Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Computerized Operator Support System – Phase II Development

A computerized operator support system (COSS) prototype for nuclear control room process control is proposed and discussed. The COSS aids operators in addressing rapid plant upsets that would otherwise result in the shutdown of the power plant and interrupt electrical power generation, representing significant costs to the owning utility. In its current stage of development the prototype demonstrates four advanced functions operators can use to more efficiently monitor and control the plant. These advanced functions consist of: (1) a synthesized and intuitive high level overview display of system components and interrelations, (2) an enthalpy-based mathematical chemical and volume control system (CVCS) model to detect and diagnose component failures, (3) recommended strategies to mitigate component failure effects and return the plant back to pre-fault status, and (4) computer-based procedures to walk the operator through the recommended mitigation actions. The COSS was demonstrated to a group of operators and their feedback was collected. The operators responded positively to the COSS capabilities and features and indicated the system would be an effective operator aid. The operators also suggested several additional features and capabilities for the next iteration of development. Future versions of the COSS prototype will include additional plant systems, flexible computer-based procedure presentation formats, and support for simultaneous component fault diagnosis and dual fault synergistic mitigation action strategies to more efficiently arrest any plant upsets.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Variational multiscale element-free Galerkin method combined with the moving Kriging interpolation for solving some partial differential equations with discontinuous solutions

Solving partial differential equations with discontinuous solutions is an important challenging problem in numerical analysis. To this end, there are some methods such as finite volume method, discontinuous Galerkin approach and particle technique that are able to solve these problems. In the current paper, the moving Kriging element-free Galerkin method has been combined with the variational multiscale algorithm to obtain acceptable and high-resolution solutions. For testing this technique, we select some PDEs with discontinuous solution such as Burgers’, Sod’s shock tube, advection–reaction–diffusion, Kuramoto–Sivashinsky, Boussinesq and shallow water equations. First, we obtain a time-discrete scheme by approximating time derivative via finite difference technique. Then we introduce the moving Kriging interpolation and also obtain their shape functions. We use the element-free Galerkin method for approximating the spatial derivatives. This method uses a weak form of the considered equation that is similar to the finite element method with the difference that in the classical element-free Galerkin method test and trial functions are moving least squares approximation (MLS) shape functions. Since the shape functions of moving least squares (MLS) approximation do not have Kronecker delta property, we cannot implement the essential boundary condition, directly. Thus, we employ the shape functions of moving Kriging interpolation and radial point interpolation technique which have the mentioned property. Also, in the element-free Galekin method, we do not use any triangular, quadrangular or other type of meshes. The element-free Galerkin method is a global method while finite element method is a local one. This technique employs a background mesh for integration which makes it different from the truly mesh procedures. Several test problems are solved and numerical simulations are reported which confirm the efficiency of the proposed schemes.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-15: Automatically Detect Patient Treatment Position and Orientation in KV Portal Images

Purpose: In the course of radiation therapy, the complex information processing workflow will Result in potential errors, such as incorrect or inaccurate patient setups. With automatic image check and patient identification, such errors could be effectively reduced. For this purpose, we developed a simple and rapid image processing method, to automatically detect the patient position and orientation in 2D portal images, so to allow automatic check of positions and orientations for patient daily RT treatments. Methods: Based on the principle of portal image formation, a set of whole body DRR images were reconstructed from multiple whole body CT volume datasets, and fused together to be used as the matching template. To identify the patient setup position and orientation shown in a 2D portal image, the 2D portal image was preprocessed (contrast enhancement, down-sampling and couch table detection), then matched to the template image so to identify the laterality (left or right), position, orientation and treatment site. Results: Five day’s clinical qualified portal images were gathered randomly, then were processed by the automatic detection and matching method without any additional information. The detection results were visually checked by physicists. 182 images were correct detection in a total of 200kV portal images. The correct rate was 91%. Conclusion: The proposed method can detect patient setup and orientation quickly and automatically. It only requires the image intensity information in KV portal images. This method can be useful in the framework of Electronic Chart Check (ECCK) to reduce the potential errors in workflow of radiation therapy and so to improve patient safety. In addition, the auto-detection results, as the patient treatment site position and patient orientation, could be useful to guide the sequential image processing procedures, e.g. verification of patient daily setup accuracy. This work was partially supported by research grant from Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Influence of Porosity and Pore Distributions on Strength Properties of Porous Alumina

In this work, strength properties of porous alumina with three different porosities as well as dense one were investigated to clarify porosity effects on strength properties. It was revealed that the strength had a general tendency to decrease drastically as increasing porosity. Spatial and size distributions of pores were characterized by observing specimen surfaces through a laser scanning microscope. Based on the observed pore characteristics, a procedure to estimate porosity effects on strength was newly developed in the framework of fracture mechanics, where a stress intensity factor-based criterion was applied for fracture of porous ceramics. In the procedure, it is assumed that porous ceramics have the same characteristics of crack distribution as those of pore distribution, and pores are presumed to be surrounded by virtual cracks. Monte Carlo simulations by using the procedure were carried out to estimate strength for four respective materials. Simulated strength coincided with experimentally observed one within a scatter band of factor of 2{sup 1/2}. Consequently, the developed procedure was confirmed to be efficient in evaluating effects of bulk porosity and pore distributions on strength of porous alumina.

