Search NASA⌕ Search

SEARCH · Search NASA

Results for “counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Circuit Counts Carbon Fibers

Carbon fibers are counted when they fall on high-voltage grid. An arc discharge vaporizes fiber and triggers timer. The equal-duration pulses from timer are integrated by operational amplifier, giving an output voltage that is proportional to the number of fibers incident after reset switch was opened. If two or more fibers arrive at grid simultaneously, they are vaporized one at a time; thus all of them are counted.

Yang, L. C.↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

Hartig, G. F.↗

Gain Instabilities in Photomultipliers: How Accurate are Photon Counting Measurements?

Experiments performed on five commercially available photomultiplier tubes indicate that gain instabilities can be an important source of error in photon counting measurements at the 1% level. It is shown that the error cannot be significantly reduced by standard differential measurement techniques. Analysis of time variations in the pulse height distribution is shown to be a sensitive diagnostic tool for the measurement of gain variations. Using this technique it is found that gain variations occur at counting rates as low as 100 Hz. It is argued that such errors will be present at some level in all tubes. Several calibrating schemes capable of reducing the error to below the 0.1% level are discussed.

Rosen, W. A.↗

The Resonant Count Diagram and Solar g Mode Oscillations

Evidence is provided to support the hypothesis that, because of the particular frequency separations of the solar g modes, resonant three-wave interactions stimulate only a selected few g modes. A resonant count diagram was obtained by plotting the total number of possible resonant three-wave interactions or a given beat frequency against the inverse of the beat frequency (the beat period), within a given frequency tolerance. The 1 = 1, 2, 3, 4 g modes calculated by Christensen-Dalsgaard, Gough and Morgan (1979) for a standard model of the Sun were used. The diagram has a significant peak at 160 minutes as well as other peaks at longer periods. The g modes that Delache and Scherrer (1983) tentatively identified from the Crimea-Stanford data were also plotted. These modes were found to correspond with the other peaks in the diagram. This coincidence between the observed g modes and the peaks in the resonant count diagram suggest that the observed g modes do owe their observability to resonant three-wave interactions.

Guenther, D. B.↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

Comparisons of monthly mean cosmic ray counting rates observes from worldwide network of neutron monitors

In order to examine the stability of neutron monitor observation, each of the monthly average counting rates of a neutron monitors is correlated to those of Kiel neutron monitor. The regression coefficients thus obtained are compared with the coupling coefficients of isotropic intensity radiation. The results of the comparisons for five year periods during 1963 to 1982, and for whole period are given. The variation spectrum with a single power law with an exponent of -0.75 up to 50 GV is not so unsatisfactory one. More than one half of the stations show correlations with the coefficient greater than 0.9. Some stations have shifted the level of mean counting rates by changing the instrumental characteristics which can be adjusted.

Ryu, J. Y.↗

Detection of large-scale alignment of Lick counts around Abell clusters

The possible tendency of galaxies to be distributed in an aligned fashion, on sheets or filaments, on scales greater than the Abell radius, has been tested by a variety of statistics. The subject remains controversial because the statistical tests have either not been sensitive to the alignment or capable of unambiguously signalling alignment in a general, clumpy distribution of galaxies. The present approach combines ideas of Bingelli (1982) and Fry and Peebles (1980) in an examination of the cross correlation of Lick counts relative to the preferred direction defined by the cluster. This can substantially reduce the noise, and it is suggested on this basis that alignment has been found on large scales for Lick galaxy counts and Abell cluster positions and their angles.

Argyres, P. C.↗

Studies of IRAS sources at high galactic latitudes. I - Source counts at /b/greater than 60 deg and evidence for a north-south anisotropy of cosmological significance

A study of the IRAS sky at b with an absolute value greater than 60 deg is conducted. Source counts at 12, 25, 60 and 100 microns are presented, and it is shown that emission from interstellar dust at 100 microns is localized to a few small areas of tathe galactic polar caps. At 12 and 25 microns, the sky is dominated by stars; at 60 and 100 microns, by galaxies. Comparison with the minisurvey source counts indicates the 12and 25-micron source denstiy is lower at the present latitude than at a latitude whereby the absolute value of b equals 10-40 deg. Due to the greatly reduced effects of emission from interstellar dust, the 100 micron survey reaches a factor 1.6 deeper in flux at the present latitude than the minisurvey. An anisotropy significant at the 4-sigma level was found between the north and south galactic polar caps at 60 and 100 microns, after exclusion of the Virgo cluster and of the few remaining areas significantly affected by interstellar-dust emission. It is suggested that this anisotropy represents a cosmologically significant anisotropy in the galaxy distribution. The scale of associated inhomogeneity is of the order of at least 100(50/H)Mpc.

Rowan-Robinson, M.↗

Photon counts from stellar occultation sources

The feasibility of using stars as radiation sources for Earth atmospheric occultation experiments is investigated. Exoatmospheric photon counts of the order of 10 to the 6th power photons/sq cm/sec are realized for the 15 visually brightest stars. Most photon counts appear to be marginally detectable unless photomultiplier or cascade detection devices can be used.

