Search NASA⌕ Search

SEARCH · Search NASA

Results for “collective excitations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NASA’s WB-57F High Altitude Research Aircraft is Looking Up: A Flexible and Capable Heliophysics Platform for Coronal Observations During Total Solar Eclipses

NASA's WB-57F "Canberra" high altitude research aircraft is a unique airborne platform that serves a critical need in airborne science. Although the aircraft has been conventionally used for earth observation/remote sensing and in situ atmospheric sampling, research teams have begun to recognize the aircraft’s emerging role in heliophysics research. With the ability to operate at altitudes in excess of 60,000 feet and with a range of over 2,500 miles, the particular capabilities of the WB-57 are unparalleled by other aircraft in the government or commercial spaces. The Canberra has capacity to carry nearly 9,000 pounds of instrumentation across the aircraft, including modular payload areas in the belly, the nose, wing pods, and wing hatches. The WB-57 features a dedicated "person in the loop" sensor equipment operator, real-time high bandwidth data link between air and ground, and an on-board data network allowing interoperability between multiple systems and operator interfaces. The aircraft has a truly global reach, and has operated out of airfields all over the world with a minimal personnel footprint. The Program maintains a highly qualified engineering team that will work closely with customer requirements to optimize efficiency of payload installation and operation on the aircraft. NASA maintains its own airworthiness authority, allowing a bespoke "in house" approach to aircraft modifications and instrument integration. This often saves months of coordination and cost when compared with commercial options. On 8 April 2024, the WB-57 program executed a one-of-a-kind observation the corona over North America and provided a first-flight opportunity for several instruments that were historically strictly terrestrial. By integrating imagers, spectrometers, and ionosondes on the aircraft, research team partnerships with Southwest Research Institute, University of Hawai’i Institute for Astronomy, and Virginia Tech have demonstrated new and exciting applications for this venerable platform, were able to effectively eliminate the risk of adverse weather spoiling the data collection during totality, and reduce the amount of atmospheric interference in the collected spectral data.

Airborne Science↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

Erosion of an electron-beam front in a long beam-plasma system

The front of an electron beam injected into a uniform, magnetized plasma is observed to erode rapidly because of scattering of the beam electrons via collective beam-plasma interactions. The propagation of the beam front is measured with temporal and axial resolution via beam excitation light. A broadened light front can result that propagates much slower than the injected beam particle speed.

Chan, L. Y.↗

New Dynamic Spin Rig Capabilities Used to Determine Rotating Blade Dynamics

The Dynamic Spin Rig Facility at the NASA Glenn Research Center is used to determine the structural response of rotating engine components without the effects of aerodynamic loading. Recently, this rig's capabilities were enhanced through the replacement of grease-lubricated ball bearings with magnetic bearings. Magnetic bearings offer a number of advantages--the most important here being that they not only fully support the rotor system, but excite it as well. Three magnetic bearings support the rotor and provide five axes of controlled motion: an x- and y-axis translation at each of two radial bearings and a z-axis translation in the vertical or axial direction. Sinusoidal excitation (most commonly used) can be imparted on the rotor through the radial magnetic bearings in either a fixed or rotating frame of reference. This excitation is added directly to the magnetic bearing control output. Since the rotor is fully levitated, large translations and rotations of the rotor system can be achieved. Some of the capabilities of this excitation system were determined and reported. The accelerations obtained at the tip of a titanium flat plate test article versus the swept sine excitation sent to both radial bearings in phase and perpendicular to the plane containing the two blades are shown. Recent tests required the excitation of fundamental bending and torsional blade resonances at rotor speeds up to 10,000 rpm. Successful fixed synchronous rotation of the excitation signal provided the best detectable blade resonant vibrations at excitation frequencies up to 1100 Hz for the particular blades of interest. A noncontacting laser measurement system was used to collect blade-tip motions. From these data, the amplitude and frequency of the motion could be determined as well as the blade damping properties. Damping could be determined using two methods: (1) free decay and (2) curve fitting the vibration amplitude as a function of frequency in and around the resonance of interest and using the half-power method. The free decay of a composite blade vibrating at its first bending resonance while rotating at 3000 rp is shown. This new system is currently being used to support the Efficient Low-Noise Fan project at Glenn. The damping properties of prototype hollow composite blades specially designed to reduce fan noise are currently being determined.

