Search NASA⌕ Search

SEARCH · Search NASA

Results for “coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Enhancements in Deriving Smoke Emission Coefficients from Fire Radiative Power Measurements

Smoke emissions have long been quantified after-the-fact by simple multiplication of burned area, biomass density, fraction of above-ground biomass, and burn efficiency. A new algorithm has been suggested, as described in Ichoku & Kaufman (2005), for use in calculating smoke emissions directly from fire radiative power (FRP) measurements such that the latency and uncertainty associated with the previously listed variables are avoided. Application of this new, simpler and more direct algorithm is automatic, based only on a fire's FRP measurement and a predetermined coefficient of smoke emission for a given location. Attaining accurate coefficients of smoke emission is therefore critical to the success of this algorithm. In the aforementioned paper, an initial effort was made to derive coefficients of smoke emission for different large regions of interest using calculations of smoke emission rates from MODIS FRP and aerosol optical depth (AOD) measurements. Further work had resulted in a first draft of a 1 1 resolution map of these coefficients. This poster will present the work done to refine this algorithm toward the first production of global smoke emission coefficients. Main updates in the algorithm include: 1) inclusion of wind vectors to help refine several parameters, 2) defining new methods for calculating the fire-emitted AOD fractions, and 3) calculating smoke emission rates on a per-pixel basis and aggregating to grid cells instead of doing so later on in the process. In addition to a presentation of the methodology used to derive this product, maps displaying preliminary results as well as an outline of the future application of such a product into specific research opportunities will be shown.

Ellison, Luke↗

Toward a Combined SAGE II-HALOE Aerosol Climatology: An Evaluation of HALOE Version 19 Stratospheric Aerosol Extinction Coefficient Observations

Herein, the Halogen Occultation Experiment (HALOE) aerosol extinction coefficient data is evaluated in the low aerosol loading period after 1996 as the first necessary step in a process that will eventually allow the production of a combined HALOE/SAGE II (Stratospheric Aerosol and Gas Experiment) aerosol climatology of derived aerosol products including surface area density. Based on these analyses, it is demonstrated that HALOE's 3.46 microns is of good quality above 19 km and suitable for scientific applications above that altitude. However, it is increasingly suspect at lower altitudes and should not be used below 17 km under any circumstances after 1996. The 3.40 microns is biased by about 10% throughout the lower stratosphere due to the failure to clear NO2 but otherwise appears to be a high quality product down to 15 km. The 2.45 and 5.26 micron aerosol extinction coefficient measurements are clearly biased and should not be used for scientific applications after the most intense parts of the Pinatubo period. Many of the issues in the aerosol data appear to be related to either the failure to clear some interfering gas species or doing so poorly. For instance, it is clear that the 3.40micronaerosol extinction coefficient measurements can be improved through the inclusion of an NO2 correction and could, in fact, end up as the highest quality overall HALOE aerosol extinction coefficient measurement. It also appears that the 2.45 and 5.26 micron channels may be improved by updating the Upper Atmosphere Pilot Database which is used as a resource for the removal of gas species otherwise not available from direct HALOE measurements. Finally, a simple model to demonstrate the promise of mixed visible/infrared aerosol extinction coefficient ensembles for the retrieval of bulk aerosol properties demonstrates that a combined HALOE/SAGE II aerosol climatology is feasible and may represent a substantial improvement over independently derived data sets.

