Characteristics of SBS dynamics in single-mode optical fibres

The characteristics of the gain of Stokes pulses in single-mode optical fibres by stimulated Brillouin scattering (SBS) of monochromatic and nonmonochromatic pump signals have been investigated by numerical simulation using a spectral approach. Conditions under which 'slow light' (caused by a group delay) can be implemented are found (it is reasonable to apply this term to a process in which a pulse is delayed with conservation of its shape). The plane-wave interaction model is shown to describe adequately the dynamics of this process in single-mode fibres. A number of gain modes are investigated for Stokes pulses with different time structures upon monochromatic and nonmonochromatic excitation. A new data transfer technique is proposed, which is based on the conversion of stepwise phase modulation of the input Stokes signal into amplitude modulation of the output signal. (nonlinear optical phenomena)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiscale Universal Interface: A concurrent framework for coupling heterogeneous solvers

Graphical abstract: - Abstract: Concurrently coupled numerical simulations using heterogeneous solvers are powerful tools for modeling multiscale phenomena. However, major modifications to existing codes are often required to enable such simulations, posing significant difficulties in practice. In this paper we present a C++ library, i.e. the Multiscale Universal Interface (MUI), which is capable of facilitating the coupling effort for a wide range of multiscale simulations. The library adopts a header-only form with minimal external dependency and hence can be easily dropped into existing codes. A data sampler concept is introduced, combined with a hybrid dynamic/static typing mechanism, to create an easily customizable framework for solver-independent data interpretation. The library integrates MPI MPMD support and an asynchronous communication protocol to handle inter-solver information exchange irrespective of the solvers' own MPI awareness. Template metaprogramming is heavily employed to simultaneously improve runtime performance and code flexibility. We validated the library by solving three different multiscale problems, which also serve to demonstrate the flexibility of the framework in handling heterogeneous models and solvers. In the first example, a Couette flow was simulated using two concurrently coupled Smoothed Particle Hydrodynamics (SPH) simulations of different spatial resolutions. In the second example, we coupled the deterministic SPH method with the stochastic Dissipative Particle Dynamics (DPD) method to study the effect of surface grafting on the hydrodynamics properties on the surface. In the third example, we consider conjugate heat transfer between a solid domain and a fluid domain by coupling the particle-based energy-conserving DPD (eDPD) method with the Finite Element Method (FEM)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The energy-conserving electron transfer system used by Desulfovibrio alaskensis strain G20 during pyruvate fermentation involves reduction of endogenously formed fumarate and cytoplasmic and membrane-bound complexes, Hdr-Flox and Rnf.

The adaptation capability of Desulfovibrio to natural fluctuations in electron acceptor availability was evaluated by studying Desulfovibrio alaskensis strain G20 under varying respiratory, fermentative and methanogenic coculture conditions in chemostats. Transition from lactate to pyruvate in coculture resulted in a dramatic shift in the population structure and closer interspecies cell-to-cell interactions. Lower methane production rates in coculture than predicted from pyruvate input was attributed to redirection of electron flow to fumarate reduction. Without a methanogenic partner, accumulation of H₂and formate resulted in greater succinate production. Comparative transcript and gene fitness analysis in concert with physiological data of G20 wildtype and mutants demonstrated that pyruvate fermentation involves respiration of cytoplasmically formed fumarate using cytoplasmic and membrane-bound energy-conserving complexes, Rnf, Hdr-Flox-1 and Hmc. At the low H₂/formate levels maintained in coculture, Rnf likely functions as proton-pumping ferredoxin (Fd): type-I cytochrome c oxidoreductase, which transitions to a proton-pumping Fd(red): nicotinamide adenine dinucleotide (NAD⁺) oxidoreductase at high H₂/formate levels during fermentation in monoculture. Hdr-Flox-1 is postulated to recycle Fd(red) via a flavin-based electron bifurcation involving NADH, Fdox and the thiol/disulphide-containing DsrC. In a menaquinone (MQ)-based electron confurcation reaction, the high-molecular-weight cytochrome-c₃complex, Hmc, is proposed to then couple DsrC(red) and periplasmic H₂/formate oxidation using the MQ pool to fuel a membrane-bound fumarate reductase.

