Search NASA⌕ Search

SEARCH · Search NASA

Results for “counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Field-Programmable Gate Array Implementation of a Single Photon-Counting Receive Modem

We present a field-programmable gate array (FPGA) implementation of a single photon-counting receive modem for a pulse position modulated signal. The modem is compliant with the Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard and is capable of a maximum data rate of 267 Mbps. The system is designed on a commercial off-the-shelf FPGA platform and utilizes superconducting nanowire single photon counting detectors, analog to digital converters (ADC s) to sample the detectors, and two FPGAs. Symbol timing recovery, photon counting, convolutional deinterleaving, and codeword synchronization areis performed in the first FPGA. The second FPGA performs iterative decoding on each codeword of the serially concatenated pulse position modulated (SCPPM) signal. A digital filter is included to compensate for timing jitter of the detector, and the decoder throughput can be modified adjusted through reconfigurable parallelization. The decoder also implements a resource-efficient, algorithmic polynomial interleaver and deinterleaver. Both FPGAs can be reconfigured to switch between pulse position modulation (PPM)-16 and PPM-32 with code rates 1/3, 1/2, and 2/3. In this paper, we describe the receiver architecture and FPGA implementation of the timing recovery loop and SCPPM decoder, FPGA utilization for the different modes, and receive modem characterization test results.

Field-programmable Gate Array↗

A Photon Counting Ground Receiver for Free-Space Optical Communications

The National Aeronautics and Space Administration is developing a photon counting ground receiver for free-space optical communications. The receiver consists of a fiber interconnect, superconducting nanowire single photon counting detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. This receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency standard, which is used in the low photon flux communications regime, including on the upcoming Optical Artemis-2 Orion communications demonstration. The receiver architecture is modular, can be scaled for data rate, and is designed with primarily commercial-off-the-shelf technology. Two fiber interconnect and detector architectures are being prototyped. The first uses a few-mode-fiber coupled to a 16-channel SNSPD array and the second architecture uses a photonic lantern coupled to 7 single-pixel SNSPDs. Photon counting, symbol timing recovery, demodulation and decoding is done using several FPGA cards. This presentation describes the unique features of the ground receiver, performance test results, and challenges with using commercial SNSPDs in free-space optical communications.

Jennifer N Downey↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Photon Counting Techniques for the Bandlimited Optical Channel

Two methods of estimating received photon counts given a realistic noisy and bandlimited optical channel are presented. The function of estimating photon counts is critical in any optical communications receiver. The purpose of this work is to compare two methods, neither of which is generically optimal, with realistic channels-for the purpose of assessing which is more appropriate for application in a hardware receiver given the current state-of-the art.

photons↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The SRG/eROSITA All-Sky Survey: Constraints on ultralight axion dark matter through galaxy cluster number counts

Ultralight axions are hypothetical scalar particles that influence the evolution of large-scale structures of the Universe. Depending on their mass, they can potentially be part of the dark matter component of the Universe as candidates commonly referred to as fuzzy dark matter. While strong constraints have been established for pure fuzzy dark matter models, the more general scenario where ultralight axions constitute only a fraction of the dark matter has been limited to only a few observational probes. In this work, we use the galaxy cluster number counts obtained from the first All-Sky Survey (eRASS1) of the SRG/eROSITA mission together with gravitational weak lensing data from the Dark Energy Survey, the Kilo-Degree Survey, and the Hyper Suprime-Cam to constrain the fraction of ultralight axions in the mass range 10 −32 eV to 10 −24 eV. We put upper bounds on the ultralight axion relic density Ω a in independent logarithmic axion mass bins by performing a full cosmological parameter inference. We find an exclusion region in the intermediate ultralight axion mass regime with the tightest bounds reported so far in the mass bins around m a = 10 −27 eV with Ω a < 0.0035 and m a = 10 −26 eV with Ω a < 0.0079; both are at a 95% confidence level. When combined with cosmic microwave background probes, these bounds are tightened to Ω a < 0.0030 in the m a = 10 −27 eV mass bin and Ω a < 0.0058 in the m a = 10 −26 eV mass bin, with both at a 95% confidence level. This is the first time that constraints on ultralight axions have been obtained using the growth of structure measured by galaxy cluster number counts. These results pave the way for large surveys, which can be utilized to obtain tight constraints on the mass and relic density of ultralight axions with better theoretical modeling of the abundance of halos.

cosmological parameters↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

Power counting to saturation

We present a description of saturation in small 𝑥 deep inelastic scattering from power counting in a top-down effective theory derived from quantum chromodynamics (QCD). A factorization formula isolates the universal physics of the nucleus at leading power in 𝑥. The onset of saturation is then understood as a breakdown in the expansion in an emergent power counting parameter, which is defined by the matrix element of a gauge invariant operator. We identify a new radiation mode, which enables us to extend previous literature by distinguishing the appearance of the saturation scale from the transition to nonlinear evolution.

