Search NASA⌕ Search

SEARCH · Search NASA

Results for “chromium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Symmetry breaking and self-interaction correction in the chromium atom and dimer

Density functional approximations to the exchange–correlation energy can often identify strongly correlated systems and estimate their energetics through energy-minimizing symmetry-breaking. In particular, the binding energy curve of the strongly correlated chromium dimer is described qualitatively by the local spin density approximation (LSDA) and almost quantitatively by the Perdew–Burke–Ernzerhof generalized gradient approximation (PBE-GGA), where the symmetry breaking is antiferromagnetic for both. Here, we show that a full Perdew–Zunger self-interaction-correction (SIC) to LSDA seems to go too far by creating an unphysical symmetry-broken state, with effectively zero magnetic moment but non-zero spin density on each atom, which lies ~4 eV below the antiferromagnetic solution. A similar symmetry-breaking, observed in the atom, better corresponds to the 3d↑↑4s↑3d↓↓4s↓ configuration than to the standard 3d↑↑↑↑↑4s↑. For this new solution, the total energy of the dimer at its observed bond length is higher than that of the separated atoms. In conclusion, these results can be regarded as qualitative evidence that the SIC needs to be scaled down in many-electron regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating nonlocal heat transport in directly driven chromium spheres using x-ray spectroscopy

We report on experiments investigating heat transport in laser-generated plasmas using directly driven chromium spheres. The spheres are fielded at the OMEGA laser facility and are driven with laser intensities of 5×10 14 Wcm −2 . Plasma conditions in the corona and scattered light are measured experimentally and compared against predictions from two-dimensional (2D) radiation-hydrodynamic simulations using different heat transport models. Spectroscopic analysis of x-ray self-emission is used as an additional diagnostic. X-ray emission is integrated over a large region of the plasma, probing regions that are not observed by localized optical Thomson scattering. In particular, x-ray emission peaks near the plasma critical density, so emission from optically thin lines provides information on plasma conditions where nonlocal transport is most likely to be significant. Three common heat transport models are considered: local transport with flux limiters f = 0.15 and f = 0.03, and the nonlocal Schurtz–Nicolai–Busquet (SNB) model. Consistent with previous work, both the high-flux (f = 0.15) and SNB models show good agreement with experimentally measured plasma conditions in the corona despite overpredicting laser absorption, whereas the low-flux (f = 0.03) model fails to match any experimental data. Conditions inferred from x-ray self-emission line ratios support this conclusion during the period of laser peak power, although synthetic spectra for all models fail to match the experiment during the transient portions of the pulse. For these reasons, the low-flux model is again rejected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetics of solid–liquid interface motion in molecular dynamics and phase-field models: crystallization of chromium and silicon

The results of molecular dynamics (MD) simulations of the crystallization process in one-component materials and solid solution alloys reveal a complex temperature dependence of the velocity of the crystal–liquid interface featuring an increase up to a maximum at 10–30% undercooling below the equilibrium melting temperature followed by a gradual decrease of the velocity at deeper levels of undercooling. At the qualitative level, such non-monotonous behaviour of the crystallization front velocity is consistent with the diffusion-controlled crystallization process described by the Wilson–Frenkel model, where the almost linear increase of the interface velocity in the vicinity of melting temperature is defined by the growth of the thermodynamic driving force for the phase transformation, while the decrease in atomic mobility with further increase of the undercooling drives the velocity through the maximum and into a gradual decrease at lower temperatures. At the quantitative level, however, the diffusional model fails to describe the results of MD simulations in the whole range of temperatures with a single set of parameters for some of the model materials. The limited ability of the existing theoretical models to adequately describe the MD results is illustrated in the present work for two materials, chromium and silicon. It is also demonstrated that the MD results can be well described by the solution following from the hodograph equation, previously found from the kinetic phase-field model (kinetic PFM) in the sharp interface limit. The ability of the hodograph equation to describe the predictions of MD simulation in the whole range of temperatures is related to the introduction of slow (phase field) and fast (gradient flow) variables into the original kinetic PFM from which the hodograph equation is obtained. The slow phase-field variable is responsible for the description of data at small undercoolings and the fast gradient flow variable accounts for local non-equilibrium effects at high undercoolings. The introduction of these two types of variables makes the solution of the hodograph equation sufficiently flexible for a reliable description of all nonlinearities of the kinetic curves predicted in MD simulations of Cr and Si. This article is part of the theme issue ‘Transport phenomena in complex systems (part 1)’.

