Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge-coupled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Indium antimonide infrared CCD linear imaging arrays with on-chip preprocessing

A description is presented of the fabrication of a new InSb CCD chip based on an improved process which eliminates the limitations inherent with the earlier techniques. This process includes planar junction formation and an aluminum and SiO2 material system which is amenable to state-of-the-art chemical and plasma delineation techniques. Further, the new chip integrates for the first time in monolithic format InSb IR detectors with an InSb CCD. The reported experiments represent the first operation of an InSb infrared CCD array. In addition to fuller characterization of the 20-element charge-coupled infrared imaging device, several factors which influence device performance are currently being addressed. These include surface state density, the CCD output circuit, and storage time (dark current).

Thom, R. D.↗

Application of microprocessors to spacecraft synthetic aperture radar processing

A ground-based digital synthetic aperture radar (SAR) processor capable of correlating images from raw spacecraft data at real-time rates is currently under development. The processor design requirements are particularly formidable due to (1) range migration effects resulting from planetary curvature and rotation, (2) antenna beam pointing errors, and (3) variation of the Doppler reference function with changing orbital parameters. Based upon the current effort, this paper describes a candidate real-time on-board SAR processing implementation approach that might evolve for future spacecraft applications. Key features include the use of custom large scale integration (LSI) charge-coupled device (CCD) technology to accomplish the correlation functions and microprocessor technology to effect control.

Arens, W. E.↗

Autonomous attitude determination systems

A summary of autonomous attitude determination systems is presented by separating it into four areas: types of attitude determination systems which can be automated, a description of the attitude determination problem and its solution, specific types of sensors, and the processor requirements of two automated systems. The sensors used in attitude determination have been characteristically carried on-board the spacecraft in the past, so the major development requirement of automated systems is in the area of on-board processors. It is concluded that standardization of computers is not as beneficial as the standardization of computer architecture and the basic components which go into making them. It is also concluded that charge-coupled devices (CCD) or other solid state star tracking devices offer considerable advantages over the image-dissector type of star tracker.

Lowrie, J. W.↗

Frequency response of charge transfer in MOS inversion layers

The dynamics of charge transfer from a reservoir into an MOS inversion layer, which limits the frequency response of an MOS transistor or a charge-coupled device, is investigated. Using Berman and Kerr's model of space-charge capacitance in the semiconductor, a small-signal distributed model is developed for an MOS structure which transfers charge in an inversion channel due to a variation in the gate voltage. The dynamics of the charge transfer is characterized by a time constant which is determined by the length of the inversion channel and its mobility. Experimental data of gate capacitance vs frequency, taken from a test structure with a diffused source/drain well, are satisfactorily fitted by theoretical curves derived from the model. The channel mobility is precisely determined from the adjusted time constant. The influence of interface states on the capacitance-frequency relationship is also briefly discussed.

Lieneweg, U.↗

Nonmetallic materials contamination studies

In order to impose adequate contamination control requirements in the selection of Wide Field Planetary Camera (WFPC) materials and to develop a data base of potential optical degradation of the WFPC charge-couple device window, the outgassing properties of WFPC materials and the collected volatile condensed material (CVCM) effects on MgF2 transmittance were measured. Changes in the transmittance were monitored in the wavelength region from 115 nm to 300 nm for selected CVCM thicknesses up to 150 nm. The outgassing properties of reemitted CVCM were also studied.

Muscari, J. A.↗

CCD correlated quadruple sampling processor

A correlated quadruple sampling processor for improved signal-to-noise ratio in the output of a charge-coupled device (CCD) is comprised of: switching means for momentarily clamping a CCD signal line at a first reference level A before a CCD data pulse and then obtaining a first data sample B with respect to the reference A during a CCD data pulse, and storing the positive sample B-A; switching means for momentarily clamping the CCD signal line a second time at the level C during the presence of the CCD data pulse and then obtaining a second data sample D with respect to the reference level C after the CCD data pulse, and storing the negative sample D-C; and means for obtaining the difference between the stored samples +(B-A) and -(D-C), thus increasing the net signal amplitude by a factor of about 2 while the noise would be increased by only a factor of square root of 2 since there will be no correlation in the noise between the double samples +(B-A) and -(D-C) effectively added.

Gaalema, S. D.↗

Development of a Shuttle Infrared Telescope Facility /SIRTF/ fine guidance sensor

Fine guidance technology development for the Shuttle Infrared Telescope Facility (SIRTF) centers upon the use of a single multiple-star-tracking sensor to provide the position information necessary to produce three-axis attitude control signals for precision payload pointing. The effort described in this paper is concerned with the development of a fine guidance sensor that employs a high-density charge-coupled imaging device for producing position information signals by using star fields. Multiple star position information produces three-axis position error signals that are used to update inertial reference gyros. The sensor employs advanced position interpolation algorithms to enhance field-of-view resolution and to correct for optical aberrations inherent in spatially chopped star images resulting from the telescope's movable secondary mirror. Operation of the sensor is under the control of a high-performance microcomputer that provides both autonomy and flexibility in a guidance application.

