Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography Imaging Spectrometer (CTIS) with 2D Reflective Grating for Ultraviolet to Long-Wave Infrared Detection Especially Useful for Surveying Transient Events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for events it is also for investigation of some slow moving phenomena as in the life sciences.

Daniel W Wilson↗

Computed tomography imaging spectrometer (CTIS) with 2D reflective grating for ultraviolet to long-wave infrared detection especially useful for surveying transient events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for rapidly occurring events it is also useful for investigation of some slow moving phenomena as in the life sciences.

Wilson, Daniel W.↗

Hyperdimensional computing for image classification (HDC) v1.0

This is an implementation of the hyperdimensional computing technique to classify images. It consists of a python script that trains the system for a set of images from a set of images (dataset) specified by the user. This training produces hardware configuration parameters and description vectors that are then loaded into the hardware description part of the project. The hardware description consists of hardware described in Verilog (a well known language for this purpose) that is synthesizable and can be implemented in a real chip. This hardware received the training information generated by python, and then is able to accept images to produce answers for each image on which category (class) from the pre-=trained ones the image belongs to. The hardware and python training scripts are configurable and documented. The advantage of hyperdimensional computing is its robustness to errors and the easy capability for online learning (refining the training during inference slowly over time), which this implementation supports.

Michelogiannakis, Georgios [Lawrence Berkeley Nati↗

Identifying local structural states in atomic imaging by computer vision

Abstract The availability of atomically resolved imaging modalities enables an unprecedented view into the local structural states of materials, which manifest themselves by deviations from the fundamental assumptions of periodicity and symmetry. Consequently, approaches that aim to extract these local structural states from atomic imaging data with minimal assumptions regarding the average crystallographic configuration of a material are indispensable to advances in structural and chemical investigations of materials. Here, we present an approach to identify and classify local structural states that is rooted in computer vision. This approach introduces a definition of a structural state that is composed of both local and nonlocal information extracted from atomically resolved images, and is wholly untethered from the familiar concepts of symmetry and periodicity. Instead, this approach relies on computer vision techniques such as feature detection, and concepts such as scale invariance. We present the fundamental aspects of local structural state extraction and classification by application to simulated scanning transmission electron microscopy images, and analyze the robustness of this approach in the presence of common instrumental factors such as noise, limited spatial resolution, and weak contrast. Finally, we apply this computer vision-based approach for the unsupervised detection and classification of local structural states in an experimental electron micrograph of a complex oxides interface, and a scanning tunneling micrograph of a defect-engineered multilayer graphene surface.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterizing Biomass Feedstock Transport Properties Using State of the Art Imaging and Computational Techniques

The microstructure of lignocellulosic biomass determines heat and mass transfer during conversion processes. We present a novel method for characterizing the transport properties of biomass using advanced imaging and computational techniques. The microstructure of two woody feedstocks, red oak and Douglas fir, before and after pyrolysis, is revealed using X-ray computed tomography (XCT). Transport properties are calculated from the XCT images, and principal permeability tensors are calculated using an immersed boundary-based finite volume solver to model gas flow through the geometries. We observe that the permeabilities of native biomass are distinctly anisotropic, however, this anisotropy is greatly reduced after pyrolysis.

adaptive mesh refinement↗

Correlation of Computed Tomography Imaging Features With Pain Response in Patients With Spine Metastases After Radiation Therapy

Purpose: To correlate computed tomography (CT) imaging features of spinal metastases with pain relief after radiotherapy (RT). Methods and Materials: Thirty-three patients receiving computed tomography (CT)-simulated RT for spinal metastases in an outpatient palliative RT clinic from January 2007 to October 2008 were retrospectively reviewed. Forty spinal metastases were evaluated. Pain response was rated using the International Bone Metastases Consensus Working Party endpoints. Three musculoskeletal radiologists and two orthopaedic surgeons evaluated CT features, including osseous and soft tissue tumor extent, presence of a pathologic fracture, severity of vertebral height loss, and presence of kyphosis. Results: The mean patient age was 69 years; 24 were men and 9 were women. The mean worst pain score was 7/10, and the mean total daily oral morphine equivalent was 77.3 mg. Treatment doses included 8 Gy in one fraction (22/33), 20 Gy in five fractions (10/33), and 20 Gy in eight fractions (1/33). The CT imaging appearance of spinal metastases included vertebral body involvement (40/40), pedicle involvement (23/40), and lamina involvement (18/40). Soft tissue component (10/40) and nerve root compression (9/40) were less common. Pathologic fractures existed in 11/40 lesions, with resultant vertebral body height loss in 10/40 and kyphosis in 2/40 lesions. At months 1, 2, and 3 after RT, 18%, 69%, and 70% of patients experienced pain relief. Pain response was observed with various CT imaging features. Conclusions: Pain response after RT did not differ in patients with and without pathologic fracture, kyphosis, or any other CT features related to extent of tumor involvement. All patients with painful spinal metastases may benefit from palliative RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Informing Patients About the Cancer Induction Risk of Undergoing Computed Tomography Imaging: The Radiographers' Perspective

