Search NASA⌕ Search

SEARCH · Search NASA

Results for “concentrated electrolyte solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Insights into the Assembly and Conformation of Nanoparticle Organic Hybrid Materials (NOHMs) in Solution with Varying Grafting Type

Recently, nanoparticle organic hybrid materials (NOHMs) have been considered promising electrolytes for energy storage applications due to their unique combination of properties, which include high thermal stability, negligible vapor pressure, and easy synthesis. However, the structural features of NOHMs in electrochemical systems are not well understood. Hence, we investigate the impact of grafting type (ionic vs covalent) on the structure and performance of NOHMs that consist of a silica core and grafted HPE polymer (Jeffamine M2070) in aqueous solution with and without the presence of the supporting electrolyte (0.1 M KHCO 3 ) using small-angle neutron scattering. Careful analyses of the results indicate that even at low grafting density (0.8 chains nm –2 ) and concentration (1–3 wt %), ionic NOHMs solutions contain a free polymer that may interact with the grafted polymer, altering the assembly of NOHMs in solution. Our investigation also elucidates that the covalent NOHM solutions consist of both aggregated and dispersed NOHMs in the solution. Moreover, the addition of the supporting electrolyte affects the assembly and structure of the polymer in the ionic NOHMs solution significantly, whereas only a slight change in the conformation of the grafted polymer is observed for covalent NOHMs. These conformational changes alter the performance of the NOHMs solution, resulting in a dramatic change in viscosity. Careful analysis shows that this significant alteration of solution viscosity in the ionic NOHMs can be traced back to the presence of the free polymer that interacts with the grafted layer and the attenuation of this interaction between the free and grafted polymers with the addition of salt. Furthermore, these studies elucidate the impact of grafting type on the overall structure, assembly, and performance of functionalized NOHMs in aqueous solution and explicitly correlate the structure and assembly of NOHMs to their transport properties and must be considered when designing functional systems that incorporate NOHMs.

25 ENERGY STORAGE↗

Optimal conditions for efficient flow-electrode capacitive deionization

One of the current barriers to achieving fast and stable performance for flow-electrode capacitive deionization (FCDI) is determining optimal operating parameters. To date, however, no consensus has been reached for universal conditions for FCDI. Through experimental and modeling approaches in this study, we systematically evaluated the influence of applied potential (V = 1.2–2.4 V) and electrolyte concentration (C0 = 0.05–0.5 M) on the FCDI and electrodialysis (ED) desalination processes. Evaluation indicators include the concentration decrease in the desalinated solution, salt removal rates, pH fluctuations, charge efficiency, and energy consumption. Results demonstrated that the dynamic curves of concentration decrease at 2.0 V nearly overlapped with the response at 1.6 V at certain electrolyte concentrations, while the salt removal rates at 0.2 M salt concentration were the best among all concentrations tested at a range of applied potential. Therefore, it was thus concluded that the optimum conditions for FCDI operation are 1.6 V applied potential and 0.2 M initial salt concentration, under which faradaic reactions are not being triggered, and concentration polarization does not significantly affect ion transfer. Furthermore, a comparative study between FCDI and ED indicated that ED has a different dependence on the electrolyte concentration and applied potential, in which the desalination can be linearly enhanced with increasing potential but greatly limited at high concentrations. Due to the presence of carbon particles in FCDI, the enhanced charge/ion transfer is probably the main reason for the different desalination performance of FCDI and ED. Overall, the optimal operating parameters obtained in this work could be used as basic test conditions for further development of new carbon-based materials for FCDI.

42 ENGINEERING↗

Reductive removal of pertechnetate and chromate by zero valent iron under variable ionic strength conditions

Radioactive technetium-99 (Tc) present in waste streams and subsurface plumes at legacy nuclear reprocessing sites worldwide poses potential risks to human health and the environment. This research comparatively evaluated efficiency of zero valent iron (ZVI) toward reductive removal of Tc(VII) in presence of Cr(VI) from NaCl and Na 2 SO 4 electrolyte solutions under aerobic conditions. In both electrolytes, anticorrosive Cr(VI) suppressed oxidation of ZVI at elevated concentrations resulting in the delay of initiation of Tc(VII) reduction to Tc(IV)). In the absence of Cr(VI), no such delay was observed in the analogous systems. At low ionic strength, retarded ZVI oxidation inhibited Tc(VII) reduction in part due to the competing thermodynamically more favorable reduction of Cr(VI) to Cr(III); this effect was particularly pronounced in the chloride medium at the ionic strength ? 0.1. Higher ionic strength favored reduction of both Tc(VII) and Cr(VI), which followed a second-order reaction rate in both electrolytes attributed to the more efficient iron oxidation as evident from x-ray diffraction and electron microscopy measurements. Magnetite was the primary iron oxide phase, and its higher fraction in the SO 4 2- solutions facilitated reductive removal of Tc(VII) and Cr(VI). In the Cl- matrix, Cr(VI) promoted further oxidation of magnetite as well as formation of chromite diminishing overall reductive capacity of this system and resulting in less effective removal of Tc(VII) compared to the SO 4 2- solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterize and control the multi-range structure of solution-phase systems with resonant x-ray scattering

