At least 109 records · Page 6

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

Fuel Cell Power Plant Initiative: Solid Oxide Fuel Cell/Logistics Fuel Processor 27 kWe Power System Demonstration for ARPA - Volume 1

This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.

Veyo, S.E.↗

Application of the SEM to the measurement of solar cell parameters

Techniques are described which make use of the SEM to measure the minority carrier diffusion length and the metallurgical junction depth in silicon solar cells. The former technique permits the measurement of the true bulk diffusion length through the application of highly doped field layers to the back surfaces of the cells being investigated. It is shown that the secondary emission contrast observed in the SEM on a reverse-biased diode can depict the location of the metallurgical junction if the diode has been prepared with the proper beveled geometry. The SEM provides the required contrast and the option of high magnification, permitting the measurement of extremely shallow junction depths.

Weizer, V. G.↗

High-resolution land/ice imaging using Seasat scatterometer measurements

A new method for obtaining high-resolution images (to 4 km) of the land backscatter from low-resolution Seasat-A scatterometer (SASS) measurements is introduced. The method utilizes the measurement cell overlap in multiple spacecraft passes over the region of interest and signal processing techniques to generate high-resolution images of the radar backscatter. The overlap is exploited to estimate the underlying high-resolution surface radar backscatter characteristics using a robust multivariate image reconstruction algorithm. The algorithm has been designed to operate in the high-noise environment typical of scatterometer measurements. The ultimate resolution obtainable is a function of the number of measurements and the measurement overlap. Sample results based on SASS data are provided.

Long, D. G.↗

Towards Simultaneous Multi-Parameter Measurements Using Burst-Mode Frequency-Scanning Planar Laser-Induced Fluorescence

While planar laser-induced fluorescence (PLIF) can provide valuable flow visualization, there are many challenges in extracting quantitative measurements from the fluorescence intensity. To overcome the multi-parameter dependence of the signal intensity, frequency scanning planar laser-induced fluorescence (FS-PLIF) provides the potential for 2D temperature, pressure, and velocity measurements by spectrally resolving the excitation spectrum of one or more fluorescence transitions to extract the Doppler shift, Doppler- and collisional-broadening of absorption lines, and the relative signal intensities of multiple transitions. This work aims to characterize a burst-mode FS-PLIF system consisting of a Spectral Energies, LLC burst-mode laser coupled with a Spectral Energies, LLC optical parametric oscillator using nitric oxide (NO) static pressure cell measurements. The effect of the OPO cavity on intensity fluctuations during frequency-scanning is investigated. A NO PLIF model is implemented to investigate the feasibility of property measurements using single- and two-NO-line scans.

burst-mode laser↗

Two-dimensional high temperature strain measurement system

Two-dimensional optical strain measurements on high temperature test specimens are presented. This two-dimensional capability is implemented through a rotatable sensitive strain axis. Three components of surface strain can be measured automatically, from which the first and second principal strains are calculated. One- and two-dimensional strain measurements at temperatures beyond 750 C with a resolution of 15 microstrain are demonstrated. The system is based on a one-dimensional speckle shift technique. The speckle shift technique makes use of the linear relationship between surface strain and the differential shift of laser speckle patterns in the diffraction plane. Laser speckle is a phase effect that occurs when spatially coherent light interacts with an optically rough surface. Since speckle is generated by any diffusely reflecting surface, no specimen preparation is needed to obtain a good signal. Testing was done at room temperature on a flat specimen of Inconel 600 mounted in a fatigue testing machine. A load cell measured the stress on the specimen before and after acquiring the speckle data. Strain components were measured at 0 C (parallel to the load axis) and at plus or minus 45 C, and plots indicate the calculated values of the first and second principal strains. The measured values of Young's modulus and Poisson's ratio are in good agreement with handbook values. Good linearity of the principal strain moduli at high temperatures indicate precision and stability of the system. However, a systematic error in the high-temperature test setup introduced a scale factor in the slopes of the two-dimensional stress-strain curves. No high temperature effects, however, have been observed to degrade speckle correlation.

Lant, Christian T.↗

Production of Oxygen from Lunar Regolith by Molten Oxide Electrolysis

This paper describes the use of the molten oxide electrolysis (MOE) process for the extraction of oxygen for life support and propellant, and silicon and metallic elements for use in fabrication on the Moon. The Moon is rich in mineral resources, but it is almost devoid of chemical reducing agents, therefore, molten oxide electrolysis is ideal for extraction, since the electron is the only practical reducing agent. MOE has several advantages over other extraction methods. First, electrolytic processing offers uncommon versatility in its insensitivity to feedstock composition. Secondly, oxide melts boast the twin key attributes of highest solubilizing capacity for regolith and lowest volatility of any candidate electrolytes. The former is critical in ensuring high productivity since cell current is limited by reactant solubility, while the latter simplifies cell design by obviating the need for a gas-tight reactor to contain evaporation losses as would be the case with a gas or liquid phase fluoride reagent operating at such high temperatures. Alternatively, MOE requires no import of consumable reagents (e.g. fluorine and carbon) as other processes do, and does not rely on interfacing multiple processes to obtain refined products. Electrolytic processing has the advantage of selectivity of reaction in the presence of a multi-component feed. Products from lunar regolith can be extracted in sequence according to the stabilities of their oxides as expressed by the values of the free energy of oxide formation (e.g. chromium, manganese, Fe, Si, Ti, Al, magnesium, and calcium). Previous work has demonstrated the viability of producing Fe and oxygen from oxide mixtures similar in composition to lunar regolith by molten oxide electrolysis (electrowinning), also called magma electrolysis having shown electrolytic extraction of Si from regolith simulant. This paper describes recent advances in demonstrating the MOE process by a joint project with participation by NASA KSC and MSFC, and Ohio State University and MIT. Progress in measuring cell efficiency for oxygen production, development of non reacting electrodes, and cell feeding and withdrawal will be discussed.

