Search NASA⌕ Search

SEARCH · Search NASA

Results for “contact mechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Magnetic Bearing With Radial and Angular Control

Active magnetic bearing stably levitates rotor against radial (lateral) and axial motion and points rotor axis in controllable direction, yet allows rotor to turn freely about own axis. Rotor only moving part, and absence of mechanical contact between rotor and stator assures long life. Active magnetic bearing includes electromagnet coils tilting rotor clockwise or counterclockwise, or move it right or left. Feedback control system maintains rotor at equilibrium radial and angular positions in response to signals from position sensors. No active control needed to maintain equilibrium axial position. Adjustable magnetic bearing useful in high-speed rotating devices, robotic joints, and supports for optical elements.

Studer, P. A.↗

Apparatus and method of capturing an orbiting spacecraft

Apparatus and a method of capturing an orbiting spacecraft by attaching a grapple fixture are discussed. A probe is inserted into an opening, such as a rocket nozzle, in the spacecraft until a stop on the prove mechanism contacts the spacecraft. A lever is actuated releasing a spring loaded rod which moves axially along the probe removing a covering sleeve to expose spring loaded toffle fingers which pivot open engaging the side of the opening. The probe is shortened and tensioned by turning a screw thread, pressing the fingers inside of the opening to compress the spacecraft between the toggle fingers and the stop. A grapple fixture attached to the probe, which is thus secured to the spacecraft, is engaged by appropriate retrieval means such as a remote manipulator arm.

Harwell, William D.↗

Dynamic response of a magnetically suspended flywheel with mass unbalance

The forced translational and rotational motion of a magnetically suspended flywheel due to mass unbalance is investigated. It is found that a magnetically suspended flywheel can tolerate greater mass unbalance than a conventional rotor system because in a magnetic suspension system, vibration and the transmission of dynamic loads are eliminated in the absence of mechanical contact. It is shown that although vibration and dynamic loads are not transmitted between the rotor and stator of a magnetically suspended flywheel, inertial forces and moments due to mass unbalance are generated when the flywheel is spinning. Numerical results demonstrate that the inertial forces and moments cause the flywheel to tilt and to displace radially from its centered position.

Wong, Kenneth↗

Mechanism test bed. Flexible body model report

The Space Station Mechanism Test Bed is a six degree-of-freedom motion simulation facility used to evaluate docking and berthing hardware mechanisms. A generalized rigid body math model was developed which allowed the computation of vehicle relative motion in six DOF due to forces and moments from mechanism contact, attitude control systems, and gravity. No vehicle size limitations were imposed in the model. The equations of motion were based on Hill's equations for translational motion with respect to a nominal circular earth orbit and Newton-Euler equations for rotational motion. This rigid body model and supporting software were being refined.

Compton, Jimmy↗

Composite material shear property measurement using the Iosipescu specimen

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Finite element analysis and moire interferometry are used to assess the uniformity of the shear stress field in the test section of unidirectional and cross-ply graphite-epoxy composites. The nonuniformity of the strain field and the sensitivity of some fiber orientations to the specimen/fixture contact mechanics are discussed. The shear responses obtained for unidirectional and cross-ply graphite-epoxy composites are discussed and problems associated with anomalous behavior are addressed. An experimental determination of the shear response of a range of material systems using strain gage instrumentation and moire interferometry is performed.

Ho, Henjen↗

High Speed Solid State Circuit Breaker

The U.S. Army Research Laboratory, Fort Monmouth, NJ, has developed and is installing two 3.3 MW high speed solid state circuit breakers at the Army's Pulse Power Center. These circuit breakers will interrupt 4160V three phase power mains in no more than 300 microseconds, two orders of magnitude faster than conventional mechanical contact type circuit breakers. These circuit breakers utilize Gate Turnoff Thyristors (GTO's) and are currently utility type devices using air cooling in an air conditioned enclosure. Future refinements include liquid cooling, either water or two phase organic coolant, and more advanced semiconductors. Each of these refinements promises a more compact, more reliable unit.