Meyer, Birte↗

Experimental determination of heat transfer and friction in helically-finned tubes

Heat transfer coefficients and friction factors were determined experimentally for eight helically-finned tubes and one smooth tube using liquid water at Reynolds numbers ranging from 12,000 to 60,000. The helically-finned tubes tested in this investigation have helix angles between 25 and 48 , number of fin starts between 10 and 45, and fin height-to-diameter ratios between 0.0199 and 0.0327. An uncertainty analysis was completed and plain-tube results were compared to the Blasius and Dittus-Boelter equations with satisfactory agreement. Power-law correlations for Fanning friction and Colburn j-factors were developed using a least-squares regression. The performance of the correlations was evaluated with data of other researchers with average prediction errors between 30% and 40%. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Analysis of Experiments on Thermally Induced Dissociation of Methane Hydrates in Porous Media

Numerical simulation is essential for the prediction and evaluation of hydrocarbon reservoir performance. Numerical simulators developed for the description of the behavior of hydrates under production and the corresponding flow of fluids and heat accounting for all known processes are powerful, but they need validation through comparison to field or experimental data in order to instill confidence in their predictions. In this study, we analyze by means of numerical simulation the results of an experiment of methane hydrate dissociation by thermal stimulation in unconsolidated porous media heated through the vessel walls. The physics captured by the model include multicomponent heat and mass transfer, multiphase flow through porous media, and the phase behavior of the CH 4 + H 2 O system involved in methane hydrate formation and dissociation. The set of governing equations consists of the mass and energy conservation equations coupled with constitutive relationships, i.e., the dissolution of gas in H 2 O, relative permeability and capillary pressure models, composite thermal conductivity models, and methane hydrate phase equilibria. The model geometry describes accurately the hydrate reactor used in a recent experimental study investigating methane hydrate dissociation behavior [Chong et. al. Appl. Energy 2016, 177, 409-421]. The cumulative gas production is estimated and validated against three tests of experimental data involving different boundary temperatures, showing a good agreement between observations and numerical predictions. The predicted evolution of the spatial distributions of different phases over time shows that hydrate dissociation progresses inward from the reactor boundary to the center, methane gas accumulates to the top of the reactor because of buoyancy, and water migrates down to the bottom of the reactor because of gravity. A sharp hydrate dissociation front is predicted, and the estimated location of hydrate dissociation front suggests a linear relationship with the square root of time. A sensitivity analysis on the thermal conductivity of sand under fully saturated conditions is conducted to elucidate its effect on the gas production behavior. In addition, the energy efficiency ratio computed from the simulation of this boundary-wall heating technique varies from 14.0 to 16.2. Deviations between observations and predictions of the evolution of the temperature profile are attributed to initial heterogeneous distribution of the hydrate phase in the hydrate reactor.

42 ENGINEERING↗

Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pump shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A global model simulation for 3-D radiative transfer impact on surface hydrology over the Sierra Nevada and Rocky Mountains

We investigate 3-D mountain effects on solar flux distributions and their impact on surface hydrology over the western United States, specifically the Rocky Mountains and the Sierra Nevada, using the global CCSM4 (Community Climate System Model version 4; Community Atmosphere Model/Community Land Model – CAM4/CLM4) with a 0.23° × 0.31° resolution for simulations over 6 years. In a 3-D radiative transfer parameterization, we have updated surface topography data from a resolution of 1 km to 90 m to improve parameterization accuracy. In addition, we have also modified the upward-flux deviation (3-D–PP (plane-parallel)) adjustment to ensure that the energy balance at the surface is conserved in global climate simulations based on 3-D radiation parameterization. We show that deviations in the net surface fluxes are not only affected by 3-D mountains but also influenced by feedbacks of cloud and snow in association with the long-term simulations. Deviations in sensible heat and surface temperature generally follow the patterns of net surface solar flux. The monthly snow water equivalent (SWE) deviations show an increase in lower elevations due to reduced snowmelt, leading to a reduction in cumulative runoff. Over higher-elevation areas, negative SWE deviations are found because of increased solar radiation available at the surface. Simulated precipitation increases for lower elevations, while it decreases for higher elevations, with a minimum in April. Liquid runoff significantly decreases at higher elevations after April due to reduced SWE and precipitation.