Provenza, Andrew J.↗

GPS World, Innovation: Autonomous Navigation at High Earth Orbits

Calculating a spacecraft's precise location at high orbital altitudes-22,000 miles (35,800 km) and beyond-is an important and challenging problem. New and exciting opportunities become possible if satellites are able to autonomously determine their own orbits. First, the repetitive task of periodically collecting range measurements from terrestrial antennas to high altitude spacecraft becomes less important-this lessens competition for control facilities and saves money by reducing operational costs. Also, autonomous navigation at high orbital altitudes introduces the possibility of autonomous station keeping. For example, if a geostationary satellite begins to drift outside of its designated slot it can make orbit adjustments without requiring commands from the ground. Finally, precise onboard orbit determination opens the door to satellites flying in formation-an emerging concept for many scientific space applications. The realization of these benefits is not a trivial task. While the navigation signals broadcast by GPS satellites are well suited for orbit and attitude determination at lower altitudes, acquiring and using these signals at geostationary (GEO) and highly elliptical orbits is much more difficult. The light blue trace describes the GPS orbit at approximately 12,550 miles (20,200 km) altitude. GPS satellites were designed to provide navigation signals to terrestrial users-consequently the antenna array points directly toward the earth. GEO and HE0 orbits, however, are well above the operational GPS constellation, making signal reception at these altitudes more challenging. The nominal beamwidth of a Block II/IIA GPS satellite antenna array is approximately 42.6 degrees. At GEO and HE0 altitudes, most of these primary beam transmissions are blocked by the Earth, leaving only a narrow region of nominal signal visibility near opposing limbs of the earth. This region is highlighted in gray. If GPS receivers at GEO and HE0 orbits were designed to use these higher power signals only, precise orbit determination would not be practical. Fortunately, the GPS satellite antenna array also produces side lobe signals at much lower power levels. NASA has designed and tested the Navigator, a new GPS receiver that can acquire and track these weaker signals, thereby dramatically increasing the signal visibility at these altitudes. While using much weaker signals is a fundamental requirement for a high orbital altitude GPS receiver, it is certainly not the only challenge. There are other unique characteristics of this application that must also be considered. For example, Position Dilution of Precision (PDOP) figures are much higher at GEO and HE0 altitudes because visible GPS satellites are concentrated in a much smaller area with respect to the spacecraft antenna. These poor PDOP values contribute considerable error to the point solutions calculated by the spacecraft GPS receiver. Finally, spacecraft GPS receivers must be designed to withstand a variety of extreme environmental conditions. Variations in acceleration between launch and booster separation are extreme. Temperature gradients in the space environment are also severe. Furthermore, radiation effects are a major concern-spacecraft-borne GPS receivers must be designed with radiation-hardened electronics to guard against this phenomenon, otherwise they simply will not work. Perhaps most importantly, there are no opportunities to repair or modify any space-borne GPS receiver after it has been launched. Great care must be taken to ensure all performance characteristics have been analyzed prior to liftoff.

Bamford, William↗

Phytoplankton-Fluorescence-Lifetime Vertical Profiler

A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency

Fernandez, Salvador M.↗

An Ontology Driven Information Architecture for Interoperable Disparate Data Sources

The mission of the Planetary Data System is to facilitate achievement of NASA's planetary science goals by efficiently collecting, archiving, and making accessible digital data produced by or relevant to NASA's planetary missions, research programs, and data analysis programs. The vision is: (1) To gather and preserve the data obtained from exploration of the Solar System by the U.S. and other nations (2) To facilitate new and exciting discoveries by providing access to and ensuring usability of those data to the worldwide community (3) To inspire the public through availability and distribution of the body of knowledge reflected in the PDS data collection PDS is a federation of heterogeneous nodes including science and support nodes

planetary data systems↗

Determination of cytoplasmic calcium concentration in Dryopteris spores: a developmentally non-disruptive technique for loading of the calcium indicator fura-2

