple configuration modes for measuring the impedance signal. This allows us to use highly conductive materials like carbon nanotubes. We show that by combining single-walled carbon nanotubes as transducer material with appropriate capture probes, NP-µIDE has high selectivity and sensitivity for DNA (fM sensitivity, selective against non-target DNA), breast cancer biomarker proteins (p53, pg/L sensitivity, selective against non-target HER2).

Cheng, Yu-Hsuan↗

Velocity Profiling of a Gas–Solid Fluidized Bed Using Electrical Capacitance Volume Tomography

In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.

47 OTHER INSTRUMENTATION↗

Single-scan measurement of conductance of a quartz crystal microbalance array coupled with resonant markers for biosensing in liquid phase

This work presents a method for sensing the viscoelastic property of liquid/solid interface using a quartz crystal microbalance (QCM) array. Each sensor in a QCM array has a unique resonant frequency and can be identified by a single-scan measurement of admittance (or impedance). The resonant frequency encoding at each sensor in an array was realized by connecting a capacitor with a known capacitance, called a resonant marker, to the sensor in series. Changes in the resonant frequency of all sensors in an array can be determined using an impedance analyzer and a program that determines the frequencies at which the conductance is at a local maximum. The sensing method allows every sensor output (resonant frequency) to be obtained without the use of time-consuming multiplexed hardware and software. Adsorptions of biomolecules by multiple sensor are monitored in the liquid phase to demonstrate the feasibility of frequency encoding using resonant markers and the single-scan measurement of conductance of a QCM array.

36 MATERIALS SCIENCE↗

Structural metamaterials with innate capacitive and resistive sensing

Interpenetrating lattices consist of two or more interwoven but physically separate sub-lattices with unique behaviors derived from their multi-body construction. If the sublattices are constructed or coated with an electrically conducting material, the close proximity and high surface area of the electrically isolated conductors allow the two lattices to interact electromagnetically either across the initial dielectric filled gap or through physical contact. Furthermore, changes in the size of the dielectric gap between the sub-lattices induced by deformation can be measured via capacitance or resistance, allowing a structurally competent lattice to operate as a force or deformation sensor. In addition to resistive and capacitive deformation sensing, this work explores capacitance as a fundamental metamaterial property and the environmental sensing behaviors of interpenetrating lattices.

Computational Solid Mechanics↗

Cross-Plane Acquisitions in Electrical Capacitance Volume Tomography

Electrical capacitance tomography (ECT) is a widely used imaging modality to image two-dimensional cross sections of multiphase flows. Recent developments in electrical capacitance volume tomography (ECVT) have made it possible to directly obtain volumetric images from measured data. An ECVT is instrumental for obtaining accurate phase hold up information and velocity information that are needed for the optimization of certain flow processes. However, compared to ECT, the high correlation between the measurements in ECVT exacerbates the ill-conditioning of the associated image reconstruction problem. Previous studies have suggested that neglecting mutual capacitance data between the ECVT electrodes located at cross-planes that are well separated along the sensor axis can be done without significantly affecting the reconstructed image. In addition, this may help constrain the ill-conditioning of the reconstruction problem. Here, we examine in detail and quantify the effect of reduced cross-plane acquisition strategies for optimizing the image reconstruction and constraining the ill-conditioning of typical ECVT settings.

20 FOSSIL-FUELED POWER PLANTS↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Electromechanical response of piezoelectric thin films subjected to large strain

The use of piezoelectric thin sensors, when subjected to large static strain levels in ultrasonic applications is reported in this paper. A novel flipped beam bending method is proposed to induce static strain level nearing twice the incipient yield strain in the beam material (~0.39%). First, the effect of static large strain on ultrasonic guided wave propagation in the beam was studied using the velocity measurements obtained from a laser Doppler vibrometer. Next, the ultrasonic response of thin sensors is studied under compressive and tensile static strain (±0.72%) with the sensors symmetrically bonded on the lower and upper surfaces, and at the same axial location. The ultrasonic guided wave response to varying levels of static strain is recorded at different center frequencies (50–400 kHz) of the narrow banded ultrasonic excitation. As a case study, the variation of the ultrasonic guided wave response of polyvinylidene difluoride (PVDF) thin sensors with center frequencies at different static strain levels was analyzed and compared with that of lead zirconate titanate (PZT) thin sensors. PZT sensors show a higher variation of sensing performance with strain when compared to PVDF sensors. Apart from static strain, the possible effects on the change in performance of sensors, such as the change in the capacitance is discussed. The characterization method provides a reusable beam arrangement to study the ultrasonic sensor performance at large static strain levels. Characterization at large strain level allows the development of fail-safe sensors even under large strain and permanent plastic deformation of structure on which they are bonded, allowing accurate ultrasonic structural health monitoring even in the presence of damage progression. Piezopolymer sensor like PVDF are least susceptible to static strain due to large yield strain and low modulus and can serve as fail-safe sensors under large strain.