In the midst of debates about the actual risk posed from computed tomography (CT) imaging, there is a general consensus that patients have a right to information. Despite this, communication of the potential cancer induction risk from CT scans is poor, leading to poor patient awareness. Without adequate awareness of any significant risks patients might be deprived of the opportunity to take part in their own care and, therefore, the opportunity for patient-centered care is missed. The aims of this study were to determine whether CT radiographers provide patients with information about cancer induction risks from CT scans and the rationale for their practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Instrument requirements for imaging the magnetosphere in extreme-ultraviolet and energetic neutral atoms derived from computer-simulated images

Scientific requirements for He(+)(304 A) and energetic neutral atom (ENA) magnetospheric imaging, as well as the derived instrumental requirements are presented. Both ENA imaging of the hot plasma and EUV imaging of the cold plasma are highlighted. The question of the accuracy with which physically significant parameters can be extracted from actual images using computerized algorithms is addressed. An example of an ENA image analyzed by means of the Powell minimization algorithm is given. Automated unfolding of global magnetospheric images is also discussed. A Mercator projection of a model INA image is shown.

Roelof, Edmond C.↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Land classification of south-central Iowa from computer enhanced images

The author has identified the following significant results. The Iowa Geological Survey developed its own capability for producing color products from digitally enhanced LANDSAT data. Research showed that efficient production of enhanced images required full utilization of both computer and photographic enhancement procedures. The 29 August 1972 photo-optically enhanced color composite was more easily interpreted for land classification purposes than standard color composites.

Lucas, J. R.↗

Image processing on the IBM personal computer

An experimental, personal computer image processing system has been developed which provides a variety of processing functions in an environment that connects programs by means of a 'menu' for both casual and experienced users. The system is implemented by a compiled BASIC program that is coupled to assembly language subroutines. Image processing functions encompass subimage extraction, image coloring, area classification, histogramming, contrast enhancement, filtering, and pixel extraction.

Myers, H. J.↗

Computer-assisted image analysis of plant growth, thigmomorphogenesis and gravitropism

A nonintrusive auxonometric system, based on the DARWIN image processor (Telewski et al. 1983 Plant Physiol 72: 177-181), is described and demonstrated in the analysis of gravitropism and thigmomorphogenesis in corn seedlings (Zea mays). Using this system, growth and bending of regularly shaped plants or organs can be quickly and accurately measured without, in any way, interfering with the plant. Furthermore, the growth and bending curves are automatically plotted. Thigmomorphogenesis in the aerial part of corn seedlings involves growth promotion at a low force load and growth retardation at higher force loads. The time courses of the two kinds of response are somewhat different, with retardation occurring immediately after mechanical perturbation and growth promotion taking somewhat longer to begin. Gravitropic experiments show that when dark-grown corn seedlings are placed on their side in the light, the resulting curvature is due to two consecutive morphological mechanisms. In the first instance, lasting for about 15 minutes, the elongation of the bottom edge of the plant accelerates, while the elongation of the top edge remains constant. After that, for the next 1.75 hours, the elongation of the top edge decelerates and stops while that of the bottom edge remains constant at the increased rate for most of the period. The measurements taken from both experiments at relatively high resolution (0.08-0.1 millimeter) show that the growth curves are not smooth but show many small irregularities which may or may not involve micronutations.

Zea mays/growth & development/physiology↗

Semiautomatic vessel wall detection and quantification of wall thickness in computed tomography images of human abdominal aortic aneurysms

Purpose: Quantitative measurements of wall thickness in human abdominal aortic aneurysms (AAAs) may lead to more accurate methods for the evaluation of their biomechanical environment. Methods: The authors describe an algorithm for estimating wall thickness in AAAs based on intensity histograms and neural networks involving segmentation of contrast enhanced abdominal computed tomography images. The algorithm was applied to ten ruptured and ten unruptured AAA image data sets. Two vascular surgeons manually segmented the lumen, inner wall, and outer wall of each data set and a reference standard was defined as the average of their segmentations. Reproducibility was determined by comparing the reference standard to lumen contours generated automatically by the algorithm and a commercially available software package. Repeatability was assessed by comparing the lumen, outer wall, and inner wall contours, as well as wall thickness, made by the two surgeons using the algorithm. Results: There was high correspondence between automatic and manual measurements for the lumen area (r=0.978 and r=0.996 for ruptured and unruptured aneurysms, respectively) and between vascular surgeons (r=0.987 and r=0.992 for ruptured and unruptured aneurysms, respectively). The authors' automatic algorithm showed better results when compared to the reference with an average lumen error of 3.69%, which is less than half the error between the commercially available application Simpleware and the reference (7.53%). Wall thickness measurements also showed good agreement between vascular surgeons with average coefficients of variation of 10.59% (ruptured aneurysms) and 13.02% (unruptured aneurysms). Ruptured aneurysms exhibit significantly thicker walls (1.78{+-}0.39 mm) than unruptured ones (1.48{+-}0.22 mm), p=0.044. Conclusions: While further refinement is needed to fully automate the outer wall segmentation algorithm, these preliminary results demonstrate the method's adequate reproducibility and low interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using computer-extracted image features for modeling of error-making patterns in detection of mammographic masses among radiology residents

