Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

First experimental report of nonlinear collimator in the SuperKEKB

SuperKEKB collimator system protects the superconducting final focusing magnets (QC1 and QC2) from quenching caused by beam halo particles. For effective shielding, the minimum aperture of vertical collimators is set smaller than the physical aperture of QC1. However, such collimators become dominant sources of beam coupling impedance, which can limit the maximum beam current due to impedance-driven instabilities. To address this issue, a nonlinear collimator (NLC) was introduced in February 2024. NLC is designed to reduce both beam backgrounds and collimator impedance, thereby suppressing beam instabilities caused by short-range wakefields. In this paper, we describe the results on impedance effects, beam background reduction, and beam lifetime when the nonlinear collimation system is turned on and off. These results validate the NLC concept and offer a promising approach for future high-luminosity colliders.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient dielectric metasurface collimating lenses for mid-infrared quantum cascade lasers

Light emitted from single-mode semiconductor lasers generally has large divergence angles, and high numerical aperture lenses are required for beam collimation. Visible and near infrared lasers are collimated using aspheric glass or plastic lenses, yet collimation of mid-infrared quantum cascade lasers typically requires more costly aspheric lenses made of germanium, chalcogenide compounds, or other infrared-transparent materials. We report mid-infrared dielectric metasurface flat lenses that efficiently collimate the output beam of single-mode quantum cascade lasers. The metasurface lenses are composed of amorphous silicon posts on a flat sapphire substrate and can be fabricated at low cost using a single step conventional UV binary lithography. Mid-infrared radiation from a 4.8 μm distributed-feedback quantum cascade laser is collimated using a polarization insensitive metasurface lens with 0.86 numerical aperture and 79% transmission efficiency. The collimated beam has a half divergence angle of 0.36° and beam quality factor of M² =1.02.

47 OTHER INSTRUMENTATION↗

BEAM COLLIMATION IN THE PIP-II LINAC TO BOOSTER TRANSFER LINE

The new PIP-II superconducting linac will deliver a 2 mA average H⁻ beam to the existing Booster synchrotron. The injected beam is accumulated by charge exchange over approximately 300 turns; phase space painting is used to mitigate space charge effects. To limit the power load on the internal waste beam absorber from the transverse tails of the H⁻ distribution missing the foil, the beam will be collimated in both planes in the linac to Booster transfer line using compact collimators of a novel design. Both the number of parasitic hits and the fraction of the beam missing the foil are sensitive functions of the H⁻ beam centroid position with respect to the edge of the foil. The positioning of the collimation is constrained by the availability of suitable space in the transfer line lattice, by specifics of the collimator design, by the phase space orientation at the collimator, and by the betatron phase advance to the foil needed to achieve proper orientation of the spatial distribution at the injection point. In this contribution, we describe the procedure by which collimator positions were optimized. We then discuss the expected performance of the overall system.

Johnson, David E.↗

Optimizing collimator positions using bayesian optimization in the Fermilab MI-8 transfer line

Collimators are used to minimize losses and to remove particles that would otherwise get lost downstream and irradiate the machine. Finding the optimal jaw positions is time consuming and with the upstream beam properties changing, the collimation settings would need to be readjusted each time. Therefore, a method to optimize collimator positions and to operate them at full capacity in a short time is required for loss control downstream. A study of collimator positions was conducted and a machine learning (ML) model was developed to predict optimal collimator positions. Bayesian Optimization (BO) was used to calculate new jaw positions from the ML model. The results of BO and usage of ML for better performance of the collimation system are presented in this paper.

Babacan, Betiay [Fermilab]↗

Measurements of transverse beam halo diffusion rates in the LHC with collimator scans

Measurements of beam halo dynamics were conducted in the LHC on 22 June 2012 at 4 TeV using collimator scans. Four scans were performed: on proton beam 1 with a vertical collimator and on beam 2 with a horizontal collimator, first with squeezed separated beams and subsequently in collision. The time evolution of losses following collimator steps provides experimental estimates of halo diffusion, halo population, impact parameter distributions, and beam jitter. Besides its general interest for beam dynamics and machine performance characterization, this information forms an essential input for the general design of collimation systems, including new methods such as crystal collimators and hollow electron lenses. In this note, the results of an analysis of the data is presented.

