Search NASA⌕ Search

SEARCH · Search NASA

Results for “cross-talk”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

One-Dimensional Photonic Crystal Superprisms

Theoretical calculations indicate that it should be possible for one-dimensional (1D) photonic crystals (see figure) to exhibit giant dispersions known as the superprism effect. Previously, three-dimensional (3D) photonic crystal superprisms have demonstrated strong wavelength dispersion - about 500 times that of conventional prisms and diffraction gratings. Unlike diffraction gratings, superprisms do not exhibit zero-order transmission or higher-order diffraction, thereby eliminating cross-talk problems. However, the fabrication of these 3D photonic crystals requires complex electron-beam substrate patterning and multilayer thin-film sputtering processes. The proposed 1D superprism is much simpler in structural complexity and, therefore, easier to design and fabricate. Like their 3D counterparts, the 1D superprisms can exhibit giant dispersions over small spectral bands that can be tailored by judicious structure design and tuned by varying incident beam direction. Potential applications include miniature gas-sensing devices.

Ting, David↗

Algorithm for Training a Recurrent Multilayer Perceptron

An improved algorithm has been devised for training a recurrent multilayer perceptron (RMLP) for optimal performance in predicting the behavior of a complex, dynamic, and noisy system multiple time steps into the future. [An RMLP is a computational neural network with self-feedback and cross-talk (both delayed by one time step) among neurons in hidden layers]. Like other neural-network-training algorithms, this algorithm adjusts network biases and synaptic-connection weights according to a gradient-descent rule. The distinguishing feature of this algorithm is a combination of global feedback (the use of predictions as well as the current output value in computing the gradient at each time step) and recursiveness. The recursive aspect of the algorithm lies in the inclusion of the gradient of predictions at each time step with respect to the predictions at the preceding time step; this recursion enables the RMLP to learn the dynamics. It has been conjectured that carrying the recursion to even earlier time steps would enable the RMLP to represent a noisier, more complex system.

Parlos, Alexander G.↗

Results of MODIS Band-to-Band Registration Characterization Using On-Orbit Lunar Observations

Since launch, lunar observations have been made regularly by both Terra and Aqua MODIS and used for a number of sensor calibration and characterization related applications, including radiometric stability monitoring, spatial characterization, optical leak and electronic cross-talk characterization, and calibration inter-comparison. MODIS has 36 spectral bands with a total of 490 individual detectors. They are located on four focal plane assemblies (FPA). This paper focuses on the use of MODIS lunar observations to characterize its band-to-band registration (BBR). In addition to BBR, the approach developed by the MODIS Characterization Support Team (MCST) can be used to characterize MODIS detector-to-detector registration (DDR). Long-term BBR results developed from this approach are presented and compared with that derived from a unique on-board calibrator (OBC). Results show that on-orbit changes of BBR have been very small for both Terra and Aqua MODIS and this approach can be applied to other remote sensing instruments.

Xiong, Xiaoxiong↗

Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.

Porst, J.-P.↗

Low-Power Architecture for an Optical Life Gas Analyzer

Analog and digital electronic control architecture has been combined with an operating methodology for an optical trace gas sensor platform that allows very low power consumption while providing four independent gas measurements in essentially real time, as well as a user interface and digital data storage and output. The implemented design eliminates the cross-talk between the measurement channels while maximizing the sensitivity, selectivity, and dynamic range for each measured gas. The combination provides for battery operation on a simple camcorder battery for as long as eight hours. The custom, compact, rugged, self-contained design specifically targets applications of optical major constituent and trace gas detection for multiple gases using multiple lasers and photodetectors in an integrated package.

Pilgrim, Jeffrey↗

Pixels, Imagers and Related Fabrication Methods

Pixels, imagers and related fabrication methods are described. The described methods result in cross-talk reduction in imagers and related devices by generating depletion regions. The devices can also be used with electronic circuits for imaging applications.

Pain, Bedabrata↗

Pixels, Imagers and Related Fabrication Methods

Pixels, imagers and related fabrication methods are described. The described methods result in cross-talk reduction in imagers and related devices by generating depletion regions. The devices can also be used with electronic circuits for imaging applications.

Pain, Bedabrata↗

SSERVI Annual Report: Year 4

The SSERVI Central Office forms the organizational, administrative and collaborative hub for the domestic and international teams, and is responsible for advocacy and ensuring the long-term health and relevance of the Institute. SSERVI has increased the cross-talk between NASA’s space and human exploration programs, which is one of our primary goals. We bring multidisciplinary teams together to address fundamental and strategic questions pertinent to future human space exploration, and the results from that research are the primary products of the institute. The team and international partnership reports contain summaries of 2017 research accomplishments. Here we present the 2017 accomplishments by the SSERVI Central Office that focus on: 1) Supporting Our Teams, 2) Community Building, 3) Managing the Solar System Treks Portal (SSTP), and 4) Public Engagement.

