Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multimodel Assessment of the Factors Driving Stratospheric Ozone Evolution over the 21st Century

The evolution of stratospheric ozone from 1960 to 2100 is examined in simulations from 14 chemistry-climate models, driven by prescribed levels of halogens and greenhouse gases. There is general agreement among the models that total column ozone reached a minimum around year 2000 at all latitudes, projected to be followed by an increase over the first half of the 21st century. In the second half of the 21st century, ozone is projected to continue increasing, level off, or even decrease depending on the latitude. Separation into partial columns above and below 20 hPa reveals that these latitudinal differences are almost completely caused by differences in the model projections of ozone in the lower stratosphere. At all latitudes, upper stratospheric ozone increases throughout the 21st century and is projected to return to 1960 levels well before the end of the century, although there is a spread among models in the dates that ozone returns to specific historical values. We find decreasing halogens and declining upper atmospheric temperatures, driven by increasing greenhouse gases, contribute almost equally to increases in upper stratospheric ozone. In the tropical lower stratosphere, an increase in upwelling causes a steady decrease in ozone through the 21st century, and total column ozone does not return to 1960 levels in most of the models. In contrast, lower stratospheric and total column ozone in middle and high latitudes increases during the 21st century, returning to 1960 levels well before the end of the century in most models.

Oman, L. D.↗

OMI Measurements of Bromine Monoxide and Implications for Missing Sources of Polar Bromine in GEOS-Chem

The OMI satellite instrument provides total column measurements of bromine monoxide (BrO) with daily global coverage. Reactive bromine compounds (Br and BrO) catalytically destroy ozone in both the stratosphere and troposphere. The current emission scheme of brominated source gases in the GEOS-Chem chemical transport model well represents the stratospheric burden of bromine. However, halogen research in GEOS-Chem has largely focused on the influence of halogens on the tropospheric oxidative capacity. In the troposphere, the distribution of brominated compounds is more variable and significant uncertainties remain in the chemical processes governing the sources and sinks of reactive bromine compounds. In this study, we use GEOS-Chem simulated stratospheric columns of BrO to separate the tropospheric signal of BrO from the OMI total column measurements. The resulting tropospheric BrO columns are used to identify seasonal and regional anomalies in tropospheric BrO not currently represented in GEOS-Chem. In particular, periods of elevated tropospheric BrO during polar spring are observable by OMI, and past studies have connected these so-called "bromine explosion" events to near complete removal of surface ozone. Due to significant uncertainties in the springtime polar source of reactive bromine, many global models, including GEOS-Chem, do not simulate these tropospheric ozone depletion events. Consequently, OMI-based tropospheric columns of BrO are useful tool for investigating the impact of bromine explosion events on tropospheric ozone depletion episodes as well as background air quality.

Wales, Pamela↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

Improved Single-Cell Proteome Coverage Using Narrow-Bore Packed NanoLC Columns and Ultrasensitive Mass Spectrometry

Single-cell proteomics can provide unique insights into biological processes by resolving heterogeneity that is obscured by bulk measurements. Gains in the overall sensitivity and proteome coverage through improvements in sample processing and analysis increase the information content obtained from each cell, particularly for less abundant proteins. Here we report on improved single-cell proteome coverage through the combination of the previously developed Nanodroplet Processing in One Pot for Trace Samples (nanoPOTS) platform with further miniaturization of liquid chromatography (LC) separations and implementation of an ultrasensitive latest-generation mass spectrometry (MS) instrument. Following nanoPOTS sample preparation, protein digest from single cells were separated using a 20-µm-i.d. in-house-packed nanoLC column. Separated peptides were ionized using an etched fused silica emitter capable of stable ionization at the ~20 nL/min flow rate provided by the LC separation. Ultrasensitive LC-MS analysis was achieved using the Orbitrap Eclipse Tribrid mass spectrometer. An average of 362 protein groups were identified by MS/MS from single HeLa cells, and 874 protein groups were identified using the Match Between Runs (MBR) feature of MaxQuant. This represents a >70% increase in label-free proteome coverage for single cells relative to previous efforts using larger-bore (30-µm-i.d.) LC columns coupled to a previous-generation MS (Orbitrap Fusion Lumos).

Cong, Yongzheng↗

Linear stability analysis of two fluid columns of different densities and viscosities in a gravity field

The linear stability of a vertical interface separating two miscible fluid columns of different densities and viscosities under the influence of gravity is investigated. This flow possesses a time-dependent reference state (each column accelerates at different rates owing to their different densities) and the interface thickness grows as the square root of time (by diffusion). Numerical integration of the linear initial-value problem is carried out and discussed in detail as a function of vertical and spanwise wavenumbers and the flow parameters. Adjoint-based optimization is performed in order to determine initial conditions that lead to maximum growth of disturbances in finite time. Results indicate that the rate of growth of the perturbation energy at small wavenumbers (less affected by viscosity initially) is dominated by two-dimensional modes (no spanwise variation). Substantial transient growth is observed at higher wave modes initially, followed by asymptotic decay of the perturbations at large time. Sensitivity of perturbation growth with respect to initial time, density and viscosity ratios is investigated. This work is complementary to previous inviscid analysis of this configuration, which showed that the interface was unconditionally unstable at all wave modes, even in the presence of surface tension, and that instability grew as the exponential of time squared.

