Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Two-Dimensional Perovskite Single-Nanowire Photodetectors

High-performance microphotodetectors require materials that combine strong light–matter interaction, fast charge transport, and ambient stability. Here, we demonstrate single-nanowire devices based on the 2D perovskite (TPA3) 2 PbBr 4 , synthesized via a controlled slow-cooling self-assembly process that yields defect-minimized, anisotropic nanowires with smooth facets. These microphotodetectors exhibit ultralow dark currents (∼10 –15 A), high responsivity (up to 156 mA W –1 ), and exceptional specific detectivity (∼10 11 Jones) under near-UV (405 nm) illumination, with rise and fall times in the millisecond regime. The superior detectivity is primarily driven by the suppression of thermal noise through the material’s ultralow dark current, while the millisecond temporal response is governed by high-intensity trap-filling dynamics. The devices maintain stable operation over 4000 s of continuous on/off cycling and show remarkable ambient stability over weeks, attributed to dense crystal packing and robust organic cation layers. Furthermore, the influence of nanowire thickness on the charge collection efficiency is systematically elucidated through optical penetration depth analysis, highlighting design principles for optimizing low-dimensional perovskite photodetectors. This study introduces single 2D perovskite nanowires as a versatile platform for miniaturized, high-performance optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertex dominated superconductivity in intercalated FeSe

Bulk FeSe becomes superconducting below 9 K, but the critical temperature (T c ) is enhanced almost universally by a factor of ~4–5 when it is intercalated with alkali elements. How intercalation modifies the structure is known from in-situ X-ray and neutron scattering techniques, but why T c changes so dramatically is not known. Here we show that there is one-to-one correspondence between the enhancement in magnetic instabilities at certain q vectors and superconducting pairing vertex, even while the nuclear spin relaxation rate 1/(T 1 T) may not reflect this enhancement. Intercalation modifies electronic screening both in the plane and also between layers. We disentangle quantitatively how superconducting pairing vertex gains from each such changes in electronic screening. Intercalated FeSe provides an archetypal example of superconductivity where information derived from the single-particle electronic structure appears to be insufficient to account for the origins of superconductivity, even when they are computed including correlation effects. We show that the five-fold enhancement in T c on intercalation is not sensitive to the exact position of the d xy at Γ point, as long as it stays close to E F . Finally, we show that intercalation also significantly softens the collective charge excitations, suggesting the electron-phonon interaction could play some role in intercalated FeSe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-powered perovskite photon-counting detectors

Metal-halide perovskites (MHPs) have been successfully exploited for converting photons to charges or vice versa in applications of solar cells, light-emitting diodes and solar fuels for which all these applications involve strong light. Here we show that self-powered polycrystalline perovskite photodetectors can rival the commercial silicon photomultipliers (SiPMs) for photon counting. The photon-counting capability of perovskite photon-counting detectors (PCDs) is mainly determined by shallow traps, despite that deep traps also limit charge-collection efficiency. Two shallow traps with energy depth of 5.8 ± 0.8 millielectronvolts (meV) and 57.2 ± 0.1 meV are identified in polycrystalline methylammonium lead triiodide, which mainly stay at grain boundaries and the surface, respectively. We show that these shallow traps can be reduced by grain-size enhancement and surface passivation using diphenyl sulfide, respectively. It greatly suppresses dark count rate (DCR) from >20,000 counts per second per square millimetre (cps mm –2 ) to 2 cps mm –2 at room temperature, enabling much better response to weak light than SiPMs. The perovskite PCDs can collect γ-ray spectra with better energy resolution than SiPMs and maintain performance at high temperatures up to 85 °C. The zero-bias operation of perovskite detectors enables no drift of noise and detection property. Finally, this study opens a new application of photon counting for perovskites that uses their unique defect properties.

47 OTHER INSTRUMENTATION↗

High-field spatial imaging of charge transport in silicon at low temperature

We present direct imaging measurements of charge transport across a 1 cm × 1 cm × 4 mm-thick crystal of high purity silicon (~15 kΩ-cm) at temperatures of 5 K and 500 mK. We use these data to measure lateral diffusion of electrons and holes as a function of the electric field applied along the [111] crystal axis and to verify our low-temperature Monte Carlo software. The range of field strengths in this paper exceed those used in our previous study [R. A. Moffatt et al., Appl. Phys. Lett. 114, 032104 (2019)] by a factor of 10 and now encompass the region in which some recent silicon dark matter detectors operate [R. Agnese et al., Phys. Rev. Lett. 121, 051301 (2018)]. Finally, we also report on a phenomenon of surface charge trapping, which can reduce expected charge collection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High gain, large area, and solar blind avalanche photodiodes based on Al-rich AlGaN grown on AlN substrates

We demonstrate large area (25 000 μm2) Al-rich AlGaN-based avalanche photodiodes (APDs) grown on single crystal AlN substrates operating with differential (the difference in photocurrent and dark current) signal gain of 100 000 at 90 pW (<1 μW cm−2) illumination with very low dark currents <0.1 pA at room temperature under ambient light. The high gain in large area AlGaN APDs is attributed to a high breakdown voltage at 340 V, corresponding to very high breakdown fields ∼9 MV cm−1 as a consequence of low threading and screw dislocation densities < 103 cm−2. The maximum charge collection efficiency of 30% was determined at 255 nm, corresponding to the bandgap of Al0.65Ga0.35N, with a response of 0.06 A/W. No response was detected for λ > 280 nm, establishing solar blindness of the device.

