Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

WFIRST/AFTA coronograph contrast performance sensitivity studies: simulation versus experiment

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory, we have investigated through modeling and simulations the sensitivity of dark hole contrast in a Hybrid Lyot Coronagraph (HLC) for several error cases, including lateral and longitudinal translation errors of two deformable mirrors, DM1 and DM2, lateral and/or longitudinal translation errors of an occulting mask and a Lyot-Stop, clocking errors of DM1 and DM2, and the mismatch errors between the testbed and the model sensitivity matrices. We also investigated the effects of a control parameter, namely the actuator regularization factor, on the control efficiency and on the final contrast floor. We found several error cases which yield contrast results comparable to that observed on the HLC testbed. We present our findings in this paper.

Nemati, Bijan↗

Hybrid Lyot Coronagraph for WFIRST: High Contrast Testbed Demonstration in Flight-like Low Flux Environment

In order to validate required operation of the proposed Wide-Field InfraRed Survey Telescope (WFIRST) coronagraph instrument, we have built a testbed in Jet Propulsion Laboratory (JPL), which is analogous to the baseline WFIRST coronagraph instrument architecture. Since its birth in 2016, this testbed, named as Occulting Mask Coronagraph (OMC) testbed, has demonstrated several crucial technological milestones: Broadband high contrast demonstration in both Hybrid Lyot Coronagraph (HLC) and Shape Pupil Coronagraph (SPC) modes while the Low Order Wavefront Sensing and Control (LOWFS/C) subsystem senses and corrects the dynamic flight-like wavefront disturbances. In this paper, we present up-to-date progress of HLC mode demonstration in the OMC testbed. While injecting the flight-like low photon flux starlight with expected Line of Sight (LoS) and Wavefront Error (WFE) perturbation to the OMC testbed, we demonstrate generating high contrast dark hole images. We first study the expected photon flux in actual flight environment, and estimate detection noise and estimation accuracy of the complex electric field if the wavefront sensing algorithm is used based on the pair-wise difference imaging. Then, we introduce our improved scheme to mitigate this photon-starved flight-like low flux environment. As a result, we generate a dark hole that meets the WFIRST raw contrast requirements using the 2nd magnitude star light. We establish the key ideas, describe test setups, and demonstrate test results with data analysis.

Wilson, Daniel↗

Lessons for WFIRST CGI from Ground-Based High-Contrast Systems

The Coronagraph Instrument (CGI) for NASA’s Wide Field Infrared Survey Telescope (WFIRST) will constitute a dramatic step forward for high-contrast imaging, integral field spectroscopy, and polarimetry of exoplanets and circumstellar disks, aiming to improve upon the sensitivity of current ground-based direct imaging facilities by 2–3 orders of magnitude. Furthermore, CGI will serve as a pathfinder for future exo-Earth imaging and characterization missions by demonstrating wavefront control, coronagraphy, and spectral retrieval in a new contrast regime, and by validating instrument and telescope models at unprecedented levels of precision. To achieve this jump in performance, it is critical to draw on the experience of ground-based high-contrast facilities. We discuss several areas of relevant commonalities, including: wavefront control, post-processing of integral field unit data, and calibration and observing strategies.

Xuan, Wenhao↗

Laboratory Demonstration of High Contrast with the PIAACMC Coronagraph on an Obstructed and Segmented Aperture