Science & Technology - Other Topics↗

First-principles study of L -shell iron and chromium opacity at stellar interior temperatures

Recently developed free-energy density functional theory (DFT)-based methodology for optical property calculations of warm dense matter has been applied for studying L-shell opacity of iron and chromium at T = 182 eV. We use Mermin–Kohn–Sham density functional theory with a ground-state and a fully temperature-dependent generalized gradient approximation exchange-correlation (XC) functionals. It is demonstrated that the role of XC at such a high-T is negligible due to the total free-energy of interacting system being dominated by the noninteracting free-energy term in agreement with estimations for the homogeneous electron gas. Furthermore, our DFT predictions are compared to the radiative emissivity and opacity of dense plasmas model, to the real-space Greens function method, and to experimental measurements. Good agreement is found between all three theoretical methods, and in the bound–continuum region for Cr when compared to the experiment, while the discrepancy between direct DFT calculations and the experiment for Fe remains essentially the same as for plasma-physics models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complete genome sequence of Cellulomonas sp., strain ES6, a chromate-reducing bacterium isolated from chromium-contaminated subsurface sediment

ABSTRACT Cellulomonas sp. strain ES6 is a chromate-reducing bacterium isolated from chromium contaminated subsurface sediment. Illumina MiSeq and Oxford Nanopore sequencing were used to assemble the genome sequence which consisted of a single circular chromosome of 4.13 Mb, contained 3,960 protein encoding genes and with an overall G + C content 75.38%.

Perea, Katheryn R.↗

Bismuth Electrocatalyst Enabling Reversible Redox Kinetics of a Chelated Chromium Flow Battery Anolyte

Metal electrocatalysts have been reported to improve the electron transfer kinetics of aqueous redox flow battery electrolytes on various types of carbon electrodes. In this work, we electrodeposited bismuth metal onto a carbon paper anode of a redox flow battery containing our previously reported polyaminocarboxylate-chelated chromium electrolyte. Depositing 0.58 mg cm –2 of bismuth metal enabled an electrochemically reversible electron transfer for the Cr(II)/Cr(III) couple, resulting in a 3.9% voltage efficiency increase over ten cycles at 100 mA cm –2 across an 80% state of charge window, while maintaining >99% current efficiency. The bismuth electrocatalyst provided other improvements, such as a 13% increase in average discharge power density when cycling at 80% energy efficiency, along with a 60% decrease in charge transfer resistance and 12% decrease in the full cell area specific resistance. A chelated bismuth complex was also utilized as a bismuth source for electrodeposition, providing an example of how polyaminocarboxylate ligands can be further implemented into efforts towards improving the energy efficiency of aqueous redox flow batteries.

25 ENERGY STORAGE↗

Transport of Ligand Coordinated Iron and Chromium through Cation-Exchange Membranes

Fluxes of negatively charged ligand-coordinated iron, Fe(CN) 6 3/4- , and chromium, CrPDTA 1/2− , through two promising commercial cation-exchange membranes, Aquivion E87–05S and Fumasep E-620(K), were measured as functions of current density. The magnitude of the partial current density reached a maximum of − 43 μ A cm −2 at the maximum applied current density magnitude of − 43 mA cm −2 for Fe(CN) 6 3/4− transport through Aquivion, or 0.1% of the total current density. Fumasep E-620(K) blocks practically all crossover of both compounds. Both membranes sorb more Fe(CN) 6 3/4− and CrPDTA 1/2− than predicted by Donnan equilibrium, and low crossover rates can be attributed mainly to slow diffusion, not charge-based rejection of co-ions. The magnitude of the diffusion coefficient appears to correlate with hydraulic permeability. Although Aquivion E87–05S and Fumasep E-620(K) have significant and observable differences in membrane crossover rates, cells built with the DI-soaked membranes offer similarly high coulombic efficiency, indicating the relatively small contribution that crossover makes to inefficiency over a single cycle.

