Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Image processing for improved eye-tracking accuracy

Video cameras provide a simple, noninvasive method for monitoring a subject's eye movements. An important concept is that of the resolution of the system, which is the smallest eye movement that can be reliably detected. While hardware systems are available that estimate direction of gaze in real-time from a video image of the pupil, such systems must limit image processing to attain real-time performance and are limited to a resolution of about 10 arc minutes. Two ways to improve resolution are discussed. The first is to improve the image processing algorithms that are used to derive an estimate. Off-line analysis of the data can improve resolution by at least one order of magnitude for images of the pupil. A second avenue by which to improve resolution is to increase the optical gain of the imaging setup (i.e., the amount of image motion produced by a given eye rotation). Ophthalmoscopic imaging of retinal blood vessels provides increased optical gain and improved immunity to small head movements but requires a highly sensitive camera. The large number of images involved in a typical experiment imposes great demands on the storage, handling, and processing of data. A major bottleneck had been the real-time digitization and storage of large amounts of video imagery, but recent developments in video compression hardware have made this problem tractable at a reasonable cost. Images of both the retina and the pupil can be analyzed successfully using a basic toolbox of image-processing routines (filtering, correlation, thresholding, etc.), which are, for the most part, well suited to implementation on vectorizing supercomputers.

NASA Discipline Space Human Factors↗

MicroMAPS CO Measurements over North America and Europe during Summer-Fall 2004

The MicroMAPS instrument is a nadir-viewing, gas filter-correlated radiometer which operating in the 4.67 micrometer fundamental band of carbon monoxide. Originally designed and built for a space mission, this CO remote sensor is being flown in support of satellite validation and science instrument demonstrations for potential UAV applications. The MicroMAPS instrument system, as flown on Proteus, was designed by a senior student design project in the Aerospace Engineering Department, Virginia Tech, in Blacksburg, VA. and then revised by Systems Engineers at NASA Langley. The final instrument system was integrated and tested at NASA LaRC, in partnership with Scaled Composites and Virginia Space Grant Consortium (VSGC). VSGC supervised the fabrication of the nacelle that houses the instrument system on the right rear tail boom of Proteus. Full system integration and flight testing was performed at Scaled Composites, in Mojave, in June 2004. Its successful performance enabled participation in four international science missions on Proteus: in 2004, INTEX -NA over eastern North America in July, ADRIEX over the Mediterranean region and EAQUATE over the United Kingdom region in September,and TWP-ICE over Darwin, Australia and the surrounding oceans in Jan-Feb 2006. These flights resulted in nearly 300 hours of data. In parallel with the engineering developments, theoretical radiative transfer models were developed specifically for the MicroMAPS instrument system at the University of Virginia, Mechanical Engineering Department by a combined undergraduate and graduate student team. With technical support from Resonance Ltd. in June 2005, the MicroMAPS instrument was calibrated for the conditions under which the Summer-Fall 2004 flights occurred. The analyses of the calibration data, combined with the theoretical radiative transfer models, provide the first data reduction for the science flights reported here. These early results and comparisons with profile data from the NASA DC-8, the coincident AIRS CO retrievals, and selected CO measurements from the MOZAIC program will be presented.

Connors, Vickie S.↗

Remote Measurement of Pollution - A 40-Year Langley Retrospective: Temperature and Gaseous Species - Part 1

