Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigating the hydrolysis of cryogenically layered molybdenum hexafluoride through a disordered hydrogen-bonded network

Molybdenum hexafluoride (MoF6) is used as a non-radioactive substitute for uranium to study the hydrolysis of metal hexafluorides. Molybdenum hexafluoride gas and water vapor, from the air, were sequentially layered onto a diamond substrate kept at liquid nitrogen temperature using a custom designed cryogenic cell with a copper cold finger. Reaction progress was monitored by transmission Fourier Transform Infrared Spectroscopy (FTIR) through the layers and diamond substrate over several hours while allowing the substrate to warm. Changes in the modes in the 500–1000 cm -1 region are tracked as the reaction progresses in order to identify intermediate species. Strong absorption features are also observed in the 1000–3000 cm -1 range, suggesting the presence of ionic dissociation intermediates trapped in a disordered H-bonded network of cryogenic hydrofluoric acid. Here, a possible reaction pathway is proposed and the final hydrolysis product is characterized by FTIR, UV-vis, and scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Freeze range of a condensing gas propagating in a liquid helium-cooled tube

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is crucial for maintaining the operational safety of these facilities. Previous experimental investigations on nitrogen gas propagation in both normal liquid helium (He I) and superfluid helium (He II) cooled copper tubes unveiled a nearly exponential deceleration of the gas propagation. A comprehensive theoretical model incorporating gas dynamics, heat transfer, and condensation mechanisms has been developed, which effectively reproduces various key experimental observations. An intriguing phenomenon uncovered in our model simulation is that the gas propagation appears to nearly stop beyond a certain distance from the location where condensation starts. We refer to this distance as the freeze range. In this paper, we present our systematic study of the freeze range at various inlet mass fluxes and tube diameters. We show that the results can be well described by a simple correlation. The underlying physical mechanism that supports this useful correlation is explained. Knowing the freeze range may allow accelerator engineers to develop protocols for controlling frost-layer contamination in the beamline tubes, which is of great practical importance.

43 PARTICLE ACCELERATORS↗

Observation of nanoparticle coalescence during core-shell metallic nanowire growth in colloids via nanoscale imaging

The surface morphology and shape of crystalline nanowires significantly influence their functional properties, including phonon transport, electrocatalytic performance, to name but a few. However, the kinetic pathways driving these morphological changes remain underexplored due to challenges in real-space and real-time imaging at single-particle and atomic resolutions. This study investigates the dynamics of shell (Au, Pd, Pt, Fe, Cu, Ni) deposition on AuAg alloy seed nanowires during core-shell formation. By using chiral/non-chiral seed nanowires, advanced imaging techniques, including liquid-phase transmission electron microscopy (LPTEM), cryogenic TEM, and three-dimensional electron tomography, a three-step deposition process is revealed: heterogeneous nucleation, nanoparticle attachment, and coalescence. It is found that colloidal Ostwald ripening, metal reactivity, and deposition amount modulate nanoparticle size and surface roughness, shaping final morphologies. Noble metal nanoparticles (Au, Ag, Pd, Pt) coalesce with seed nanowire along the 〈111〉 direction, distinct from that of other metals. These findings are consistent across different metals, including Ru, Cu, Fe, and Ni, highlighting the hypothesis of these processes in nanowire formation. These findings enhance traditional crystallographic theories and provide a framework for designing nanowire morphology. Additionally, our imaging techniques may be applied to investigate phenomena like electrodeposition, dendrite growth in batteries, and membrane deformation.

Yang, Dahai↗

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silver(I) Supported Liquid Membranes for Selective Ethylene Recovery from Mixed-Gas Streams of Tandem CO 2 Electrolysis

Large-scale olefin separations from unreacted paraffins and other byproduct gases are primarily done by energy-intensive cryogenic distillation processes at refineries. Silver(I) supported liquid membranes (Ag SLMs) can be implemented at smaller production scales of ethylene (C 2 H 4 ), a critical industrial chemical, such as its electrocatalytic (EC) production from CO 2 . Challenges of EC C 2 H 4 production mainly stem from reducing gases like hydrogen (H 2 ), where the redox reactions pertinent to Ag(I) facilitators diminish olefin transport. Herein we report that aqueous Ag(I) solution in a composite Ag SLM can operate in mixed-gas conditions containing H 2 gas utilizing reduced titania compounds, such as titanium(III) oxide (Ti 2 O 3 ). Embedding Ti 2 O 3 in the polydimethylsiloxane layer of Ag SLM assisted in selectively separating C 2 H 4 from mixed-gas feed streams related to CO 2 electrolysis containing H 2 . The direct exposure of a mixed-gas stream containing C 2 H 4 , CO 2 , CO, N 2 , and CH 4 with as high as 50 vol % H 2 maintained excellent C 2 H 4 separations for 7 days of continuous operation. The Ag SLM provided effective separations of C 2 H 4 from CO (at detection limits), CH 4 (selectivity ratio (α) = 20–30), and H 2 (α = ∼20), but C 2 H 4 from CO 2 (α = 2–4) revealed a slightly lower separation. These data show that aqueous Ag(I) solution(s) used in the SLMs can separate C 2 H 4 for extended periods, even under highly reducing gas conditions. Also, we report C 2 H 4 recovery from the gas mixture produced in the EC CO 2 reduction process. In conclusion, the Ag SLM gave C 2 H 4 selective separation from a five-component complex mixed-gas stream, relevant to tandem CO 2 electrolysis.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Cryogenic EM Across Length Scales for Li Metal Anode Batteries

