Search NASA⌕ Search

SEARCH · Search NASA

Results for “carrier sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Separation of surface and bulk minority-carrier lifetimes in silicon

A photoexcitation technique is suggested which is direct and convenient, requiring little special equipment. No change in the dimensions of the crystal sample is necessary. Although related to the technique of interposing a filter between the light source and the sample, it differs in that the filter is part of the crystal itself. Basically, one of the electrodes is split into two electrodes, one collecting charge from carriers excited in the bulk. This phenomenon in which the carriers follow very closely the electric field lines has been used in position-sensitive semiconductor radiation detectors (Norbeck and Carlson, 1963) but has not been applied to lifetime measurements. In a sense, the split electrode creates a sample without a surface.

Carroll, K. A.↗

Electronic checklists - Evaluation of two levels of automation

Two versions of an electronic checklist have been implemented in the Advanced Concepts Flight Simulator (ACFS) at NASA Research Center. The two designs differ in the degree of pilot involvement in conducting the checklists. One version (manual-sensed), requires the crew to manually acknowledge the completion of each checklist item. The other version (automatic-sensed), automatically indicates completed items without requiring pilot acknowledgement. These two designs and a paper checklist (as a control condition) were evaluated in line oriented simulation. Twelve aircrews from one major air-carrier flew a routine, four leg, short-haul trip. This paper presents and discusses the portion of the experiment that was concerned with measuring the effect of the degree of automation on the crews' performance. It discusses and presents evidence for a potential down-side of implementing an electronic checklist that is designed to provide fully redundant monitoring of human procedure execution and monitoring.

Palmer, Everett↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗

IMU/GPS System Provides Position and Attitude Data

A special navigation system is being developed to provide high-quality information on the position and attitude of a moving platform (an aircraft or spacecraft), for use in pointing and stabilization of a hyperspectral remote-sensing system carried aboard the platform. The system also serves to enable synchronization and interpretation of readouts of all onboard sensors. The heart of the system is a commercially available unit, small enough to be held in one hand, that contains an integral combination of an inertial measurement unit (IMU) of the microelectromechanical systems (MEMS) type, Global Positioning System (GPS) receivers, a differential GPS subsystem, and ancillary data-processing subsystems. The system utilizes GPS carrier-phase measurements to generate time data plus highly accurate and continuous data on the position, attitude, rotation, and acceleration of the platform. Relative to prior navigation systems based on IMU and GPS subsystems, this system is smaller, is less expensive, and performs better. Optionally, the system can easily be connected to a laptop computer for demonstration and evaluation. In addition to airborne and spaceborne remote-sensing applications, there are numerous potential terrestrial sensing, measurement, and navigation applications in diverse endeavors that include forestry, environmental monitoring, agriculture, mining, and robotics.

Lin, Ching Fang↗

Quantum optical memory for entanglement distribution

Optical photons are powerful carriers of quantum information, which can be delivered in free space by satellites or in fibers on the ground over long distances. Entanglement of quantum states over long distances can empower quantum computing, quantum communications, and quantum sensing. Quantum optical memories are devices designed to store quantum information in the form of stationary excitations, such as atomic coherence, and are capable of coherently mapping these excitations to flying qubits. Quantum memories can effectively store and manipulate quantum states, making them indispensable elements in future long-distance quantum networks. Over the past two decades, quantum optical memories with high fidelities, high efficiencies, long storage times, and promising multiplexing capabilities have been developed, especially at the single-photon level. In this review, we introduce the working principles of commonly used quantum memory protocols and summarize the recent advances in quantum memory demonstrations. We also offer a vision for future quantum optical memory devices that may enable entanglement distribution over long distances.

Lei, Yisheng↗

Airborne profiling of ice thickness using a short pulse radar

The acquisition and interpretation of ice thickness data from a mobile platform has for some time been a goal of the remote sensing community. Such data, once obtainable, is of value in monitoring the changes in ice thickness over large areas, and in mapping the potential hazards to traffic in shipping lanes. Measurements made from a helicopter-borne ice thickness profiler of ice in Lake Superior, Lake St. Clair and the St. Clair river as part of NASA's program to develop an ice information system are described. The profiler described is a high resolution, non-imaging, short pulse radar, operating at a carrier frequency of 2.7 GHz. The system can resolve reflective surfaces separated by as little as 10 cm. and permits measurement of the distance between resolvable surfaces with an accuracy of about 1 cm. Data samples are given for measurements both in a static (helicopter hovering), and a traverse mode. Ground truth measurements taken by an ice auger team traveling with the helicopter are compared with the remotely sensed data and the accuracy of the profiler is discussed based on these measurements.