43 PARTICLE ACCELERATORS↗

Design and fabrication of multigrid X-ray collimators

The paper considers the design and fabrication of multigrid collimators for use in X-ray astronomy. The most important collimator performance criteria are minimum off-band transmission or leakage, and maximum on-band transmission. Lockheed experience with multigrid collimator is summarized: (1) an Oda type with one-dimensional collimation of 1.7 arc minute FWHM and using only the central transmission band, (2) an Oda type with 2 arc minute one-dimensional collimation using up to 27 transmission bands, each separated by 42 arc min. and (3) a modified Parkinson type with two-dimensional collimation of 40 arc sec. Attention is given to grid materials, precision, plating, hole quality, and results of acceptance testing.

Acton, L. W.↗

Radiation beam collimation system and method

The invention provides a method for collimating a radiation beam, the method comprising subjecting the beam to a collimator that yaws and pitches, either separately or simultaneously relative to the incident angle of the beam. Also provided is a system for collimating radiation beams, the system comprising a collimator body, and a stage for pitching and yawing the body. A feature of the invention is that a single, compact mask body defines one or a plurality of collimators having no moving surfaces relative to each other, whereby the entire mask body is moved about a point in space to provide various collimator opening dimensions to oncoming radiation beams.

43 PARTICLE ACCELERATORS↗

New Methods of Particle Collimation in Colliders

The collimation system is an essential part of the design of any high-power accelerator. Its functions include protection of components from accidental and intentional energy deposition, reduction of backgrounds, and beam diagnostics. Conventional multi-stage systems based on scatterers and absorbers offer robust shielding and efficient collection of losses. Two complementary concepts have been proposed to address some of the limitations of conventional systems: channeling and volume reflection in bent crystals and collimation with hollow electron beams. The main focus of this paper is the hollow electron beam collimator, a novel concept based on the interaction of the circulating beam with a 5-keV, magnetically confined, pulsed hollow electron beam in a 2-m-long section of the ring. The electrons enclose the circulating beam, kicking halo particles transversely and leaving the beam core unperturbed. By acting as tunable diffusion enhancer and not as a hard aperture limitation, the hollow electron beam collimator extends conventional collimation systems beyond the intensity limits imposed by tolerable losses. The concept was tested experimentally at the Fermilab Tevatron proton-antiproton collider. Results on the collimation of 980-GeV antiprotons are presented, together with prospects for the future.

43 PARTICLE ACCELERATORS↗

A Novel Two Stage Collimation Unit for Fermilab Booster

A new two-stage collimation unit (2SC) for Fermilab Booster will be installed during 2024 summer shutdown. It is a supplementary collimator for existing single stage Booster collimators. Design details of this 2SC adapted to Booster conditions are described. Results of beam dynamics simulations on collimation efficiency and evaluation of collimator shielding with MARS code on this new system are presented. The analysis on beam dynamics shows that the system will help to collimate up to about 1% of the beam in a confined way and, prompt and residual activation meet Fermilab Radiological Control limits in current as well as during PIP-II era high intensity operation of the Booster.