Rathod, Vivek↗

Nanoposition sensors with superior linear response to position and unlimited travel ranges

With the advancement in nanotechnology, the ability of positioning/measuring at subnanometer scale has been one of the most critical issues for the nanofabrication industry and researchers using scanning probe microscopy. Commercial nanopositioners have achieved direct measurements at the scale of 0.01 nm with capacitive sensing metrology. However, the commercial sensors have small dynamic ranges (up to only a few hundred micrometers) and are relatively large in size (centimeters in the transverse directions to the motion), which is necessary for healthy signal detections but making it difficult to use on smaller devices. This limits applications in which large materials (on the scale of centimeters or greater) are handled with needs of subnanometer resolutions. What has been done in the past is to combine the fine and coarse translation stages with different dynamic ranges to simultaneously achieve long travel range and high spatial resolution. In this paper, we present a novel capacitive position sensing metrology with ultrawide dynamic range from subnanometer to literally any practically desired length for a translation stage. This sensor will greatly simplify the task and enhance the performance of direct metrology in a hybrid translational stage covering translation tasks from subnanometer to centimeters.

36 MATERIALS SCIENCE↗

Fabrication of bulk alumina structures with humidity sensing capabilities using direct ink write technique

Purpose The purpose of this study is to evaluate different 3D structures for humidity sensing that will enable the fabrication of complex geometries with high moisture sensitivity. Design/methodology/approach Humidity sensors based on alumina ceramics were fabricated using direct ink write (DIW) technique. Different engineered surface area, polymer binder ratio and post-processing treatment were considered to increase moisture sensitivity. Findings It was found that the binder ratio plays an important role in controlling the rheology of the paste during printing and determining the pore size after post-processing treatment. The sensibility of the fabricated humidity sensor was investigated by measuring its capacitance response toward relative humidity (RH) varying from 40% to 90% RH at 25°C. It is shown that using 3D lattice design, printed alumina humidity sensor could improve sensitivity up to 31.6 pF/RH%, over an order of magnitude higher than solid alumina. Originality/value Most of the alumina humidity sensors available are films in nature because of manufacturing difficulties, which limited its potential of higher sensitivity, and thus broader applications. In this paper, a novel 3D alumina humidity sensor was fabricated using DIW 3D printing technology.

Engineering↗

Longitudinal Resistive Charge Division in Multi-Channel Silicon Strip Sensors

Using a discrete RC network with characteristics approximating those of a high-precision silicon microstrip sensor, we have explored the use of resistive charge division to estimate the position of charge deposition in the direction parallel to the length of the sensor strips. For an electrode with distributed resistance and capacitance of 600 k{Omega} and 12.5 pF, respectively (similar to values expected for a 10 cm long resistive silicon microstrip), we estimate the fractional resolution to be {+-}6.1% of the length of the sensor. We find this value to be independent of resistance, to depend weakly on strip capacitance, and to apply for both isolated single electrodes as well as sensors with multiple parallel electrodes with significant capacitive coupling between electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T Tank Farm Interim Surface Barrier Demonstration - Vadose Zone Monitoring FY09 Report

