Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam optics design of a prototype 20 kW conduction-cooled SRF accelerator for medical sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

Saini, A. [Fermilab]↗

Beam Optics Design of A Prototype 20 kW Conduction-Cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Beam Optics Design of a Prototype 20 KW Conduction-cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Application of Accelerator Technology to Quantum Information Science

The intersection of accelerator and quantum information science (QIS) offers a unique platform to advance both fields through shared technology and infrastructure. This talk will discuss the synergies which exist between these two vastly different but complementary domains. We demonstrate how we leverage pre-existing infrastructure and knowledge to perform research and development which helps to realize dramatic improvements in both 10 km long accelerators and 10 cm large quantum processors. We will explore niobium superconducting radio-frequency (SRF) cavities, a highly advanced technology that excels in efficiently storing electromagnetic energy, enabling ultra-long photon lifetimes critical for quantum processors and facilitating the characterization of quantum materials with parts-per-billion precision. We will also discuss how advancements in superconducting materials, cryogenic systems, and control techniques help to reduce cost and improve performance for both quantum systems and particle accelerators. Moreover, we will discuss cross-disciplinary applications such as dark-matter searches and demonstrate the convergence of these fields in addressing fundamental scientific questions.

Bafia, Daniel [Fermilab]↗

Development of a Half-Meter Scale Traveling-Wave (TW) SRF Cavity

While a demonstration of TW resonance excitation in the 3-cell structure in 2K liquid helium had been prepared and carried out at Fermilab in collaboration with Euclid Techlabs, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab as the next step of TW development towards an accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing), Fermilab has proposed a half-meter scale TW RF design consisting of a 7-cell structure and a power feedback waveguide (WG) loop. The WG loop design includes the new RF configurations for TW resonance control during a high-power operation. 1-year US-Japan collaboration program focused on EBW optimization for the TW shape iris joint within the narrow gap was awarded and the efforts has been made by Fermilab, Jlab, and KEK. 1-year LDRD program of Fermilab is awarded recently to fabricate a low-cost mockup of the WG loop with new RF configurations and validate them. Here we will present a preliminary 7-cell TW RF design and will report the progress and challenges through the programs awarded.

43 PARTICLE ACCELERATORS↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of $\mathrm{HL-LHC AUP}$ Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profiles. A multi-probe, PCB-based rotating coil and a Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. Here this paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profile. A multi-probe, PCB-based rotating coil and Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. This paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

43 PARTICLE ACCELERATORS↗

Advances in understanding vacuum break dynamics in liquid helium-cooled tubes for accelerator beamline applications

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is essential for ensuring operational safety. This review summarizes experimental and theoretical work conducted in our cryogenics lab to address this issue. Systematic measurements were performed to study nitrogen gas propagation in uniform copper tubes cooled by both normal liquid helium (He I) and superfluid helium (He II). These experiments revealed a nearly exponential deceleration of the gas front, with stronger deceleration observed in He II-cooled tubes. To interpret these results, a one-dimensional (1D) theoretical model was developed, incorporating gas dynamics, heat transfer, and condensation mechanisms. The model successfully reproduced key experimental observations in the uniform tube system. However, recent experiments involving a bulky copper cavity designed to mimic the geometry of a superconducting radiofrequency (SRF) cavity revealed strong anisotropic flow patterns of nitrogen gas within the cavity, highlighting limitations in extrapolating results from simplified tube geometries to real accelerator beamlines. To address these complexities, we outline plans for systematic studies using tubes with multiple bulky cavities and the development of a two-dimensional (2D) model to simulate gas dynamics in these more intricate configurations. As a result, these efforts aim to provide a comprehensive understanding of vacuum breaks in particle accelerators and improve predictive capabilities for their operational safety.

Beamline tube↗

Rapid-cycling HTS magnet for muon acceleration

A very wide range of operational temperatures of the HTS (YBCO) superconductor makes it suitable for the construction of rapid-cycling magnets required for the muon acceleration. The measured [3] very low power loss of the 0.4 T magnet operating at 300 T/s suggested a realistic possibility of the HTS-based accelerator magnet with much higher magnetic field and ramp rate. The magnet core and the HTS cable designs for the 2 T field in the 30 mm beam gap are presented. The simulation of the HTS cable hysteresis power loss for the 1000 T/s ramp rate is discussed in terms of the operational temperatures and required cryogenic power.