Thomason, L. W.↗

CFD Modeling of the Multipurpose Hydrogen Test Bed (MHTB) Self-Pressurization and Spray Bar Mixing Experiments in Normal Gravity: Effect of the Accommodation Coefficient on the Tank Pressure

A CFD model for simulating the self-pressurization of a large scale liquid hydrogen storage tank is utilized in this paper to model the MHTB self-pressurization experiment. The kinetics-based Schrage equation is used to account for the evaporative and condensi ng interfacial mass flows in this model. The effect of the accommodation coefficient for calculating the interfacial mass transfer rate on the tank pressure during tank selfpressurization is studied. The values of the accommodation coefficient which were considered in this study vary from 1.0e-3 to 1.0e-1 for the explicit VOF model and from 1.0e-4 to 1.0e-3 for the implicit VOF model. The ullage pressure evolutions are compared against experimental data. A CFD model for controlling pressure in cryogenic storage tanks by spraying cold liquid into the ullage is also presented. The Euler-Lagrange approach is utilized for tracking the spray droplets and for modeling the interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet-ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux, as well as droplets trajectories, size distribution and temperatures predicted by the model are presented. The ul lage pressure and vapor temperature evolutions are compared with experimental data obtained from the MHTB spray bar mixing experiment. The effect of the accommodation coefficient for calculating the interfacial and droplet mass transfer rates on the tank pressure during mixing of the vapor using spray is studied. The values used for the accommodation coefficient at the interface vary from 1.0e-5 to 1.0e-2. The droplet accommodation coefficient values vary from 2.0e-6 to 1.0e-4.

cryogenic fluid storage↗

Incremental Aerodynamic Coefficient Database for the USA2

In March through May of 2016, a wind tunnel test was conducted by the Aerosciences Branch (EV33) to visually study the unsteady aerodynamic behavior over multiple transition geometries for the Universal Stage Adapter 2 (USA2) in the MSFC Aerodynamic Research Facility's Trisonic Wind Tunnel (TWT). The purpose of the test was to make a qualitative comparison of the transonic flow field in order to provide a recommended minimum transition radius for manufacturing. Additionally, 6 Degree of Freedom force and moment data for each configuration tested was acquired in order to determine the geometric effects on the longitudinal aerodynamic coefficients (Normal Force, Axial Force, and Pitching Moment). In order to make a quantitative comparison of the aerodynamic effects of the USA2 transition geometry, the aerodynamic coefficient data collected during the test was parsed and incorporated into a database for each USA2 configuration tested. An incremental aerodynamic coefficient database was then developed using the generated databases for each USA2 geometry as a function of Mach number and angle of attack. The final USA2 coefficient increments will be applied to the aerodynamic coefficients of the baseline geometry to adjust the Space Launch System (SLS) integrated launch vehicle force and moment database based on the transition geometry of the USA2.

Richardson, Annie Catherine↗

Application of New Partition Coefficients to Modeling Plagioclase

Previously, studies that determined the partition coefficient for an element, i, between plagioclase and the residual basaltic melt (Di plag) have been conducted using experimental conditions dissimilar from the Moon, and thus these values are not ideal for modeling plagioclase fractionation in a lunar system. However, recent work [1] has determined partition coefficients for plagioclase at lunar oxygen fugacities, and resulted in plagioclase with Anorthite contents ≥An90; these are significantly more calcic than plagioclase in previous studies, and the An content has a profound effect on partition coefficient values [2,3]. Plagioclase D-values, which are dependent on the An content of the crystal [e.g., 2-6], can be determined using published experimental data and the correlative An contents. Here, we examine new experimental data from [1] to ascertain their effect on the calculation of equilibrium liquids from Apollo 16 sample 60635,2. This sample is a coarse grained, subophitic impact melt composed of ~55% plagioclase laths with An94.4-98.7 [7,8], distinctly more calcic than of previous partition coefficient studies (e.g., [3-6, 9-10]). Sample 60635,2 is notable as having several plagioclase trace element analyses containing a negative Europium anomaly (-Eu) in the rare-earth element (REE) profile, rather than the typical positive Eu anomaly (+Eu) [7-8] (Fig. 1). The expected +Eu is due to the similarity in size and charge with Ca2+, thereby allowing Eu2+ to be easily taken up by the plagioclase crystal structure, in contrast to the remaining REE3+. Some 60635,2 plagioclase crystals only have +Eu REE profiles, some only have -Eu REE profiles, and some +Eu and -Eu analyses in different areas on a single crystal [7, 8]. Moreover, there does not seem to be any core-rim association with the +Eu or -Eu analyses, nor does there appear to be a correlation between the size, shape, or location of a particular crystal within the sample and the sign of its Eu anomaly, which suggests a complex evolution. In order to investigate this sample further, we can calculate the equilibrium liquids, but with An contents distinct from previous experimental studies, we must calculate the appropriate partition coefficients for each trace element analysis.