The National Aeronautics and Space Administration (NASA) phased down its Apollo Moon Program after 1970 in favor of a partly reusable Space Shuttle vehicle that could be used to construct and supply a manned, Earth-orbiting Space Station. Applications programs were emphasized in response to the growing public concern about Earth's finite natural resources and the degradation of its environment. Shortly thereafter, a workshop was convened in Norfolk, Virginia, on Remote Measurement of Pollution (or RMOP), and its findings are in a NASA Special Publication (NASA SP-285). The three primary workshop panels and their chairmen were focused on trace gas species (Will Kellogg), atmospheric particulates or aerosols (Verner Suomi), and water pollution (Gifford Ewing). Many of the workshop participants were specialists in the techniques that might be employed for the regional to global-scale, remote measurements from an Earth-orbiting satellite. The findings and recommendations of the RMOP Report represent the genesis of and a blueprint for the satellite, atmospheric sensing programs within NASA for nearly two decades. This paper is a brief, 40-year retrospective of those instrument developments that were an outgrowth of the RMOP activity. Its focus is on satellite measurement capabilities for temperature and gaseous species that were demonstrated by atmospheric technologists at the Langley Research Center. Limb absorption by solar occultation, limb infrared radiometry, and gas filter correlation radiometry techniques provided significant science data, so they are emphasized in this review.

Remsberg, Ellis E.↗

Reaching for 20 Years with the IMERG Multi-Satellite Products

The latest releases of Global Precipitation Measurement (GPM) mission products cap five years of vigorous development cycle since the launch of the GPM Core Observatory, and these now provide datasets that are relatively homogeneous across the joint Tropical Rainfall Measuring Mission (TRMM) and GPM eras. Version 06 of the U.S. GPM team's Integrated Multi-satellitE Retrievals for GPM (IMERG) merged precipitation product enforces a consistent intercalibration for all precipitation products computed from individual satellites with the TRMM and GPM Core Observatory sensors as the TRMM- and GPM era calibrators, respectively, and incorporates monthly surface gauge data. The basic IMERG algorithm now features precipitation motion vectors (used to drive the Lagrangian interpolation, or "morphing") that arecomputed by tracking vertically integrated vapor fields analyzed in MERRA2 and GEOS5. This innovation provides globally complete coverage, expanding IMERG's coverage beyond the 60°N-S latitude band provided by IR-based vectors, although we continue to mask out precipitation over snowy/icy surfaces as unreliable. A second innovation is the Quality Index (QI) data field. The half-hourly QI is taken as the approximate Kalman Filter correlation computed in the morphing calculation.

Huffman, George J.↗

The effects of notch filters on the correlation properties of a PN signal

With wideband pseudo-noise (PN) communications systems, it is sometimes desirable to supplement the inherent interference rejection capabilities by adding notch filters to attenuate relatively narrowband interference. This correspondence presents an investigation of the effects of notch filters on the performance of PN correlation receivers. A theoretical analysis of the correlation drop due to filter distortion has been conducted and confirmed by experimentation. Additional measurements and analysis have established the trade-off between correlation drop and interference suppression as a function of interference bandwidth. A typical result is that by incurring a penalty of a 1-dB drop in correlation peak, interfering signals having bandwidths of 2 to 3% of the PN chip rate can be attenuated by 25 dB.

Sussman, S. M.↗

Ring artifact and Poisson noise attenuation via volumetric multiscale nonlocal collaborative filtering of spatially correlated noise

X-ray micro-tomography systems often suffer from high levels of noise. In particular, severe ring artifacts are common in reconstructed images, caused by defects in the detector, calibration errors, and fluctuations producing streak noise in the raw sinogram data. Furthermore, the projections commonly contain high levels of Poissonian noise arising from the photon-counting detector. This work presents a 3-D multiscale framework for streak attenuation through a purposely designed collaborative filtering of correlated noise in volumetric data. A distinct multiscale denoising step for attenuation of the Poissonian noise is further proposed. By utilizing the volumetric structure of the projection data, the proposed fully automatic procedure offers improved feature preservation compared with 2-D denoising and avoids artifacts which arise from individual filtering of sinograms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlation of Electric Field and Critical Design Parameters for Ferroelectric Tunable Microwave Filters

