Search NASA⌕ Search

SEARCH · Search NASA

Results for “conductive liquid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hydrodynamic electron transport in graphene Hall-bar devices

Here we consider hydrodynamic electron transport in the Hall-bar geometry. The theory is developed for systems with non-Galilean-invariant electron liquids. We show that inhomogeneity of the electron density induced by long-range disorder and gating leads to mixing between the hydrodynamic transport mode and transport relative to the electron liquid. For graphene systems near charge neutrality, these effects lead to strong coupling of the hydrodynamic flow to charge transport. As a result, the effective electrical conductivity of the system may significantly exceed the intrinsic conductivity of the electron liquid. We obtain analytic expressions for the thermoelectric transport coefficients of the system as a function of density in the full crossover region between clean and disorder-dominated regimes.

36 MATERIALS SCIENCE↗

Molecular understanding of ion transport in a zwitterionic electrolyte

Zwitterions (ZIs) are unique molecules that carry both positive and negative charges, resulting in overall charge neutrality and high dielectric constants. These distinctive properties have enabled broad applications of zwitterionic functionality, including the emerging use of ZIs in lithium-ion battery electrolytes. As a contribution to this developing field, we use all-atom molecular dynamics simulations to investigate the ion transport mechanisms in amorphous mixtures of a zwitterionic liquid containing a range of LiTFSI salt concentrations. Furthermore, the local coordination environment around the Li + ions plays a strong role in governing ionic conductivity, as well as the enhancement of Li + transport numbers with increasing salt concentration. Addition of small amounts of water leads to increased conductivity and ion mobilities due to the water coordinating with the Li + ions, which reduces direct interactions with larger charged species.

Classical molecular dynamic simulations↗

Iridium Surface Oxide Affects the Nafion Interface in Proton-Exchange-Membrane Water Electrolysis

Proton-exchange-membrane water electrolyzer (PEMWE) catalyst layers consist of aggregates of catalyst particles (typically iridium) and ionomer (typically Nafion). Prior work suggests that the oxide form of Ir affects the kinetics of the oxygen-evolution reaction. However, because most catalyst-benchmarking studies are conducted ex situ in liquid electrolytes, it remains unclear how the ionomer is influenced by the catalyst oxide and affects overall cell performance. Using a suite of experimental techniques, we conduct fundamental investigations into model ink (catalyst and ionomer dispersed in solution) and thin-film systems to inform cell-level overpotential analysis as a function of three forms of Ir (metallic Ir m , oxyhydroxide IrOOH, and oxide IrO 2 ). Furthermore, nafion on Ir m has a high degree of phase separation and higher swelling, likely improving the ionic conductivity. Additionally, Nafion binds most strongly to IrOOH, likely yielding reduced kinetic overpotentials. These findings highlight the intricacies of the ionomer/Ir interface and provide insight into all catalyst-layer systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of recirculating liquid fuel in a 1D critical stationary system

Several studies have been conducted to investigate the physics of liquid fuel reactors, showing also applications with molten salts. A liquid nuclear fuel implies changes in the neutron balance equation to take into account the precursors' displacement and the emission of delayed neutrons in a different position than at the original fission. This requires to upgrade the computer codes normally used to calculate nuclear reactors using only solid fuel. In this work, we revisit a simple problem with liquid fuel, which is proposed for the verification of the numerical solutions obtained by advanced computer codes. This problem studies criticality with constant coefficients, thus neglecting thermal feedback. We elaborate on the analytical solution of the problem, deriving also a generalized eigenvalue problem by finite-volume integration over the cells of a discretized mesh to study the evolution of the dominance ratio with fuel velocity. Finally, we investigate the influence of the fuel velocity on the reactivity of the system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Role of Solvent in the Oriented Growth of Conductive Ni‐CAT‐1 Metal‐Organic Framework at Solid–Liquid Interfaces