43 PARTICLE ACCELERATORS↗

Choreographing Couch and Collimator in Volumetric Modulated Arc Therapy

Purpose: To design and optimize trajectory-based, noncoplanar subarcs for volumetric modulated arc therapy (VMAT) deliverable on both Varian TrueBEAM system and traditional accelerators; and to investigate their potential advantages for treating central nervous system (CNS) tumors. Methods and Materials: To guide the computerized selection of beam trajectories consisting of simultaneous couch, gantry, and collimator motion, a score function was implemented to estimate the geometric overlap between targets and organs at risk for each couch/gantry angle combination. An initial set of beam orientations is obtained as a function of couch and gantry angle, according to a minimum search of the score function excluding zones of collision. This set is grouped into multiple continuous and extended subarcs subject to mechanical limitations using a hierarchical clustering algorithm. After determination of couch/gantry trajectories, a principal component analysis finds the collimator angle at each beam orientation that minimizes residual target-organ at risk overlaps. An in-house VMAT optimization algorithm determines the optimal multileaf collimator position and monitor units for control points within each subarc. A retrospective study of 10 CNS patients compares the proposed method of VMAT trajectory with dynamic gantry, leaves, couch, and collimator motion (Tra-VMAT); a standard noncoplanar VMAT with no couch/collimator motion within subarcs (Std-VMAT); and noncoplanar intensity-modulated radiotherapy (IMRT) plans that were clinically used. Results: Tra-VMAT provided improved target dose conformality and lowered maximum dose to brainstem, optic nerves, and chiasm by 7.7%, 1.1%, 2.3%, and 1.7%, respectively, compared with Std-VMAT. Tra-VMAT provided higher planning target volume minimum dose and reduced maximum dose to chiasm, optic nerves, and cochlea by 6.2%, 1.3%, 6.3%, and 8.4%, respectively, and reduced cochlea mean dose by 8.7%, compared with IMRT. Tra-VMAT averaged beam-on time was comparable to Std-VMAT but significantly (45%) less than IMRT. Conclusion: Optimized couch, gantry, and collimator trajectories may be integrated into VMAT with improved mechanical flexibility and may provide better dosimetric properties and improved efficiency in the treatment of CNS tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Collimation study for LCLS

In this study we investigate the power deposition along the undulator section of the SLAC Linac Coherent Light Source (LCLS) due to the primary e¯ -beam but also due to potential secondary particles. The expected beam distribution after the LCLS injector is deliberately broadened as an approximated representation of the beam halo. Secondary particles, as e + , e¯ and photons, are generated as a result of tracking the intercepted beam through a dense material. This process is carried out by means of GEANT-4, which has been convoluted into our main tracking engine, LUCRETIA. Simulations show no losses along the undulator section when assuming the nominal primary beam and collimator gaps. However when opening the gaps of collimators located at the first collimator section, by 25%, the fattened beam is partially intercepted by the second collimator section, which is aligned to the undulators. Secondary particles, mostly photons generated at the second collimator section, deposit their energy along the undulator section, at a rate of the order of a milliwatt.

43 PARTICLE ACCELERATORS↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a radial collimator for the SEQUOIA direct geometry chopper spectrometer

The SEQUOIA direct geometry chopper spectrometer at the Spallation Neutron Source is considering acquisition of a radial collimator. We present here Monte-Carlo calculations examining the proposed collimator's performance. Through comparison of calculations with and without sample environments in place, one can determine appropriate parameters to use in the collimator design. The numerical results provide enough detail to determine the angular collimation for the radial collimator.

47 OTHER INSTRUMENTATION↗

A radial collimator for a time-of-flight neutron spectrometer

We have engineered and installed a radial collimator for use in the scattered beam of a neutron time-of-flight spectrometer at a spallation neutron source. The radial collimator may be used with both thermal and epithermal neutrons, reducing the detected scattering intensity due to material outside of the sample region substantially. The collimator is located inside of the sample chamber of the instrument, which routinely cycles between atmospheric conditions and cryogenic vacuum. The oscillation and support mechanism of the collimator allow it to be removed from use without breaking vacuum. We describe here the design and characterization of this radial collimator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel compact three-dimensional laser-sintered collimator for neutron scattering