Podlesak, Thomas F.↗

Engineering science research issues in high power density transmission dynamics for aerospace applications

This paper discusses analytical and experimental approaches that will be needed to understand dynamic, vibro-acoustic and design characteristics of high power density rotorcraft transmissions. Complexities associated with mathematical modeling of such systems will be discussed. An overview of research work planned during the next several years will be presented, with emphasis on engineering science issues such as gear contact mechanics, multi-mesh drive dynamics, parameter uncertainties, vibration transmission through bearings, and vibro-acoustic characteristics of geared rotor systems and housing-mount structures. A few examples of work in progress are cited.

Singh, Rajendra↗

Noncontact Acousto-Ultrasonic Testing With Laser Beams

Laser beams used to excite and detect acoustic waves in specimens. Laser/acousto-ultrasonic technique entails no mechanical contact between specimens and testing apparatus. Apparatus located at relatively large distances (meters) from specimens, making it possible to test specimens too hot for contact measurements or located in inaccessible places, vacuums, or hostile environments.

Huber, Robert D.↗

Electromagnetically levitated vibration isolation system for the manufacturing process of silicon monocrystals

This paper introduces a study on an Electromagnetically Levitated Vibration Isolation System (ELVIS) for isolation control of large-scale vibration. This system features no mechanical contact between the isolation table and the installation floor, using a total of four electromagnetic actuators which generate magnetic levitation force in the vertical and horizontal directions. The configuration of the magnet for the vertical direction is designed to prevent any generation of restoring vibratory force in the horizontal direction. The isolation system is set so that vibration control effects due to small earthquakes can be regulated to below 5(gal) versus horizontal vibration levels of the installation floor of up t 25(gal), and those in the horizontal relative displacement of up to 30 (mm) between the floor and levitated isolation table. In particular, studies on the relative displacement between the installation floor and the levitated isolation table have been made for vibration control in the horizontal direction. In case of small-scale earthquakes (Taft wave scaled: max. 25 gal), the present system has been confirmed to achieve a vibration isolation to a level below 5 gal. The vibration transmission ratio of below 1/10 has been achieved versus continuous micro-vibration (approx. one gal) in the horizontal direction on the installation floor.

Kanemitsu, Yoichi↗

Superconductive material and magnetic field for damping and levitation support and damping of cryogenic instruments

A superconductive load bearing support without a mechanical contact and vibration damping for cryogenic instruments in space is presented. The levitation support and vibration damping is accomplished by the use of superconducting magnets and the 'Meissner' effect. The assembly allows for transfer of vibration energy away from the cryogenic instrument which then can be damped by the use of either an electronic circuit or conventional vibration damping mean.

Dolgin, Benjamin P.↗

Development of the dynamic motion simulator of 3D micro-gravity with a combined passive/active suspension system

The establishment of those in-orbit operations like 'Rendez-Vous/Docking' and 'Manipulator Berthing' with the assistance of robotics or autonomous control technology, is essential for the near future space programs. In order to study the control methods, develop the flight models, and verify how the system works, we need a tool or a testbed which enables us to simulate mechanically the micro-gravity environment. There have been many attempts to develop the micro-gravity testbeds, but once the simulation goes into the docking and berthing operation that involves mechanical contacts among multi bodies, the requirement becomes critical. A group at the Tokyo Institute of Technology has proposed a method that can simulate the 3D micro-gravity producing a smooth response to the impact phenomena with relatively simple apparatus. Recently the group carried out basic experiments successfully using a prototype hardware model of the testbed. This paper will present our idea of the 3D micro-gravity simulator and report the results of our initial experiments.