25 ENERGY STORAGE↗

The Electrochemical Behavior of As-Prepared Aluminum Alloy A360 Produced by Selective Laser Melting Fabrication with and without a Trivalent Chromium Process Conversion Coating

In this paper, we report on the electrochemical behavior and corrosion resistance of as-prepared aluminum alloy, A360 (AlSi10Mg), fabricated by additive manufacturing, with and without a trivalent chromium process conversion coating. Selective laser melting was the 3D printing process used for the alloy build. The corrosion suppression provided by the coating system was assessed through electrochemical measurements and accelerated degradation testing during a 14-day continuous neutral salt-spray exposure. The results indicate that the conversion coating can be formed by solution pretreating (degreasing and deoxidation) the alloy (X-Z plane perpendicular to the build plane) with its native surface roughness (as-prepared) followed by immersion for 10, 15 or 20 min in the coating bath. All three immersion times provide an equivalent level of corrosion protection to the alloy. The conversion coating suppresses both anodic and cathodic currents, increases the polarization resistance, and provides both anodic and cathodic corrosion protection to the as-prepared alloy. The conversion-coated specimens exhibit good stand-alone corrosion resistance during a 14-day neutral salt-spray exposure with corrosion intensity values (g/m 2 -year) ~10x lower than values for the uncoated, as-prepared alloy specimens.

36 MATERIALS SCIENCE↗

Chromium-Free Coating for Al Alloy Corrosion Protection Based on a Novel Ti/Mg Oxyfluoride

Chromium-free corrosion protection of aluminum alloys comparable to that of chromates (Cr(VI)) is demonstrated using a TiF 6 2– fluoro-anion-based coating recipe containing boric acid and a Mg salt. Boric acid drove TiF 6 2– hydrolysis enabling up to micrometer-scale thick coatings. The Mg salt led to deposition of a novel crystalline phase Ti/Mg oxyfluoride coating with an approximate composition of Ti 5 MgO 7 F 8 . Corrosion protection performance was characterized by polarization resistance measurements during immersion in 5% aqueous NaCl solution and neutral salt fog exposure following ASTM B.117. The performance is discussed in terms of the presence of fluoride in the coating enabling active behavior during its gradual depletion (in corrosion environments) toward a final composition approaching TiO 2 . This active corrosion protection mechanism may be more generally applicable for transition metal-based coatings that do not have high oxidation state oxo-anions, but do have stable fluoro-anions.

36 MATERIALS SCIENCE↗

Characterization of the Sulfur Saturated Versions of the High-Chromium Matrix Glasses

In this report, the Savannah River National Laboratory provides chemical analysis of a series of sulfur saturated melt versions of simulated nuclear waste glasses, and chemical analysis of the wash solutions resulting from the preparation of these glasses. The glasses were selected and fabricated by the Pacific Northwest National Laboratory as part of a broader study of the influence of glass composition on chemical durability, sulfur retention, and other properties. The resulting data will be used in the development of improved property/composition models to support operation of the Hanford Tank Waste Treatment and Immobilization Plant. Some degree of scatter among the Al₂O₃, B₂O₃, CaO, K₂O, Na₂O, and SiO₂ measurements was noted for the study glasses. The measured concentrations of B₂O₃, chlorine, and fluorine were below the targeted values for most of the study glasses, likely because of volatility during the multiple melting steps. The measured concentrations of Cr₂O₃ and K₂O were generally low relative to the targeted values. These components were identified in the wash solutions, indicating partitioning to the excess sulfate phase that was washed from the glasses prior to analyses. As expected, the measured concentrations of SO₃ in the glasses were higher than targeted due to the use of the sulfur saturation method in fabricating these glasses. Minor scatter among the triplicate measurements of some of the analytes of the wash solutions was noted. The wash solutions contained mainly sulfur and sodium, with moderate concentrations of chromium and potassium. Revision 1 of this report corrects the omission of Al₂O₃ values from Table A-4 in Appendix A.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuel Performance Analysis of Chromium-Coated Cladding under Burst Conditions

To reduce the oxidation of zirconium-based alloy cladding at high temperatures, accident tolerant fuel systems have been proposed. Of the concepts identified, chromium-coated cladding has been shown to slow oxidation without greatly impacting the fuel system geometry or neutronic performance. To determine how coated-cladding tubes will perform under high-temperature accident conditions, pressurized-tube burst tests have been performed using the Severe Accident Test Station at Oak Ridge National Laboratory. To begin modeling these tubes to better understand how the coating will impact cladding behavior, these burst tests were simulated with the BISON fuel performance code. Cladding tube surface temperatures for the burst test were developed by fitting thermocouple data into axial and azimuthal profiles, while pressure data were compared until cladding failure. The temperatures at failure and the pressure evolution show relatively good agreement between the simulation and experiment results. This is the first step of a larger effort to simulate the cladding deformation process under high-temperature transient conditions and assess the cladding margin to failure more accurately.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗

