Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

Model predictive direct power control for active power decoupled single-phase quasi- Z -source inverter

In this study, the active power filter (APF) that consists of a half-bridge leg and an ac capacitor is integrated in the single-phase quasi-Z-source inverter (qZSI) in this paper to avoid the second harmonic power flowing into the dc side. The capacitor of APF buffers the second harmonic power of the load, and the ac capacitor allows highly pulsating ac voltage, so that the capacitances of both dc and ac sides can be small. A model predictive direct power control (DPC) is further proposed to achieve the purpose of this newtopology through predicting the capacitor voltage of APF at each sampling period and ensuring the APF power to track the second harmonic power of single-phase qZSI. Simulation and experimental results verify the model predictive DPC for the APF-integrated single-phase qZSI.

30 DIRECT ENERGY CONVERSION↗

Effect of Organic Coatings, Humidity and Aerosol Acidity on Multiphase Chemistry of Isoprene Epoxydiols

Multiphase chemistry of isomeric isoprene epoxydiols (IEPOX) has been shown to be the dominant source of isoprene-derived secondary organic aerosol (SOA). Recent studies have reported particles composed of ammonium bisulfate (ABS) mixed with model organics exhibit slower rates of IEPOX uptake. In the present study, we investigate the effect of atmospherically-relevant organic coatings of α-pinene (AP) SOA on the reactive uptake of trans-β-IEPOX onto ABS particles under different conditions and coating thicknesses. Single particle mass spectrometry was used to characterize in real-time particle size, shape, density, and quantitative composition before and after reaction with IEPOX. We find that IEPOX uptake by pure sulfate particles is a volume-controlled process, which results in particles with uniform concentration of IEPOX-derived SOA across a wide range of sizes. Aerosol acidity was shown to enhance IEPOX-derived SOA formation, consistent with recent studies. The presence of water has a weaker impact on IEPOX-derived SOA yield, but significantly enhanced formation of 2-methyltetrols, consistent with offline filter analysis. In contrast, IEPOX uptake by ABS particles coated by AP-derived SOA is strongly dependent on particle size and composition. IEPOX uptake occurred only when weight fraction of AP-derived SOA dropped below 50 %, effectively limiting IEPOX uptake to larger particles.

Environmental Molecular Sciences Laboratory↗

Strategies toward the Synthesis of Advanced Functional Sorbent Performance for Uranium Uptake from Seawater

A polymer fiber-based adsorbent (AF1) composed of acrylonitrile and itaconic acid functional groups was synthesized by a radiation-induced graft polymerization technique onto hollow-gear shaped polyethylene (PE) fibers. Investigation of the optimum reaction parameters for the conversion of grafted cyano moieties into amidoxime groups was conducted by the reaction with hydroxylamine at different temperatures and periods in a variety of aqueous and organic solvents. The 13 C CP/MAS spectra of amidoximated AF1 adsorbent fibers from water–methanol and dimethyl sulfoxide (DMSO) revealed that both the cyclic imide dioxime and open-chain amidoxime were formed through the reaction. The conversion from amidoxime to imide dioxime was found to occur slowly and gradually with the increasing reaction time. The quicker diffusion of DMSO as compared to that of water–methanol, in the grafted trunk PE fiber, resulted in faster kinetics of the amidoximation reaction. The uranium adsorption capacity of the amidoximated AF1 samples was determined after (i) 24 h contact with sodium-based brine spiked with uranium and (ii) 56 days of exposure to filtered seawater (Sequim Bay, WA, USA) in flow-through columns. Finally, the uranium extraction performance of the adsorbents after exposure to filtered seawater was consistent with the laboratory screening results, and the amidoximated AF1 samples (in DMSO at 70 °C for 3 h) exhibited the highest 56 day uranium adsorption capacity (5.04 ± 0.15 g U/kg-ads) with faster adsorption kinetics compared to the pristine AF1 adsorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical detection of spin hyperpolarization in InP

The electrical detection of surface spin polarization in Indium Phosphide (InP) is demonstrated. Using a planar four-terminal architecture on top of semi-insulating Fe:InP (001) wafers, optical orientation is separated from electrical detection. Spin filter tunnel contacts consisting of InP/oxide/Co reveal significant asymmetries in the differential resistance upon helicity change of the optical pumping. The iron-rich tunnel oxide provides the main spin selection mechanism. A reproducible helicity-dependent asymmetry as high as 18% could be observed at T = 55 K and an external induction field μ{sub 0}H = 1 T. At room temperature and zero external field, a helicity-dependent asymmetry of 6% suggests the stand-alone applicability of the device either as an electronic spin sensor or as an optical helicity sensor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gain and frequency tuning within the mouse cochlear apex

Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase Picking Beyond Local Distances: Where Waveform Filtering Still Matters for Deep Learning Models