DOE’s Office of River Protection constructed a temporary surface barrier over a portion of the T Tank Farm as part of the T Farm Interim Surface Barrier Demonstration Project. As part of the demonstration effort, vadose zone moisture is being monitored to assess the effectiveness of the barrier at reducing soil moisture. A solar-powered system was installed to continuously monitor soil water conditions at four locations (i.e., instrument Nests A, B, C, and D) beneath the barrier and outside the barrier footprint as well as site meteorological conditions. Nest A is placed in the area outside the barrier footprint and serves as a control, providing subsurface conditions outside the influence of the surface barrier. Nest B provides subsurface measurements to assess surface-barrier edge effects. Nests C and D are used to assess changes in soil-moisture conditions beneath the interim surface barrier. Each instrument nest is composed of a capacitance probe (CP) with multiple sensors, multiple heat-dissipation units (HDUs), and a neutron probe (NP) access tube. The monitoring results in FY09 are summarized below. The solar panels functioned normally and could provide sufficient power to the instruments. The CP in Nest C after September 20, 2009, was not functional. The CP sensors in Nest B after July 13 and the 0.9-m CP sensor in Nest D before June 10 gave noisy data. Other CPs were functional normally. All the HDUs were functional normally but some pressure-head values measured by HDUs were greater than the upper measurement-limit. The higher-than-upper-limit values might be due to the very wet soil condition and/or measurement error but do not imply the malfunction of the sensors. Similar to FY07 and FY08, in FY09, the soil under natural conditions (Nest A) was generally recharged during the winter period (October-March) and discharged during the summer period (April-September). Soil water conditions above about 1.5-m to 2-m depth from all three types of measurements (i.e., CP, NP and HDU) showed relatively large variation during the seasonal wetting-drying cycle. For the soil below 2-m depth, the seasonal variation of soil water content was relatively small. The construction of the surface barrier was completed in April 2008. In the soil below the surface barrier (Nests C and D), the CP measurements showed that water content at the soil between 0.6-m and 2.3-m depths was very stable, indicating no climatic impacts on soil water condition beneath the barrier. The NP-measured water content showed that soil water drainage seemed occurring in the soil between about 3.4 m (11 ft) and 9.1 m (30 ft) in FY09. The HDU-measured water pressure decreased consistently in the soil above 5-m depth, indicating soil water drainage at these depths of the soil. In the soil below the edge of the surface barrier (Nest B), the CP-measured water content was relatively stable through the year except at the 0.9-m depth; the NP-measured water content showed that soil water drainage was occurring in the soil between about 3.4 m (11 ft) and 9.1 m (30 ft) but at a slightly smaller magnitude than those in Nests C and D; the HDU-measurements show that the pressure head changes in FY09 in Nest B were less than those for C and D but more than those for A. The soil-water-pressure head was more sensitive to soil water regime changes under dry conditions. In the soil beneath the barrier, the theoretical steady-state values of pressure head is equal to the negative of the distance to groundwater table. Hence, it is expected that, in the future, while the water content become stable, the pressure head will keep decreasing for a long time (e.g., many years). These results indicate that the T Tank Farm surface barrier was performing as expected by intercepting the meteoric water from infiltrating into the soil and the soil was becoming drier gradually. The barrier also has some effects on the soil below the barrier edge but at a reduced magnitude.

54 ENVIRONMENTAL SCIENCES↗

Microengineering Pressure Sensor Active Layers for Improved Performance

Abstract Pressure sensors play an integral role in a wide range of applications, such as soft robotics and health monitoring. In order to meet this demand, many groups microengineer the active layer—the layer that deforms under pressure and dictates changes in the output signal—of capacitive, resistive/piezoresistive, piezoelectric, and triboelectric pressure sensors in order to improve sensor performance. Geometric microengineering of the active layer has been shown to improve performance parameters such as sensitivity, dynamic range, limit of detection, and response and relaxation times. There are a wide range of implemented designs, including microdomes, micropyramids, lines or microridges, papillae, microspheres, micropores, and microcylinders, each offering different advantages for a particular application. It is important to compare the techniques by which the microengineered active layers are designed and fabricated as they may provide additional insights on compatibility and sensing range limits. To evaluate each fabrication method, it is critical to take into account the active layer uniformity, ease of fabrication, shape and size versatility and tunability, and scalability of both the device and the fabrication process. By better understanding how microengineering techniques and design compares, pressure sensors can be targetedly designed and implemented.

Ruth, Sara Rachel Arussy↗

Passive absolute age and temperature history sensor

A passive sensor for historic age and temperature sensing, including a first member formed of a first material, the first material being either a metal or a semiconductor material and a second member formed of a second material, the second material being either a metal or a semiconductor material. A surface of the second member is in contact with a surface of the first member such that, over time, the second material of the second member diffuses into the first material of the first member. The rate of diffusion for the second material to diffuse into the first material depends on a temperature of the passive sensor. One of the electrical conductance, the electrical capacitance, the electrical inductance, the optical transmission, the optical reflectance, or the crystalline structure of the passive sensor depends on the amount of the second material that has diffused into the first member.

47 OTHER INSTRUMENTATION↗