A comparison of WEC control strategies

The operation of Wave Energy Converter (WEC) devices can pose many challenging problems to the Water Power Community. A key research question is how to significantly improve the performance of these WEC devices through improving the control system design. This report summarizes an effort to analyze and improve the performance of WEC through the design and implementation of control systems. Controllers were selected to span the WEC control design space with the aim of building a more comprehensive understanding of different controller capabilities and requirements. To design and evaluate these control strategies, a model scale test-bed WEC was designed for both numerical and experimental testing (see Section 1.1). Seven control strategies have been developed and applied on a numerical model of the selected WEC. This model is capable of performing at a range of levels, spanning from a fully-linear realization to varying levels of nonlinearity. The details of this model and its ongoing development are described in Section 1.2.

30 DIRECT ENERGY CONVERSION↗

Deploying advanced supervisory control strategies to small- and medium-sized commercial buildings: Case study and lessons learned

Deploying advanced supervisory control strategies (ASCSs) in small- and medium-sized commercial buildings (SMBs) is vital but faces two issues: (1) a lack of building control and communication infrastructure (BCCI) in SMBs and (2) the significant engineering efforts required to implement and configurate ASCSs. Despite hindering the large-scale adoption of ASCSs in SMBs, these issues have not been adequately explored in the literature, which tends to focus more on feasibility than scalability. This paper provides a comprehensive evaluation of these two issues through a case study of an occupied SMB in eastern Tennessee of the United States. Specifically, we design and implement a BCCI for the studied building with commercial off-the-shelf products to accommodate the needs for deploying ASCSs. Here, we then deploy two ASCSs—a rule-based setback control and a model predictive control (MPC)—with the BCCI and evaluate their performance throughout the summer of 2024. This study reveals that the main bottlenecks in establishing BCCIs for SMBs are the high initial cost (∼$56/m 2 ) and communication delays (up to 9 min). Additionally, the assessment of the two ASCSs indicates that the majority (∼75 %) of the engineering effort required for implementation and configuration is spent on model identification, debugging, and tuning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FOCAL Campaign I: Advanced Wind Turbine Control Strategies

Campaign I of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aims to generate a dataset enabling the validation of aerodynamic performance of a scaled turbine mounted on a rigid tower in a fixed condition. The turbine considered in the FOCAL testing campaigns is the IEA-Wind 15MW Reference Wind Turbine. This scaled model is capable of simulating advanced blade-pitch control strategies in a high-quality wind field. The turbine is fully instrumented to record a variety of parameters in real time such as structural loads and dynamics. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Constant wind and blade-pitch with varying rotor speeds LC 2.X - Constant wind and rotor speed with varying blade-pitch LC 3.X - Varying wind with active closed-loop control Detailed properties on the modeled system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaign I: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine. UMaine ASCC Report Number 23-40-1183. Details on the results of the verification and validation are found in the following reference: Mendoza, Nicole et al., "Verification and Validation of Model-Scale Turbine Performance and Control for the IEA Wind 15 MW Reference Wind Turbine," Energies, vol. 15, no. 20, 2022, https://doi.org/10.3390/en15207649.

17 WIND ENERGY↗

An adaptive model-free robotic force control strategy for hydrodynamic real-time hybrid simulation of floating offshore wind turbines

Real-time hybrid simulation (RTHS) - a cyber-physical testing approach - promises to enhance the simulation fidelity of the model-scale experiments used to prototype floating offshore wind turbines (FOWTs). In hydrodynamic RTHS (hydro-RTHS), actuators emulate aerodynamic forces on model-scale FOWT specimens subjected to physical waves in a hydrodynamic laboratory. Robotic arms are promising candidates for actuation in hydro-RTHS due to their compact multi-degree-of-freedom (DOF) capabilities. Unlike classical RTHS for seismic applications, which typically relies on displacement control, hydro-RTHS requires 6-DOF force control on newly designed floating prototypes in a model-scale setting, which presents significant challenges, including modeling uncertainties, directional asymmetry, configuration drift, bandwidth limitations, and time-varying delays. To mitigate these constraints without extensive pre-test calibration, this study proposes an adaptive model-free robotic force control strategy that combines task-space explicit force control with a secondary joint-space pose-keeping task. The Adaptive Feedforward Compensator (AFC) is integrated into the force control loop to compensate for time-varying delay. Experimental testing was conducted using a Franka Emika Panda robotic arm with a 1:50 scale FOWT specimen under operational wind and wave conditions. Results demonstrate stable and consistent 6-DOF force tracking. Effective delay compensation was observed, with low-frequency delay reductions ranging from 71.4% to 91.8% and improvements in low-frequency surge force tracking of 25.0% to 52.1%. This study enhances robotic actuation performance in hydro-RTHS and introduces a force control strategy that supports reliable robotic operation in uncertain floating environments. Future work will explore disturbance-observer mechanisms to further enhance wave rejection capabilities under extreme wind and wave conditions.