Waveform filtering is a standard step in traditional seismic phase picking but often receives little attention in deep learning workflows, where models are typically trained on raw or minimally processed waveforms. Although this strategy performs well for local events, we show that performance can degrade substantially at regional distances. To address this limitation, we introduce two ways to incorporate multiband-filtered waveforms into deep learning phase pickers. The stacking approach concatenates filtered inputs along the channel dimension, while the branching approach processes each frequency band through a dedicated network branch before feature fusion. Both approaches can substantially improve performance across epicentral distances of 0° to 20°, but their effectiveness depends strongly on the selected frequency bands. Tests with multiple filter banks show that filter-bank design should be treated as part of model optimization rather than as a fixed preprocessing choice. Grad-CAM analysis of the branching model indicates that band importance varies among waveform samples and across training realizations, with only a weak overall preference for the 0.25 to 0.5 Hz band. These results show that no single filter band is consistently optimal and demonstrate that explicit feature engineering remains valuable for robust deep learning-based seismic phase picking.

58 GEOSCIENCES↗

Interim Status of HEPA Filter 10-Year Lifetime Evaluation

High efficiency particulate air (HEPA) filters are used to remove a variety of particles from industrial gas streams. HEPA filters remove at least 99.97% of airborne particles 0.3 microns in diameter, while particles smaller or larger than 0.3 microns are removed with an even higher efficiency. The purpose of this study is to draw a relationship between the HEPA filter lifespan and various competing factors that include the differential pressure drop in nuclear grade HEPA filters, the fume hood face velocity, the radiological dose, and the filter efficiency characteristics. The Department of Energy (DOE) uses a conservative interpretation of data to set the age limit of HEPA filters at 10 years (DOE-HDBK-1169-2003). The lifetime was determined by an analysis of multiple HEPA filter research studies, performed by Bergman at the Lawrence Livermore National Laboratory (LLNL). Analysis of data from Robinson et al. suggests that unfolded media tensile strength fail at 13 years, while folded media do not have the required 2.5 pound/inch tensile strength even when new and is extremely low at 7 years. Therefore, the data displayed failed tensile strength and low burst strengths at an average of 10 years. Although filter life was difficult to estimate using the data, based on the relationship between HEPA filter and their age, the recommended lifetime was set at 10 years under dry conditions (Bergman 1999). Effluent Management (EM) is coordinating a 10-year effort to collect and analyze the lifetime of HEPA filters against the other competing requirements. The study began in 2010 and consists of 49 HEPA filters that are analyzed annually to verify compliance with permit conditions. The data are collected from the Physical Science Facility (PSF) 3410, 3420, and 3430 buildings located at the Pacific Northwest National Laboratory (PNNL). The study suggests the frequency of filter replacement should also be based on the differential pressure, filter efficiency, and/or face velocity of the fume hood, rather than a prescribed filter “lifetime”, which is currently every 10 years from the date of manufacture for filters operating under dry conditions. Over the past six years, only two filters in the study were replaced: one due to high DP and low fume hood face velocity, and the other due to low filter efficiency results.

54 ENVIRONMENTAL SCIENCES↗

Water-Resistant Container Testing CNUT INGB Container Design (Rev. 1)

The purpose of this report is to detail the results of water ingress testing conducted on the 5Qt Castle Nut In-Glovebox (5QtCNUT INGB) container design and discuss these results against the water-resistant container requirements of TA55-AP- 522 and PA-RD-01009. The CNUT is a general-purpose container option for material storage inside of a glovebox and/or as an approved non-hermetically sealed inner of an approved packaging configuration inside of an approved outer container as listed in PA-RD-01022. The CNUT containment boundary consists of a filtered lid and deep drawn body with welded collar all made of 316L stainless steel, an aluminum bronze spin down ring to provide compression of a to Viton® O-ring to create a seal for closure and containment.

36 MATERIALS SCIENCE↗

Maximum likelihood synchronizer for binary overlapping PCM/NRZ signals.

A maximum likelihood parameter estimation technique for the self bit synchronization problem is investigated. The input sequence to the bit synchronizer is a sequence of binary overlapping PCM/NRZ signal in the presence of white Gaussian noise with zero mean and known variance. The resulting synchronizer consists of matched filters, a transition device and a weighting function. Finally, the performance is examined by Monte Carlo simulations.

Wang, C. D.↗

Unichromatic-carrier color-TV system

Optical system consists of two filter layers with each layer composed of transparent stripes alternating with dichroic color filter strips. System produces color multiplexed light signal by vertically orienting dichroic filter stripes perpendicular to scan lines of image tube.

