Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Instrumentation for in situ sampling and analysis of compounds of interest to Astrobiology in the lower atmosphere and surface of Titan

Instrumentation for exploration of the solar system will require new enabling technology for in situ sample acquisition and analysis of pre-biotic chemistry in extreme planetary environments, such as that encountered at the surface of Titan. The potential use of balloon aero-rovers for Titan places special emphasis on the importance of miniaturization, low power and low usage of consumables. To help meet this need, we are developing a miniature gas chromatograph coupled with a new Mini-Cell ion mobility spectrometer (GC-IMS), and one of us (PMH) has begun development work on a miniaturized cryogenic inlet system with sampling probes for Titan. This instrumentation, and its approach for meeting measurement needs for the analysis of prebiotic chemistry on Titan, will be discussed.

Holland, Paul M.↗

Study of the Thermal Physical Properties of Insulating Materials in A Titan Environment

Dragonfly is a planned rotorcraft mission that NASA/APL will be sending to Saturn’s moon Titan to study its chemistry. The Dragonfly Mass Spectrometer (DraMS) is a mass spectrometer that is being developed to identify different kinds of organic material that comprises Titan’s surface. The Cryogenic engineering team on DraMS is developing and interface between the room temperature rotorcraft body and the near-cryogenic temperatures of an onboard sample chamber, while minimizing the thermal leak to the Titan environment. As part of design process, the Cryogenic team has built a conductivity test rig for testing the thermophysical properties of candidate insulators, which includes Rohacell 31HF and hollowed 3D printed PEEK structures, at simulated Titan environmental conditions.

Thermal Conductivity↗

Modulating Electron Beam–Sample Interactions in Imaging and Diffraction Modes by Dose Fractionation with Low Dose Rates

Abstract Technological opportunities are explored to enhance detection schemes in transmission electron microscopy (TEM) that build on the detection of single-electron scattering events across the typical spectrum of interdisciplinary applications. They range from imaging with high spatiotemporal resolution to diffraction experiments at the window to quantum mechanics, where the wave-particle dualism of single electrons is evident. At the ultimate detection limit, where isolated electrons are delivered to interact with solids, we find that the beam current dominates damage processes instead of the deposited electron charge, which can be exploited to modify electron beam-induced sample alterations. The results are explained by assuming that all electron scattering are inelastic and include phonon excitation that can hardly be distinguished from elastic electron scattering. Consequently, a coherence length and a related coherence time exist that reflect the interaction of the electron with the sample and change linearly with energy loss. Phonon excitations are of small energy (<100 meV), but they occur frequently and scale with beam current in the irradiated area, which is why we can detect their contribution to beam-induced sample alterations and damage.

47 OTHER INSTRUMENTATION↗

Laboratory Electrical Conductivity of Marine Gas Hydrate

Methane hydrate was synthesized from pure water ice and flash frozen seawater, with varying amounts of sand or silt added. Electrical conductivity was determined by impedance spectroscopy, using equivalent circuit modeling to separate the effects of electrodes and to gain insight into conduction mechanisms. Silt and sand increase the conductivity of pure hydrate; we infer by contaminant NaCl contributing to conduction in hydrate, to values in agreement with resistivities observed in well logs through hydrate–saturated sediment. The addition of silt and sand lowers the conductivity of hydrate synthesized from seawater by an amount consistent with Archie's law. Here, all samples were characterized using cryogenic scanning electron microscopy and energy dispersive spectroscopy, which show good connectivity of salt and brine phases. Electrical conductivity measurements of pure hydrate and hydrate mixed with silt during pressure–induced dissociation support previous conclusions that sediment increases dissociation rate.