Improvements in the available flux at neutron sources are making it increasingly feasible to obtain refineable neutron diffraction data from samples smaller than 1 mm{sup 3}. The signal is typically too weak to introduce any further sample environment in the 30–50 mm diameter surrounding the sample (such as the walls of a pressure cell) due to the high ratio of background to sample signal, such that even longer count times fail to reveal reflections from the sample. Many neutron instruments incorporate collimators to reduce parasitic scattering from the instrument and from any surrounding material and larger pieces of sample environment, such as cryostats. However, conventional collimation is limited in the volume it can focus on due to difficulties in producing tightly spaced neutron-absorbing foils close to the sample and in integrating this into neutron instruments. Here we present the design of a novel compact 3D rapid-prototyped (or “printed”) collimator which reduces these limitations and is shown to improve the ratio of signal to background, opening up the feasibility of using additional sample environment for neutron diffraction from small sample volumes. The compactness and ease of customisation of the design allows this concept to be integrated with existing sample environment and with designs that can be tailored to individual detector geometries without the need to alter the setup of the instrument. Results from online testing of a prototype collimator are presented. The proof of concept shows that there are many additional collimator designs which may be manufactured relatively inexpensively, with a broad range of customisation, and geometries otherwise impossible to manufacture by conventional techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grazing function g and collimation angular acceptance

The grazing function g is introduced - a synchrobetatron optical quantity that is analogous (and closely connected) to the Twiss and dispersion functions {beta}, {alpha}, {eta}, and {eta}'. It parametrizes the rate of change of total angle with respect to synchrotron amplitude for grazing particles, which just touch the surface of an aperture when their synchrotron and betatron oscillations are simultaneously (in time) at their extreme displacements. The grazing function can be important at collimators with limited acceptance angles. For example, it is important in both modes of crystal collimation operation - in channeling and in volume reflection. The grazing function is independent of the collimator type - crystal or amorphous - but can depend strongly on its azimuthal location. The rigorous synchrobetatron condition g = 0 is solved, by invoking the close connection between the grazing function and the slope of the normalized dispersion. Propagation of the grazing function is described, through drifts, dipoles, and quadrupoles. Analytic expressions are developed for g in perfectly matched periodic FODO cells, and in the presence of {beta} or {eta} error waves. These analytic approximations are shown to be, in general, in good agreement with realistic numerical examples. The grazing function is shown to scale linearly with FODO cell bend angle, but to be independent of FODO cell length. The ideal value is g = 0 at the collimator, but finite nonzero values are acceptable. Practically achievable grazing functions are described and evaluated, for both amorphous and crystal primary collimators, at RHIC, the SPS (UA9), the Tevatron (T-980), and the LHC.

43 PARTICLE ACCELERATORS↗

Collimator angle influence on dose distribution optimization for vertebral metastases using volumetric modulated arc therapy

Purpose: The cylindrical symmetry of vertebrae favors the use of volumetric modulated arc therapy in generating a dose ''hole'' on the center of the vertebrae limiting the dose to the spinal cord. The authors have evaluated if collimator angle is a significant parameter for dose distribution optimization in vertebral metastases. Methods: Three patients with one-three vertebrae involved were considered. Twenty-one differently optimized plans (nine single-arc and 12 double-arc plans) were performed, testing various collimator angle positions. Clinical target volume was defined as the whole vertebrae, excluding the spinal cord canal. The planning target volume (PTV) was defined as CTV+5 mm. Dose prescription was 5x4 Gy{sup 2} with normalization to PTV mean dose. The dose at 1 cm{sup 3} of spinal cord was limited to 11.5Gy. Results: The best plans in terms of target coverage and spinal cord sparing were achieved by two arcs and Arc1-80 deg. and Arc2-280 deg. collimator angles for all the cases considered (i.e., leaf travel parallel to the spinal cord primary orientation). If one arc is used, only 80 deg. reached the objectives. Conclusions: This study demonstrated the role of collimation rotation for the vertebrae metastasis irradiation, with the leaf travel parallel to the spinal cord primary orientation to be better than other solutions. Thus, optimal choice of collimator angle increases the optimization freedom to shape a desired dose distribution.

60 APPLIED LIFE SCIENCES↗