Fagan, A. L.↗

Spectral attenuation coefficients from measurements of light transmission in bare ice on the Greenland Ice Sheet

Light transmission into bare glacial ice affects surface energy balance, biophotochemistry, and light detection and ranging (lidar) laser elevation measurements but has not previously been reported for the Greenland Ice Sheet. We present measurements of spectral transmittance at 350–900 nm in bare glacial ice collected at a field site in the western Greenland ablation zone (67.15∘ N, 50.02∘ W). Empirical irradiance attenuation coefficients at 350–750 nm are ∼ 0.9–8.0 m−1 for ice at 12–124 cm depth. The absorption minimum is at ∼ 390–397 nm, in agreement with snow transmission measurements in Antarctica and optical mapping of deep ice at the South Pole. From 350–530 nm, our empirical attenuation coefficients are nearly 1 order of magnitude larger than theoretical values for optically pure ice. The estimated absorption coefficient at 400 nm suggests the ice volume contained a light-absorbing particle concentration equivalent to ∼ 1–2 parts per billion (ppb) of black carbon, which is similar to pre-industrial values found in remote polar snow. The equivalent mineral dust concentration is ∼ 300–600 ppb, which is similar to values for Northern Hemisphere warm periods with low aeolian activity inferred from ice cores. For a layer of quasi-granular white ice (weathering crust) extending from the surface to ∼ 10 cm depth, attenuation coefficients are 1.5 to 4 times larger than for deeper bubbly ice. Owing to higher attenuation in this layer of near-surface granular ice, optical penetration depth at 532 nm is 14 cm (20 %) lower than asymptotic attenuation lengths for optically pure bubbly ice. In addition to the traditional concept of light scattering on air bubbles, our results imply that the granular near-surface ice microstructure of weathering crust is an important control on radiative transfer in bare ice on the Greenland Ice Sheet ablation zone, and we provide new values of flux attenuation, absorption, and scattering coefficients to support model development and validation.

IceSat-2↗

Heat transfer coefficients of moving particle beds from flow-dependent thermal conductivity and near-wall resistance

Accurate determination of heat transfer coefficients for flowing packed particle beds is essential to the design of particle heat exchangers and other thermal and thermochemical equipment. While such dense granular flows mostly fall into the well-known plug-flow regime, the discrete nature of granular materials alters the thermal transport processes in both the near-wall and bulk regions of flowing particle beds from their stationary counterparts. As a result, heat transfer correlations based on the stationary particle bed thermal conductivity could be inadequate for flowing particles in a heat exchanger. Most earlier works have achieved a reasonable agreement with experiments by treating granular heat transfer media as a plug-flow continuum with a near-wall thermal resistance in series. However, the thermal conductivity values of the continuum were often obtained from measurements on stationary beds owing to the difficulty of flowing bed measurements. In this work, it was found that the properties of a stationary bed are highly sensitive to the method of particle packing and there is a decrease in the particle bed thermal conductivity and increase in the near-wall thermal resistance, measured as an effective air gap thickness, on the onset of particle flow. These variations in thermal conductivity of stationary and flowing particle beds can lead to errors in heat transfer coefficient calculations. Therefore, the heat transfer coefficients for granular flows were calculated using experimentally determined flowing particle bed thermal conductivity and near-wall air gap for ceramic particles – CARBO CP 40/100 (mean diameter = 275 µm), HSP 40/70 (404 µm) and HSP 16/30 (956 µm); at velocities of 5–15 mm·s –1 ; and temperatures of 300–650 °C. The thermal conductivity and air gap values for CP 40/100 and HSP 40/70 were further used to calculate heat transfer coefficients across different particle bed temperatures and velocities for different parallel-plate heat exchanger dimensions. Furthermore, these calculations, which show good agreement with measured HTC values reported in literature, can be used as a guide for heat exchanger designs. Graphical abstract

