Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Demonstration of on Sky Contrast Improvement Using the Modified Gerchberg-Saxton Algorithm at the Palomar Observatory

We have successfully demonstrated significant improvements in the high contrast detection limit of the Well-Corrected Subaperture (WCS) using the Autonomous Phase Retrieval Calibration (APRC) software package developed at the Jet Propulsion Laboratory (JPL) for the Palomar adaptive optics instrument (PALAO). APRC utilizes the Modified Gerchberg-Saxton (MGS) wavefront sensing algorithm, also developed at JPL. The WCS delivers such excellent correction of the atmosphere that non-common path (NCP) wavefront errors not sensed by PALAO but present at the coronagraphic image plane begin to factor heavily as a limit to contrast. We have implemented the APRC program to reduce these NCP wavefront errors from 110 nm to 35 nm (rms) in the lab, and we have extended these exceptional results to targets on the sky for the first time, leading to a significant suppression of speckle noise. Consequently we now report a contrast level of very nearly 1x10(exp -4) at separations of 2 lambda/D before the data is post processed. We describe here the major components of our instrument, the work done to improve the NCP wavefront errors, and the ensuing excellent on sky results, including the detection of the three exoplanets orbiting the star HR8799.

mgs↗

Demonstration of Broadband Contrast at 1.2 Lambda/D for the EXCEDE Phase-Induced Amplitude Apodization Coronagraph

The proposed coronagraph instrument on the EXCEDE (EXoplanetary Circumstellar Environments and Disk Explorer) mission study uses a Phase-Induced Amplitude Apodization (PIAA) coronagraph architecture to enable high-contrast imaging of circumstellar debris disks and giant planets at angular separations as close in as the habitable zone of nearby host stars. We report on the experimental results obtained in the vacuum chamber at the Lockheed Martin Advanced Technology Center in 10 percent broadband light centered about 650 nanometers, with a median contrast of 1 x 10 (sup -5) between 1.2 and 2.0 lambda /D simultaneously with 3 x 10 (sup -7) contrast between 2 and 11 =D between 2 and 11 lambda/D for a single-sided dark hole using a deformable mirror (DM) upstream of the PIAA coronagraph. The results are stable and repeatable as demonstrated by three measurements runs with DM settings set from scratch and maintained on the best 90 percent out of the 1000 collected frames. We compare the reduced experimental data with simulation results from modeling observed experimental limits; performance is consistent with uncorrected low-order modes not estimated by the Low Order Wavefront Sensor (LOWFS). Modeled sensitivity to bandwidth and residual tip/tilt modes is well-matched to the experiment.

Wavefront control↗

Studies of the Effects of Control Bandwidth and Dark-Hole Size on the HCIT Contrast Performance

We have carried out both theoretical and experimental studies of the sensitivity of dark hole contrast to the control bandwidth and dark-hole dimensions in high-contrast broadband stellar coronagraphy. We have evaluated the performance of DM actuator solutions in the presence of occulting mask defects using one to five 2% -wide bands spanning a 10% bandpass. We have also investigated the dependence of the HCIT contrast performance on the size of dark -hole area including large dark holes formed at the Nyquist limit of the DM.

exoplanets↗

High-Contrast Coronagraph Performance in the Presence of DM Actuator Defects

Deformable Mirrors (DMs) are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Occasionally DM actuators or their associated cables or electronics fail, requiring a wavefront control algorithm to compensate for actuators that may be displaced from their neighbors by hundreds of nanometers. We have carried out experiments on our High-Contrast Imaging Testbed (HCIT) to study the impact of failed actuators in partial fulfillment of the Terrestrial Planet Finder Coronagraph optical model validation milestone. We show that the wavefront control algorithm adapts to several broken actuators and maintains dark-hole contrast in broadband light.

adaptive optics↗

Photoreversible Color-Switching Cu-Doped TiO2 Nanoparticles for High-Contrast Rewritable Printing

Light-printable rewritable paper that can be used multiple times has attracted extensive attention because of its potential benefits in reducing environmental pollution and energy consumption. Developing rewritable paper with high black-to-colorless contrast, lasting legibility, and a fast response is fascinating but challenging. Here, we integrate the redox chemistry of Cu2+ ions into photoreductive TiO2 nanoparticles to produce Cu-doped TiO2 nanoparticles capable of highly photoreversible switching between colorless and black with excellent contrast and color stability. Incorporating such nanoparticles into hydroxyethyl cellulose produces a rewritable paper with the same appearance as that of conventional paper. More importantly, it demonstrates great features promising for practical applications, including high black-to-colorless contrast, fast light-printing (<20 s), long legible time (>3 days), high reversibility (>50 cycles), high resolution (90 μm), and large scale (A4 size) applicability.