This work aims at demonstrating the feasibility and impact of Anomalous X-ray Scattering (AXS) in characterizing the multi-range structures of solution-state systems. We will show preliminary investigation of long-range correlations in concentrated aqueous electrolytes with a combination of AXS and molecular dynamics (MD) simulations. We will also start exploring the capability of AXS to capture intra- and inter-molecular structure of dilute molecular systems, and specifically its sensitivity to the chemical environment surrounding active metal sites. We anticipate that the development of this method will help us to understand ion solvation and transport, which affect the performances of, for instance, electrocatalytic cells, as well as to identify/control the intrinsic structural factors that lead to selectivity, efficiency, and stability control during catalysis.

36 MATERIALS SCIENCE↗

Anionic Effects on Concentrated Aqueous Lithium Ion Dynamics

In this article, the structural dynamics, chemical reactivity, anisotropy, diffusivity, viscosity, and density were measured for concentrated lithium salt solutions, including lithium chloride (LiCl), lithium bromide (LiBr), lithium nitrite (LiNO 2 ), and lithium nitrate (LiNO 3 ), with methyl thiocyanate as an infrared vibrational probe molecule, using two-dimensional infrared spectroscopy (2D IR), nuclear magnetic resonance (NMR) spectroscopy, and viscometry. 2D IR, NMR, and viscosity results show that LiNO 2 exhibits longer correlation times, lower diffusivity, and nearly four times greater viscosity when compared to the other lithium salt solutions of the same concentration, suggesting that nitrite anions may strongly facilitate structure formation via strengthening water-ion interactions, directly impacting bulk solution properties at sufficiently high concentrations. Additionally, the LiNO 2 and LiNO 3 solutions show significantly reduced chemical reactivity with respect to lithium cations coordinating with the methyl thiocyanate when compared to the lithium halide salts.

2D IR↗

Hydration and transport properties of cesium hydroxide and mixed cesium hydroxide–sodium nitrite aqueous solutions

Here, this study explores the hydration and transport properties of aqueous cesium hydroxide (CsOH) solution, with or without 1 molar (M) sodium nitrite (NaNO 2 ). Historic studies of electrolyte solutions indicate that Cs + ions decrease viscosity and increase diffusion rates, whereas OH − ions have the opposite effect. Here, the influence of OH − was dominant in CsOH solutions, leading to increased viscosity and reduced diffusion rates. There was a linear relationship between diffusion coefficients and water activity, emphasizing the significant role of ion–water interactions in determining transport properties. This may be because the interaction between Cs + and the anions is weak even when they are in direct contact with each other. The weakness of the ion-pairing was established through thermodynamic analysis. The findings suggest that ion-pairing is not the only important interaction controlling transport properties when ion-pairing is weak. Nonetheless, ion-pairing or obstructions did result in more sluggish transport properties as electrolyte concentrations increased. Overall, the research enhances the understanding of the complexities underlying ion interactions in multicomponent solutions.

Reynolds, Jacob G. [Hanford Site (HNF), Richland, ↗

Equation for Electrolyte Viscosity

Equation agrees with measurements over wide concentration range. Plot of calculated values from equation and measured values show close match except at extremely low concentrations of electrolyte. Other equations do not match data as well and limited to dilute solutions.

Fedors, R. F.↗

Concentration‐dependent Cycling of Phenothiazine‐based Electrolytes in Nonaqueous Redox Flow Cells

Increasing redox-active species concentrations can improve viability for organic redox flow batteries by enabling higher energy densities, but the required concentrated solutions can become viscous and less conductive, leading to inefficient electrochemical cycling and low material utilization at higher current densities. To better understand these tradeoffs in a model system, we study a highly soluble and stable redox-active couple, N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT), and its bis(trifluoromethanesulfonyl)imide radical cation salt (MEEPT-TFSI). We measure the physicochemical properties of electrolytes containing 0.2–1 M active species and connect these to symmetric cell cycling behavior, achieving robust cycling performance. Specifically, for a 1 M electrolyte concentration, we demonstrate 94% materials utilization, 89% capacity retention, and 99.8% average coulombic efficiency over 435 h (100 full cycles). This demonstration helps to establish potential for high-performing, concentrated nonaqueous electrolytes and highlights possible failure modes in such systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Gaussian field approach to the solvation of spherical ions in electrolyte solutions