14 SOLAR ENERGY↗

Sticking Coefficients of Fusion Reactor Impurities from Molecular Dynamics Simulations for the Design of Cryopumps

A cryopump can be utilized as an impurity removal component of a direct internal recirculation (DIR) system for the fusion fuel cycle. The DIR facilitates a low fuel inventory by continuously pumping unburnt fuel while removing impurities from the fusion exhaust stream. A cryopump can target multiple impurity species by maintaining a temperature lower than the gas triple-point temperature that promotes desublimation. The desublimation/condensation of gases in cryopumps can be characterized by the sticking coefficient, which is defined as the probability for a gas particle to stick to a (cryo-)surface upon collision. The sticking coefficient is one of the important design/operation parameters for cryopumps, and it depends on a variety of surface and gas properties. Here, in this study, molecular dynamics simulations were utilized to estimate the sticking coefficients of typical fusion gas impurity species N 2 , CO 2 , and CH 4 over a Cu surface for a range of gas temperatures and surface coverages. The molecular dynamics study showed that the sticking coefficients for gases decrease with an increase in gas temperature. The presence of a single full monolayer of condensate on the metallic surface showed an adverse effect on the sticking of gases; however the sticking improved with two full monolayers of condensate on the surface. The sticking of gases over the mixed condensate on a surface was more favorable than the condensate of the same species for N 2 and CH 4 , with an exception for CO 2 , which showed a decrease in sticking over the mixed condensate.

cryopump↗

Charged particle transport coefficient challenges in high energy density plasmas

High energy density physics (HEDP) and inertial confinement fusion (ICF) research typically relies on computational modeling using radiation-hydrodynamics codes in order to design experiments and understand their results. These tools, in turn, rely on numerous charged particle transport and relaxation coefficients to account for laser energy absorption, viscous dissipation, mass transport, thermal conduction, electrical conduction, non-local ion (including charged fusion product) transport, non-local electron transport, magnetohydrodynamics, multi-ion-species thermalization, and electron-ion equilibration. In many situations, these coefficients couple to other physics, such as imposed or self-generated magnetic fields. Furthermore, how these coefficients combine are sensitive to plasma conditions as well as how materials are distributed within a computational cell. Uncertainties in these coefficients and how they couple to other physics could explain many of the discrepancies between simulation predictions and experimental results that persist in even the most detailed calculations. This paper reviews the challenges faced by radiation-hydrodynamics in predicting the results of HEDP and ICF experiments with regard to these and other physics models typically included in simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multitiered computational methodology for extracting three-dimensional rotational diffusion coefficients from x-ray photon correlation spectroscopy data without structural information

X-ray photon correlation spectroscopy (XPCS) is a powerful technique for analyzing particle systems by investigating their dynamics in suspensions across a broad range of temporal and spatial scales. This is done by illuminating samples with coherent x-ray beams and calculating the correlation function of the obtained x-ray scattering images. XPCS is uniquely suited for studying Brownian dynamics, consisting of translational and rotational diffusion. While traditional XPCS image analysis techniques can extract translational diffusion components, they are unable to estimate rotational diffusion coefficients. Here, we introduce a methodology that combines the angular-temporal cross-correlation analysis and a algorithmic framework called Multi-Tiered Estimation for Correlation Spectroscopy in 3D for estimating three-dimensional rotational diffusion coefficients from XPCS images of three-dimensional particle systems. We demonstrate our methodology for extracting rotational diffusion coefficients from XPCS data by applying it to simulated noisy x-ray images of systems of crossing nanotubes and proteins that evolve under translational and rotational Brownian motion for different diffusion rates. Furthermore, our results show that our approach determines rotational diffusion coefficients within a few percent error.