17 WIND ENERGY↗

Reliability of unstable periodic orbit based control strategies in biological systems

Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry of the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Control Strategy With Efficiency and Reliability Improvement for Offshore DC Microgrids

Offshore microgrids, due to their remote location and lack of external energy support, face significant challenges in wide-range load operation and maintenance. Consequently, efficiency and reliability are critical concerns for converters in offshore dc microgrids. This article presents an optimal control strategy aimed at enhancing both efficiency and reliability. A normalized nonlinear relationship between power loss and thermal stress of a paralleled converter is first established. Based on this, a dual-objective optimization function with an active weight function as well as a system overall performance index is established. The active weight function dynamically adjusts the control priority based on converter efficiency and switching device thermal stress. Then, the optimal power-sharing strategy is derived by the Lagrange multiplier method with the proposed optimal function. Additionally, to accommodate a wide load range, an optimal selection strategy for operating converter combinations is proposed, requiring only low-bandwidth communication. Experiment verification is given to validate the effectiveness of the proposed control strategy. The experiment results demonstrate that the proposed control strategy can improve the overall performance of offshore microgrids by optimizing efficiency and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Segment Decentralized Control Strategies for Renewables-Rich Microgrids in Extreme Conditions

Microgrids provide a promising approach to accommodating various distributed energy resources (DERs), while requiring significant communication infrastructures that may be affected by extreme conditions such as natural disasters and cyber-attacks. In this paper, a fully decentralized control strategy without the need for communication is proposed for islanded microgrids with high renewables penetration. First, special multi-segment power/frequency characteristic curves are designed, so that different DERs can be automatically coordinated in a prioritized manner such as renewables first to maintain power balance while DER frequencies are regulated at their reference values. Second, piecewise linear served load versus frequency models are designed to prioritize loads according to their significance, so that only noncritical loads will be curtailed as needed while critical loads are supplied without any interruptions during power deficiency. The proposed strategy can effectively deal with various normal and extreme system conditions including 100% renewables penetration, loads and renewables variations, power deficiencies requiring load curtailments, disconnection of existing DERs, connection of new DERs as well as network sectionalization and reconfiguration. As a result, the proposed control strategy is validated in the real-time digital simulator (RTDS) model of the IIT Campus Microgrid to demonstrate its effectiveness in enhancing the resiliency of renewables-rich microgrids in extreme conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Coordinated Control Strategy of a Battery Energy Storage System to Support a Wind Power Plant Providing Multi-Timescale Frequency Ancillary Services

With increasing penetrations of wind generation on electric grids, wind power plants (WPPs) are encouraged to provide frequency ancillary services (FAS); however, it is a challenge to ensure that variable wind generation can reliably provide these ancillary services. This paper proposes using a battery energy storage system (BESS) to ensure the WPPs' commitment to FAS. This method also focuses on reducing the BESS's size and extending its lifetime. In this paper, a state-machine-based coordinated control strategy is developed to utilize a BESS to support the obliged FAS of a WPP (including both primary and secondary frequency control). This method takes into account the operational constraints of the WPP (e.g., real-time reserve) and the BESS (e.g., state of charge [SOC], charge and discharge rate) to provide reliable FAS. Meanwhile, an adaptive SOC-feedback control is designed to maintain SOC at the optimal value as much as possible and thus reduce the size and extend the lifetime of the BESS. In conclusion, the effectiveness of the control strategy is validated with an innovative, multi-area, interconnected power system simulation platform that can mimic realistic power systems operation and control by simulating real-time economic dispatch, regulating reserve scheduling, multi-area automatic generation control, and generators' dynamic response.

25 ENERGY STORAGE↗

A Station-hybrid HVDC System Structure and Control Strategies for Cross-seam Power Transmission

Cross-seam high voltage DC (HVDC) transmission in the United States can provide an efficient and flexible bulk power delivery highway between the interconnections. Recent studies have shown significant economic benefits of cross-seam HVDC transmission systems by taking the advantages of load diversity, frequency response, renewable energy diversity, and energy arbitrage in the different interconnections. This paper introduces a station-hybrid system scheme for cross-seam interconnections. Here, the proposed station-hybrid system combines the advantages of line commutated converter (LCC) and voltage source converter (VSC) technologies, thus enabling reliable and flexible bidirectional power flows across the interconnections. Control strategies of the station-hybrid system are investigated with a focus on power flow reversal control under normal operation conditions and grid support control under emergency conditions. The feasibility and effectiveness of the proposed station-hybrid system and corresponding control strategies are verified by simulations in PSCAD/EMTDC.