36 MATERIALS SCIENCE↗

Verification of the helioseismology travel-time measurement technique and the inversion procedure for sound speed using artificial data

We performed three-dimensional numerical simulations of the solar surface acoustic wave field for the quiet Sun and for three models with different localized sound-speed perturbations in the interior with deep, shallow, and two-layer structures. We used the simulated data generated by two solar acoustics codes that employ the same standard solar model as a background model, but utilize different integration techniques and different models of stochastic wave excitation. Acoustic travel times were measured using a time-distance helioseismology technique, and compared with predictions from ray theory frequently used for helioseismic travel-time inversions. It is found that the measured travel-time shifts agree well with the helioseismic theory for sound-speed perturbations, and for the measurement procedure with and without phase-speed filtering of the oscillation signals. This testing verifies the whole measuring-filtering-inversion procedure for static sound-speed anomalies with small amplitude inside the Sun outside regions of strong magnetic field. It is shown that the phase-speed filtering, frequently used to extract specific wave packets and improve the signal-to-noise ratio, does not introduce significant systematic errors. Results of the sound-speed inversion procedure show good agreement with the perturbation models in all cases. Due to its smoothing nature, the inversion procedure may overestimate sound-speed variations in regions with sharp gradients of the sound-speed profile.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Polycystic Liver Disease

A 77-year-old African American male presented with intermittent abdominal pain for one week. He denied nausea, vomiting, diarrhea, constipation, fevers, anorexia, or weight loss. He denied a family history of liver disease, recent travel, or history of intravenous drug abuse. His vital signs were normal. Labs revealed total bilirubin of 1.5 mg/dl, hypoalbuminaemia 3.0 gm/dl and prolonged prothrombin time of 14.8 sec. Computed Tomography of the abdomen and pelvis with contrast showed multiple hepatic cysts with the largest cyst occupying the right abdomen, measuring 20.6 cm (Panel A and). This cyst had predominantly fluid attenuation, but also contained several septations. The patient underwent laparoscopic fenestration of the large hepatic cyst with hepatic cyst wall biopsy. Pathology revealed blood without malignant cells. The patient tolerated the procedure well with improvement of his abdominal pain and normalization of his liver function tests and coagulation profile.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a steerable needle for CT-guided nerve plexus blockade

Purpose: Demonstrate the use of a new steerable needle for CT-guided neural plexus blockade to avoid traversing the kidneys. Materials and methods: Retrospective evaluation of 23 consecutive CT-guided neural plexus blockade procedures in which a new steerable needle was used in the last 13 and compared with the prior 10 procedures in which a standard needle was used. Results: Use of the steerable needle was beneficial to reach the target area without traversing a kidney or other organs in 6/13 (46%) procedures; in the other 7 procedures there was no benefit. A kidney was traversed in 0/13 procedures performed with the steerable needle. In contrast, a kidney was traversed in 4/10 (40%) procedures using a standard needle (P = 0.02). There was no significant difference in clinical benefit (P = 1.00) or complications (P = 0.56) between procedures using the steerable needle versus a standard needle. Three complications were observed (1 major and 2 minor) felt to be related to the injection and not the needle type. Conclusions: The utility of a steerable 21-gauge needle during neural plexus blockades was found to allow for avoidance of the kidneys when compared to a standard (non-steerable) needle. Interventional radiologists may find this needle and its future iterations useful for neural blockades, as well as other procedures, when intervening structures need to be avoided. Level of evidence: Level 3, Non-randomized controlled cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a general method for obtaining the geometry of microfluidic networks

In the present study, a general method for geometry of fluidic networks is developed with emphasis on pressure-driven flows in the microfluidic applications. The design method is based on general features of network's geometry such as cross-sectional area and length of channels. Also, the method is applicable to various cross-sectional shapes such as circular, rectangular, triangular, and trapezoidal cross sections. Using constructal theory, the flow resistance, energy loss and performance of the network are optimized. Also, by this method, practical design strategies for the fabrication of microfluidic networks can be improved. The design method enables rapid prediction of fluid flow in the complex network of channels and is very useful for improving proper miniaturization and integration of microfluidic networks. Minimization of flow resistance of the network of channels leads to universal constants for consecutive cross-sectional areas and lengths. For a Y-shaped network, the optimal ratios of consecutive cross-section areas (A{sub i+1}/A{sub i}) and lengths (L{sub i+1}/L{sub i}) are obtained as A{sub i+1}/A{sub i} = 2{sup −2/3} and L{sub i+1}/L{sub i} = 2{sup −1/3}, respectively. It is shown that energy loss in the network is proportional to the volume of network. It is also seen when the number of channels is increased both the hydraulic resistance and the volume occupied by the network are increased in a similar manner. Furthermore, the method offers that fabrication of multi-depth and multi-width microchannels should be considered as an integral part of designing procedures. Finally, numerical simulations for the fluid flow in the network have been performed and results show very good agreement with analytic results.