Vickers, R. S.↗

On the optimality of the MAP estimation loop for carrier phase tracking BPSK and QPSK signals

Starting with MAP estimation theory as a basis for optimally estimating carrier phase of BPSK and QPSK modulations, it is shown in this paper that the closed loop phase trackers, which are motivated by this approach, are indeed closed loop optimum in the minimum mean-square phase tracking jitter sense. The corresponding squaring loss performance of these so-called MAP estimation loops is compared with that of more practical implementations wherein the hyperbolic tangent nonlinearity is approximated by simpler functions.

Simon, M. K.↗

Spatiotemporally Registered In-Situ and Ex-Situ Datasets for Laser-based Blown Powder Directed Energy Deposition

This dataset is comprised of in situ sensing data collected during laser-based, blown powder directed energy deposition (DED) of Inconel 718 representing eight different printing conditions: (1) nominal, (2) +15% scan speed, (3) +12% laser power, (4) +42% powder feed rate, (5) +100% jerk limit, (6) +10% layer height, (7) +20% hatch spacing, (8) +20% carrier gas flow. All eight DED builds constructed an identical test coupon geometry consisting of geometric features representative of industrial print requirements (e.g., bulk deposition, thin walls, overhangs). In situ data consists of xyz-coordinates (100 Hz) and on-axis melt pool camera video (60 Hz), both of which have been temporally synchronized to spatially map the melt pool camera data. In addition, post-build X-ray computed tomography (XCT) data for each of the eight test geometries have been spatially registered to the recorded xyz-coordinates, allowing for comparisons between melt pool camera data and flaws identified in the XCT data.

additive manufacturing↗

Modifying Ship Air-Wake Vortices for Aircraft Operations

Columnar-vortex generators (CVG) have been proposed as means to increase the safety of takeoffs and landings of aircraft on aircraft or helicopter carriers and other ships at sea. According to the proposal, CVGs would be installed at critical edge locations on ships to modify the vortices in the air wakes of the ships. The desired effects of modifications are to smooth airflows over takeoff and landing deck areas and divert vortices from takeoff and landing flight paths. With respect to aircraft operations, the wake flows of primary interest are those associated with the bow and side edges of aircraft-carrier decks and with superstructures of ships in general (see Figure 1). The bow and deck-edge vortices can adversely affect airplane and helicopter operations on carriers, while the superstructure wakes can primarily affect operations of helicopters. The concept of the CVG is not new; what is new is the proposed addition of CVGs to ship structures to effect favorable modifications of air wakes. Figure 2 depicts a basic CVG, vertical and horizontal CVGs installed on a simple superstructure, and horizontal CVGs installed on the bow and deck edges. The vertical CVGs would be closed at the deck but open at the top. Each horizontal CVG would be open at both ends. The dimensions of the CVGs installed on the aft edges of the superstructure would be chosen so that the portion of the flow modified by the vertical CVGs would interact synergistically with the portion of the flow modified by the horizontal CVG to move the air wake away from the takeoff-and-landing zone behind the superstructure. The deck-edge CVGs would be mounted flush with, and would extend slightly ahead of the bow of, the flight deck. The overall length of each tube would exceed that of the flight deck. Each deck-edge CVG would capture that portion of the airflow that generates a deck-edge vortex and would generate a columnar vortex of opposite sense to that of the unmodified vortex. The vortex generated by the CVG could be dispersed at its base, thereby removing unwanted turbulence in the path of an approaching airplane. The deck-edge CVGs would promote smooth flow over the entire flight deck. In the case of a Nimitz-class aircraft carrier like that of Figure 1, there would be a CVG on each of the outer edges of the two left portions of the flight deck and a single CVG on the right side of the flight deck. The forward-most CVG on the left side would take the generated vortex underneath the angled flight deck. A CVG could also be installed on the bow of the flight deck to smooth the flow of air onto the flight deck. In the case of wind incident on the deck from an azimuth other than straight ahead, the vortex generated by the bow CVG could, perhaps, be used to feed the CVG(s) of the leeward side edge of the flight deck.

