Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impedances of electrochemically impregnated nickel electrodes as functions of potential, KOH concentration, and impregnation method

Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.

Reid, Margaret A.↗

Absolute integrated intensity for the nu-1 sulfur dioxide band

The absolute integrated intensity of the IR vibration-rotation nu-1 SO2 band was measured using the linear portion of the curve of growth. Infrared spectroscopic-absorption cell measurements were performed on sulfur dioxide at partial pressures less than 0.15 torr with nitrogen added to give a total pressure of 705 torr, the path length being 4 mm. The absolute integrated intensity was determined to be 112.0 plus or minus 2.6/cm/sq (atm cm) at 296 K at the 95% confidence level.

Pilon, P. J.↗

Graphics modelling of non-contact thickness measuring robotics work cell

A system was developed for measuring, in real time, the thickness of a sprayable insulation during its application. The system was graphically modelled, off-line, using a state-of-the-art graphics workstation and associated software. This model was to contain a 3D color model of a workcell containing a robot and an air bearing turntable. A communication link was established between the graphics workstations and the robot's controller. Sequences of robot motion generated by the computer simulation are transmitted to the robot for execution.

Warren, Charles W.↗

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗

Partial Pressures for Several In-Se Compositions from Optical Absorbance of the Vapor

The optical absorbance of the vapor phase over various In-Se compositions between 33.3-60.99 at.% Se and 673-1418 K was measured and used to obtain the partial pressures of Se2(g) and In2Se(g). The results are in agreement with silica Bourdon gauge measurements for compositions between 50-61 at.%, but significantly higher than those from Knudsen cell and simultaneous Knudsen-torsion cell measurements. It is found that 60.99 at.% Se lies outside the sesquiselenide homogeneity range and 59.98 at.% Se lies inside and is the congruently melting composition. The Gibbs energy of formation of the liquid from its pure liquid elements between 1000-1300 K is essentially independent of temperature and falls between -36 to -38 kJ per g atomic weight for 50 and 56% Se at 1200 and 1300 K.

Brebrick, R. F.↗

Solar Cell Calibration and Measurement Techniques

The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WDI 5387, 'Requirements for Measurement and Calibration Procedures for Space Solar Cells' was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and the international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

Bailey, Sheila↗

Solar Cell Calibration and Measurement Techniques

The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

Bailey, Sheila↗

Partial Pressures of In-Se from Optical Absorbance of the Vapor

The optical absorbance of the vapor phase over various In-Se compositions between 33.3 and 61 atomic percent and 673 and 1418K has been measured and used to obtain the partial pressures of Se2(g) and In2Se(g). The results are in agreement with silica Bourdon gage measurements for compositions between 50 and 61 atomic percent but significantly higher than those from Knudsen cell and simultaneous Torsion-Knudsen cell measurements. The sequiselenide is found to sublime incongruently. Congruent vaporization occurs for the liquid above 1000 K between 50.08 and 56 at. percent Se. The Gibbs energy of formation of the liquid from its pure liquid elements between 1000 and 1300K is essentially independent of temperature and falls between -36 and -38 kJ per gram atomic weight for 50 and 56 percent Se at 1200 and 1300K.

Brebrick, R. F.↗

Using Spectral Measurements to Characterize Solar Reference Cells on a Two-Axis Tracker

A study is commencing relating the spectral responsivity of reference cells in the field to changing spectral distribution during the day. Initial results indicate that measurements of the incident spectral distribution can be used to match results of reference cell measurements on a two-axis tracker with a standard deviation of ±0.25% under clear-sky conditions. Initial results are provided. As more data are obtained covering a variety of field conditions and locations, the robustness of these results will be tested. The website https://midcdmz.nrel.gov/apps/sitehome.pl?site=PVRES contains the data generated by this project.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Effects of proton irradiation and temperature on 1 ohm-cm and 10 ohm-cm silicon solar cells

The 1 ohm-cm and 10 ohm-cm silicon solar cells were exposed to 1.0 MeV protons at a fixed flux of 10 to the 9th power P/sq cm-sec and fluences of 10 to the 10th power, 10 to the 11th power, 10 to the 12th power and 3 X 10 to the 12th power P/sq cm. I-V curves of the cells were made at room temperature, 65 C and 165 C after each irradiation. A value of 139.5 mw/sq cm was taken as AMO incident energy rate per unit area. Degradation occurred for both uncovered 1 ohm-cm and 10 ohm-cm cells. Efficiencies are generally higher than those of comparable U.S. cells tested earlier. Damage (loss in maximum power efficiency) with proton fluence is somewhat higher for 10 ohm-cm cells, measured at the three temperatures, for fluences above 2 X 10 to the 11th power P/sq cm. Cell efficiency, as expected, changes drastically with temperature.

Nicoletta, C. A.↗

Tests of Low-Concentration-Ratio Photovoltaic Elements

Report describes performance measurements on elements of low-concentrationratio solar arrays (LCRSA's) employing silicon and gallium arsenide photovoltaic cells. Measurements intended to verify predictions of performance based on mathematical models. Measured and predicted values found to agree closely for both normal and off-normal pointing of array toward Sun.