Virtual Institute↗

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target

MODIS, whose openly-public data have been used for over two decades to monitor and address global issues, has 16 Thermal Emissive Bands (TEBs) with central wavelengths that range from 3.7 μm to 14.4 μm, and are calibrated on-orbit using observations from its on-board blackbody. In order to maintain MODIS’ rich, well-calibrated archive of multispectral imagery and data, Earth targets are regularly used to track its long-term stability, as well as the consistency between the two sensors onboard the Terra and Aqua satellites. Moreover, these scenes can be used to compare MODIS Earth view data over the complete scan-angle range and evaluate the on-orbit performance of the TEBs response-versus-scan-angle (RVS) over mission lifetime. This manuscript focuses on evaluating the MODIS TEBs Collection (C6.1) radiometric calibration stability for both instruments using an in situ ocean target as reference (hereafter referred to as in situ sea surface temperature (SST)). Furthermore, it will assess the calibration consistency between the MODIS sensors. Lastly, it will analyze the on-orbit RVS stability for Terra and Aqua MODIS. Only cloud-free, nighttime MODIS TEB retrievals were used for the study. A normalization methodology is applied to standardize the MODIS data to the in situ SST. Additionally, spectral corrections were derived between some of the Terra and Aqua MODIS TEBs by using a combination of the MODIS Atmospheric Profile product and MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. Results indicate that most MODIS TEBs exhibit mission-long trends of ±0.50 K – with Terra band 30 presenting the largest downward drift due to residual electronic cross-talk effects. Moreover, the calibration consistency analysis over a warm ocean target demonstrated that the average Terra-to-Aqua MODIS bias for most bands is well within ±0.50 K (bands 27 and 30 show the largest - electronic crosstalk-related - biases). Lastly, the MODIS TEBs RVS trends display changes of ±0.50 K (except for bands 25 and 27 at the end-of-scan angles) for both instruments. Overall, the MODIS TEBs remain well-calibrated and their RVSs aptly-characterized.

MODIS↗

The MODIS TEBs Calibration and Look-up Table Delivery Process for Collections 6 and 6.1

MODIS is a cross-track, whisk-broom scanning imaging radiometer with a double-sided scan mirror that collects data in 36 spectral bands. Sixteen of the 36 MODIS spectral bands are Thermal Emissive Bands (TEBs) whose spectral wavelengths range from 3.5 μm to 14.4 μm. The TEB detectors are calibrated on a scan-by-scan basis using a quadratic calibration algorithm by observing both the MODIS on-board blackbody (BB) and a background space view reference. Blackbody warm-up/cool-down (WUCD) events are performed quarterly to track on-orbit changes associated with the TEB detectors' non-linearity. Following each WUCD, the calibration coefficients in the quadratic algorithm, and their associated contributions to the total uncertainty, are updated and delivered through separate look-up tables (LUTs) when all update criteria are met. Afterwards, the LUTs are incorporated into the Level 1B (L1B) product. Since the Terra MODIS mission began, a steady increase in electronic cross-talk has been observed for TEBs 27{30. Starting from Collection 6.1, an algorithm has been applied using correction coefficients derived from regularly-scheduled lunar observations, with the correction LUT update dependent on its impact on the current L1B product. The MODIS Characterization Support Team (MCST) has established a comprehensive set of procedures to assure timely and accurate LUT updates, and maintain the quality and accuracy of the L1B and science products. This paper provides an overview of the current calibration and LUT delivery process for the MODIS TEBs in Collections 6 and 6.1.

MODIS↗

Reduction of Raman Spectroscopy Data for H2-CO2-Air Tubular Flame Measurements

An approach of reducing spontaneous Raman spectroscopy data, based on the matrix inversion method which logically removes undesired sources of the Raman scattering signals including cross-talk due to the signals from other species, is discussed. The approach contains extensive calibration of temperature-dependent system response. The Raman spectra of several cold and hot calibration flames and their resulting calibration matrix are elaborated. The structure of H2-CO2-air tubular flames, in terms of major species (CO2, O2, N2, H2O, and H2) concentrations and temperature, was successfully measured with the optical technique. The Raman spectra data used in this study are taken from a uniquely designed experimental apparatus – a tubular burner and Raman spectroscopy system at Vanderbilt University. The characteristic uncertainties for chemical species are approximately ±2% by mole fraction for hot products and ±0.5% for room temperature reactants. The approach described here for hydrogen/air tubular flames may be adapted to hydrocarbon/air tubular flames when other necessary major species, for example, CH4 and CO for methane/air tubular flame, are considered in the whole process.