Lamar, John E.↗

Integrated Formation Optical Communication and Estimation System

An architecture has been designed that integrates formation estimation methodologies, precision formation sensing, and high-bandwidth formation communication into a robust, strap-on system that meets knowledge and communication requirements for the majority of planned, precision formation missions. Specifically, the integrated system supports (a) sub-millimeter metrology, (b) multiple greater than 10 Mbps communication channels over a large, 10 deg field-of-view (FOV), and (c) generalized formation estimation methodologies. The sensing sub-system consists of several absolute, metrology gauges with up to 0.1 mm precision that use amplitude-modulated lasers and a LISA-heritage phase meter. Since amplitude modulation is used, inexpensive and robust diode lasers may be used instead of complex, frequency-stabilized lasers such as for nanometer-level metrology. The metrology subsystem laser transceivers consist of a laser diode, collecting optics, and an avalanche photo diode (APD) for detecting incoming laser signals. The APD is necessary since received power is small due to the large (for optical applications) FOV. The phase meter determines the phase of the incoming amplitude modulations as measured by the APD. This phase is equivalent to time-of-flight and, therefore, distance. By placing three laser transceivers on each spacecraft, 18 clock-offset-corrupted distances are calculated. These measurements are communicated and averaged to obtain nine correct distances between the transceivers. From these correct distances, the range and bearing between spacecraft and their relative attitude are determined. Next, communication is integrated on the laser carrier through spectral separation. Metrology amplitude modulations are limited to the 45-50 MHz band, leaving 0-45 MHz for communication. Through careful design of coding scheme, error correction, and filters, six independent 10 Mbps receive channels are possible. Hence, a spacecraft can simultaneously broadcast at 10 Mbps and listen to six other spacecraft. The integrated sensing and communication architecture has been developed, as have formation estimation methodologies that allow the sensing topology to reconfigure as spacecraft maneuver. A bench-top implementation of the integrated sensing and communication architecture is in progress. The final, multiple sensing/communication systems will be tied together via formation estimation algorithms that are also undergoing further development.

Scharf, Daniel↗

Making sense of uncertain nuclear data

At its core, and in an imperfect world, the scientific method relies heavily on the concept of uncertain knowledge. Understanding the nature and magnitude of our lack of knowledge on nuclear data has important ramifications on a wide range of nuclear technologies that encompass defense, energy, medicine, astrophysics, among others. Over the span of a long and fruitful carrier, Dr. Massimo Salvatores has made significant contributions to the fields of nuclear reactor physics, nuclear data, and uncertainty quantification and propagation. Advances in machine learning techniques and computational capabilities are enabling a new level of confidence in our ability to predict key nuclear metrics as well as their associated uncertainties across many applications. Here this short article reviews some of those concepts with an eye towards developing a new paradigm to provide nuclear data libraries of benefit to various applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solid-State Single-Photon Counter

Avalanche photodiode used to detect single photons if cooled to optimum temperature and overbiased beyond breakdown voltage. Offers two to three times sensitvity of photomultiplier tubes commonly used for photon detection. When cooled to reduce number of thermal carriers, avalanche photodiode reverse-biased beyond normal breakdown voltage to give it extremely-high internal gain of 10 to seventh power to 10 to eigth power. Advantages of solid-state devices to applications requiring low-level light detection, optical communication, astronomy, remote sensing, optical metrology, and optical signal processing.

Robinson, D. L.↗

Optimization of microscopic and macroscopic second order optical nonlinearities

Nonlinear optical materials (NLO) can be used to extend the useful frequency range of lasers. Frequency generation is important for laser-based remote sensing and optical data storage. Another NLO effect, the electro-optic effect, can be used to modulate the amplitude, phase, or polarization state of an optical beam. Applications of this effect in telecommunications and in integrated optics include the impression of information on an optical carrier signal or routing of optical signals between fiber optic channels. In order to utilize these effects most effectively, it is necessary to synthesize materials which respond to applied fields very efficiently. In this talk, it will be shown how the development of a fundamental understanding of the science of nonlinear optics can lead to a rational approach to organic molecules and materials with optimized properties. In some cases, figures of merit for newly developed materials are more than an order of magnitude higher than those of currently employed materials. Some of these materials are being examined for phased-array radar and other electro-optic switching applications.

Marder, Seth R.↗

Demonstration of a 4.32 μ m cutoff InAsSbBi n B n photodetector, a lattice-matched random alloy III–V solution for mid-wave infrared sensing

InAsSbBi nBn photodetectors are demonstrated that are lattice-matched to the underlying GaSb substrate with a 4.32 μm wavelength cutoff at 150 K that is 0.3 μm longer than that of lattice-matched InAsSb at this temperature reflecting a 0.5% Bi mole fraction in the InAsSbBi active region. A low growth temperature was utilized to facilitate the incorporation of Bi, resulting in a minority carrier lifetime on the order of 24 ns in the InAsSbBi active region. Nevertheless, the detectors exhibit a quantum efficiency of 17% at 3.3 μm wavelength with a dark current density of 50 μA/cm2 at 150 K and −0.4 V bias and the strong photoresponse turn-on characteristic of a random alloy at 4.32 μm wavelength and 150 K. A shot noise-equivalent irradiance analysis indicates that this detectors' dark-current-limited noise-equivalent irradiance of 1012 cm−2 s−1 is two orders of magnitude greater than the Rule 07 expectation for this cutoff, and dark-current-limited shot noise-equivalent irradiance performance transitions to photon-limited at 1.7 × 1015 photons/cm2 s.