97 MATHEMATICS AND COMPUTING↗

Electronic Band Structure of a Superconducting Nickelate Probed by the Seebeck Coefficient in the Disordered Limit

Superconducting nickelates are a new family of strongly correlated electron materials with a phase diagram closely resembling that of superconducting cuprates. While analogy with the cuprates is natural, very little is known about the metallic state of the nickelates, making these comparisons difficult. We probe the electronic dispersion of thin-film superconducting five-layer ( n = 5 ) and metallic three-layer ( n = 3 ) nickelates by measuring the Seebeck coefficient S . We find a temperature-independent and negative S / T for both n = 5 and n = 3 nickelates. These results are in stark contrast to the strongly temperature-dependent S / T measured at similar electron filling in the cuprate La 1.36 Nd 0.4 Sr 0.24 CuO 4 . The electronic structure calculated from density-functional theory can reproduce the temperature dependence, sign, and amplitude of S / T in the nickelates using Boltzmann transport theory. This demonstrates that the electronic structure obtained from first-principles calculations provides a reliable description of the fermiology of superconducting nickelates and suggests that, despite indications of strong electronic correlations, there are well-defined quasiparticles in the metallic state. Finally, we explain the differences in the Seebeck coefficient between nickelates and cuprates as originating in strong dissimilarities in impurity concentrations. Our study demonstrates that the high elastic scattering limit of the Seebeck coefficient reflects only the underlying band structure of a metal, analogous to the high magnetic field limit of the Hall coefficient. This opens a new avenue for Seebeck measurements to probe the electronic band structures of relatively disordered quantum materials. Published by the American Physical Society 2024

Grissonnanche, G. (ORCID:0000000251153125)↗

Impact of Limited Degree of Freedom Drag Coefficients on a Floating Offshore Wind Turbine Simulation

The worldwide effort to design and commission floating offshore wind turbines (FOWT) is motivating the need for reliable numerical models that adequately represent their physical behavior under realistic sea states. However, properly representing the hydrodynamic quadratic damping for FOWT remains uncertain, because of its dependency on the choice of drag coefficients (dimensionless or not). It is hypothesized that the limited degree of freedom (DoF) drag coefficient formulation that uses only translational drag coefficients causes mischaracterization of the rotational DoF drag, leading to underestimation of FOWT global loads, such as tower base fore-aft shear. To address these hydrodynamic modeling uncertainties, different quadratic drag models implemented in the open-source mid-fidelity simulation tool, OpenFAST, were investigated and compared with the experimental data from the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project. The tower base fore-aft shear and up-wave mooring line tension were compared under an irregular wave loading condition to demonstrate the effects of the different damping models. Two types of hydrodynamic quadratic drag formulations were considered: (1) member-based dimensionless drag coefficients applied only at the translational DoF (namely limited-DoF drag model) and (2) quadratic drag matrix model (in dimensional form). Based on the results, the former consistently underestimated the 95th percentile peak loads and spectral responses when compared to the OC5 experimental data. In contrast, the drag matrix models reduced errors in estimates of the tower base shear peak load by 7–10% compared to the limited-DoF drag model. The underestimation in the tower base fore-aft shear was thus inferred be related to mischaracterization of the rotational pitch drag and the heave motion/drag by the limited-DoF model.

17 WIND ENERGY↗

Satellite-satellite tracking for estimating geopotential coefficients.