Germination of Dryopteris spores is mediated by the physiologically active, far-red-absorbing form of phytochrome, Pfr, and external Ca2+ is necessary for the transduction of the light signal. Because knowledge about the cytoplasmic calcium ion concentration, [Ca2+]i, is of great importance for understanding the role of calcium during signal transduction, this value was measured using fura-2 in fern spores undergoing the normal developmental progression into germination. Fura-2 was loaded into the spores by electroporation, which does not disrupt the normal process of germination. The intensity of the fluorescence emission of the loaded fura-2 was analysed by a microspectrophotometric assay of single spores, and successful loading could be obtained by the application of ten electrical pulses (field strength 7.5 kV cm-1, half-life (time constant) 230 microseconds). Fura-2 was alternately excited by light of wavelengths 355 and 385 nm through an inverted fluorescence microscope, and the emitted fura-2 fluorescence was collected by a silicon-intensified video camera. The cytoplasmic calcium ion concentration was calculated from the ratio of the camera output obtained for both wavelengths and displayed by a pseudo-color technique. Spores responded to changes of the extracellular Ca2+ concentration, and this observation is considered as evidence that fura-2 is loaded into the cytoplasm. The substitution of a low external [Ca2+] (1 mM ethyleneglycol-bis(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA)) by 1 mM CaCl2 caused a fast increase of [Ca2+]i from approx. 50 nM to above 500 nM. In contrast, the subsequent substitution of CaCl2 by EGTA decreased [Ca2+]i again below 100 nM within 0.5 h. Furthermore, the application of ionomycin could initiate a change in [Ca2+]i according to the Ca2+ gradient established between the extracellular medium and cytoplasm. In spores sown on a Ca(2+) -free medium, [Ca2+]i, analysed in a buffer containing EGTA, was found to be around 50 nM during the first days of cultivation, independent of the irradiation protocol. However, if spores were grown in darkness on a Ca(2+) -containing medium and analysed in EGTA, [Ca2+]i was significantly higher (> or = 500 nM). In red-light-irradiated spores, [Ca2+]i was found to decrease with increasing time after irradiation, and was determined to be less than 100 nM when analysis was done 44 h after germination was initiated by the light treatment.

NASA Discipline Plant Biology↗

Aircraft Fault Detection Using Real-Time Frequency Response Estimation

A real-time method for estimating time-varying aircraft frequency responses from input and output measurements was demonstrated. The Bat-4 subscale airplane was used with NASA Langley Research Center's AirSTAR unmanned aerial flight test facility to conduct flight tests and collect data for dynamic modeling. Orthogonal phase-optimized multisine inputs, summed with pilot stick and pedal inputs, were used to excite the responses. The aircraft was tested in its normal configuration and with emulated failures, which included a stuck left ruddervator and an increased command path latency. No prior knowledge of a dynamic model was used or available for the estimation. The longitudinal short period dynamics were investigated in this work. Time-varying frequency responses and stability margins were tracked well using a 20 second sliding window of data, as compared to a post-flight analysis using output error parameter estimation and a low-order equivalent system model. This method could be used in a real-time fault detection system, or for other applications of dynamic modeling such as real-time verification of stability margins during envelope expansion tests.

Grauer, Jared A.↗

Improved Underwater Excitation-Emission Matrix Fluorometer

A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.

Moore, Casey↗

Nonlocal and collective relaxation in stellar systems

The modal response of stellar systems to fluctuations at large scales is presently investigated by means of analytic theory and n-body simulation; the stochastic excitation of these modes is shown to increase the relaxation rate even for a system which is moderately far from instability. The n-body simulations, when designed to suppress relaxation at small scales, clearly show the effects of large-scale fluctuations. It is predicted that large-scale fluctuations will be largest for such marginally bound systems as forming star clusters and associations.

Weinberg, Martin D.↗

Generating Excitement and Increasing Awaressness of NASA Planetary Science and Astromaterials Assets

Students, educators, the public, and the scientific community are so often inspired by NASA science and exploration. Millions have joined NASA during live mission event broadcasts and also follow NASA on social media. Exploration of worlds in our solar system enable the scientific community to obtain and analyze data that provide clues to better understand the history and evolution of our solar system. Missions that collect and return samples to Earth from a target solar system body provide scientists with samples they can research and analyze in their laboratories. For those who are not planetary scientists, they may not understand the significance of these samples and/or the importance of sample return missions. The Astromaterials Research and Exploration Science (ARES) Science Engagement team, through work supported by NASA’s Science Mission Directorate (SMD) Science Education Cooperative Agreement Notice NNH15ZDA004C, provides access to samples from NASA’s Astromaterials Collections through NASA sponsored exhibits at educator and scientific conferences, NASA relevant public outreach events, and collaborations with other Science Activation Teams supported by the SMD Cooperative Agreement Notice. The goal of this work is to generate excitement while enhancing knowledge and awareness of NASA’s unique assets, thus highlighting NASA planetary science and exploration.