58 GEOSCIENCES↗

Characterizing Baselines and Change in Gas Hydrate Systems using EM Methods

The objective of this project was to advance our understanding of gas hydrate systems in nature by characterizing their electrical properties in the field and in the laboratory. In the laboratory measurements, methane hydrate was synthesized from pure water ice and flash frozen seawater, with varying amounts of sand or silt added. Electrical conductivity was determined by impedance spectroscopy, using equivalent circuit modeling to separate the effects of electrodes and to gain insight into conduction mechanisms. Silt and sand increase the conductivity of pure hydrate, inferred to be contaminant NaCl contributing to conduction in hydrate, to a peak conductivity in agreement with peak resistivities observed in well logs through massive hydrate (3,000--10,000 Ωm). The addition of silt and sand lowers the conductivity of hydrate synthesized from seawater, by an amount consistent with Archie's Law. All samples were characterized using cryogenic scanning electron microscopy and energy dispersive spectroscopy, which shows good connectivity of salt and brine phases. Electrical conductivity measurements of pure hydrate and hydrate mixed with silt during pressure-induced dissociation supports previous conclusions that sediment increases dissociation rate. In order to characterize gas hydrate systems in the field, we collected 360 line kilometers of controlled-source electromagnetic data on Walker Ridge 313, Orca Basin (WR100), Mad Dog (GC781), and Green Canyon 955 in the Gulf of Mexico, all areas with known or seismically inferred gas hydrate deposits and which have be drilled or targeted for future drilling. We deep-towed an EM transmitter that generates an alternating electric field which propagates through the seafloor geology. Data were recorded on 6 receivers towed behind the transmitter at distances between 550 and 1550 m. In the presence of conductive geology, the electric fields will be attenuated, and conversely, in resistive geology the fields will be preserved. Our data were inverted using a 2D inversion method that first optimizes the model-data misfit, then finds the smoothest model fitting the data. This ensures that resistivity structures present in the final model are likely necessary. At each of the proposed drilling sites we found increased resistivity, interpreted as increased hydrate concentrations. However, not only were the primary drilling sites not always more resistive than the alternate sites, at WR313 the strongest resistors were not at the locations targeted for drilling.

03 NATURAL GAS↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.

Kelliher, Warren C.↗

Vertical distribution of CH4 and N2O over the tropical site Hyderabad

Vertical distribution profiles of N2O and CH4 have been measured from Hyderabad, India using a balloon-borne cryogenic air sampler. The samples have been analyzed using gas chromatographic techniques. Results for two balloon flights made in 1987 and 1990 show effects of tropical characteristics like higher tropopause and upwelling motion due to Hadley circulation. These profiles also exhibit perturbations around 25 km height, which are likely to be due to dynamical effects. A comparison with the SAMS data show that the SAMS values for both these gases are higher by a factor of about 1.5 to 2 around 30 km height.

Lal, Shyam↗

Atmospheric measurements of carbonyl sulfide, dimethyl sulfide, and carbon disulfide using the electron capture sulfur detector

Measurements of atmospheric dimethyl sulfide (DMS), carbonyl sulfide (COS), and carbon disulfide (CS2) were conducted over the Atlantic Ocean on board the NASA Electra aircraft during the Chemical Instrumentation Test and Evaluation (CITE 3) project using the electron capture sulfur detector (ECD-S). The system employed cryogenic preconcentration of air samples, gas chromatographic separation, catalytic fluorination, and electron capture detection. Samples collected for DMS analysis were scrubbed of oxidants with NaOH impregnated glass fiber filters to preconcentration. The detection limits (DL) of the system for COS, DMS, and CS2 were 5, 5, and 2 ppt, respectively. COS concentrations ranged from 404 to 603 ppt with a mean of 489 ppt for measurements over the North Atlantic Ocean (31 deg N to 41 deg N), and from 395 to 437 ppt with a mean of 419 ppt for measurements over the Tropical Atlantic Ocean (11 deg S to 2 deg N). DMS concentrations in the lower marine boundary layer, below 600-m altitude, ranged from below DL to 150 ppt from flights over the North Atlantic, and from 9 to 104 ppt over the Tropical Atlantic. CS2 concentrations ranged from below DL to 29 ppt over the North Atlantic. Almost all CS2 measurements over the Tropical Atlantic were below DL.