Yoshida, Kazuya↗

An Evaluation of the Iosipescu Specimen for Composite Materials Shear Property Measurement

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. An experimental investigation using conventional strain gage instrumentation and moire interferometry is performed. A finite element analysis of the Iosipescu shear test for unidirectional and cross-ply composites is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon the strain gage measurements used for the determination of composite shear moduli. From the test results for graphite-epoxy laminates, it is shown that the proximity of the load introduction point to the test section greatly influences the individual gage readings for certain fiber orientations but the effect upon shear modulus measurement is relatively unimportant. A numerical study of the load contact effect shows the sensitivity of some fiber configurations to the specimen/fixture contact mechanism and may account for the variations in the measured shear moduli. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and yielded spurious shear stress-strain curves. In the numerical analysis, it is shown that the Iosipescu specimens for different fiber orientations have to be modeled differently in order to closely approximate the true loading conditions. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors, which are determined for the region occupied by the strain gage rosette, are found to be dependent upon the material orthotropic ratio and the finite element models. Based upon the experimental and numerical results, recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed. Further application of the Iosipescu shear test to woven fabric composites is presented. The limitations of the traditional strain gage instrumentation on the satin weave and high tow plain weave fabrics is discussed. Test results of a epoxy based aluminum particulate composite is also presented. A modification of the Iosipescu specimen is proposed and investigated experimentally and numerically. It is shown that the proposed new specimen design provides a more uniform shear stress field in the test section and greatly reduces the normal and shear stress concentrations in the vicinity of the notches. While the fabrication and the material cost of the proposed specimen is tremendously reduced, it is shown the accuracy of the shear modulus measurement is not sacrificed.

Ho, Henjen↗

Fiber-matrix interphase characterization in composites using ultrasonic velocity data

A nondestructive method is introduced to determine the effective elastic of fiber-matrix interphases from measured composite moduli. The composite moduli are obtained by measuring the angular dependences of ultrasonic longitudinal and transverse phase velocities in planes along and perpendicular to the fibers. Three independent interphase effective moduli are found using micromechanical multiphase models which were applied after averaging composite transverse moduli to account for the composite orthotropy. Sensitivity analysis shows that errors in the calculated interphasial moduli are approximately ten times those in the composite moduli. Experiments are performed on Si3N4 ceramic and Ti-24Al-11Nb intermetallic matrix composites reinforced with carbon coated silicon carbide fibers. The experimental interphasial moduli for the intermetallic composites agree with literature data after accounting for the interphase microstructure. The interphasial moduli for ceramic composites are lower than those for the intermetallic composite due to imperfect mechanical contact between the interphase and the porous matrix. The use of the method to assess the interphase degradation is demonstrated for interphasial oxidation damage. The analysis helps to determine the morphology of the damaged interphase.

Chu, Y. C.↗

Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

Moriyama, Shin-Ichi↗

Thermal Switch for Satellite Temperature Control

An active radiator tile (ART) thermal valve has been fabricated using silicon micromachining. Intended for orbital satellite heat control applications, the operational principal of the ART is to control heat flow between two thermally isolated surfaces by bring the surfaces into intimate mechanical contact using electrostatic actuation. Prototype devices have been tested in a vacuum and demonstrate thermal actuation voltages as low as 40 volts, very good thermal insulation in the OFF state, and a large increase in radiative heat flow in the ON state. Thin, anodized aluminum was developed as a coating for high infrared emissivity and high solar reflectance.

Ziad, H.↗

2003 NASA Seal/Secondary Air System Workshop

The following reports were included in the 2003 NASA Seal/Secondary Air System Workshop:Low Emissions Alternative Power (LEAP); Overview of NASA Glenn Seal Developments; NASA Ultra Efficient Engine Technology Project Overview; Development of Higher Temperature Abradable Seals for Industrial Gas Turbines; High Misalignment Carbon Seals for the Fan Drive Gear System Technologies; Compliant Foil Seal Investigations; Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts; Controls Considerations for Turbine Active Clearance Control; Non-Contacting Finger Seal Developments and Design Considerations; Effect of Flow-Induced Radial Load on Brush Seal/Rotor Contact Mechanics; Seal Developments at Flowserve Corporation; Investigations of High Pressure Acoustic Waves in Resonators With Seal-Like Features; Numerical Investigations of High Pressure Acoustic Waves in Resonators; Feltmetal Seal Material Through-Flow; "Bimodal" Nuclear Thermal Rocket (BNTR) Propulsion for Future Human Mars Exploration Missions; High Temperature Propulsion System Structural Seals for Future Space Launch Vehicles; Advanced Control Surface Seal Development for Future Space Vehicles; High Temperature Metallic Seal Development for Aero Propulsion and Gas Turbine Applications; and BrazeFoil Honeycomb.