The correlation of electric field and critical design parameters such as the insertion loss, frequency ability return loss, and bandwidth of conductor/ferroelectric/dielectric microstrip tunable K-band microwave filters is discussed in this work. This work is based primarily on barium strontium titanate (BSTO) ferroelectric thin film based tunable microstrip filters for room temperature applications. Two new parameters which we believe will simplify the evaluation of ferroelectric thin films for tunable microwave filters, are defined. The first of these, called the sensitivity parameter, is defined as the incremental change in center frequency with incremental change in maximum applied electric field (EPEAK) in the filter. The other, the loss parameter, is defined as the incremental or decremental change in insertion loss of the filter with incremental change in maximum applied electric field. At room temperature, the Au/BSTO/LAO microstrip filters exhibited a sensitivity parameter value between 15 and 5 MHz/cm/kV. The loss parameter varied for different bias configurations used for electrically tuning the filter. The loss parameter varied from 0.05 to 0.01 dB/cm/kV at room temperature.

Subramanyam, Guru↗

Optical Correlator With Complex Holographic Filter

Experimental real-time optical correlator includes complex-valued holographic filter computed from one of two input scenes. Made more tolerant of errors in patterns to be recognized. Filter function essentially coded hologram computed by Burchhardt's method, in which complex value of each pixel of fast Fourier transform of image represented by three real, nonnegative numbers. In generating optical correlator according to method, phasor of each pixel in Fourier transform represented by intensities in three adjacent pixels.

Chao, Tien-Hsin↗

Design of optimal binary phase and amplitude filters for maximization of correlation peak sharpness

Current binary-phase filters used for optical correlation are usually assumed to have uniform amplitude transmission. Here, a new type of filter is studied, the binary-phase-and-amplitude filter. If binary phase values of 0 and pi are assumed, the amplitude transmittance values of this type of filter can be optimized to maximize the peak sharpness. For a polarization-encoded binary-phase filter this can be translated into optimization of the rotation angle of the output polarizer following the filter-spatial-light modulator. An analytic expression is presented for the optimum polarizer angle and thus for the optimum binary-phase-and-amplitude filter design.

Downie, John D.↗

Filtering with perfectly correlated measurement noise.

Examination of (radar) Doppler data which are formed by mi1ing the returning microwave signal with a replica of the transmitted signal, counting the cycles of the beat, and sampling the counter at evenly spaced intervals t sub i. It is shown that the amount of information which can be extracted from a set of data may be larger if the associated noise is perfectly correlated than if it is white, and that the use of the white noise assumption in the filter may result in the loss of some of this information.

Reasenberg, R.↗

Optimizing a continuously variable filter in a hybrid optical correlator

In contrast to binary filters, continuously variable optical filters offer an ability to conpensate for certain imperfections in the optics of a hybrid correlator. Arbitrary static phase errors are introduced into a model of a phase-only filtering hybrid correlator, and a method of discovering a correction for them simulated. By a recursive technique a first approximation to the impulse's matched filter is adjusted (allowed to relax) so as to produce successively more localized distribution of the output in the correlation plane. The method is motivated by the development of continuously-variable phase-only spatial light modulators, but it is applicable to amplitude modulators and -with appropriate modification -- to binary modulators as well. The technique is robust against the form of the system's departure from ideal behavior.

Juday, Richard D.↗

Ring artifact reduction via multiscale nonlocal collaborative filtering of spatially correlated noise

X-ray micro-tomography systems often suffer severe ring artifacts in reconstructed images. These artifacts are caused by defects in the detector, calibration errors, and fluctuations producing streak noise in the raw sinogram data. In this work, these streaks are modeled in the sinogram domain as additive stationary correlated noise upon logarithmic transformation. Based on this model, a streak removal procedure is proposed where the Block-Matching and 3-D (BM3D) filtering algorithm is applied across multiple scales, achieving state-of-the-art performance in both real and simulated data. Specifically, the proposed fully automatic procedure allows for attenuation of streak noise and the corresponding ring artifacts without creating major distortions common to other streak removal algorithms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bi-axial Strain Measurement of Woven-Webbing Inflatable Structures Using Digital Image Correlation with RGB Filtering