Abstract A controlled growth of two‐dimensional (2D) π‐conjugated metal‐organic frameworks (MOFs) on solid substrates can open exciting opportunities for the application of 2D MOFs as optoelectronic devices. Some factors like solvent composition and type of substrates are known to influence the properties of solution‐processed 2D MOF crystals; however, a mechanistic understanding of how interactions between solvent, substrate, and precursors affect heterogeneous nucleation has been limited. Here, it is reported that the structure of Ni‐catecholate (Ni‐CAT‐1) MOFs at a solid–liquid interface is controlled by solvent–substrate and solvent–MOF precursor interactions. Specifically, the structure of the MOF film can be controlled by varying the affinity of the solvent to the substrate. As a fraction of N , N ‐dimethylformamide (DMF) in a binary solvent mixture of water and DMF increases, the arrangement of Ni‐CAT‐1 crystals varies from vertically aligned nanorods to the graphite substrate to less ordered nanorods with the lower initial nucleation number density of Ni‐CAT‐1 crystals on the surface.

2D materials↗

Electrochemical, thermodynamic, and physical properties of tetradecyltrihexylphosphonium ([P 6,6, 6,14 ] + ) and methyl-propyl piperidinium containing ionic liquids and their propylene carbonate solutions

Here, the viscosity, conductivity, electrochemical window and related thermodynamic properties such as excess volume and dynamic viscosity deviation of two phosphonium ionic liquids were measured and calculated for “as-supplied” and dried neat liquids and also v/v mixtures of 99/1, 95/5, 90/10, 75/25, and 50/50 of the ionic liquids with propylene carbonate (PC). Tetradecyltrihexylphosphonium dicyanamide ([P 6,6,6,14 ] + dicyanamide), Cyphos 105, and tetradecyltrihexylphosphonium bis(trifluororomethanesulfonyl)imide (called bistriflimide) ([P 6,6,6,14 ] + bistriflimide), Cyphos 109, ionic liquids were studied. Generally speaking, there were slight differences in the measured properties of the wet and dried IL solutions which were reflected in differences if the calculated properties. The measured and calculated properties were compared with those collected and derived from a piperidinium-based ionic liquid, methyl-propyl piperidinium bistriflimide. Arrhenius plots for both the viscosity and conductivity were linear, with the linearity of the Litovitz plots being slightly higher. The viscosity and conductivity of the phosphonium solutions yielded Walden Plots that differed from Walden plots of piperidinium solutions and other ionic liquid solutions. For the phosphonium based ionic liquids, the ionicity was found to increase with increasing dilution in propylene carbonate. The electrochemical windows of the ionic liquids were determined as a function of the concentration of the ionic liquid present in the solution. The size of the window generally initially decreased and then increased with the addition of PC for the [P 6,6,6,14 ] + dicyanamide ionic liquid increasing from 3.4 V in the 95/5 v/v (volume Cyphos 105) to volume of PC solvent) to 3.7 in the 50/50 dried IL case. The electrochemical windows of the dried liquids were slightly larger 3.5 V for the 95/5 v/v and 4.2 V for the 50/50 v/v Cyphos 105/PC solutions. The electrochemical window was larger and the conductivity was higher for the piperidinium IL solutions, but since the ionicity increases with dilution, the phosphonium based IL solutions may prove favorable for processes such as electrochemical reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat↗

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat↗

Effects of oxygen on the adsorption/oxidation of aqueous Sb(III) by Fe-loaded biochar: An X-ray absorption spectroscopy study