Wang, Wenshou↗

Vegetation Response to Rising CO 2 Amplifies Contrasts in Water Resources Between Global Wet and Dry Land Areas

Rising atmospheric CO 2 impacts on vegetation physiological processes can alter land feedbacks on precipitation and water resources, but understanding of regional differences in these changes is uncertain. We investigate the impact of rising CO 2 on land water resources for different wetness levels using four Earth system models. We find an overall tendency of runoff to increase across all wetness levels. However, runoff increases in wet regions are much larger than those in dry regions, especially in wet seasons. This substantial amplification of contrasts between wet and dry regions increases at 3% per 100 ppm increase in CO 2 relative to the historical period, reaching 18% for a quadrupling of CO 2 , quantified by a new wetting contrast index (WCI). Physiological effects suppress evapotranspiration more in wet than dry regions, which has a larger contribution than radiative forcing to the amplification of runoff contrast, reshaping the spatial distribution of future land water resources.

58 GEOSCIENCES↗

Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask

We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.

Qiao, Zhi (ORCID:0000000286285320)↗

Graphic contrastive learning analyses of discontinuous molecular dynamics simulations: Study of protein folding upon adsorption

A comprehensive understanding of the interfacial behaviors of biomolecules holds great significance in the development of biomaterials and biosensing technologies. In this work, we used discontinuous molecular dynamics (DMD) simulations and graphic contrastive learning analysis to study the adsorption of ubiquitin protein on a graphene surface. Our high-throughput DMD simulations can explore the whole protein adsorption process including the protein structural evolution with sufficient accuracy. Contrastive learning was employed to train a protein contact map feature extractor aiming at generating contact map feature vectors. Subsequently, these features were grouped using the k-means clustering algorithm to identify the protein structural transition stages throughout the adsorption process. The machine learning analysis can illustrate the dynamics of protein structural changes, including the pathway and the rate-limiting step. Our study indicated that the protein–graphene surface hydrophobic interactions and the π–π stacking were crucial to the seven-stage adsorption process. Upon adsorption, the secondary structure and tertiary structure of ubiquitin disintegrated. The unfolding stages obtained by contrastive learning-based algorithm were not only consistent with the detailed analyses of protein structures but also provided more hidden information about the transition states and pathway of protein adsorption process and structural dynamics. Our combination of efficient DMD simulations and machine learning analysis could be a valuable approach to studying the interfacial behaviors of biomolecules.

97 MATHEMATICS AND COMPUTING↗

Coarsening dynamics of ternary polymer solutions with mobility and viscosity contrasts

Using phase-field simulations, we investigate the bulk coarsening dynamics of ternary polymer solutions undergoing a glass transition for two models of phase separation: diffusion only and with hydrodynamics. The glass transition is incorporated in both models by imposing mobility and viscosity contrasts between the polymer-rich and polymer-poor phases of the evolving microstructure. For microstructures composed of polymer-poor clusters in a polymer-rich matrix, the mobility and viscosity contrasts significantly hinder coarsening, effectively leading to structural arrest. For microstructures composed of polymer-rich clusters in a polymer-poor matrix, the mobility and viscosity contrasts do not impede domain growth; rather, they change the transient concentration of the polymer-rich phase, altering the shape of the discrete domains. This effect introduces several complexities to the coarsening process, including percolation inversion of the polymer-rich and polymer-poor phases—a phenomenon normally attributed to viscoelastic phase separation.