Coronagraphs (together with starshades) are an important tool to directly image and characterize exoplanets, and enable the search for biomarkers in reflected light on potentially habitable worlds. Their performance and efficiency has steadily been improving over the past several decades, but has not yet reached performance limits. In particular, the expected exoplanet yield for missions such as the Astro2020-recommended “IR/O/UV Flagship” can still be improved by factors of at least 2-3, simply by continued improvements in coronagraph performance, before they plateau due to physics limits. One possible architecture that can enable at least a part of this improvement is the Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC). Itoffersthe advantages of high throughput, small inner working angle (IWA),and almost noloss inPSF sharpness, and natively supports obstructed and segmented apertures, which is essential to the Astro2020 “IR/O/UV Flagship”mission. Historically, key disadvantages of PIAA have been poor tolerance to stellar angular sizes and maturity, but latest designs and demonstrations have made significant strides in this respect.In this paper, we present the current status and overview of our program to mature the PIAACMC technology. We first review PIAACMC designs for LUVOIR-A and B, which resultedin improved expected yield of Exo-Earths relative tothe baselines for both mission concepts. In particular, for LUVOIR-B, the yield improves from 28 to 42due to improvedtolerance to stellar angular size in our design. The improvement in yield is marginal for LUVOIR-A, but our design enables detecting planets around smaller diameter stars (nearby K-dwarfs and/or farther FG stars). We also describe our modeling and vacuum demonstrationsfor the LUVOIR-A aperture(which is more challengingthan LUVOIR-B due to the central obstruction).The demonstration included a LUVOUR-A pupil mask, an on-axis PIAA set of 2 mirrors with central holes, a Boston Micromachines DM, a patterned CMC mask, Lyot stop, and supporting masks and optics. Demonstrations were conducted at JPL’s High Contrast Imaging Testbed (HCIT) using several characterization andwavefront control techniques (primarily standard EFC, several experimental techniques were attempted, as well as speckle nulling). So far, our results include 1.9e-8 raw contrast in 10% broadband light between 3.5 and 8 l/D; 4.1e-8 and 1.6e-9 coherent contrasts in monochromatic light between 2-4 and 4-8 l/D, respectively. We also present measurements and analysis of sensitivity to tip/tilt jitter and stellar angular size. Finally, we compare our test results to models, present an analysis of our limiting factors, and explorefuture prospectsfor improvement based on validated models.

Coronagraph↗

The Twin Decadal Survey Testbeds in the High Contrast Imaging Testbed facility at NASA’s Jet Propulsion Laboratory

Direct imaging of an Earth-like exoplanet will require future missions, such as the proposed HabEx or LUVOIR concepts, to achieve starlight suppression with planet/star contrast ratios on the order of 10−10 at angular separations <100 milliarcseconds in visible wavelengths. To facilitate the technology and algorithm development required to enable this ambitious scientific goal, NASA’s Exoplanet Exploration Program (ExEP) High Contrast Imaging Testbed (HCIT) facility at the Jet Propulsion Laboratory (JPL) recently commissioned the Decadal Survey Testbed (DST), a state-of-the-art, flexible, and extremely stable coronagraph testbed. This testbed integrates years of experience and lessons learned at HCIT and has now demonstrated contrast ratios as low as few times 10−10 in 10% bandwidth. Following the success of DST, the HCIT team has developed a companion testbed, the Decadal Survey Testbed 2 (DST2) that further implements lessons learned from DST, and will provide the HCIT with additional coronagraph testbed capacity and efficiency. Commissioning for DST2 is currently targeted for Fall 2021. Here we provide an update on the status of DST, and report on the design, performance modeling simulations, and status of integration and testing for DST2, highlighting updates to the design from the original DST.

Siegler, Nick↗

A New Integral Field Spectrograph for Broadband Coronagraph Demonstrations at the High Contrast Imaging Testbed Facility

An integral field spectrograph (IFS) camera may help fulfill the exoplanet characterization goals of a future Habitable Worlds Observatory. During the Nancy Grace Roman Space Telescope mission formulation phase, the Coronagraph Instrument Project established the laboratory performance baseline of a combined coronagraph and IFS system with the Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES; 1E-8 contrast over an 18% bandpass; 3--9 lambda/D bowtie-shaped control region). New laboratory demonstrations are needed to expand on this milestone in terms of contrast, bandpass, and field of view towards the requirements of a future mission capable of characterizing the atmospheres of Earth-like exoplanets. Here we present the design of a successor to PISCES that can observe a 20 lambda/D-diameter field of view with an instantaneous bandpass up to 30%, at a resolving power R > 70 at visible wavelengths. This instrument will interface with the existing coronagraph layout in the High Contrast Imaging Facility DST-2 vacuum chamber. The addition of a spectroscopic imaging camera at HCIT will benefit the wider coronagraph technology community by enabling other NASA-supported investigators to automatically obtain multi-wavelength measurements of speckles both inside and outside of their control region, and the instrument will support community-led demonstrations of high-order wavefront sensing and control techniques such as dark hole maintenance and linear dark field control.