Fe-loaded biochar (FeBC) has been considered for Sb(III) adsorption, but the effects of oxygen (O 2 ) on the adsorption need further investigation. Liquid-/solid-phase analyses were conducted to investigate the role of O 2 in the Sb(III) adsorption by FeBC. The adsorption was best described by the pseudo-second-order (PSO) model for kinetic results and by the Langmuir model for thermodynamic results. More than 96.8 % of Sb(III) was adsorbed by FeBC, and available O 2 increased the liquid-phase Sb(III) oxidation efficiency by 2.1–7.5 times. The peak changes at ~1640 and 3450 cm -1 in FTIR spectra indicated the occurrence of inner-sphere complexation between Sb(III)/Sb(V) and hydroxyl (–OH)/carboxyl (–COOH) groups in FeBC under aerobic and anaerobic conditions. Fe/Sb X-ray absorption spectroscopy (XAS) analysis results showed aqueous Sb(III) complexed to the edge-sharing Fe(III)-O-Fe(III) in FeBC. Regardless of whether O 2 was available or not, solid-phase edge-sharing Fe(III)-O-Sb(V) complexes (~3.05 Å), which had lower toxicity and migration ability than aqueous Sb(III), formed through a ligand-to-metal charge-transfer (LMCT) process. More than 91 % of adsorbed Sb(III) was oxidized to edge-sharing Fe(III)-O-Sb(V) complexes in 3 h. Additionally, the Sb(V) from liquid-phase oxidation could also directly complex to the Fe(III)-O-Fe(III) and form edge-sharing Fe(III)-O-Sb(V) complexes. Here these results provide evidence to inform further FeBC application for the Sb-contaminated water treatment.

54 ENVIRONMENTAL SCIENCES↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Machine learning predictions of diffusion in bulk and confined ionic liquids using simple descriptors

Ionic liquids have many intriguing properties and widespread applications such as separations and energy storage. However, ionic liquids are complex fluids and predicting their behavior is difficult, particularly in confined environments. We introduce fast and computationally efficient machine learning (ML) models that can predict diffusion coefficients and ionic conductivity of bulk and nanoconfined ionic liquids over a wide temperature range (350–500 K). The ML models are trained on molecular dynamics simulation data for 29 unique ionic liquids as bulk fluids and confined in graphite slit pores. This model is based on simple physical descriptors of the cations and anions such as molecular weight and surface area. Here, we also demonstrate that accurate results can be obtained using only descriptors derived from SMILES (simplified molecular-input line-entry system) codes for the ions with minimal computational effort. This offers a fast and efficient method for estimating diffusion and conductivity of nanoconfined ionic liquids at various temperatures without the need for expensive molecular dynamics simulations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Search for a Grotthuss mechanism through the observation of proton transfer

The transport of protons is critical in a variety of bio- and electro-chemical processes and technologies. The Grotthuss mechanism is considered to be the most efficient proton transport mechanism, generally implying a transfer of protons between ‘chains’ of host molecules via elementary reactions within the hydrogen bonds. Although Grotthuss proposed this concept more than 200 years ago, only indirect experimental evidence of the mechanism has been observed. Here we report the first experimental observation of proton transfer between the molecules in pure and 85% aqueous phosphoric acid. Employing dielectric spectroscopy, quasielastic neutron, and light scattering, and ab initio molecular dynamic simulations we determined that protons move by surprisingly short jumps of only ~0.5–0.7 Å, much smaller than the typical ion jump length in ionic liquids. Our analysis confirms the existence of correlations in these proton jumps. However, these correlations actually reduce the conductivity, in contrast to a desirable enhancement, as is usually assumed by a Grotthuss mechanism. Furthermore, our analysis suggests that the expected Grotthuss-like enhancement of conductivity cannot be realized in bulk liquids where ionic correlations always decrease conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular beam epitaxy synthesis and electrical transport properties of the correlated kagome metal Ni⁢ 3 In

Ni 3 ⁢In is a paramagnetic intermetallic consisting of 𝐴⁢𝐵-stacked Ni-kagome networks. Correlated electron behaviors deviating from the Fermi-liquid form have recently been observed in Ni 3 ⁢In bulk single crystals, attributed to stabilization of a partially flat electronic band near the Fermi level. Synthesis of this system in thin-film form offers unique opportunities for tuning of materials that could aid in identifying the microscopic origin of the non-Fermi-liquid response and exploring the suspected quantum criticality therein. Here, we report the realization of (001)-oriented epitaxial thin films of Ni 3 ⁢In on single-crystal SrTiO 3 (111) substrates by molecular beam epitaxy. Via control of growth conditions, we fabricate high-quality films with quantum fluctuations strongly influencing the physical properties of the system. Analysis of the electrical transport response reveals that intrinsic spin fluctuations in Ni 3 ⁢In may account for the observed non-Fermi-liquid behavior. Such structures may facilitate driving Ni 3 ⁢In across a potential quantum critical phase transition and uncover the role of unusual flat bands in triggering correlated phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High‐Efficiency Ion‐Exchange Doping of Conducting Polymers