In this paper, the electrostatic response of an electrolyte solution to a spherical ion is studied with a Gaussian field theory. In order to capture the ionic correlation effect in concentrated solutions, the bulk dielectric response function is described by a two-Yukawa response function. The modified response function of the solution is solved analytically in the spherical geometry, from which the induced charge density and the electrostatic energy are also derived analytically. Comparisons with results for small ions in electrolyte solutions from the hyper-netted chain theory demonstrate the validity of the Gaussian field theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuum Description of the Role of Negative Transference Numbers on Ion Motion in Polymer Electrolytes

New experimental techniques such as electrophoretic NMR (eNMR) are emerging as powerful methods for directly measuring ion velocities in electrolytes under applied electric fields. The aim of this theoretical study is to predict the spatial- and temporal-dependence of these velocities of ions as a function of the magnitude of the applied field and salt concentration. It has recently been shown that mixtures of poly(ethylene oxide)-based (PEO) and lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) electrolytes exhibit negative cation transference numbers in a certain salt concentration range. In this range, the cation motion at early times is directed to the positive electrode at all locations in the cell; ion migration dominates in this regime. As time progresses, the cation velocity in finite zones near both the electrodes changes sign. These zones grow rapidly with time, reflecting the increasing importance of diffusion, and a point in time is reached beyond which the cation velocity in the entire cell is directed toward the negative electrode. Overall, our work reveals the limited time window over which the results of eNMR can be used to determine the transference number. More importantly, it shows how to account for the effect of diffusional flux in such experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beyond Local Solvation Structure: Nanometric Aggregates in Battery Electrolytes and their Effect on Electrolyte Properties

Electrolytes are an essential component of all electrochemical storage and conversion devices, such as batteries. In the history of battery development, the complex nature of electrolytes has often been a bottleneck. Fundamental knowledge of electrolyte systems encompasses elucidation of structure-property relationships of the solution species. Recently, nanometric aggregates have been observed in several classes of electrolytes, including super-concentrated, redox-flow, multivalent, polymer, and ionic liquid-based electrolytes. Compared with the well-studied local solvation structures such as contact ion pairs and solvent-separated ions, these aggregates impose unique effects on the ion distribution and transport both within bulk electrolytes and at electrode/electrolyte interfaces. This Perspective highlights the discovery of the aggregates in various battery electrolytes and their impact on electrolyte properties. We also present an outlook for future studies of this emerging field of nanometric aggregates and the need for the development of new experimental and computational tools to study their properties.

Yu, Zhou↗

Unique Conductivity Behavior in Water-In-Salt Electrolytes Driven by Ion Clusters

Understanding and predicting ion transport in aqueous electrolytes are crucial for advanced energy storage and biophysics, and many emergent technologies yet remain elusive. Herein, we introduce a unified framework to quantitatively describe and predict electrolyte conductivity that shifts from conventional molar concentration-based metrics to a volume fraction-based approach. Through analyzing a variety of electrolyte solutions via this perspective, we observe a universal conductivity peak at a 37% volume fraction. Small-angle X-ray scattering (SAXS) and molecular dynamics (MD) simulations reveal that nanometer-scale ion clusters drive this general behavior. Moreover, key geometric features of the ion transport pathwayssuch as pore size, tortuosity, and connectivityfollow a consistent dependence with respect to the volume fraction, reinforcing the argument for the universal conductivity trend. This paradigm shift opens new avenues for designing high-performance electrolytes and provides transformative insights for advancing studies in many fields, wherein molecular aggregates dictate transport properties.

Nguyen, Huong T. D.↗

All-vanadium sulfate acid redox flow battery system

All-vanadium sulfate redox flow battery systems have a catholyte and an anolyte comprising an aqueous supporting solution including chloride ions and phosphate ions. The aqueous supporting solution stabilizes and increases the solubility of vanadium species in the electrolyte, allowing an increased vanadium concentration over a desired operating temperature range. According to one example, the chloride ions are provided by MgCl2, and the phosphate ions are provided by (NH4)2HPO4.

25 ENERGY STORAGE↗

All-vanadium sulfate acid redox flow battery system

All-vanadium sulfate redox flow battery systems have a catholyte and an anolyte comprising an aqueous supporting solution including chloride ions and phosphate ions. The aqueous supporting solution stabilizes and increases the solubility of vanadium species in the electrolyte, allowing an increased vanadium concentration over a desired operating temperature range. According to one example, the chloride ions are provided by MgCl 2 , and the phosphate ions are provided by (NH 4 ) 2 HPO 4 .