Buglia, James J.↗

Variability analysis in low count rate sources

A method, based on the chi-square statistics, is described for detecting pulselike time variability in low count rate sources observed with photon-counting instruments. This method can be used even in the presence of observational gaps, takes full advantage of the filtering effect due to binning with different bin sizes, and takes into account the arbitrariness introduced by the binning phase. The procedure developed to limit the dependence of the results on the binning phase and ensure statistically correct results is described along with the application of the proposed procedure to a model of a variable source. Monte Carlo simulations are used to show how the method can be used to derive the characteristic variability time scales and that the method is more sensitive than the nonparametric Kolmogorov-Smirnov test in detecting variability to a given confidence level.

Collura, A.↗

Analysis of counting errors in the phase/Doppler particle analyzer

NASA is investigating the application of the Phase Doppler measurement technique to provide improved drop sizing and liquid water content measurements in icing research. The magnitude of counting errors were analyzed because these errors contribute to inaccurate liquid water content measurements. The Phase Doppler Particle Analyzer counting errors due to data transfer losses and coincidence losses were analyzed for data input rates from 10 samples/sec to 70,000 samples/sec. Coincidence losses were calculated by determining the Poisson probability of having more than one event occurring during the droplet signal time. The magnitude of the coincidence loss can be determined, and for less than a 15 percent loss, corrections can be made. The data transfer losses were estimated for representative data transfer rates. With direct memory access enabled, data transfer losses are less than 5 percent for input rates below 2000 samples/sec. With direct memory access disabled losses exceeded 20 percent at a rate of 50 samples/sec preventing accurate number density or mass flux measurements. The data transfer losses of a new signal processor were analyzed and found to be less than 1 percent for rates under 65,000 samples/sec.

Oldenburg, John R.↗

Photon counting detectors for Fabry-Perot interferometers

Sealed channel plate photomultipliers with multiple discrete anodes for use as photon counting detectors in the image plane of Fabry-Perot interferometers are described. The influence of design and construction on performance of completed devices is discussed. Effects on spatial resolution, lifetime, and counting efficiency are described. It is shown that devices can be optimized for particular applications. The results should be generally applicable to resistive anode and wedge and strip anode types of sealed detectors.

Darlington, E. H.↗

Chi-squared and C statistic minimization for low count per bin data

Results are presented from a computer simulation comparing two statistical fitting techniques on data samples with large and small counts per bin; the results are then related specifically to X-ray astronomy. The Marquardt and Powell minimization techniques are compared by using both to minimize the chi-squared statistic. In addition, Cash's C statistic is applied, with Powell's method, and it is shown that the C statistic produces better fits in the low-count regime than chi-squared.

Nousek, John A.↗

Vacuum Chuck Holds Filter Pad For Counting Particles

Microscope-stage holder keeps filter pad flat to keep it in focus. Specimen holder is special vacuum chuck that applies suction through flat screen. Suction keeps filter pad flat against specimen holder while microscope stage moving to scan areas denoted by grid. In microscope system equipped with video camera, image-analyzing/particle-counting computer, and automatic focus, use of stage speeds count considerably by eliminating need to stop frequently for manual refocusing. Technician free to perform other tasks while computer controls translation of stage and takes count automatically.

Berry, Anthony↗

Martian crater counts on Elysium Mons

Without returned samples from the Martian surface, relative age chronologies and stratigraphic relationships provide the best information for determining the ages of geomorphic features and surface regions. Crater-size frequency distributions of six recently mapped geological units of Elysium Mons were measured to establish their relative ages. Most of the craters on Elysium Mons and the adjacent plains units are between 500 and 1000 meters in diameter. However, only craters 1 km in diameter or larger were used because of inadequate spatial resolution of some of the Viking images and to reduce probability of counting secondary craters. The six geologic units include all of the Elysium Mons construct and a portion of the plains units west of the volcano. The surface area of the units studied is approximately 128,000 sq km. Four of the geologic units were used to create crater distribution curves. There are no craters larger than 1 km within the Elysium Mons caldera. Craters that lacked raised rims, were irregularly shaped, or were arranged in a linear pattern were assumed to be endogenic in origin and not counted. A crater frequency distribution analysis is presented.

Mcbride, Kathleen↗

Evolving starburst galaxies, faint number counts, and the 2 keV background

Blue and 60 micron extragalactic number counts and redshift distributions are modeled using evolutionary models in which galaxies periodically undergo transient starburst events. Support is found for the hypothesis that the same starburst phenomenon is responsible for the excess source counts seen at both wavelengths, though observed at lower mean redshift in the far infrared than in the blue. The soft X-ray emission from these evolving starburst events is not likely to exceed the 2 keV background unless the evolutionary rate is greater than (1 + z)-cubed (luminosity or density evolution) and the redshift of galaxy formation is greater than about five.

Lonsdale, C.↗

Determination of confidence limits for experiments with low numbers of counts

Two different methods, classical and Bayesian, for determining confidence intervals involving Poisson-distributed data are compared. Particular consideration is given to cases where the number of counts observed is small and is comparable to the mean number of background counts. Reasons for preferring the Bayesian over the classical method are given. Tables of confidence limits calculated by the Bayesian method are provided for quick reference.

Kraft, Ralph P.↗