An interfacial understanding is necessary for developing strategies to commercialize high-energy density rechargeable lithium metal anode batteries, as currently, the lithium anode/electrolyte interface is unstable with prolonged cycling. We have used several strategies to improve the cycling performance of lithium metal anodes, including reducing the parasitic reactions between lithium metal and the electrolyte, and improving the electrodeposited lithium metal morphology. These strategies have generated unconclusive electrochemical data, that has required the need for nanoscale interfacial characterization of these solid-liquid interfaces. Our team has used the cryogenic transfer workflow developed by Leica in collaboration with cryo-SEM/FIB tools by Thermo Fisher Scientific to cross-section lithium metal anodes and intact coin cell batteries to observe the interfacial structures, lithium morphology, and failure mechanisms relative to changes in electrode contract pressure and electrolyte chemistry. Cross-sectional SEM images and EDS maps of the lithium metal anodes have provided a better understanding of the electrodeposited lithium morphology, quantity of 'dead' lithium metal, and quantity of solid electrolyte interphase material that has formed alongside the lithium metal. In understanding lithium metal battery failure at the system level, we used a cryogenic stage in a laser plasma FIB to cross-section through the coin cell's cap for imaging/mapping the entire battery stack under cryogenic conditions. The tools, methods, and results of these studies will be detailed in this presentation.

characterization↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Morphology Evolution in Self-Healing Liquid-Gallium-Based Mg-Ion Battery Anode

Conventional solid battery anodes suffer from dendrite growth and volume changes, resulting in poor cycling performances. Self-healing electrodes made of liquid metals and alloys can overcome these issues by reversibly undergoing liquid–solid phase transformations during (dis)charging. Just recently, we achieved 1000 cycles in Mg-ion battery anodes using liquid Ga as the active material, which reversibly transformed into solid Mg 2 Ga 5 during (de)magnesiation. However, the fundamental mechanism behind this liquid–solid phase transformation remains unclear. In this follow-up work, cryogenic focused ion beam electron microscopy is used to elucidate the morphology evolution when liquid Ga embedded in a carbon-binder matrix transforms into solid Mg 2 Ga 5 during cycling. We found that liquid Ga gradually diffuses into the surrounding matrix, increasing the contact area between active material and electrolyte, facilitating the charge transfer process. These new insights will help understand the performance of alkali- and alkaline-earth-metal batteries based on liquid anodes.

25 ENERGY STORAGE↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗

Cryogenic Electronics development for High Energy Physics

In the quest to study the fundamental nature of matterand the universe, High Energy Physics (HEP) experimentsoften operate in extreme conditions that lie well outside thestandard operating range of integrated circuits. Two prominentexamples of such extreme environments are the irradiationlevels experienced at high luminosity colliders, as well asoperation at cryogenic temperatures. Cryogenic electronicsis a broad term that encompasses circuits operating at temperatures below the standard operating limit (-55°C in the caseof military grade electronics), all the way down to millikelvin,as in the case of superconducting circuits. Cryogenic circuitshave a long history and have found applications in abroad spectrum of applications, such as infrared focal planearrays, PET, quantum science. While CMOS circuits have beenreliably operated at deep cryogenic temperatures (<4.2K),this article focuses on applications down to liquid Nitrogen(77K), and provides an overview on the design considerations,benefits, and unique challenges pertaining to cryogenic CMOSICs for large HEP experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Argonaut - A Robotic System for Cryogenic Environments

Fermilab and the HEP community invest significant resources into liquid argon detectors. The largest and most expensive of these detectors will be located in the Deep Underground Neutrino Experiment (DUNE). However, recent experiences have shown that there are limited avenues of monitoring, intervention, and interaction in the internal liquid environment. This proposal shows a technological path that could provide a valuable tool to ensure or at least improve the management of these HEP detectors. The development of a robotic system named Argonaut will demonstrate several technologies including 1) demonstration of suitable mobility of a small robotic device at liquid argon temperatures, 2) demonstration of wireless communication, 3) demonstration of improved diagnostics capabilities - such as tunable optics with motion control, 4) demonstration of interconnectivity of a robotic system with hardware residing within the detector. This initial research will be a seed for extended development in cold robotics and associated technologies. This work will allow FNAL to contribute a significant technology capability to recent efforts to cryogenic detector operations.

43 PARTICLE ACCELERATORS↗

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Hamamatsu VUV4 SiPM Performance for Liquid Argon Scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Here, using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7+1.1–2.4% and 17.2+1.6–3.0% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

Pershing, Teal↗

An electronic microemulsion phase emerging from a quantum crystal-to-liquid transition

Strongly interacting electronic systems often exhibit a complicated phase diagram that results from the competition between different quantum ground states. One feature of these phase diagrams is the emergence of microemulsion phases, where regions of different phases self-organize across multiple length scales. The experimental characterization of these microemulsions can pose considerable challenges, as the long-range Coulomb interaction microscopically mingles with the competing states. Here we observe the signatures of the microemulsion between an electronic Wigner crystal and an electron liquid in a MoSe 2 monolayer using cryogenic reflectance and magneto-optical spectroscopy. We find that the transition into this microemulsion state is marked by anomalies in exciton reflectance, spin susceptibility and umklapp scattering, establishing it as a distinct phase of electronic matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