Crewed inflatable softgoods structures can significantly reduce launch volume for habitable pressure vessels. To ensure the operational safety of these structures, NASA has developed an extensive testing program to evaluate the structural capability on ground test articles. This paper will discuss a current challenge faced by test engineers evaluating the strain of large-scale inflatable space structures during ground testing. Namely, the difficulty that arises using monochrome digital image correlation (DIC) to evaluate bi-axial strain for woven-webbing restraint layers. This report provides insight into a novel method of photogrammetry using red-green-blue (RGB) filtering in conjunction with DIC to evaluate the strain in each direction on a test article experiencing bi-directional strain. To evaluate this concept, a uniaxial tensile test was performed that represented a biaxial woven architecture using orthogonally interfaced straps. The resulting analysis demonstrates promise for this novel approach for isolating a specific region and direction of strain, reducing the effects of straps not in the area of interest, while allowing for a larger region of analysis. Moreover, it was shown that the application of a white basecoat prior to applying photogrammetry patterns significantly reduced data loss while performing RGB filtered DIC.

inflatable↗

Separation of lithospheric, external, and core components of the south polar geomagnetic field at satellite altitudes

We present a new approach to producing scalar Magsat magnetic anomaly maps based on correlation coefficient filtering and the use of almost all of the available orbits. Our method differs from earlier techniques with respect to the following: (1) Passes are selected based on their variance properties rather than planetary indices such as Kp. (2) The core field model is least squares fit to individual passes and subsequently removed instead of substracting the model directly. This technique replaces band pass filtering or polynomial trend removal methods. (3) Each selected pass is sorted geographically and by local time, placed into one of four different altitude bands, and correlation coefficient filtered with the two adjacent passes. The filtering is the second step toward isolating the static lithospheric signal from the more dynamic external field signals. (4) Least squares collocation is used to grid the correlated passes; subsequently, the dawn and dusk maps are also correlation filtered providing another step toward removal of external fields. (5) The four resultant total field maps are continued to a common altitude and again correlation filtered for the static lithospheric anomalies. (6) The filtered results are then averaged together to provide a new total field map of the lithosphere south of 40 deg S latitude. Our total field map differs from previous efforts over the crustal blocks of West Antarctica. We obtained a positive anomaly over Edward VII Peninsula, extending into the Byrd subglacial basin and obtained a negative anomaly over the Ellsworth Mountains and parts of the Byrd subglacial basin. Also, a positive anomaly extending from the Ross Sea to offshore Wilkes Land is present in our map; however, this feature is absent in other maps. Positive anomalies marking the Weddell Sea in previous efforts are not present in our map. Prominent external field anomalies in the quadrant offshore of Wilkes Land are present in all previous efforts; however, these signatures are reduced in our total field map. This map significantly advances efforts for the identification and interpretation of magnetic anomalies of the south polar lithosphere.

Alsdorf, Douglas E.↗

FORTRAN programs to process Magsat data for lithospheric, external field, and residual core components

The FORTRAN programs supplied in this document provide a complete processing package for statistically extracting residual core, external field and lithospheric components in Magsat observations. To process the individual passes: (1) orbits are separated into dawn and dusk local times and by altitude, (2) passes are selected based on the variance of the magnetic field observations after a least-squares fit of the core field is removed from each pass over the study area, and (3) spatially adjacent passes are processed with a Fourier correlation coefficient filter to separate coherent and non-coherent features between neighboring tracks. In the second state of map processing: (1) data from the passes are normalized to a common altitude and gridded into dawn and dusk maps with least squares collocation, (2) dawn and dusk maps are correlated with a Fourier correlation efficient filter to separate coherent and non-coherent features; the coherent features are averaged to produce a total field grid, (3) total field grids from all altitudes are continued to a common altitude, correlation filtered for coherent anomaly features, and subsequently averaged to produce the final total field grid for the study region, and (4) the total field map is differentially reduced to the pole.

Alsdorf, Douglas E.↗