36 MATERIALS SCIENCE↗

SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalities include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.

60 APPLIED LIFE SCIENCES↗

Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Mapping from a DD Neutron Generator at the University of Sharjah

The University of Sharjah recently acquired a model DD109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. This neutron generator is intended to be used for various studies like neutron activation analysis, neutron imaging, and profiling and irradiation effects. It is imperative that appropriate measures are taken in order to minimize the radiation dose to the operators, students, and the public. The resulting dose must not exceed the limits set by the UAE Federal Authority for Nuclear Regulations (FANR) and the International Atomic Energy Agency (IAEA). The objective of this study is to generate a neutron and photon dose map of the generator room and its surrounding using simulations, experimentally verify this dose mapping, and set the operating and safety procedures for the neutron generator. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest-abdomen-pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore, serve as a jumping point from which to create an unlimited number of 3D and 4D variations for imaging research. Conclusions: A population of phantoms that includes a range of anatomical variations representative of the public at large is needed to more closely mimic a clinical study or trial. The series of anatomically variable phantoms developed in this work provide a valuable resource for investigating 3D and 4D imaging devices and the effects of anatomy and motion in imaging. Combined with Monte Carlo simulation programs, the phantoms also provide a valuable tool to investigate patient-specific dose and image quality, and optimization for adults undergoing imaging procedures.

60 APPLIED LIFE SCIENCES↗

The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Adrenal Venous Sampling by Non-experts with Reference to CT Images

PurposeTo establish technical success rates and safety of adrenal venous sampling (AVS) performed by non-experts with reference to CT images.Materials and Methods104 AVS procedures with adrenocorticotropic hormone stimulation were performed for patients with suspected primary aldosteronism. One of three radiology residents with 2nd, 5th, and 5th grade experience undertook the procedure under the guidance of an experienced, board-certified interventional radiologist with reference to contrast-enhanced CT images obtained in 102 cases. Successful catheterization of the adrenal veins was assessed using three criteria: an adrenal venous cortisol concentration of more than 200 μg/dL (criterion A); an adrenal vein/inferior vena cava cortisol ratio of more than 5:1 (criterion B); and an adrenal vein/inferior vena cava cortisol ratio of more than 10:1 (criterion C).ResultsThe operators were aware of the anatomy of the left adrenal veins in 102 cases (98 %) and of the right adrenal veins in 99 cases (95 %) prior to the procedure. CT identified the correct position of the right adrenal vein orifice in 82 of 99 cases (83 %). The overall technical success rates for AVS from the right adrenal vein according to criteria A, B, and C, were 96, 96, and 94 %, respectively. Those for the left adrenal vein were 97, 98, and 94 %, respectively. No significant differences in success rates were observed between the operators (p = 0.922–0.984). No major complications, including adrenal vein rupture, were observed.ConclusionsWhen CT images are used to guide AVS, the procedure can be performed successfully and safely even by non-experts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Fenestration for Branch Vessel Reconnection in Aortic Dissection Using a Novel Diamond-Tipped Chronic Total Occlusion Drilling Device: A Technical Report

Purpose: Aortic dissection is a complex condition with high morbidity and mortality. Endovascular treatments including percutaneous fenestration can be used to manage branch vessel ischaemia or risk of aortic rupture. A variety of techniques for aortic fenestration have been described. We describe the novel use of the TruePath Chronic Total Occlusion (CTO) device for aortic intimal fenestration to achieve side branch reconnection. Materials and Methods: We present three cases of aortic dissection presenting with symptoms of aortic side branch occlusion and end organ malperfusion, treated with aortic fenestration using the TruePath CTO device via trans-brachial and trans-femoral approaches. Results: Technical success was achieved in all three cases. No complications were encountered. Flow was restored in compromised visceral branches. Branches remained patent on follow-up CT angiography over a minimum 2.5-year follow-up period. Conclusion: Percutaneous aortic fenestration techniques enable a minimally invasive approach to treat visceral branch malperfusion associated with aortic dissection. The TruePath CTO device improves the control of the fenestration procedure with the potential to improve efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