Astronomy & Astrophysics↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Nuclear Material Mass Estimates from Neutron Singles Count Rate [Poster]

The objective of this research was to create an algorithm to provide an estimate of special nuclear material (SNM) mass using only neutron count rate data from a Radioisotope Identification Device (RIID), rather than using time-correlated data from a neutron multiplicity counter. To meet this objective neutron count rate measurements of a 252 Cf source were taken at varying distances with an ORTEC Detective X, FLIR Identifinder 2, and an ORTEC RADEAGLET-R. An algorithm was created to estimate mass of SNM utilizing the singles rate equation and the measured absolute efficiency curves.

FLIR↗

Galaxy Clustering with LSST: Effects of Number Count Bias from Blending

The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) will survey the southern sky to create the largest galaxy catalog to date, and its statistical power demands an improved understanding of systematic effects such as source overlaps, also known as blending. In this work we study how blending introduces a bias in the number counts of galaxies (instead of the flux and colors), and how it propagates into galaxy clustering statistics. We use the 300 deg 2 DC2 image simulation and its resulting galaxy catalog (LSST Dark Energy Science Collaboration et al. 2021) to carry out this study. We find that, for a LSST Year 1 (Y1)-like cosmological analyses, the number count bias due to blending leads to small but statistically significant differences in mean redshift measurements when comparing an observed sample to an unblended calibration sample. In the two-point correlation function, blending causes differences greater than 3σ on scales below approximately 10', but large scales are unaffected. We fit Ω m and linear galaxy bias in a Bayesian cosmological analysis and find that the recovered parameters from this limited area sample, with the LSST Y1 scale cuts, are largely unaffected by blending. Our main results hold when considering photometric redshift and a LSST Year 5 (Y5)-like sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Open-Source Data Analysis Tool for Spectral Small-Angle X-ray Scattering Using Spectroscopic Photon-Counting Detector

Spectral small-angle X-ray scattering (sSAXS) is a powerful technique for material characterization from thicker samples by capturing elastic X-ray scattering data in angle- and energy-dispersive modes at small angles. This approach is enabled by the use of a 2D spectroscopic photon-counting detector that provides energy and position information of scattered photons when a sample is irradiated by a polychromatic X-ray beam. Here, we describe an open-source tool with a graphical interface for analyzing sSAXS data obtained from a 2D spectroscopic photon-counting detector with a large number of energy bins. The tool takes system geometry parameters and raw detector data to output 1D scattering patterns and a 2D spatially-resolved scattering map in the energy range of interest. We validated these features using data from samples of caffeine powder with well-known scattering peaks. This open-source tool will facilitate sSAXS data analysis for various material characterization applications.

Chemistry↗

ORNLERASE - EPA COUNTS PER MINUTE CALCULATOR CONVERSION FACTORS

This database is used in the EPA's Superfund Counts Per Minute (CPM) Calculator (https://epa-cpm.ornl.gov/index.html). This database contains conversion factors used in the calculator that help users estimate the expected radiation detector reading, in counts per minute (CPM), corresponding to a measured radioactivity level reported in either pCi/cm² or pCi/g. Because surface contamination and volumetric contamination behave differently, the tool uses separate conversion processes, each based on Monte Carlo N-Particle (MCNP)–derived conversion factors. The CPM Calculator supports conversions for a range of common environmental media—including soil, steel, glass, drywall, concrete, and wood—to generate detector-ready CPM values. The primary goal of this tool is to enable more efficient, real-time field measurements, reducing reliance on laboratory analyses and ultimately saving both time and money during Superfund assessments.

Dolislager, Fred [ORNL] (ORCID:0009000325477921)↗

Improved sensor counts micrometeoroid penetrations

A sensor, consisting of a thin dual-capacitor assembly with an outer film of thermal-control material, is used to detect micrometeoroid particles. A coincidence counting circuit is used to count the penetrations.

Davison, E. H.↗

Direct measurement of carbon-14 in carbon dioxide by liquid scintillation counting

Liquid scintillation counting technique is applied to the direct measurement of carbon-14 in carbon dioxide. This method has high counting efficiency and eliminates many of the basic problems encountered with previous techniques. The technique can be used to achieve a percent substitution reaction and is of interest as an analytical technique.

Horrocks, D. L.↗