Chemistry↗

Comparison of Shadowgraphy and X-Ray Phase Contrast Methods for Characterizing a DT Ice Layer in an Inertial Confinement Fusion Target

Shadowgraphy and x-ray phase contrast (XPC) imaging are two techniques that are used for characterizing the deuterium-tritium ice layer in Inertial Confinement Fusion targets. Each technique has limitations that affect how accurately they can characterize small crystalline defects and measure the ice-thickness non-uniformities that may be only a few micrometers in height. The concern is that shadowgraphy may be overly sensitive to the shape and depth of defects in the surface and insufficiently sensitive to the shape of longer-wavelength roughness, while x-ray phase contrast may be too insensitive to defects in the ice surface. Multiple ice layers with different thicknesses (40 to 63 μm), thickness uniformities (peak-valley variations that range from <2- to 12 μm), and crystal defects were analyzed using shadowgraphy and x-ray phase contrast techniques. The results from each method agree when the ice layer is uniformly thick and the crystal lacks defects. That agreement worsens as the number of defects in the surface of the ice layer increases and the roughness that is determined from a shadowgram image of the target’s limb is greater than can be justified by the number of defects that are seen in the target’s front and rear surfaces. The XPC technique is considerably less sensitive to surface defects, in part due to the poorer dynamic range and image resolution compared to shadowgraphy. Localized regions of the ice layer that are thicker or thinner than the average thickness of the layer are reported by shadowgraphy to be smaller in height and footprint (by up to 30%) than by XPC. As a result, the two techniques report different ice layer thicknesses that can vary by up to 10%. Shadowgraphy results from two caustics that trace different paths through the target, and, in theory, image the same ice-vapor surface (but reflect from either the vapor or ice side of the interface) did not consistently characterize the size or shape of ice features to be the same magnitude. Here, the XPC technique provides the best assessment of low-mode (l < 7) roughness in the ice layer. Shadowgraphy results using the strongest caustic is best for detecting the presence of grooves in the ice, though not for quantifying the size of them. If multiple grooves are present it is best to discard and reform the ice layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-sensitivity in vivo contrast for ultra-low field magnetic resonance imaging using superparamagnetic iron oxide nanoparticles

Magnetic resonance imaging (MRI) scanners operating at ultra-low magnetic fields (ULF; <10 mT) are uniquely positioned to reduce the cost and expand the clinical accessibility of MRI. A fundamental challenge for ULF MRI is obtaining high-contrast images without compromising acquisition sensitivity to the point that scan times become clinically unacceptable. Here, we demonstrate that the high magnetization of superparamagnetic iron oxide nanoparticles (SPIONs) at ULF makes possible relaxivity- and susceptibility-based effects unachievable with conventional contrast agents (CAs). We leverage these effects to acquire high-contrast images of SPIONs in a rat model with ULF MRI using short scan times. This work overcomes a key limitation of ULF MRI by enabling in vivo imaging of biocompatible CAs. These results open a new clinical translation pathway for ULF MRI and have broader implications for disease detection with low-field portable MRI scanners.

42 ENGINEERING↗

Temporal prepulse contrast degradation in high-intensity CPA lasers from anisotropy of amplifier gain media

Here, we present a study of the temporal pre-pulse contrast degradation of high focused intensity pulses produced in CPA laser systems due to imperfections in amplifier design, alignment of amplifier components, and crystal inhomogeneity. Using an extended cross-polarized imaging technique, we demonstrate the presence of multiple crystal domains inside Ti:sapphire slabs with ≈10 cm diameter. Furthermore, the results of our numerical calculations show that crystalline c-axis orientation inhomogeneity caused by these crystal domains can lead to generation of pre-pulses with relative contrast >10 -10 within several picoseconds before the main pulse. In a multiple-slab amplifier head configuration sometimes used in high repetition rate systems, the misalignment of the amplifier slabs crystalline c-axes with respect to each other can lead to the generation of pre-pulses with relative contrast as high as 10 -6 , depending on the magnitude of misalignment.

47 OTHER INSTRUMENTATION↗

Temporal contrast degradation from mid-spatial-frequency surface error on stretcher mirrors

Temporal contrast degradation due to mid-spatial-frequency error in chirped-pulse amplification stretcher optics is studied. Third-order cross-correlation measurements reveal a temporal peak that appears when using two different mirrors processed by magnetorheological finishing, despite an improvement in rms roughness compared to a third unprocessed mirror. Simulations based on measured power spectral density show how the actual impact on contrast is different from measurements using a typical bandwidth-limited third-order cross correlator. Furthermore, strategies are proposed to avoid this type of contrast degradation while exploiting computer numerically controlled polishing techniques for enhancement of surface figure and roughness.