Purpose: Mammography is the most widely accepted and utilized screening modality for early breast cancer detection. Providing high quality mammography education to radiology trainees is essential, since excellent interpretation skills are needed to ensure the highest benefit of screening mammography for patients. The authors have previously proposed a computer-aided education system based on trainee models. Those models relate human-assessed image characteristics to trainee error. In this study, the authors propose to build trainee models that utilize features automatically extracted from images using computer vision algorithms to predict likelihood of missing each mass by the trainee. This computer vision-based approach to trainee modeling will allow for automatically searching large databases of mammograms in order to identify challenging cases for each trainee. Methods: The authors’ algorithm for predicting the likelihood of missing a mass consists of three steps. First, a mammogram is segmented into air, pectoral muscle, fatty tissue, dense tissue, and mass using automated segmentation algorithms. Second, 43 features are extracted using computer vision algorithms for each abnormality identified by experts. Third, error-making models (classifiers) are applied to predict the likelihood of trainees missing the abnormality based on the extracted features. The models are developed individually for each trainee using his/her previous reading data. The authors evaluated the predictive performance of the proposed algorithm using data from a reader study in which 10 subjects (7 residents and 3 novices) and 3 experts read 100 mammographic cases. Receiver operating characteristic (ROC) methodology was applied for the evaluation. Results: The average area under the ROC curve (AUC) of the error-making models for the task of predicting which masses will be detected and which will be missed was 0.607 (95% CI,0.564-0.650). This value was statistically significantly different from 0.5 (p < 0.0001). For the 7 residents only, the AUC performance of the models was 0.590 (95% CI,0.537-0.642) and was also significantly higher than 0.5 (p = 0.0009). Therefore, generally the authors’ models were able to predict which masses were detected and which were missed better than chance. Conclusions: The authors proposed an algorithm that was able to predict which masses will be detected and which will be missed by each individual trainee. This confirms existence of error-making patterns in the detection of masses among radiology trainees. Furthermore, the proposed methodology will allow for the optimized selection of difficult cases for the trainees in an automatic and efficient manner.

60 APPLIED LIFE SCIENCES↗

Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images

Purpose and Objectives: To quantify, through an observer study, the reduction in metal artifacts on cone beam computed tomographic (CBCT) images using a projection-interpolation algorithm, on images containing metal artifacts from dental fillings and implants in patients treated for head and neck (H&N) cancer. Methods and Materials: An interpolation-substitution algorithm was applied to H&N CBCT images containing metal artifacts from dental fillings and implants. Image quality with respect to metal artifacts was evaluated subjectively and objectively. First, 6 independent radiation oncologists were asked to rank randomly sorted blinded images (before and after metal artifact reduction) using a 5-point rating scale (1 = severe artifacts; 5 = no artifacts). Second, the standard deviation of different regions of interest (ROI) within each image was calculated and compared with the mean rating scores. Results: The interpolation-substitution technique successfully reduced metal artifacts in 70% of the cases. From a total of 60 images from 15 H&N cancer patients undergoing image guided radiation therapy, the mean rating score on the uncorrected images was 2.3 ± 1.1, versus 3.3 ± 1.0 for the corrected images. The mean difference in ranking score between uncorrected and corrected images was 1.0 (95% confidence interval: 0.9-1.2, P<.05). The standard deviation of each ROI significantly decreased after artifact reduction (P<.01). Moreover, a negative correlation between the mean rating score for each image and the standard deviation of the oral cavity and bilateral cheeks was observed. Conclusion: The interpolation-substitution algorithm is efficient and effective for reducing metal artifacts caused by dental fillings and implants on CBCT images, as demonstrated by the statistically significant increase in observer image quality ranking and by the decrease in ROI standard deviation between uncorrected and corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Land Classification of South-Central Iowa from Computer Enhanced Images

The author has identified the following significant results. Two CCT (computer compatible tapes) scenes were digitally enhanced. The IMAGE 100 system was utilized for image processing. The real time ability of this machine allowed large scale viewing of several selected areas on both CCT's.

Taranik, J. V.↗