Nie, Zimin↗

On the molecular correlations that result in field-dependent conductivities in electrolyte solutions

Employing recent advances in response theory and nonequilibrium ensemble reweighting, we study the dynamic and static correlations that give rise to an electric field-dependent ionic conductivity in electrolyte solutions. We consider solutions modeled with both implicit and explicit solvents, with different dielectric properties, and at multiple concentrations. Implicit solvent models at low concentrations and small dielectric constants exhibit strongly field-dependent conductivities. We compare these results to Onsager-Wilson theory of the Wien effect, which provides a qualitatively consistent prediction at low concentrations and high static dielectric constants but is inconsistent away from these regimes. The origin of the discrepancy is found to be increased ion correlations under these conditions. Explicit solvent effects act to suppress nonlinear responses, yielding a weakly field-dependent conductivity over the range of physically realizable field strengths. By decomposing the relevant time correlation functions, we find that the insensitivity of the conductivity to the field results from the persistent frictional forces on the ions from the solvent. Our findings illustrate the utility of nonequilibrium response theory in rationalizing nonlinear transport behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical modeling for redox flow battery design

Deeper market penetration of redox flow batteries requires optimization of the cell performance. Though important for optimization, detailed analytical solutions have not been developed for electrolyte flow, mass and charge transport, and reaction kinetics within redox flow batteries. To this end, here we present analytical solutions to active species concentration and over-potential based on advection-diffusion transport for ions and Bulter-Volmer model for interface reaction kinetics. The solutions were validated with results from a finite element model. These solutions were then applied to investigate the relationship between over-potential and state of charge, current density, reaction rate constant, flow velocity, diffusivity, total active species concentration, and electrode structure. Explicit formulas were identified for minimum activation over-potential and limiting current density as well as their dependence on electrolyte properties, operation conditions, and electrode structure. With our new mathematical formulas, this work provides a theoretical framework for flow battery design.

25 ENERGY STORAGE↗

Concentration-Dependent Solvation Structure and Dynamics of Aqueous Sulfuric Acid Using Multinuclear NMR and DFT

Sulfuric acid is a ubiquitous compound for industrial processes and aqueous sulfate solutions also play a critical role in electrolytes for many prominent battery chemistries. While the thermodynamic literature for it is quite well-developed, comprehensive studies of the solvation structure, and particularly molecular-scale dynamical and transport properties, are less available. This study applies a multinuclear NMR approach to the elucidation of the solvation structure and dynamics over a wide temperature (-10 – 50?C) and concentration (0 – 18 M) range, combining 17O shift, linewidth, and T1 relaxation measurements, 33S shift and linewidth measurements, and 1H PFG-NMR measurements of the proton self-diffusivity. In conjunction, these results indicate a crossover between two regimes of solvation structure and dynamics, occurring above the concentration associated with the deep eutectic point (~ 4.5 M), with the high-concentration regime dominated by strong water-sulfate correlation. This description was borne out in detail by the activation energy trends with increasing concentration derived from the relaxation of both the H2O/H3O+ and H2SO4/HSO4-/SO42- 17O resonances and the 1H self-diffusivity. However, the 17O chemical shift difference between the H2O/H3O+ and H2SO4/HSO4-/SO42- resonances across the entire temperature range is nevertheless strikingly linear. A computational approach coupling MD simulations and DFT NMR shift calculations to reproduce this trend is presented, which will be the subject of further development. This combination of multinuclear, dynamical NMR and computational methods, and the results furnished by this study, will provide a platform for future studies on battery electrolytes where aqueous sulfate chemistry plays a central role in the solution structure.

Bazak, Jonathan D.↗

Enhancing Resource Recovery through Electro-Assisted Regeneration of an Ammonia-Selective Cation Exchange Resin

Ammonia-selective adsorbents can manage reactive nitrogen in the environment and promote a circular nutrient economy. Weak acid cation exchangers loaded with zinc exhibit high ammonia selectivity but face two implementation barriers: the stability of the zinc–carboxylate bond in complex wastewaters and energy- and logistics-intensive adsorbent regeneration with acidic solutions. In this paper, we examined the stability of zinc–carboxylate bonds in varying solutions (pure ammonium solution, synthetic urine, and real urine) and during electro-assisted regeneration. For electrochemical regeneration, both electrolyte concentration and current density influenced the trade-off between ammonia regeneration and zinc elution. Using 10 mM K 2 SO 4 anolyte at a 0.08 mA/cm 2 current density, we achieved 4% zinc elution and 61% ammonia regeneration. In contrast, using 100 mM K 2 SO 4 at 4.96 mA/cm 2 improved the regeneration efficiency to 97% but eluted 60% of zinc. We found that electrolyte concentration was the key factor influencing the regeneration efficiency of the NH 3 -selective adsorbents. Due to prevalent zinc elution, we designed an in situ procedure for reforming the zinc–carboxylate bond and achieved similar adsorption densities between pre- and post-regenerated resins, thus enabling multiple cycle resin use. Ultimately, this study advances understanding of ammonia-selective resins that can facilitate high-purity, selective, and durable recovery of nutrients from waste streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