Salomon, P. M.↗

Wideband comet camera lens design

A quarter-meter diameter, modified Ritchey-Chretien camera is described for spacecraft-based observation of Halley's Comet. The system will operate over an unusually broad spectral region, from 0.1216 micron (the hydrogen Lyman-alpha line) to 1.1 microns using reflective primary and secondary mirror optics and a thin UV-grade lithium fluoride refractive element as a field corrector near the image plane. The f/12, 3000 mm focal length camera has a 0.4 deg full field of view for operation with a 15 x 15 mm charge-coupled device detector array. The UV-enhanced silicon CCD detector is a 1000 x 1000 array of 15 micron pixels which establishes the system resolution requirement. The optical design and performance are discussed, with an emphasis on the image analysis with respect to pixel resolution elements used for viewing extended objects such as comets.

Huber, E. D.↗

Detection of the underlying galaxy in the QSO 3C48

Observation of the quasar 3C48 reveals that the faint nebulosity to the north and south of it is dominated by starlight and that the stars have a redshift close to that determined from the broad emission lines in the quasar spectrum. This provides the first direct evidence that a quasar is associated with a galaxy and lies at a distance corresponding to its redshift. The observations were made with a combination of a spectrograph and a charge-coupled device as a detector and took two hours of telescope time. A continuum with absorption features was seen as indicative of a young, hot stellar population. While the redshift of the underlying galaxy is the same as that of the permitted lines in the quasar, it differs from the redshift of the forbidden lines by 500 km/s.

Boroson, T. A.↗

The great galactic centre mystery

Gamma-ray observations of the center of the Galaxy show a varying positron-electron annihilation radiation emission, while at radio wavelengths a non-thermal compact source surrounded by ionized gas moving at high velocities can be seen. Line emission maps for atomic and ionized hydrogen and molecular gas suggest gas expulsion and a massive collapsed object. IR observations show that ionized gas in the central few parsecs of the Galactic center is concentrated in at least 14 small clouds. Charge-coupled device images show a pair of faint, very red sources within a few arc seconds of IRS 16 and the compact non-thermal radio source. The positron-electron annihilation line emission implies an annihilation rate of 10 to the 43rd per sec, compared with an observed luminosity at IR wavelengths of 10 to the 40 erg per sec. Some models are briefly discussed.

Riegler, G. R.↗

Spatially resolved methane band photometry of Saturn. I - Absolute reflectivity and center-to-limb variations in the 6190-, 7250-, and 8900-A bands

Spatially resolved measurements of Saturn's absolute reflectivity in methane bands at 6190, 7250, and 8900 A and in nearby continuum regions are presented. Images were obtained through narrow-band interference filters with a 500 x 500-pixel charge-coupled device. Band/continuum ratios were measured to high accuracy by referencing to the ring brightness in each image. Several data processing techniques enhanced the quality of the observations. These are the use of the ring symmetry to find center position and orientation, accurate subtraction of ring light, and constrained image deconvolution. Uncertainty in the continuum absolute reflectivity is within 10%. Uncertainties in band/continuum ratios are from one to several percent. The Equatorial Zone was much brighter than any other latitude in the strong 8900 band image. Northern midlatitudes were brighter than southern midlatitudes. The latter observation indicates fewer high-altitude aerosols in the south, a possible result of atmospheric dynamics or seasonal sublimation of NH3 crystals. The data are tabulated and presented in a form suitable for quantitative scattering model analyses.

West, R. A.↗

Planetary exploration sensor systems

Most of the instruments that have been used in planetary exploration have been either spectrometers or imaging devices. Instruments of these types are being developed for the Galileo and VOIR (Venus Orbiting Imaging Radar) missions. Galileo will take advantage of new CCD (charge-coupled device) technology, and VOIR will use techniques of synthetic aperture radar developed for Seasat. For determining the macrostructure of mineral resources, the best approach is believed to involve acoustic imaging, essentially a seismic data processing technique. Determinations of microstructure would require a light microscope and an electron microscope. For determining the nature and form of volatiles, a differential scanning calorimeter could be used. To determine the mineral composition, an electron beam microprobe with X-ray fluorescence and spectroscopy would be used.

Saunders, R. S.↗

Multispectral linear array focal plane

A description is provided of a sensor chip array for a unified multispectral focal plane for the Multispectral Linear Array (MLA) instrument. The involved concept of sensing multispectral earth resources imagery through the use of spectral filters deposited directly on a single row of silicon charge-coupled device (CCD) chips has been considered for a number of years. A simplified focal plane was designed after a number of experiments. Technology considerations regarding the design of the multispectral focal plane are discussed. Experimental data are presented which show that the arising problems have been or can be solved.

Hall, J. A.↗

Integrated optics in an electrically scanned imaging Fourier transform spectrometer

An efficient, lightweight and stable, Fourier transform spectrometer was developed. The mechanical slide mechanism needed to create a path difference was eliminated by the use of retro-reflecting mirrors in a monolithic interferometer assembly in which the mirrors are not at 90 degrees to the propagation vector of the radiation, but rather at a small angle. The resulting plane wave fronts create a double-sided inteferogram of the source irradiance distribution which is detected by a charge-coupled device image sensor array. The position of each CCD pixel in the array is an indication of the path difference between the two retro-reflecting mirrors in the monolithic optical structure. The Fourier transform of the signals generated by the image sensor provide the spectral irradiance distribution of the source. For imaging, the interferometer assembly scans the source of irradiation by moving the entire instrument, such as would occur if it was fixedly mounted to a moving platform, i.e., a spacecraft. During scanning, the entrace slot to the monolithic optical structure sends different pixels to corresponding interferograms detected by adjacent columns of pixels of the image sensor.

Breckinridge, James B.↗

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

Brusco, Agustin [Buenos Aires U.]↗

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