Mills, M. W.↗

Measurement report: A comparative analysis of an intensive incursion of fluorescing African dust particles over Puerto Rico and another over Spain

Measurements during episodes of African dust, made with two wideband integrated bioaerosol spectrometers (WIBSs), one on the northeastern coast of Puerto Rico and the other in the city of León, Spain, show unmistakable, bioaerosol-like fluorescing aerosol particles (FAPs) that can be associated with these dust episodes. The Puerto Rico event occurred during a major incursion of African dust during June 2020. The León event occurred in the late winter and spring of 2022, when widespread, elevated layers of dust inundated the Iberian Peninsula. Satellite and back-trajectory analyses confirm that dust from northern Africa was the source of the particles during both events. The WIBSs measure the size of individual particles in the range from 0.5 to 30 µm, derive a shape factor, and classify seven types of fluorescence from the FAPs. In general, it is not possible to directly determine the specific biological identity from fluorescence signatures; however, measurements of these types of bioaerosols in laboratory studies allow us to compare ambient fluorescence patterns with whole microbial cells measured under controlled conditions. Here we introduce some new metrics that offer a more quantitative approach for comparing FAP characteristics derived from particles measured under different environmental conditions. The analysis highlights the similarities and differences at the two locations and reveals differences that can be attributed to the age and history of the dust plumes, e.g., the amount of time that the air masses were in the mixed layer and the frequency of precipitation along the air mass trajectory.

54 ENVIRONMENTAL SCIENCES↗

LEIA: An Investigation of Radiation Risks to Biology at the Lunar South Pole

Radiation and reduced gravity pose biological risks to crewed deep space exploration. At the cellular level, radiation damage can be amplified by reduced gravity. Empirical evidence on cellular responses to beyond low Earth orbit (BLEO) environments is imperative to develop effective countermeasures for crew health and in-space biomanufacturing. The Lunar Explorer Instrument for Space Biology Applications (LEIA) project is developing an instrument suite to be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. This presentation will provide an overview of the LEIA hardware, experiments, and mission timeline. The LEIA instruments include the BioSensor, the ARES charged particle detector, and the Mini-FND. The BioSensor is an autonomous light emitting diode (LED)-based spectrophotometer and microfluidic incubator. The BioSensor activates yeast cultures and can measure cell growth, metabolic activity, and carotenoid production. The ARES is a Timepix-based charged particle radiation detector that measures dose, dose rate, and linear energy transfer spectra. The Mini-FND is a fast neutron detector that measures albedo neutron flux and energy spectra. Combined, these instruments will be used for yeast genetics experiments to quantify growth, metabolism, and synthetic biology-enabled production of human nutrients, while taking real time measurements of biologically relevant radiation exposure on the lunar surface. These data will be used to test the importance of selected DNA damage repair and reactive oxygen species defense pathways in mitigating cellular damage from lunar surface radiation.

Yeast↗

LEIA: An Investigation of Radiation Risks to Biology at the Lunar South Pole

Radiation and reduced gravity pose biological risks to crewed deep space exploration. At the cellular level, radiation damage can be amplified by reduced gravity. Empirical evidence on cellular responses to beyond low Earth orbit (BLEO) environments is imperative to develop effective countermeasures for crew health and in-space biomanufacturing. The Lunar Explorer Instrument for Space Biology Applications (LEIA) project is developing an instrument suite to be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. This presentation will provide an overview of the LEIA hardware, experiments, and mission timeline. The LEIA instruments include the BioSensor, the ARES charged particle detector, and the Mini-FND. The BioSensor is an autonomous light emitting diode (LED)-based spectrophotometer and microfluidic incubator. The BioSensor activates yeast cultures and can measure cell growth, metabolic activity, and carotenoid production. The ARES is a Timepix-based charged particle radiation detector that measures dose, dose rate, and linear energy transfer spectra. The Mini-FND is a fast neutron detector that measures albedo neutron flux and energy spectra. Combined, these instruments will be used for yeast genetics experiments to quantify growth, metabolism, and synthetic biology-enabled production of human nutrients, while taking real time measurements of biologically relevant radiation exposure on the lunar surface. These data will be used to test the importance of selected DNA damage repair and reactive oxygen species defense pathways in mitigating cellular damage from lunar surface radiation.

Yeast↗

US terrestrial solar cell calibration and measurement procedures

A workshop was held in the fall of 1976, to evaluate and revise interim terrestrial solar cell calibration and measurement procedures. The revisions made to the interim testing procedures are described. The calibration of reference cells and the design of their holders are covered. Considerations include view angle and optical and thermal matching. Atmospheric factors which affect the calibration and performance of solar cells are discussed. The most critical atmospheric parameter appears to be water vapor. Techniques for matching reference cells to cells or arrays under test are described. Data showing errors in performance under artificial sunlight simulators due to mismatch of reference and test cells are presented. Finally, measurement procedures and data transformations needed to obtain the performance of solar cells and arrays in outdoor natural sunlight are described.