coronagraph↗

Stereomotion speed perception is contrast dependent

The effect of contrast on the perception of stimulus speed for stereomotion and monocular lateral motion was investigated for successive matches in random-dot stimuli. The familiar 'Thompson effect'--that a reduction in contrast leads to a reduction in perceived speed--was found in similar proportions for both binocular images moving in depth, and for monocular images translating laterally. This result is consistent with the idea that the monocular motion system has a significant input to the stereomotion system, and dominates the speed percept for approaching motion.

Motion Perception/physiology↗

New imaging technology: measurement of myocardial perfusion by contrast echocardiography

Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

NASA Program Biomedical Research and Countermeasur↗

Wavefront Amplitude Variation of TPF's High Contrast Imaging Testbed: Modeling and Experiment

Knowledge of wavefront amplitude is as important as the knowledge of phase for a coronagraphic high contrast imaging system. Efforts have been made to understand various contributions of the amplitude variation in Terrestrial Planet Finder's (TPF) High Contrast Imaging Testbed (HCIT). Modeling of HCIT with as-built mirror surfaces has shown an amplitude variation of 1.3% due to the phase-amplitude mixing for the testbed's front-end optics. Experimental measurements on the testbed have shown the amplitude variation is about 2.5% with the testbed's illumination pattern has a major contribution as the low order amplitude variation.

coronagraph↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Rapid Assessment of Contrast Sensitivity with Mobile Touch-screens

The availability of low-cost high-quality touch-screen displays in modern mobile devices has created opportunities for new approaches to routine visual measurements. Here we describe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. We will demonstrate a prototype for Apple Computer's iPad-iPod-iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing,

mobile devices↗

Studies of the Effects of Actuator Errors on the HCIT/PIAA Contrast Performance

The High Contrast Imaging Testbed Phase Induced Amplitude Apodization (HCIT/PIAA) coronagraph system at JPL relies on an Electric-Field Conjugation (EFC) wavefront correction algorithm to obtain the required high contrast. This algorithm works with one deformable mirror (DM) to estimate the electric-field to be controlled, and with one or multiple DM's to create a "dark-hole" in the image plane. We have investigated the effects of DM actuator errors on the efficiency of the EFC algorithm. The structural design of the optical system as well as the parameters of various optical elements used in the analysis are drawn from those of the HCIT/PIAA system that have been and will be implemented with one or two DM's. The simulation takes into account the surface errors of various optical elements. In this paper, we report our findings in the case of narrowband wavelength light.

PIAA↗

The Moving Group Targets of the Seeds High-Contrast Imaging Survey of Exoplanets and Disks: Results and Observations from the First Three Years

We present results from the first three years of observations of moving group (MG) targets in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) high-contrast imaging survey of exoplanets and disks using the Subaru telescope. We achieve typical contrasts of (is) approximately10(exp 5) at 1" and (is) approximately 10(exp 6) beyond 2" around 63 proposed members of nearby kinematic MGs. We review each of the kinematic associations to which our targets belong, concluding that five, beta Pictoris ((is) approximately 20 Myr), AB Doradus ((is) approximately 100 Myr), Columba ((is) approximately 30 Myr), Tucana-Horogium ((is) approximately 30 Myr), and TW Hydrae ((is) approximately 10 Myr), are sufficiently well-defined to constrain the ages of individual targets. Somewhat less than half of our targets are high-probability members of one of these MGs. For all of our targets, we combine proposed MG membership with other age indicators where available, including Ca ii HK emission, X-ray activity, and rotation period, to produce a posterior probability distribution of age. SEEDS observations discovered a substellar companion to one of our targets, kappa And, a late B star. We do not detect any other substellar companions, but do find seven new close binary systems, of which one still needs to be confirmed. A detailed analysis of the statistics of this sample, and of the companion mass constraints given our age probability distributions and exoplanet cooling models, will be presented in a forthcoming paper.