Physics↗

Method of Stamping Surface-Enhance Raman Spectroscopy for Label-Free, Multiplexed, Molecular Sensing and Imaging

The present disclosure relates the use of a stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) plasmonic substrates to produce a label-free, multiplexed molecular sensing and imaging technique. A NPGD SERS substrate is stamped onto a surface containing one or more target molecules, followed by SERS measurement of the target molecules located between the surface and SERS substrate. The target molecules may be deposited on the surface, which may be a carrier substrate such as polydimethylsiloxane (PDMS).

Shih, Wei-Chuan↗

Impact of K-Optimization on Trap Concentration in (Ag,Cu)(In,Ga)Se 2 Solar Cells

Recent progress has been made in improving efficiency in Cu(In,Ga)Se 2 (CIGS) absorbers with steady increases in peak efficiency. One way this has been achieved is by adding Ag to CIGS (ACIGS) to achieve higher V OC . However, these efficiencies are still well below the Shockley-Queisser efficiency limit, and traps acting as recombination centers and compensating centers are one thing limiting the solar efficiency. Past research in CIGS has shown that alkali treatment can improve the efficiency and metastability problems in CIGS, but less is understood about the role of alkali treatments in ACIGS. Here, we investigate the impact of potassium in ACIGS through its impact on trap incorporation and minority carrier lifetime. The samples in this study were grown in a roll-to-roll coater with Mo, ACIGS, CdS, and ZnO structure. Both cells were grown identically except the second (K-optimized) cell was grown with increased K-doping of the Mo contact and was more Cu-poor near the surface to optimize the K profile. This resulted in an efficiency increase from 16.8% to 18.7% for the K-optimized cell, which was mostly due to a 65 mV V OC increase. The doping profile showed a 2X increase in acceptor concentration of the K-optimized cell (2.5×10 15 cm -3 ) which suggests that the K was better incorporated into the ACIGS after these optimizations. To characterize the traps in these cells, deep level transient and optical spectroscopy were used. The DLOS measurements showed an EV+0.98 eV trap whose concentration was reduced 10X in the K-optimized cell (4×10 14 cm -3 ). This is consistent with previous results from the alkali treatment in CIGS, which also showed a decrease in near-conduction band trap concentration [1], but the reduction was larger than previous studies possibly indicating the combination of K and Cu-poor surface may both have aided in reducing the EV+0.98 eV trap concentration. The other primary trap is the mid-gap trap (EV+0.58 eV), which was quantified using DLTS. Its concentration decreased from 9×10 13 cm -3 to 4×10 13 cm -3 in the K-optimized sample, which is a 2X reduction. Previous studies have shown this trap is likely an efficient recombination center [2], which makes sense because it is near mid-gap. This trap has also been associated with V OC instability and reduction, so reducing this trap concentration is essential to achieve high V OC and cell efficiency. To help confirm this association, time-resolved photoluminescence measurements have shown in this sample set and a previous study that the minority carrier lifetime (19 ns baseline to 56 ns K-optimized) and this EV+0.56 eV trap concentration are inversely proportional, which would be expected for a recombination-limited carrier lifetime. The K optimization of ACIGS results in significantly improved cell efficiency and reduced trap concentrations that correlate with the improved material and electrical properties. We will report on this and the impact of the K optimization on the cell metastability.

14 SOLAR ENERGY↗

Large Ca-48 anomalies are associated with Ti-50 anomalies in Murchison and Murray hibonites

Ion microprobe measurements of the Ca isotopic compositions of eight individual hibonite grains from the Ca chondrites Murray and Murchison are reported. Large Ca-48 anomalies two orders of magnitude larger than those observed in normal inclusions and at least a factor of four larger than in the FUN inclusions are found. These anomalies are qualitatively correlated with the Ti-50 anomalies in the sense that the delta Ca-48 and delta Ti-50 values have the same sign. These results confirm previous conclusions concerning the presence of a nucleosynthetic component produced by neutron-rich nuclear statistical equilibrium processes. They suggest the preservation of the isotopic anomalies with interstellar dust grains as carriers of the n-rich Ca and Ti components. The large variation in the delta Ca-48/delta Ti-50 ratios indicates multiple nucleosynthetic components and/or chemical fractionation between Ca and Ti prior to hibonite formation.

Zinner, Ernst K.↗