Brandhorst, H. W., Jr.↗

A Multi-Sensor, Low Volume, Automated Culture System for Space Biology Experiments

Optical density (absorbance) is commonly used in microbiology to measure cell concentration and other colorimetric indicators. It is the main type of bioscience data returned from the BioSentinel small spacecraft mission, which was recently launched as a secondary payload on Artemis I. The flight unit takes absorbance measurements of yeast cultures at 570 nm, 630 nm, and 850 nm to track cell concentration and oxidation-reduction (redox) state of the metabolic indicator dye alamarBlue over time [1]. Because the data returned from a small spacecraft mission is necessarily limited, BioSentinel uses a specialized ground-based experiment apparatus to map the absorbance data onto several other parameters. This culture apparatus is composed of a polycarbonate base and lid which contain ports for several commercial sensors, including a standard 12 mm dissolved oxygen probe, gaseous CO2, fluid pressure, and two micro-probes for measuring pH and redox potential. It also contains a pressure relief valve, a rubber membrane for culture interaction, and a 12mm port for the custom optical probe designed to match in-flight measurements. Modules in two corners expand the culture volume into narrow columns, enabling solid-state optical density measurement and dielectric spectroscopy. The apparatus can be fit to a plate for magnetic stirring. The apparatus’s optical probe allows mapping between the flight unit’s optical data and the additional parameters measured by the ground-based experiments. Within the probe, a linear actuator pulls a plunger, drawing culture volume into the optical path. The actuator then pushes out the plunger and culture volume, cleaning any stray yeast from the inside surface of the probe. The probe chassis is 3D-printed from biocompatible resin with the optoelectronics cured inside an optically clear conformal coat which functions as a lens. To optimize the probe’s dimensions, including optical path, a test harness was developed to manipulate and measure distance while the LED light sources and photodiode detector are in operation. The test harness was composed of two 3/64” thick polycarbonate plates mounted to a set of calipers. The LEDs and photodiode were mounted on the outside of each plate. A cuvette of sample fluid was then clamped between the plates in line between the LEDs and photodiode. The test harness generated a 78% signal change between water and a dye standard for the green (570 nm) LED, a 90% signal change for the red (630 nm) LED, and a 25% signal change between water and overgrown yeast for the infrared (850 nm) LED. The improvements to the ground experiment apparatus (culture volume reduction, inclusion of an optical probe to measure flight-like optical data, and magnetic stirring for culture homogeneity) allow for more flight-like measurements to be taken and more accurate mapping of these additional parameters to the optical data returned from the flight unit. This enhancement to mission science return will give insight into how deep space radiation may affect human biology for future long-term space exploration.

Multi-Sensor↗

Long-term Blue Light Effects on the Histology of Lettuce and Soybean Leaves and Stems

Blue light (320 to 496 nm) alters hypocotyl and stem elongation and leaf expansion in short-term, cell-level experiments, but histological effects of blue light in long-term studies of whole plants have not been described. We measured cell size and number in stems of soybean (Glycine max L.) and leaves of soybean and lettuce (Lactuca sativa L.), at two blue light fractions. Short-term studies have shown that cell expansion in stems is rapidly inhibited when etiolated tissue is exposed to blue light. However, under long-term light exposure, an increase in the blue light fraction from less than 0.1% to 26% decreased internode length, specifically by inhibiting soybean cell division in stems. In contrast, an increase in blue light fraction from 6% to 26% reduced soybean leaf area by decreasing cell expansion. Surprisingly, lettuce leaf area increased with increasing blue light fraction (0% to 6%), which was attributed to a 3.1-fold increase in cell expansion and a 1.6-fold increase in cell division.

Dougher, Tracy A. O.↗

How actin crosslinking and bundling proteins cooperate to generate an enhanced cell mechanical response

Actin-crosslinking proteins organize actin filaments into dynamic and complex subcellular scaffolds that orchestrate important mechanical functions, including cell motility and adhesion. Recent mutation studies have shown that individual crosslinking proteins often play seemingly non-essential roles, leading to the hypothesis that they have considerable redundancy in function. We report live-cell, in vitro, and theoretical studies testing the mechanical role of the two ubiquitous actin-crosslinking proteins, alpha-actinin and fascin, which co-localize to stress fibers and the basis of filopodia. Using live-cell particle tracking microrheology, we show that the addition of alpha-actinin and fascin elicits a cell mechanical response that is significantly greater than that originated by alpha-actinin or fascin alone. These live-cell measurements are supported by quantitative rheological measurements with reconstituted actin filament networks containing pure proteins that show that alpha-actinin and fascin can work in concert to generate enhanced cell stiffness. Computational simulations using finite element modeling qualitatively reproduce and explain the functional synergy of alpha-actinin and fascin. These findings highlight the cooperative activity of fascin and alpha-actinin and provide a strong rationale that an evolutionary advantage might be conferred by the cooperative action of multiple actin-crosslinking proteins with overlapping but non-identical biochemical properties. Thus the combination of structural proteins with similar function can provide the cell with unique properties that are required for biologically optimal responses.

Non-NASA Center↗