Graff, P. V.↗

Improved Raman-Emission Detector

Improved apparatus excites and detects Raman emissions in sample gas mixture to measure concentration of species. Sensitivity increased by novel design features as increasing collection of emissions using paraboloidal reflector and collecting lens coaxial with beam instead of spherical reflector and condensing lens on axis perpendicular to illuminating beam.

Mckinney, Gary N.↗

Diagnostics of Laser Produced Plume Under Carbon Nanotube Growth Conditions

This paper presents diagnostic data obtained from the plume of a graphite composite target during carbon nanotube production by the double-pulse laser oven method. The insitu emission spectrum (300 to 650 nm) is recorded at different locations upstream of the target and at different delay times from the lasers (IR and green). Spectral features are identified as emissions from C2 (Swan System: a (sup 3)pi(sub g) - delta (sup 3)pi(sub u) and C3 (Comet Head System: A (sup 1)pi(sub u) - chi (sup 1)sigma(sub u) (sup +). Experimental spectra are compared with computed spectra to estimate vibrational temperatures of excited state C2 in the range of 2500 to 4000 kappa The temporal evolution of the 510 nm band of C2 is monitored for two target positions in various locations which shows confinement of the plume in the inner tube and increase in plume velocity with temperature. The excitation spectra of C2 are obtained by using a dye laser to pump the (0,1) transition of the Swan System and collecting the Laser Induced Fluorescence signal from C2 These are used to obtain "ground-state" rotational and vibrational temperatures which are close to the oven temperature. Images of the plume are also collected and are compared with the spectral measurements.

Arepalli, Sivaram↗

A Unique Style of Alteration of Iron-Nickel Metal in WIS91600, an Unusual C2 Carbonaceous Chondrite

The collection of meteorites from Antarctica has provided an invaluable resource of new materials for study by the scientific community. In addition to exciting finds of new meteorite types (e.g. ALH85085, LEW 85332), these efforts have generated many important samples of existing meteorite groups, particularly C2 chondrites. Studies of these chondrites have broadened our understanding of aqueous alteration and provided a much more comprehensive view of the diversity of alteration in these meteorites. In this study, I report the findings of a petrographic and TEM study of WIS91600, a C2 chondrite that has experienced a highly unusual style of aqueous alteration that has not previously been recognized in C2 chondrites.

Brearley, Adrian J.↗

Reliable Ignition of LOX Methane Propellants in Thermal Vacuum Environment

The goal of this project is to demonstrate reliable ignition of liquid oxygen-liquid methane at thermal vacuum conditions using a coil-on-plug (COP) sparking exciter. Testing will be performed using EP’s Frost-Mint cryogenic propellant test stand, using an engine updated based on data collected from previous engine testing at Plum Brook Station, to determine conditions under which the cryogenic propellants will consistently and reliably ignite. In FY22 the project successfully completed the following milestones. The cryogenic test stand Frost-Mint was upgraded to include an integrated vacuum tube and liquid nitrogen cooling system enabling cold vacuum ignition testing. The Integrated GN2/LN2 Ultra-Low-temperature Enclosure (IGLUE), a custom-built close-coupled heater exchanger shroud was designed, fabricated, tested and integrated into the test stand. The vacuum tube and IGLUE enabled the thruster body and propellants to be conditioned to temperatures and pressures desired. This work recreated the no-light conditions experienced during vehicle-level thermal vacuum testing and obtained thruster performance data and ignition imagery.

liquid oxygen↗

Context Imaging Raman Spectrometer

Methods and systems for Raman spectroscopy and context imaging are disclosed. One or two lasers can be used to excite Raman scattering in a sample, while a plurality of LEDs can illuminate the sample at a different wavelength. The LED light is collected by a lenslet array in order to enable a high depth of field. Focusing of the image can be carried out at specific points of the image by processing the light collected by the lenslet array.

Lambert, James L.↗