SEEDS high-contrast imaging survey of exoplanets↗

A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

contrast sensitivity↗

The Maturing of High Contrast Imaging and Starlight Suppression Techniques for Future NASA Exoplanet Characterization Missions

Over 3000 exoplanets and hundreds of exoplanetary systems have been detected to date and we are now rapidly moving toward an era where the focus is shifting from detection to direct imaging and spectroscopic characterization of these new worlds and their atmospheres. NASA is currently studying several exoplanet characterization mission concepts for the 2020 Decadal Survey ranging from probe class to flagships. Detailed and comprehensive exoplanet characterization, particularly of exo-Earths, leading to assessment of habitability, or indeed detection of life, will require significant advances beyond the current state-of-the-art in high contrast imaging and starlight suppression techniques which utilize specially shaped precision optical elements to block the light from the parent star while controlling scattering and diffraction thus revealing and enabling spectroscopic study of the orbiting exoplanets in reflected light. In this paper we describe the two primary high contrast starlight suppression techniques currently being pursued by NASA: 1) coronagraphs (including several design variations) and 2) free-flying starshades. These techniques are rapidly moving from the technology development phase to the design and engineering phase and we discuss the prospects and projected performance for future exoplanet characterization missions utilizing these techniques coupled with large aperture telescopes in space.

high contrast↗

Maximum-Likelihood Parameter Estimation for High-Contrast Wavefront Sensing & Control

Stellar coronagraphs use closed-loop focal-plane wavefront sensing and control algorithms to create high-contrast dark zones suitable for imaging exoplanets and exozodiacal dust clouds around nearby stars. At present, the deepest contrast has been achieved using model-based algorithms, which use the predicted focal-plane influence of the coronagraph's deformable mirrors to drive diffracted starlight toward zero over time in an optimal control framework. However, model-based algorithms are susceptible to model mismatch, wherein a departure of the coronagraph's true optical characteristics from the model predictions causes reduced control loop performance. Here, we report on a technique for maximum-likelihood estimation of the wavefront control Jacobian matrix and noise statistics of the coronagraph focal-plane electric field from data acquired in situ during closed-loop wavefront control operations. By empirically tuning the Jacobian and noise properties in a statistically rigorous fashion, the maximum-likelihood approach mitigates model mismatch and recovers near-optimal control loop performance.

coronagraphy↗

Determination of Burgers vectors in close-packed metals using g.b = 2 contrast.

Reexamination of dislocation images giving double contrast in the electron microscope for g.b = 2 as a possible means for Burgers vector determinations. In fcc foils which have been cut parallel to an active slip plane, the g.b = 2 criterion provides a quick positive Burgers vector analysis which can be carried out during observation. The method is also applicable to basal dislocations in hcp. A comparison between calculated two-beam profiles and experimental images in aluminum is discussed, and several commonly observed characteristics of g.b = 2 contrast are described.

Kestenbach, H.-J.↗

Contrast elements in birefringent filters.

Calculations were made to determine the effects which contrast elements of various thicknesses have in Lyot filters. A filter which is significantly narrower than the line at which it is looking produces the best results. Therefore, if the filter is broad the addition of as thick an element as possible is desired. However, if the filter is already narrow, a contrast element whose thickness equals that of the second Lyot element will produce the best performance.

Schoolman, S. A.↗