Curreri, Peter A.↗

Thermodynamic Activity Measurements with Knudsen Cell Mass Spectrometry

Coupling the Knudsen effusion method with mass spectrometry has proven to be one of the most useful experimental techniques for studying the equilibrium between condensed phases and complex vapors. The Knudsen effusion method involves placing a condensed sample in a Knudsen cell, a small "enclosure", that is uniformly heated and held until equilibrium is attained between the condensed and vapor phases. The vapor is continuously sampled by effusion through a small orifice in the cell. A molecular beam is formed from the effusing vapor and directed into a mass spectrometer for identification and pressure measurement of the species in the vapor phase. Knudsen cell mass spectrometry (KCMS) has been used for nearly fifty years now and continues to be a leading technique for obtaining thermodynamic data. Indeed, much of the well-established vapor specie data in the JANAF tables has been obtained from this technique. This is due to the extreme versatility of the technique. All classes of materials can be studied and all constituents of the vapor phase can be measured over a wide range of pressures (approximately 10(exp -4) to 10(exp -11) bar) and temperatures (500-2800 K). The ability to selectively measure different vapor species makes KCMS a very powerful tool for the measurement of component activities in metallic and ceramic solutions. Today several groups are applying KCMS to measure thermodynamic functions in multicomponent metallic and ceramic systems. Thermodynamic functions, especially component activities, are extremely important in the development of CALPHAD (Calculation of Phase Diagrams) type thermodynamic descriptions. These descriptions, in turn, are useful for modeling materials processing and predicting reactions such as oxide formation and fiber/matrix interactions. The leading experimental methods for measuring activities are the Galvanic cell or electro-motive force (EMF) technique and the KCMS technique. Each has specific advantages, depending on material and conditions. The EMF technique is suitable for lower temperature measurements, provided a suitable cell can be constructed. KCMS is useful for higher temperature measurements in a system with volatile components. In this paper, we briefly review the KCMS technique and identify the major experimental issues that must be addressed for precise measurements. These issues include temperature measurements, cell material and cell design and absolute pressure calibration. The resolution of these issues are discussed together with some recent examples of measured thermodynamic data.

Copland, Evan H.↗

Systems design study of the Pioneer Venus spacecraft. Appendices to volume 1, sections 8-11 (part 3 of 3)

Power subsystem cost/weight tradeoffs are discussed for the Venus probe spacecraft. The cost estimations of power subsystem units were based upon DSCS-2, DSP, and Pioneer 10 and 11 hardware design and development and manufacturing experience. Parts count and degree of modification of existing hardware were factored into the estimate of manufacturing and design and development costs. Cost data includes sufficient quantities of units to equip probe bus and orbiter versions. It was based on the orbiter complement of equipment, but the savings in fewer slices for the probe bus balance the cost of the different probe bus battery. The preferred systems for the Thor/Delta and for the Atlas/Centaur are discussed. The weights of the candidate designs were based upon slice or tray weights for functionally equivalent circuitry measured on existing hardware such as Pioneers 10 and 11, Intelsat 3, DSCS-2, or DSP programs. Battery weights were based on measured cell weight data adjusted for case weight or off-the-shelf battery weights. The solar array weight estimate was based upon recent hardware experience on DSCS-2 and DSP arrays.

Source record↗

Experimental evaluation of compliant surfaces at low speeds

An experimental study was devised to determine the profile drag on a subsonic wind tunnel model partially covered with various compliant surface materials. The model consisted of a large section of constant thickness bounded fore and aft by symmetric airfoil fairings. A flat rigid plate, the control surface, could be exchanged for four contiguous complaint panels. The flexible media generally consisted of thin polyvinylchloride membranes stretched to various tensions over trapped fluid cavities of air, water, or polyethelene oxide solution, or over dry or flooded open-celled polyurethane foams. On the basis of very accurate direct-force cell measurements, all configurations were found to yield profile drags equal to or slightly higher than that obtained for the conventional rigid surface case. The results indicate that the potential for practical drag-reducing applications will be limited to either high-density or high-speed flows where more sensible pressure perturbations occur.

Mcalister, K. W.↗

Miniature-angular-position transducer

Simple and inexpensive device, using solar cells, measures rapidly-responding active control surfaces of aeroelastically-scaled wind-tunnel models of aircraft. Device allows control surfaces to be measured to within 0.10 deg.

Gray, D. L.↗

Status of the ERDA/NASA photovoltaic tests and applications project

The Tests and Applications Project of the ERDA Photovoltaic Program is concerned with the testing of photovoltaic systems and the growth of their use in real terrestrial applications. This activity is an important complement to the development of low cost solar arrays by providing requirements based on application needs and stimulating markets to create demand to absorb increasing production capacity. A photovoltaic system test facility is now operational, market stimulation has been initiated through applications, and standards for terrestrial cell measurements established.

Deyo, J. N.↗

Automated Coliform Analysis

Hydrogen evolved by coliform bacteria transferred to separate measurement cell. Electroanalytic cell mounted in insulated temperature-control bath cycled between culturing temperature and sterilizing temperature. Flow of materials into and out of cell controlled by electrically operated valves.

Nishioka, K.↗

Maintaining Constant Load Cell Temperature

Thermal insulation and temperature compensation device maintains constant temperature environment for load cells. At constant temperature, cells measure weight accurately and repoducibly.

Van Mark, G. D.↗