Station-hybrid system↗

Closed‐loop hierarchical control strategies for connected and autonomous hybrid electric vehicles with random errors

This study presents a closed‐loop hierarchical control strategy for a group of connected and autonomous hybrid electric vehicles (HEVs) with the purpose of optimising fuel economy while guaranteeing traffic mobility and vehicle safety. In the hierarchical control architecture, a decentralised stochastic model predictive control (SMPC)‐based higher level controller incorporating signal phase and timing information is formulated to optimise the velocity profile of each vehicle, and an adaptive equivalent consumption minimisation strategy based lower level controller is employed for the energy management control of the HEVs. Creatively, random errors of the control variable are considered in the SMPC framework. The errors are discretised and modelled as a Markov process and the state transition matrix of the errors is generated randomly to capture the error transition dynamics. To solve the SMPC problem more efficiently, a scenario‐based SMPC is employed. Moreover, the propulsion and recuperation efficiencies of the lower level controller are calculated at each time step with measurable variables, and fed back to the higher level controller for velocity optimisation in next time step. Simulation results validate the control effectiveness and advantages of the proposed control architecture.

Qiu, Shaolin↗

Energy savings with outdoor temperature-based smart ventilation control strategies in advanced California homes

We simulated the energy performance of smart ventilation controls based on outdoor temperature in homes located in California climate regions, designed to comply with the 2016 Title 24, Part 6 California Energy Code prescriptive requirements. The smart controls shift ventilation rates in time, but ensure an annual occupant pollutant exposure equal to, or less than, what would be experienced in a home with a constant ventilation rate equal to the whole house target airflow in the ASHRAE Standard 62.2-2016. Annual simulations of previously developed prototype homes with validated ventilation models were conducted via co-simulation of EnergyPlus with CONTAM. Controller performance varied substantially by climate zone, airtightness and house prototype. Smart controls were generally ineffective in Climate Zone 1 (Arcata) due to its lack of a cooling season and low diurnal temperature swings. The most successful smart controls used parameters pre-calculated using an optimization routine. In order to better inform state energy policy, we also determined savings weighted by the amount of new home construction in each climate. The best controls averaged about one-third of ventilation-related energy savings that increased to about 48–55% when weighted. Annual average savings were about 650–700 kWh/year for the best controllers. The vast majority of site energy savings were for heating end-uses (>90% of total savings). Whole house ventilation rates increased between 0% and 42%, with typical increases in the 15–20% range. Finally, the best-performing control strategies shifted ventilation rates seasonally and modulated flows within each season. Peak concentrations during low ventilation times were kept below an exposure level of 3, well below the maximum of 5 required to avoid acute exposure issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparative Assessment of Economic Model Predictive Control Strategies for Fuel Economy Optimization of Heavy-Duty Trucks

This paper provides a comparative assessment of three control strategies that fuse a global, offline dynamic programming (DP) optimization with online model predictive control (MPC) in an effort to minimize fuel consumption for a heavy-duty truck. The online MPC optimization, which is local in nature, makes refinements to a coarsely (but globally, subject to grid resolution) optimized target velocity profile from the DP optimization. Three candidate economic MPC formulations are evaluated: a time-based formulation that directly penalizes predicted fuel consumption, a simplified time-based formulation that penalizes braking effort in place of fuel consumption, and a distance-based convex formulation that maintains a tradeoff between energy expenditure and tracking of the coarsely optimized velocity based on DP. The performance of each approach is presented for three representative route profiles, using a medium-fidelity proprietary Volvo model of the heavy-duty truck’s longitudinal dynamics. Results demonstrate 4-7% fuel economy improvement across all three formulations, when compared to a baseline strategy. Furthermore, we present a detailed analysis of energy usage by “type” (aerodynamic losses, braking losses, and comparison of brake-specific fuel consumption), under each candidate control approach.

33 ADVANCED PROPULSION SYSTEMS↗

Control strategies for a telerobot

One of the major issues impacting the utility of telerobotic systems for space is the development of effective control strategies. For near-term applications, telerobot control is likely to utilize teleoperation methodologies with integrated supervisory control capabilities to assist the operator. Two different approaches to telerobotic control are evaluated: bilateral force reflecting master controllers and proportional rate six degrees-of-freedom hand controllers. The controllers' performance of single manipulator arm tasks is compared. Simultaneous operation of both manipulator arms and complex multiaxis slave arm movements is investigated. Task times are significantly longer and fewer errors are committed with the hand controllers. The hand controllers are also rated significantly higher in cognitive and manual control workload on the two-arm task. The master controllers are rated significantly higher in physical workload. The implications of these findings for space teleoperations and higher levels of control are discussed.

Ohara, John↗

Adaptive control strategies for cooperative dual-arm manipulators

Three strategies for adaptive control of cooperative dual-arm robots are discussed. Implementation of these adaptive controllers does not require the use of complex mathematical models of the arm dynamics or knowledge of the arm dynamic parameters or load parameters. These strategies have simple structures, and are computationally fast for on-line implementation with high sampling rates. In all three cases, the coupling effects between the arms through the load are treated as disturbances which are rejected by the adaptive controllers while following desired commands in a common frame of reference. Simulation results demonstrate the usefulness of the controllers.

Seraji, H.↗