43 PARTICLE ACCELERATORS↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗

Real-Time GPU-Accelerated OFDR With an Integrated Auxiliary Interferometer

A GPU-accelerated optical frequency domain reflectometry (OFDR) system with an improved integrated auxiliary interferometer is proposed. Unlike conventional approaches that require separate auxiliary interferometers and multiple detection channels, the proposed OFDR system embeds this functionality directly into the signal via an intentional beat component. This enables self-calibration of laser nonlinearity while maintaining a cost-effective hardware configuration. Building on this simplified configuration, the system leverages GPU acceleration with an NVIDIA RTX 4070 Ti to achieve real-time performance, delivering high-throughput signal processing for continuous OFDR interrogation. The signal processing pipeline comprises signal capture, resampling for nonlinearity compensation, and frequency shift computation, all optimized for parallel execution. Hardware benchmarking demonstrates substantial acceleration over CPU implementations, achieving up to a 45× speedup for resampling and frequency shift computations and enabling processing latencies below 30 ms. Thermal response validation is conducted under two complementary scenarios: localized heating using a water bath and cryogenic-temperature conditions using liquid nitrogen. Under localized heating, the system achieves an accuracy of 0.249 °C with a thermal sensitivity of 5.971 GHz/°C, while cryogenic-temperature validation demonstrates a frequency shift response with a sensitivity of 2.383 GHz/°C and an accuracy of 2.04 °C. The high acceleration of the proposed GPU-accelerated OFDR system and its accuracy are achieved by exploiting CUDA-based stride indexing, enabling efficient parallel segmentation and processing of large datasets without additional memory copies. The benchmarking results confirm the robustness, accuracy, and deployability of the proposed OFDR system across a wide temperature range, establishing it as a practical platform for real-time distributed fiber sensing in structurally dynamic environments.

Harb, Salah [Lawrence Berkeley National Laboratory↗

SuperKEKB beam final focus superconducting magnet system

The SuperKEKB was designed and constructed as the upgraded accelerator of KEKB. In this accelerator design, the nano-beam scheme of collision was applied and a luminosity of 8 x10 35 cm -2 s -1 was targeted. In the design, the beam final focus system was the key component in the accelerator hardware elements. This final focus system consists of 55 superconducting magnets. In this paper, the designs of the magnets, the cryostats and the cryogenic system are shown, and the field measurement results are reported. The SuperKEKB beam operation with the final focus system started on 2018 March 19, and the magnet quench events up to 2020 December 16 are described.

43 PARTICLE ACCELERATORS↗

Real time computations of cryogenic He properties

The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC and provide protons to the remainder of the existing accelerator complex. The new LINAC consists of a warm front end, 23 superconducting RF cryomodules, and a beam transfer line to the existing complex. The cryomodules (CMs) are to be tested at Fermilab's CryoModule Test Facility (CMTF).An important measurement in cryogenic testing is the heat load of each CM. Traditionally, at Fermilab, these measurements were made collecting archived data offline and analyzing it. The new control system for PIP-II is being developed with the EPICS (Experimental Physics and Industrial Control System) framework, which allows us to compute the heat load in real time using the HePak library.We are exploring other $He$ properties, such as flow, where flow meters are not available, which can also be calculated in real time and fed back to the cryogenics engineers.This paper details the real time heat load calculation and $He$ flow software developed for CM testing at CMTF, as well as the first results from the prototype HB650 CM. Future plans for 2-phase $LHe$ flow will also be outlined.

Hanlet, Pierrick [Fermilab]↗

High deuteron and neutron yields from the interaction of a petawatt laser with a cryogenic deuterium jet

A compact high-flux, short-pulse neutron source would have applications from nuclear astrophysics to cancer therapy. Laser-driven neutron sources can achieve fluxes much higher than spallation and reactor neutron sources by reducing the volume and time in which the neutron-producing reactions occur by orders of magnitude. We report progress towards an efficient laser-driven neutron source in experiments with a cryogenic deuterium jet on the Texas Petawatt laser. Neutrons were produced both by laser-accelerated multi-MeV deuterons colliding with Be and mixed metallic catchers and by d (d,n) 3 He fusion reactions within the jet. We observed deuteron yields of 10 13 /shot in quasi-Maxwellian distributions carrying ~8-10% of the input laser energy. We obtained neutron yields greater than 10 10 /shot and found indications of a deuteron-deuteron fusion neutron source with high peak flux (>10 22 cm -2 s -1 ). The estimated fusion neutron yield in our experiment is one order of magnitude higher than any previous laser-induced dd fusion reaction. Though many technical challenges will have to be overcome to convert this proof-of-principle experiment into a consistent ultra-high flux neutron source, the neutron fluxes achieved here suggest laser-driven neutron sources can support laboratory study of the rapid neutron-capture process, which is otherwise thought to occur only in astrophysical sites such as core-collapse supernova, and binary neutron star mergers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic field mapping of superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are the fundamental building blocks of modern particle accelerators. Niobium is the material of choice to build such cavities. These cavities require a cryogenic cool-down to ~2 ? 4 K for optimum performance minimizing RF losses on the inner cavity surface. However, temperature-independent residual losses in SRF cavities cannot be prevented entirely. One of the major sources of residual losses is trapped magnetic flux. The flux trapping mechanism depends on different factors, such as surface preparations and cool-down conditions. We have developed a diagnostic magnetic field scanning system (MFSS) using Hall probes and anisotropic magneto-resistance sensors to study the spatial distribution of trapped flux in 1.3 GHz single-cell cavities. The first result from this newly commissioned system revealed that the trapped flux on the cavity surface might redistribute with increasing RF power. The MFSS was also able to capture significant magnetic field enhancement at specific cavity locations after a quench.

Parajuli, Ishwari↗