Steinetz, Bruce M.↗

Rapid adaptation to Coriolis force perturbations of arm trajectory

1. Forward reaching movements made during body rotation generate tangential Coriolis forces that are proportional to the cross product of the angular velocity of rotation and the linear velocity of the arm. Coriolis forces are inertial forces that do not involve mechanical contact. Virtually no constant centrifugal forces will be present in the background when motion of the arm generates transient Coriolis forces if the radius of body rotation is small. 2. We measured the trajectories of arm movements made in darkness to a visual target that was extinguished as movement began. The reaching movements were made prerotation, during rotation at 10 rpm in a fully enclosed rotating room, and postrotation. During testing the subject was seated at the center of the room and pointed radially. Neither visual nor tactile feedback about movement accuracy was present. 3. In experiment 1, subjects reached at a fast or slow rate and their hands made contact with a horizontal surface at the end of the reach. Their initial perrotary movements were highly significantly deviated relative to prerotation in both trajectories and end-points in the direction of the transient Coriolis forces that had been generated during the reaches. Despite the absence of visual and tactile feedback about reaching accuracy, all subjects rapidly regained straight movement trajectories and accurate endpoints. Postrotation, transient errors of opposite sign were present for both trajectories and endpoints. 4. In a second experiment the conditions were identical except that subjects pointed just above the location of the extinguished target so that no surface contact was involved. All subjects showed significant initial perrotation deviations of trajectories and endpoints in the direction of the transient Coriolis forces. With repeated reaches the trajectories, as viewed from above, again became straight, but there was only partial restoration of endpoint accuracy, so that subjects reached in a straight line to the wrong place. Aftereffects of opposite sign were transiently present in the postrotary movements. 5. These observations fail to support current equilibrium point models, both alpha and lambda, of movement control. Such theories would not predict endpoint errors under our experimental conditions, in which the Coriolis force is absent at the beginning and end of a movement. Our results indicate that detailed aspects of movement trajectory are being continuously monitored on the basis of proprioceptive feedback in relation to motor commands. Adaptive compensations can be initiated after one perturbation despite the absence of either visual or tactile feedback about movement trajectory and endpoint error. Moreover, movement trajectory and end-point can be remapped independently.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Large-Area Atomic Oxygen Facility Used to Clean Fire-Damaged Artwork

In addition to completely destroying artwork, fires in museums and public buildings can soil a displayed artwork with so much accumulated soot that it can no longer be used for study or be enjoyed by the public. In situations where the surface has not undergone extensive charring or melting, restoration can be attempted. However, soot deposits can be very difficult to remove from some types of painted surfaces, particularly when the paint is fragile or flaking or when the top surface of the paint binder has been damaged. Restoration typically involves the use of organic solvents to clean the surface, but these solvents may cause the paint layers to swell or leach out. Also, immersion of the surface or swabbing during solvent cleaning may move or remove pigment through mechanical contact, especially if the fire damage extends into the paint binder. A noncontact technique of removing organic deposits from surfaces was developed out of NASA research on the effects of oxygen atoms on various materials. Atomic oxygen is present in the atmosphere surrounding the Earth at the altitudes where satellites typically orbit. It can react chemically with surface coatings or deposits that contain carbon. In the reaction, the carbon is converted to carbon monoxide and some carbon dioxide. Water vapor is also a byproduct of the reaction if the surface contains carbon-hydrogen bonds. To study this reaction, NASA developed Earth-based facilities to produce atomic oxygen for material exposure and testing. A vacuum facility designed and built by the Electro-Physics Branch of the NASA Glenn Research Center at Lewis Field to provide atomic oxygen over a large area for studying reactions in low Earth orbit has been used to successfully clean several full-size paintings. (This facility can accommodate paintings up to 1.5 by 2.1 m. The atomic oxygen plasma is produced between two large parallel aluminum plates using a radiofrequency power source operating at roughly 400 W. Atomic oxygen is generated uniformly over this area at an operating pressure of 1 to 5 mtorr.

Rutledge, Sharon K.↗