Mechanics↗

Coulometer battery state-of-charge indicator

Mercury-column electrochemical coulometer is a linear ampere-hour integrating device consisting of a sealed glass tube containing two columns of mercury separated by a gap containing an electrolyte. The drive circuit uses operational amplifier techniques to match nonlinear charge-discharge characteristics of an alkaline battery.

Birchenough, A. G.↗

Modified polymers for gas chromatography

Polymeric materials are modified to serve as stationary phase in chromatographic columns used for separation of atmospheric gases. Materials simplify and improve separation of atmospheric gases in terms of time, quantity of material needed, and sharpness of separation.

Woeller, F. H.↗

Hybrid polymer microspheres

Techniques have been successfully tested for bonding polymeric spheres, typically 0.1 micron in diameter, to spheres with diameter up to 100 microns. Hybrids are being developed as improved packing material for ion-exchange columns, filters, and separators.

Rembaum, A.↗

Analysis of volatile metabolites in biological fluids as indicators of prodromal disease condition

The volatile profile cannot be defined as a single class of substances, rather it is a broad spectrum of materials of different polarities characterized by having a boiling-point in the low to medium range (up to approximately 300 C) and the fact that the compounds are suitable for gas chromatography without derivatization. The organic volatile profiles are very complex mixtures of metabolic byproducts, intermediates, and terminal products of enzymatic degradations composed mainly of alcohols, ketones, aldehydes, pyrazines, sulfides, isothiocyanates, pyrroles, and furans. The concentration of organic volatiles in biological fluids covers a wide range with many important components present at trace levels. The complexity of the organic volatile fraction requires the use of capillary columns for their separation.

Zlatkis, A.↗

Measuring Trace Hydrocarbons in Silanes

Technique rapid and uses standard analytical equipment. Silane gas containing traces of hydrocarbons injected into carrier gas of moist nitrogen having about 0.2 percent water vapor. Carrier, water and silane pass through short column packed with powdered sodium hydroxide which combines moisture and silane to form nonvolatile sodium silicate. Carrier gas free of silane but containing nonreactive hydrocarbons, pass to silica-gel column where chromatographic separation takes place. Hydrocarbons measured by FID.

Lesser, L. A.↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Columnar growth of CoSi2 on Si(111), Si(100) and Si(110) by molecular beam epitaxy

Codeposition of silicon and cobalt on heated silicon substrates in ratios several times the silicide stoichiometry is found to result in epitaxial columns of CoSi2 surrounded by a matrix of epitaxial silicon. For (111)-oriented wafers, nearly cylindrical columns are formed, where both columns and surrounding silicon are defect free, as deduced from transmission electron microscopy. Independent control of the column diameter and separation is possible, and diameters of 27-135 nm have been demonstrated.

Fathauer, R. W.↗

OASIS: Organics Analyzer for Sampling Icy Surfaces

Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.

Getty, S. A.↗

Multi-Pass Quadrupole Mass Analyzer

Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments.

Prestage, John D.↗

Transient plasma-detachment events induced by multiple gas puffs in ADITYA-U tokamak

Application of periodic short bursts of gas leads to periodic separation of the plasma column edge from the limiter in the Ohmically heated discharges of ADITYA-U tokamak. After every gas-puff, injecting around 10 17 –10 18 m −3 molecules of fuel gas in the edge of the plasma column, a significant reduction in plasma density, temperature, H α emission intensity and an increase in the H β /H α ratio is observed in the vicinity of the limiter radius for a certain time duration before these parameters regain their pre-gas puff values. A decline in the ion-flux to the limiter is also observed simultaneously. The global confinement of plasma also increases after each gas-puff. These observations, which repeat after each gas-injection, imply that the plasma–neutral interaction occurs further away from the limiters after the gas-injection and indicate a periodic plasma separation from the limiter surface. Further investigation revealed that the gas-injection modifies the radial and toroidal electric field, which may be playing a role in the separation of the plasma column from the limiter surface. It was further demonstrated by an electrode bias experiment in the absence of gas-injection that an application of an external radial electric field can result in obtaining a separated plasma state.

Physics - Plasma physics↗

Mineral Separation in a CELSS by Ion-exchange Chromatography

Operational parameters pertinent to ion exchange chromatography separation were identified. The experiments were performed with 9 mm diameter ion exchange columns and conventional column accessories. The cation separation beds were packed with AG 50W-X2 strong acid cation exchange resin in H(+) form and 200-400 dry mesh particle size. The stripper beds used in some experiments were packed with AG 1-XB strong base cation exchange resin in OH(-) form and 200-400 dry mesh particle size.

Ballou, E. V.↗

Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

White, Richard M.↗