Vorhaben, K. H.↗

Transfer of contrast sensitivity in linear visual networks

Contrast sensitivity is a useful measure of the ability of an observer to distinguish contrast signals from noise. Although usually applied to human observers, contrast sensitivity can also be defined operationally for individual visual neurons. In a model linear neuron consisting of a filter and noise source, this operational measure is a function of filter gain, noise power spectrum, signal duration, and a performance criterion. This definition allows one to relate the sensitivities of linear neurons at different levels in the visual pathway. Mathematical formulas describing these relationships are derived, and the general model is applied to the specific problem of relating the sensitivities of parvocellular LGN neurons and cortical simple cells in the primate.

Watson, Andrew B.↗

An improved conscan algorithm based on a Kalman filter

Conscan is commonly used by DSN antennas to allow adaptive tracking of a target whose position is not precisely known. This article describes an algorithm that is based on a Kalman filter and is proposed to replace the existing fast Fourier transform based (FFT-based) algorithm for conscan. Advantages of this algorithm include better pointing accuracy, continuous update information, and accommodation of missing data. Additionally, a strategy for adaptive selection of the conscan radius is proposed. The performance of the algorithm is illustrated through computer simulations and compared to the FFT algorithm. The results show that the Kalman filter algorithm is consistently superior.

Eldred, D. B.↗

The composition of a coronal active region

The relative abundances of iron, oxygen, magnesium, and neon in a coronal active region are determined from measurements of soft X-ray line and broadband intensities. The emission measure, temperature, and column density are derived from these measured intensities and are used to place a constraint on the abundances of the heavier elements relative to hydrogen in the corona. The intensity measurements were made on 1987 December 11, when an active region was observed jointly by the American Science and Engineering (AS&E) High Resolution Soft X-Ray Imaging Sounding-Rocket Payload and the X-Ray Polychromator Flat Crystal Spectrometer (FCS) onboard the Solar Maximum Mission spacecraft. The coordinated observations include images through two broadband filters (8 to 29 A and 8 to 39, 44 to 60 A) and profiles of six emission lines: Fe XVII (15.01 A), FE VIII (15.26 A), O VIII (18.97 A), Mg XI (9.17 A), Ne IX (13.44 A), and Fe XVIII (14.21 A). The effects of resonance scattering are considered in the interpretation of the FCS line intensities. We calculated the expected intensity ratio of the two Fe XVII lines as a function of optical depth and compared this ratio with the observed intensity ratio to obtain the optical depths of each of the lines and the column density. The line intensities and the broadband filtered images are consistent with the emission from a thermal plasma where Fe, O, Mg, and Ne have the 'adopted coronal' abundances of Meyer (1985b) relative to one another, but are not consistent with the emission from a plasma having photospheric abundances: The ratios of the abundances of the low first ionization potential (FIP) elements (Fe and Mg) to the abundances of the high-FIP elements (Ne and O) are higher than the ratios seen in the photosphere by a factor of about 3.5. This conclusion is independent of the assumption of either an isothermal or a multithermal plasma. The column densities derived from the Fe XVII line ratio and the geometry of the active region provide a diagnostic of the abundance of hydrogen relative to the heavier elements. We find that the abundance of iron with respect to hydrogen in the corona is higher than the value given Meyer (1985b) by a factor of 8.2(-5.4, +5.1). This means that, for the observed active region, the absolute abundances of the low-FIP elements (Fe and Mg) are enhanced in the corona relative to the photosphere, while the abundances of the high-FIP elements (Ne and O) are either slightly enhanced in the corona or nearly the same in the photosphere and the corona.

Waljeski, K.↗

Early Radiometric Validation Results of the Ceres Flight Model 1 and 2 Instruments Onboard NASA's Terra Spacecraft

The CERES Flight Model 1 and 2 instruments were launched aboard NASA's Earth Observing System (EOS) Terra Spacecraft on December 18, 1999 into a 705 Km sun-synchronous orbit with a 10:30 a.m. equatorial crossing time. These instruments supplement measurements made by the CERES Proto Flight Model (PFM) instrument launched aboard NASA's Tropical Rainfall Measuring Mission (TRMM) spacecraft on November 27, 1997 into a 350 Km, 38-degree mid-inclined orbit. An important aspect of the EOS program is the rapid archival and dissemination of datasets measured by EOS instruments to the scientific community. On September 22, 2000 the CERES Science Team voted to archive the Edition 1 CERES/Terra Level 1b and Level 2 and 3 ERBE-Like data products. These products consist of instantaneous filtered and unfiltered radiances through temporally and spatially averaged TOA fluxes. CERES filtered radiance measurements cover three spectral bands including shortwave (0.3 to 5 micron), total (0.3 to less than 100 microns) and an atmospheric window channel (8 to 12 microns). The current work summarizes both the philosophy and results of validation efforts undertaken to quantify the quality of the Terra data products as well as the level of agreement between the Terra and TRMM datasets.

Priestley, K. J.↗