54 ENVIRONMENTAL SCIENCES↗

A Simple Hybrid Electric Vehicle Fuel Consumption Model for Transportation Applications(DOI: 10.5772/intechopen.89055)

This study presents a simple power-based microscopic hybrid electric vehicle (HEV) fuel consumption model for use in microscopic traffic software and various connected and automated vehicle (CAV) applications, including eco-routing and eco-drive systems. While numerous HEV energy consumption models have been developed, these models are complex and require vehicle engine data deeming them difficult to implement and making them nontransferable. The proposed model was developed using empirical data for a 2010 Toyota Prius—the most popular HEV. The model was then extended to other HEVs thus extending the domain of application of the model. The proposed fuel consumption model estimates the instantaneous fuel consumption rates of an HEV using instantaneous vehicle operational input variables, including the vehicle’s speed, acceleration, and roadway grade, which can be acquired from global positioning system (GPS) equipment or other sensors. The model estimates vehicle fuel consumption rates consistent with empirical data producing an average error of 2.1% for the Toyota Prius and up to 4% for other HEVs demonstrating the applicability and transferability of the model to various HEVs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Southern Energy Homes, First DOE Zero Energy Ready Manufactured Home, Russellville, Alabama

Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes.The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductless mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat transfer during condensation of HFC-134a and R-404A inside of a horizontal smooth and micro-fin tube

In recent small and medium capacity refrigeration systems, the condenser tubes are provided with micro-fins from inside. The vapour refrigerant at the compressor outlet and the condenser inlet is in superheat state. As it advances in the condenser it is in two phases and at the outlet it is in sub cooled liquid. The heat transfer coefficient (HTC) during condensation of HFC-134a and R-404A in a smooth (8.56 mm ID) and micro-fin tubes (8.96 mm ID) are experimentally investigated. Different from previous studies, the present experiments are performed for various condensing temperatures, with superheating and sub cooling and using hermetically sealed compressor. The test runs are done at average saturated condensing temperatures ranging from 35 C to 60 C. The mass fluxes are between 90 and 800 kg m{sup -2} s{sup -1}. The experimental results indicate that the average HTC increases with mass flux but decreases with increasing condensing temperature for both smooth and micro-fin tubes. The average condensation HTCs of HFC-134a and R-404A for the micro-fin tubes were 1.5-2.5 and 1.3-2 times larger than that in smooth tube respectively. The HTCs for R-404A are less than that of HFC-134a. New correlations based on the data gathered during the experimentation for predicting condensation HTCs are proposed for wide range of operating conditions. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and Apparatus for Predicting Unsteady Pressure and Flow Rate Distribution in a Fluid Network

A method and apparatus for analyzing steady state and transient flow in a complex fluid network, modeling phase changes, compressibility, mixture thermodynamics, external body forces such as gravity and centrifugal force and conjugate heat transfer. In some embodiments, a graphical user interface provides for the interactive development of a fluid network simulation having nodes and branches. In some embodiments, mass, energy, and specific conservation equations are solved at the nodes, and momentum conservation equations are solved in the branches. In some embodiments, contained herein are data objects for computing thermodynamic and thermophysical properties for fluids. In some embodiments, the systems of equations describing the fluid network are solved by a hybrid numerical method that is a combination of the Newton-Raphson and successive substitution methods.

Majumdar, Alok K.↗

Vertical and horizontal gene transfer shaped plant colonization and biomass degradation in the fungal genus Armillaria

The fungal genus Armillaria contains necrotrophic pathogens and some of the largest terrestrial organisms that cause tremendous losses in diverse ecosystems, yet how they evolved pathogenicity in a clade of dominantly non-pathogenic wood degraders remains elusive. Here we show that Armillaria species, in addition to gene duplications and de novo gene origins, acquired at least 1,025 genes via 124 horizontal gene transfer events, primarily from Ascomycota. Horizontal gene transfer might have affected plant biomass degrading and virulence abilities of Armillaria, and provides an explanation for their unusual, soft rot-like wood decay strategy. Furthermore, combined multi-species expression data revealed extensive regulation of horizontally acquired and wood-decay related genes, putative virulence factors and two novel conserved pathogenicity-induced small secreted proteins, which induced necrosis in planta. Overall, this study details how evolution knitted together horizontally and vertically inherited genes in complex adaptive traits of plant biomass degradation and pathogenicity in important fungal pathogens.