Iron-Chromium-Aluminum Accident Tolerant Fuel Concept Source Term Accident Sequence Analysis - High Burnup Fuel Source Term Accident Sequence Analysis Supplement

To extend NUREG-1465 and high burnup fuel source term (SAND2023-01313) recommendations, representative radiological releases to containment – patterned after NUREG-1465 – have been evaluated for LWRs utilizing iron-chromium-aluminum (FeCrAl) alloys in place of zirconium-based alloys in major core structures (cladding and fuel canisters) and high burnup fuel with enrichments of 8% and 10% for PWRs and BWRs, respectively. Representative radionuclide releases are generated for this accident tolerant fuel concept by applying non-parametric bootstrap methods to MELCOR simulation results. Accident scenarios considered in this analysis include principle contributors to historical core damage frequency estimates for a range of nuclear reactor technologies representative of the operating U.S.A. fleet of nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recommendations for Updating Liquid Discharged Inventory and Transport Modeling Parameters for Cumulative Impacts Evaluation of Hexavalent Chromium in the 200 West Area

The purpose of this environmental calculation file (ECF) is to document information regarding hexavalent chromium (Cr(VI)) inventory discharged in 200 West Area at the Hanford Site and provide data to support predictive transport through the vadose zone and saturated zone for modeling efforts. This document provides a focused evaluation of historical waste stream data and studies to develop estimates of Cr(VI) inventory, discharge fractions, and transport parameters for the 200 West Area waste sites and tank farms during discharge events and for long-term contaminant releases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tellurium Corrosion of Type 304/304L Stainless Steel, Iron, Chromium, and Nickel in High-Temperature Liquid Sodium

Investigating tellurium (Te) corrosion on structural materials is crucial for sodium-cooled fast reactors (SFRs) due to radionuclide presence and knowledge gaps. In this study, Type 304/304L stainless steel (SS304), chromium (Cr), iron (Fe), and nickel (Ni) samples were immersed in low-oxygen environments with Te in liquid sodium at 773 K for 30 days. At 10 ppm oxygen, SS304 showed multiple oxide layers, including a compact NaCrO 2 interlayer and porous Na-Fe-Ni-O outer layers. Tellurium penetrated through the porous layers but was hindered by the NaCrO 2 interlayer. At 0.01 ppm oxygen, Cr had no oxide layer, while Fe and Ni had unstable ones. Tellurium-induced pitting was deeper in Fe and Ni compared to Cr. Oxygen levels and Cr composition are critical factors affecting stable oxide compound layer formation and mitigating Te-induced pitting.

36 MATERIALS SCIENCE↗

Chromium-for-Aluminum Substitution in Synthetic Serpentine

Cr-bearing clay minerals are products of hydrothermal alteration and fluid–rock interactions of ultramafic rocks that form serpentine minerals. Cr is typically observed to substitute for Al in serpentine minerals, but the crystal chemistry and environmental constraints on this substitution are unknown. Here, we synthesized endmember and Cr-substituted amesite, a typical Al-serpentine mineral, via the hydrothermal method. We found that the phase purity highly depends on the pH of the hydrothermal solution, which should be controlled at ~12.7 to avoid the formation of impurity phases. Additionally, amesite can incorporate Cr at a concentration equivalent to ~39.5% substitution of Al. The Cr-free and Cr-substituted amesite are highly defective and contain multiple polytypes, including 6R 2 , 2M 1 , and possibly 2H 2 . However, the relative proportions of these polytypes do not change with increasing chromium substitution.

Al-lizardite↗

Bifacial CdTe Solar Cells with Copper Chromium Oxide Back-Buffer Layer

Bifacial solar cells have the potential to maintain energy output higher than monofacial devices under unfavorable weather conditions. A transparent back-buffer layer which can passivate the interface and improve the minority carrier lifetime is critical in CdTe-based bifacial devices. Herein, solution-processed Cu x Cr y O z as a promising back-buffer for CdTe/CdS solar cells is demonstrated. The carrier lifetimes measured at the front and back of the device are 31.2 and 3.1 ns, respectively, which correspond to an increase of ≈38% and 138%, respectively, compared to the reference device. This dramatic improvement in lifetime results in a 100% increase in short-circuit current measured with backside illumination. The best bifacial device has efficiencies 7.6% and 12.5%, respectively, from back and front illumination, yielding a bifaciality factor of 0.60.

14 SOLAR ENERGY↗