Raman Spectroscopy↗

Sidelobe Reduction and Mode-Purity Enhancement of Vortex Beams from a Programmable, Rectangular Phased Array Antenna

Tapering the magnitude of the electric field excitation of a programmable, rectangular phased array has been employed to achieve sidelobe reduction and enhancement of mode purity in vortex beams, which carry non-zero orbital angular momentum. Far-field radiation patterns pertaining to a commercial-off-the-shelf, 256-element antenna were generated via electromagnetic simulation. The patterns were decomposed into weighted sums of Laguerre-Gaussian modes. The extracted coupling coefficients were used to gauge mode purity. In comparison to a uniform excitation of the phased array elements, our studies indicate that employing a tapering technique can result in a 10.7 dB reduction of sidelobe power and a 7.22 dB improvement in worst-case, mode-to-mode cross-talk.

orbital angular momentum, phased array, beamformin↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Extreme Fast Charging: Effect of Positive Electrode Material on Crosstalk

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. We tested cells containing five positive electrode chemistries, LFP (olivine structure), LMO (spinel), LCO (layered), NMC811 (layered) and NCA (layered), using fast-charging protocols. After testing, the negative electrodes from cells containing positive electrodes crystallizing with a layered structure were found to have more lithium deposited on their surfaces. Further, those crystallizing with a layered structure also tended to have a larger increase in impedance than those crystallizing with a spinel or olivine structure. Characterization of the negative electrodes by X-ray photoelectron spectroscopy showed that using the concentrations of LiF and Li x PO y F z as metrics, the concentration of LiF in the SEI from the cell with different positive electrodes is LFP > LMO > LCO ~ NMC811 > NCA; and for Li x PO y F z , the order is LMO > LFP > NCA > NMC811 > LCO. Clearly, the positive-electrode material was influencing the amounts of these materials formed.

25 ENERGY STORAGE↗

Analysis of a macrophage carbamylated proteome reveals a function in post-translational modification crosstalk

Background. Lysine carbamylation is a biomarker of rheumatoid arthritis and kidney diseases. However, its cellular function is understudied due to the lack of tools for systematic analysis of this post-translational modification (PTM). Methods. We adapted a method to analyze carbamylated peptides by co-affinity purification with acetylated peptides based on the cross-reactivity of anti-acetyllysine antibodies. We also performed immobilized-metal affinity chromatography to enrich for phosphopeptides, which allowed us to obtain multi-PTM information from the same samples. Results. By testing the pipeline with RAW 264.7 macrophages treated with bacterial lipopolysaccharide, 7,299, 8,923 and 47,637 acetylated, carbamylated, and phosphorylated peptides were identified, respectively. Our analysis showed that carbamylation occurs on proteins from a variety of functions on sites with similar as well as distinct motifs compared to acetylation. To investigate possible PTM crosstalk, we integrated the carbamylation data with acetylation and phosphorylation data, leading to the identification 1,183 proteins that were modified by all 3 PTMs. Among these proteins, 54 had all 3 PTMs regulated by lipopolysaccharide and were enriched in immune signaling pathways, and in particular, the ubiquitin-proteasome pathway. We found that carbamylation of linear diubiquitin blocks the activity of the anti-inflammatory deubiquitinase OTULIN. Conclusions. Overall, our data show that anti-acetyllysine antibodies can be used for effective enrichment of carbamylated peptides. Moreover, carbamylation may play a role in PTM crosstalk with acetylation and phosphorylation, and that it is involved in regulating ubiquitination in vitro.

59 BASIC BIOLOGICAL SCIENCES↗

Crosstalk between p38, Hsp25 and Akt in spinal motor neurons after sciatic nerve injury

The p38 stress-activated protein kinase pathway is involved in regulation of phosphorylation of Hsp25, which in turn regulates actin filament dynamic in non-neuronal cells. We report that p38, Hsp25 and Akt signaling pathways were specifically activated in spinal motor neurons after sciatic nerve axotomy. The activation of the p38 kinase was required for induction of Hsp25 expression. Furthermore, Hsp25 formed a complex with Akt, a member of PI-3 kinase pathway that prevents neuronal cell death. Together, our observations implicate Hsp25 as a central player in a complex system of signaling that may both promote regeneration of nerve fibers and prevent neuronal cell death in the injured spinal cord.

NASA Discipline Developmental Biology↗