Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Results of investigations on a 0.010-scale 140A/B configuration space shuttle vehicle orbiter model 72-0 in the NASA/Langley Research Center continuous flow hypersonic tunnel (OA90)

Data are documented which were obtained during wind tunnel tests. The test was conducted beginning 4 March and ending 6 March 1974 for a total of 24 occupancy hours. all test runs were conducted at a Mach number of 10.3 and at Reynolds numbers of 0.65, 1.0 and 1.33 million per foot. Only the complete 140A/B was tested with various elevon, speedbrake, and bodyflap settings at angles of attack from 12 to 37 degrees at 0 and -5 degrees of beta, and from 0 to -9 degrees of beta at 20 and 30 degrees angle of attack. The purpose was to obtain hypersonic longitudinal and lateral-directional stability and control characteristics of the updated space shuttle vehicle configuration.

Hawthorne, P. J.↗

Sample stream distortion modeled in continuous-flow electrophoresis

Buoyancy-induced disturbances in an electrophoresis-type chamber were investigated. Five tracer streams (latex) were used to visualize the flows while a nine-thermistor array sensed the temperature field. The internal heating to the chamber was provided by a 400 Hz electrical field. Cooling to the chamber was provided on the front and back faces and, in addition, on both chamber side walls. Disturbances to the symmetric base flow in the chamber occurred in the broad plane of the chamber and resulted from the formation of lateral and axial temperature gradients. The effect of these gradients was to retard or increase local flow velocities at different positions in the chamber cross section, which resulted in lateral secondary flows being induced in the broad plane of the chamber. As the adverse temperature gradients increased in magnitude, the critical Rayleigh number was approached and reverse (separated) flow became apparent, which, subsequently, led to the onset of time variant secondary flows.

Rhodes, P. H.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Those aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described with emphasis on the instrumentation and data acquisition system used in the Langley 0.3 m transonic cryogenic tunnel. Typical calibration results obtained in a 20 by 60 cm two dimensional test section are included.

Ladson, C. L.↗

Selection and application of instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Selection and application of calibration and control instrumentation influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described. The instrumentation and data acquisition system used in the Langley 0.3 m transonic tunnel are described along with typical calibration data obtained in a 20 by 60 cm two dimensional test section.

Kilgore, R. A.↗

Instrumentation for calibration and control of a continuous-flow cryogenic tunnel

Aspects of selection and application of calibration and control instrumentation that are influenced by the extremes in the temperature environment to be found in cryogenic tunnels are described. The instrumentation and data acquisition system used in the 0.3-m transonic cryogenic tunnel along with typical calibration data obtained in a 20 by 60 cm two dimensional test section are described.

Ladson, C. L.↗

Performance of the continuous flow diffusion chambers

A brief comparative description is made of the chambers. Overall, comparisons for the various types of experiments - monodisperse, polydisperse and ambient aerosol - showed agreement among these chambers to within 15% in most cases. A careful analysis of the results indicated that a proper accounting of certain parameters would bring about much closer agreement among four of these instruments.

Hudson, J. G.↗

Design considerations of a thermally stabilized continuous flow electrophoresis chamber 2

The basic adjustable parameters of a Beckman Continouous Particle Electrophoresis (CPE) Apparatus are investigated to determine the optimum conditions for ground based operation for comparison with space experiments. The possible application of electrically insulated copper/aluminum chamber walls is evaluated as a means to thermally stabilize or equilibrate lateral temperature gradients which exist on the walls of conventional plastic chambers and which distort the rectilinear base flow of buffer through the chamber, significantly affecting sample resolution.

Jandebeur, T. S.↗

Continuous-Flow Centrifugal Separator

Apparatus combines principles of centrifugal and cyclone separators to control movement of solid or liquid particles suspended in flowing gas. Spinning disk contains radial channels, width varys as function of distance from center. Gas flows from outer ring around disk toward center. Particles in gas collected at periphery, center or both.

Waldron, Robert D.↗

Unique, clean-air, continuous-flow, high-stagnation-temperature facility for supersonic combustion research

Accurate, spatially-resolved measurements can be conducted of a model supersonic combustor in a clean air/continuous flow supersonic combustion facility whose long run times will allow not only the point-by-point mapping of flow field variables with laser diagnostics but facilitate the simulation of steady-state combustor conditions. The facility will provide a Mach 2 freestream with static pressures in the 1 to 1/6 atm range, and stagnation temperatures of up to 2000 K.

Krauss, R. H.↗

Laser Doppler velocimetry for continuous flow solar-pumped iodine laser system

A laser Doppler velocimetry (LDV) system was employed to measure the flow velocity profile of iodide vapor inside laser tubes of 36 mm ID and 20 mm ID. The LDV, which was operated in the forward scatter mode used a low power (15 mW) He-Ne laser beam. Velocity ranges from 1 m/s was measured to within one percent accuracy. The flow velocity profile across the laser tube was measured and the intensity of turbulence was determined. The flow of iodide inside the laser tube demonstrated a mixture of both turbulence and laminar flow. The flowmeter used for the laser system previously was calibrated with the LDV and found to be in good agreement.

Tabibi, Bagher M.↗

Experimental and Theoretical Studies of Surging in Continuous-Flow Compressors

Experiments have been conducted to determine the conditions that cause surging in compressors and to determine the effect of various installations and operating conditions on the character of the velocity and pressure variations occurring during surging. These investigations were made on three compressor units and the variation of static, total, and velocity pressure with time was recorded. In addition to the experimental studies, a simplified analysis was made to determine how instability of flow may occur in a compressor. Based on this analysis, an examination was made of several possible methods of inhibiting the occurrence of surging.

Bullock, Robert O↗

A commercialized, continuous flow fiber optic sensor for trichloroethylene and haloforms

Purus, Inc. has commercialized a fiber optic chemical sensor using technology developed by Lawrence Livermore National Laboratory and licensed from The University of California. The basis for the sensor is the development of color within a reagent when exposed to an analyte. The sensor consists of an optrode, reagent delivery and recover system, fiber optic transmitter-receiver, controller, and display. Reagent is pumped through the optrode. Analyte diffuses across a gas permeable membrane and reacts with the reagent to form a colored product. The colored product is detected by measuring the absorbance of light from a 568 nm diode. Reagents are currently available for TCE and trihalomethanes. Initial reagent chemistry is based on the Fujiwara alkaline pyridine reaction. The optrode contacts only gas streams, but the volatility of the current analytes also allows measurements of aqueous streams, without being affected by aqueous interferents that are non-volatile. Sensitivity of the sensor has been demonstrated to 5 ppb aqueous solutions and 0.1 ppmv in flowing gas streams.

Wells, James C.↗

Dual-Mode Combustion of Hydrogen in a Mach 5, Continuous-Flow Facility

Results of an experimental and numerical study of a dual-mode scramjet combustor are reported. The experiment consisted of a direct-connect test of a Mach 2 hydrogen-air combustor with a single unswept-ramp fuel injector. The flow stagnation enthalpy simulated a flight Mach number of 5. Measurements were obtained using conventional wall instrumentation and a particle-imaging laser diagnostic technique. The particle imaging was enabled through the development of a new apparatus for seeding fine silicon dioxide particles into the combustor fuel stream. Numerical simulations of the combustor were performed using the GASP code. The modeling, and much of the experimental work, focused on the supersonic combustion mode. Reasonable agreement was observed between experimental and numerical wall pressure distributions. However, the numerical model was unable to predict accurately the effects of combustion on the fuel plume size, penetration, shape, and axial growth.

Goyne, C. P.↗