47 OTHER INSTRUMENTATION↗

Simultaneous contrast improvement and temporal compression using divided-pulse nonlinear compression

We experimentally demonstrate how divided-pulse nonlinear compression can be used to improve the temporal contrast of a laser pulse train while simultaneously temporally compressing the pulses. We measure a contrast improvement of almost four orders of magnitude on a nanosecond time scale and temporally compress the pulses from 1.2 ps to 187 fs. The efficiency of our method is also competitive with other contrast improvement methods, with 72% efficiency measured for the main pulse. We expect the method will be useful in the continuing development of high-power, Yb regenerative amplifiers, which suffer from both significant prepulses and relatively long pulse durations.

47 OTHER INSTRUMENTATION↗

Amorphous silicon carbide high contrast gratings as highly efficient spectrally selective visible reflectors

We report spectrally selective visible wavelength reflectors using hydrogenated amorphous silicon carbide (a-SiC:H) as a high index contrast material. Beyond 610nm and through the near infrared spectrum, a-SiC:H exhibits very low loss and exhibits an wavelength averaged index of refraction of n = 3.1. Here we design, fabricate, and characterize such visible reflectors using a hexagonal array of a-SiC:H nanopillars as wavelength-selective mirrors with a stop-band of approximately 40 nm full-width at half maximum. The fabricated high contrast grating exhibits reflectivity R >94% at a resonance wavelength of 642nm with a single layer of a-SiC:H nanopillars. The resonance wavelength is tunable by adjusting the geometrical parameters of the a-SiC:H nanopillar array, and we observe a stop-band spectral center shift from 635 nm up to 642 nm. High contrast gratings formed from a-SiC:H nanopillars are a promising platform for various visible wavelength nanophotonics applications.

Bauser, Haley C.↗

AlSb as a material for high index contrast nanophotonics

High contrast materials, i.e., materials with a high refractive index and low optical loss, are of wide interest for nanophotonics and metasurface designs at optical and near infrared wavelengths. We explore aluminum antimonide (AlSb) as a high contrast nanophotonic material, using the design of high contrast gratings (HCGs) for low loss dielectric mirrors as an example. The high index of refraction and low absorption coefficient of AlSb in the visible wavelength range enable designs of HCGs that can be effectively optimized to form mirrors with 93.5% reflectivity at red visible wavelengths. We detail a co-sputtering synthesis method for AlSb films, and achieve our target high index of refraction of 3.5 for 635 nm light. We also find that the high sensitivity of AlSb oxidation requires specific handling procedures in developing deposition processes to yield a near zero absorption coefficient.

Bauser, Haley C.↗

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases↗

Contrast Matching Biopolymers: A SANS-Based Approach to Structural Characterization of Chitosan

Immobilizing enzymes in polysaccharide-based matrices has been shown to improve both their stability and their catalytic efficiency. Among available materials, chitosan was selected for its abundance, biocompatibility, and versatility in a range of applications. While the broader aim of this work is to study chitosan as a matrix for immobilizing carbonic anhydrase (CA) for CO₂ capture, this study focused on determining the contrast match point (CMP) of hydrogenated and deuterated chitosan in D₂O:H₂O mixtures to enable future structural investigations using small-angle neutron scattering (SANS). Previous work successfully synthesized deuterated chitosan from Rhizopus oryzae mycelia and assessed the degree of deuteration using Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance (NMR). Building on this foundation, the current study determined the CMPs of both H-chitosan and D-chitosan by performing SANS measurements across a range of D₂O:H₂O solvent contrasts. The extracted CMPs for both forms correlated well with their respective calculated scattering length densities (SLDs), validating the experimental approach. These results establish a critical reference for selective contrast matching in future SANS studies of carbonic anhydrase immobilized in chitosan matrices, enabling detailed structural analysis of enzyme–matrix interactions.

Kosgallana, Chathurika J [ORNL] (ORCID:00000002851↗