Abstract Molecular doping—the use of redox‐active small molecules as dopants for organic semiconductors—has seen a surge in research interest driven by emerging applications in sensing, bioelectronics, and thermoelectrics. However, molecular doping carries with it several intrinsic problems stemming directly from the redox‐active character of these materials. A recent breakthrough was a doping technique based on ion‐exchange, which separates the redox and charge compensation steps of the doping process. Here, the equilibrium and kinetics of ion exchange doping in a model system, poly(2,5‐bis(3‐alkylthiophen‐2‐yl)thieno(3,2‐b)thiophene) (PBTTT) doped with FeCl 3 and an ionic liquid, is studied, reaching conductivities in excess of 1000 S cm −1 and ion exchange efficiencies above 99%. Several factors that enable such high performance, including the choice of acetonitrile as the doping solvent, which largely eliminates electrolyte association effects and dramatically increases the doping strength of FeCl 3 , are demonstrated. In this high ion exchange efficiency regime, a simple connection between electrochemical doping and ion exchange is illustrated, and it is shown that the performance and stability of highly doped PBTTT is ultimately limited by intrinsically poor stability at high redox potential.

36 MATERIALS SCIENCE↗

Lithium-sulfur battery with lithium polysulfide catholyte

A liquid catholyte for a Li-S battery comprises a non-aqueous solution of at least one lithium polysulfide of formula Li 2 S x (wherein x is selected from 4, 6, and 8) and an anion receptor compound capable of complexing with polysulfide anion. The non-aqueous solution typically is composed of the Li 2 S x and the anion receptor compound dissolved in a non-aqueous solvent (e.g., one or more organic ether or fluorinated ether solvents). The anion receptor compound typically is present in the catholyte at a concentration of about 0.1 M to about 4 M. Li-S batteries comprise a metallic lithium anode; a porous conductive substrate; a separator membrane between the anode and the porous conductive substrate; and the liquid catholyte composition within pores of the substrate.

25 ENERGY STORAGE↗

Molecular Interlocking Multidimensional Modulations of Cathode‐Electrolyte Interface for Constructing High Energy Density Quasi‐Solid‐State Batteries

Gel polymers are regarded as a promising candidate electrolyte for lithium-metal quasi-solid-state batteries, primarily due to their high ionic conductivity and solid-liquid synergistic properties. However, challenges such as interfacial side reactions, limitations in Li + transport caused by interfacial issues, and leaching of transition metals from the cathode have yet to be effectively solved. Herein, a novel gel electrolyte modulation strategy based on electrostatic filler assembly is proposed to address the issues of ineffective capacity utilization and inadequate cycling stability of high-energy-density cathode materials in solid-state lithium-ion batteries. It constructs a 3D interpenetrating charge-bridge network that effectively tackles the phase-separation challenge between fillers and electrolytes at the molecular level. Meanwhile, the molecular interlocking structure effectively inhibits the electrolyte erosion. More critically, it optimizes and stabilizes the cathode-electrolyte interface film, which facilitates the conduction of Li + -ions through a size-sieving mechanism. Consequently, this strategy enables effective adaptation across diverse high-energy-density cathode materials with satisfactory capacity performance (170.4 mAh g −1 at 4.5 V/1 C for LiNi 0.6 Co 0.2 Mn 0.2 O 2 and 194.0 mAh g −1 at 4.3 V/1 C for LiNi 0.9 Co 0.08 Mn 0.02 O 2 ). In conclusion, this investigation offers a straightforward and effective reference for addressing the critical challenges of ionic transport and interface stabilization in the design of gel electrolytes.

cathode-electrolyte interface↗