Reddy, Pramod (ORCID:0000000285561178)↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an operando characterization stage for multi-modal synchrotron x-ray experiments

It is widely accepted that micro- and nanoscale inhomogeneities govern the performance of many thin-film solar cell absorbers. These inhomogeneities yield material properties (e.g., composition, structure, and charge collection) that are challenging to correlate across length scales and measurement modalities. The challenge is compounded if a correlation is sought during device operation or in conditions that mimic aging under particular stressors (e.g., heat and electrical bias). Correlative approaches, particularly those based on synchrotron x-ray sources, are powerful since they can access several material properties in different modes (e.g., fluorescence, diffraction, and absorption) with minimal sample preparation. Small-scale laboratory x-ray instruments have begun to offer multi-modality but are typically limited by low x-ray photon flux, low spatial resolution, or specific sample sizes. To overcome these limitations, a characterization stage was developed to enable multi-scale, multi-modal operando measurements of industrially relevant photovoltaic devices. The stage offers compatibility across synchrotron x-ray facilities, enabling correlation between nanoscale x-ray fluorescence microscopy, microscale x-ray diffraction microscopy, and x-ray beam induced current microscopy, among others. Furthermore, the stage can accommodate device sizes up to 25 × 25 mm 2 , offering access to multiple regions of interest and increasing the statistical significance of correlated properties. The stage materials can sustain humid and non-oxidizing atmospheres, and temperature ranges encountered by photovoltaic devices in operational environments (e.g., from 25 to 100 °C). As a case study, we discuss the functionality of the stage by studying Se-alloyed CdTe photovoltaic devices aged in the stage between 25 and 100 °C.

14 SOLAR ENERGY↗

Determining spectral response of the National Ignition Facility particle time of flight diagnostic to x rays

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V –1 mm –1 and b = 0.00 ± 0.04 V –1 . Finally, we also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward achieving cost-effective hexagonal BN semi-bulk crystals and BN neutron detectors via halide vapor phase epitaxy

Presently, thermal neutron detectors fabricated from boron-10 enriched hexagonal boron nitride (h-10BN) ultrawide bandgap semiconductor grown by metal organic chemical vapor deposition (MOCVD) hold the record high detection efficiency among all solid-state detectors at 59%. To overcome the short comings of MOCVD growth, including inherently low growth rate and unavoidable impurities such as carbon in metal organic source, we demonstrate here the growth of natural hexagonal boron nitride (h-BN) semi-bulk wafers using halide vapor phase epitaxy (HVPE), which is an established technique for producing GaN semi-bulk crystals at a high growth rate. Electrical transport characterization results revealed that these HVPE grown materials possess an electrical resistivity of 1 × 1013 Ω cm, and a charge carrier mobility and lifetime product of 2 × 10−4 cm2/V s. Detectors fabricated from a 100 μm thick h-BN wafer have demonstrated a thermal neutron detection efficiency of 20%, corresponding to a charge collection efficiency of ∼60% at an operating voltage of 500 V. This initial demonstration opens the door for mass producing high efficiency h-BN semiconductor neutron detectors at a reduced cost, which could create unprecedented applications in nuclear energy, national security, nuclear waste monitoring and management, the health care industry, and material sciences.

Physics↗

Mitigation of the Brighter-fatter Effect in the LSST Camera

Abstract Thick, fully depleted charge-coupled devices are known to exhibit nonlinear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). The effect results in distorted images of bright calibration stars, creating a flux-dependent point-spread function that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSSTCam before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new method based on a physically motivated model to account for these higher-order terms in the correction, and then we test the modified correction on both data sets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars, which we suggest is the result of sub-pixel physics not included in this correction model. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Measurement of the atmospheric muon rate with the MicroBooNE Liquid Argon TPC

MicroBooNE is a near-surface liquid argon (LAr) time projection chamber (TPC) located at Fermilab. We measure muons originating from cosmic interactions in the atmosphere using both the charge collection and light readout detectors. The data is compared with the cosmic-ray simulation. Agreement is found between the observation, simulation and previous results. Furthermore, the angular resolution of the reconstructed muons inside the TPC is studied in simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single photoelectron identification with Incom LAPPD 38

Incom Inc. Large Area Picosecond Photodetector (LAPPD) 38 has been tested at Jefferson Lab to identify single-photoelectron signals to assess the potential of this type of device for future applications in Cherenkov light detection. Here, single-photoelectron signals were clearly detected if a tight masking of photons impinging on the photocathode was used compared to the pixelation of the charge collection signal board.

47 OTHER INSTRUMENTATION↗

Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m$^{2}$ of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 10$^{15}$ n$_{eq}$/cm$^{2}$. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Investigation of low gain avalanche detectors exposed to proton fluences beyond 10 15 n eq cm -2

Abstract Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs will be subject to 2.5 × 10 15 n eq cm -2 of hadronic fluence during HL-LHC operation; their performance must tolerate this. Hamamatsu Photonics K.K. and Fondazione Bruno Kessler LGADs have been irradiated with 400 and 500 MeV protons respectively in several steps up to 1.5 × 10 15 n eq cm -2 . Measurements of the acceptor removal constants of the gain layers, evolution of the timing resolution and charge collection with damage, and inter-channel isolation characteristics, for a variety of design options, are presented here.

Instruments & Instrumentation↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