60 APPLIED LIFE SCIENCES↗

The prediction of transonic loading on advancing helicopter rotors

Two different schemes are presented for including the effect of rotor wakes on the finie-difference prediction of rotor loads. The first formulation includes wake effects by means of a blade-surface inflow specification. This approach is sufficiently simple to permit coupling of a full-potential finite-difference rotor code to a comprehensive integral model for the rotor wake and blade motion. The coupling involves a transfer of appropriate loads and inflow data between the two computer codes. Results are compared with experimental data for two advancing rotor cases. The second rotor-wake modeling scheme is a split potential formulation for computing unsteady blade-vortex interactions. Discrete vortex fields are introduced into a three-dimensional, conservative, full-potential rotor code. Computer predictions are compared with two experimental blade-vortex interaction cases.

Strawn, R. C.↗

A study of carbon monoxide distribution determinations for a global transport model

A system of programs which model the chemistry and transport of carbon monoxide and methane in the Earth's atmosphere on a global scale was installed onto the NASA-Langley central scientific computer network. This system, the GLOBAL system, consists of a user-friendly set of procedural files which allow for simplified pre-processing, execution, and post-processing for all program elements. The package includes procedures for obtaining the NMC meteorological data, calculating the vertical winds to satisfy mass conservation, determining the boundary layer, and executing the transport/chemical model for carbon monoxide. In addition, plotting, saving to tape, and reading from tape routines were developed. Final modifications to the subprograms for processing the input data for the transport/chemistry model have improved these data to more accurately reflect true atmospheric conditions. The transfer of the transport/chemistry model from the NCAR CRAY system to the NASA-Langley VPS-32 system was completed. The problems encountered during this process and their resolutions are discussed.

Peters, Leonard K.↗

MAGNET Scaling and Methodology

The purpose of this study was to analyze the heat transfer of the Microreactor Agile Non-nuclear Experimental Testbed (MAGNET) within the Dynamic Energy Transport and Integration Laboratory (DETAIL) and develop scaling equations and models to couple with other systems. Hierarchical Two-Tiered Scaling (H2TS) methodologies were applied to DETAIL’s MAGNET facility to scale and project data sets while conserving the observed behavior based on first principles. The MAGNET system was successfully scaled using H2TS and multiple system parameters were determined or calculated from experimental data including steady state and transient data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transition to perturbative QCD

We review the Jefferson Lab program concerning the interplay between hadronic and underlying quark degrees of freedom in exclusive reactions. Much of the program was initially based on predictions from perturbative QCD (pQCD) concerning scaling of reaction cross sections, helicity conservation, and asymptotic behavior of form factors. Although much of the data do not follow simple pQCD expectations, some observables scale better than expected. Generally, the underlying dynamics are best understood with nonperturbative quark models, but the elastic deuteron form factors provide an example of the success of hadronic models to high momentum transfer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The prediction of transonic loading advancing helicopter rotors

Two different schemes are presented for including the effect of rotor wakes on the finite-difference prediction of rotor loads. The first formulation includes wake effects by means of a blade-surface inflow specification. This approach is sufficiently simple to permit coupling of a full-potential finite-difference rotor code to a comprehensive integral model for the rotor wake and blade motion. The coupling involves a transfer of appropriate loads and inflow data between the two computer codes. Results are compared with experimental data for two advancing rotor cases. The second rotor wake modeling scheme in this paper is a split potential formulation for computing unsteady blade-vortex interactions. Discrete vortex fields are introduced into a three-dimensional, conservative, full-potential rotor code. Computer predictions are compared with two experimental blade-vortex interaction cases.

Strawn, R.↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