Results of simulation studies of tracking of low-altitude satellites by a high-altitude satellite using range measurements between satellites. The high-altitude satellite is tracked by ground-based range trackers. The low-altitude satellites are tracked only by the high-altitude satellites. Orbital elements for one tracking satellite and four tracked low-altitude satellites are estimated, along with a set of low degree and order geopotential coefficients. Estimation of geopotential coefficients of low degree and order is shown to be considerably more accurate using satellite-to-satellite tracking than using ground-based tracking. The use of data from one high-altitude satellite tracking four low-altitude satellites in a range of inclinations is shown to produce geopotential coefficient estimates with smaller errors than presently exist in individual coefficients or would be obtained using ground-based tracking of the same satellites.

Martin, C. F.↗

Estimation of longitudinal aerodynamic coefficients and comparison with wind-tunnel values

Some recent experience at Ames Research Center in the estimation of aerodynamic coefficients for the Lear-Jet and the Augmentor Wing Jet STOL Research Aircraft is reviewed. The coefficients estimated from flight data are compared with values based on large-scale wind-tunnel tests. The results obtained by the regression and quasilinearization identification techniques are also compared. The regression method generally provides the lower standard deviation in the coefficient estimates and provides the better fit to the wind-tunnel values. The addition of nonlinear terms in the aerodynamic equations decreases the difference between the estimated and measured time histories but also increases the standard deviation in the estimated coefficient values.

Wingrove, R. C.↗

Experimental and analytical sonic nozzle discharge coefficients for Reynolds numbers up to 8 x 10 to the 6th power

Sonic discharge coefficients are presented for two different geometry flow nozzles using nitrogen gas at high pressures where real gas corrections are significant. Throat Reynolds number range extended up to 8 million. Experimentally obtained coefficients for a nozzle with a continuous and finite radius of curvature agreed with those obtained analytically to within 0.2 percent. Experimental coefficients for a long radius ASME nozzle agreed to within 1/4 percent to an empirical equation representing the most probable subsonic discharge coefficient.

Szaniszlo, A. J.↗

Design of experiments for measuring heat-transfer coefficients with a lumped-parameter calorimeter

A theoretical investigation was conducted to determine optimum experimental conditions for using a lumped-parameter calorimeter to measure heat-transfer coefficients and heating rates. A mathematical model of the transient temperature response of the calorimeter was used with the measured temperature response to predict the heat-transfer coefficient and the rate of heating. A sensitivity analysis was used to determine the optimum transient experiment for simultaneously measuring the heat addition during heating and the convective heat-transfer coefficient during heating and cooling of a lumped-parameter calorimeter. Optimum experiments were also designed for measuring the convective heat-transfer coefficient during both heating and cooling and cooling only.

Vanfossen, G. J., Jr.↗

Surface heat transfer coefficients of pin-finned cylinders

An experimental investigation was conducted to measure heat-transfer coefficients for a 15.24-centimeter-diameter cylinder with pin fins on its surface. Pin diameters of 0.3175 and 0.6350 centimeter with staggered pin spacings of 3 and 4 pin diameters and pin lengths of 5, 7, and 9 pin diameters were tested. Flow was normal to the axis of the cylinder, and local heat-transfer coefficients were measured as a function of angle around the circumference of the cylinder. The average heat-transfer coefficient was also computed. Reynolds number based on pin diameter ranged from 3600 to 27,750. The smallest diameter, closest spacing, and largest pin-length-to-diameter ratio gave the highest average effective heat-transfer coefficients.

Vanfossen, G. J., Jr.↗

Experimental and analytical sonic nozzle discharge coefficients for Reynolds numbers up to 8,000,000

Sonic discharge coefficients are presented for two different geometry flow nozzles using nitrogen gas at high pressures where real-gas corrections are significant. Throat Reynolds number range extended up to 8,000,000. Experimentally obtained coefficients for a nozzle with a continuous and finite radius of curvature agreed with those obtained analytically to within 0.2 per cent. Experimental coefficients for a long-radius ASME nozzle agreed to within 0.25 per cent to an empirical equation representing the most probable subsonic discharge coefficient.

Szaniszlo, A. J.↗