Johnson, James E.↗

Mission Incredible: A Titan Sample Return Using In-Situ Propellants

An analysis of the use of in-situ volatile propellants for a sample return mission from Titan shows that this mission should be feasible. Such a mission would be invaluable for its science return, and its contribution to our understanding the origins of organic compounds in the solar system and our place in the universe.

Titan↗

Compact drilling and sample system

The Compact Drilling and Sample System (CDSS) was developed to drill into terrestrial, cometary, and asteroid material in a cryogenic, vacuum environment in order to acquire subsurface samples. Although drills were used by the Apollo astronauts some 20 years ago, this drill is a fraction of the mass and power and operates completely autonomously, able to drill, acquire, transport, dock, and release sample containers in science instruments. The CDSS has incorporated into its control system the ability to gather science data about the material being drilled by measuring drilling rate per force applied and torque. This drill will be able to optimize rotation and thrust in order to achieve the highest drilling rate possible in any given sample. The drill can be commanded to drill at a specified force, so that force imparted on the rover or lander is limited. This paper will discuss the cryo dc brush motors, carbide gears, cryogenic lubrication, quick-release interchangeable sampling drill bits, percussion drilling and the control system developed to achieve autonomous, cryogenic, vacuum, lightweight drilling.

Gillis-Smith, Greg R.↗

Recent Developments in the Curation of Cold, Volatile-Rich Extraterrestrial Samples

In recent years, the study of samples from cold, potentially volatile-rich Solar System bodies has increased dramatically. Returned samples from low- or cryogenic-temperature regions are highly sensitive to ambient temperatures, pressures, and materials. In order to maximize the scientific utility of such samples, they must be returned, handled, and stored under conditions that minimize sample alteration and contamination. The Johnson Space Center (JSC) Astromaterials Acquisition and Curation Office (hereafter called the Curation Office) is currently developing the ability to curate cold, volatile-rich samples; this abstract summarizes these efforts for Apollo lunar samples, organic-rich meteorites, comet samples, and lunar polar samples.

Mitchell, J. L.↗

An Experimental Study of Launch Vehicle Propellant Tank Fragmentation

In order to better understand launch vehicle abort environments, Bangham Engineering Inc. (BEi) built a test assembly that fails sample materials (steel and aluminum plates of various alloys and thicknesses) under quasi-realistic vehicle failure conditions. Samples are exposed to pressures similar to those expected in vehicle failure scenarios and filmed at high speed to increase understanding of complex fracture mechanics. After failure, the fragments of each test sample are collected, catalogued and reconstructed for further study. Post-test analysis shows that aluminum samples consistently produce fewer fragments than steel samples of similar thickness and at similar failure pressures. Video analysis shows that there are several failure 'patterns' that can be observed for all test samples based on configuration. Fragment velocities are also measured from high speed video data. Sample thickness and material are analyzed for trends in failure pressure. Testing is also done with cryogenic and noncryogenic liquid loading on the samples. It is determined that liquid loading and cryogenic temperatures can decrease material fragmentation for sub-flight thicknesses. A method is developed for capture and collection of fragments that is greater than 97 percent effective in recovering sample mass, addressing the generation of tiny fragments. Currently, samples tested do not match actual launch vehicle propellant tank material thicknesses because of size constraints on test assembly, but test findings are used to inform the design and build of another, larger test assembly with the purpose of testing actual vehicle flight materials that include structural components such as iso-grid and friction stir welds.

Richardson, Erin↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 - 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Hartwig, Jason↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Oxygen at Elevated Temperature

The purpose of this paper is to examine the key parameters that affect the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid oxygen at elevated pressures and temperatures. An in depth analysis of the effect of varying temperature, pressure, and pressurization gas on bubble point is presented. Testing of a 200 x 1400 and 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenics Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 92 to 130K and 0.138 - 1.79 MPa. Bubble point is shown to be a strong function of temperature with a secondary dependence on pressure. The pressure dependence is believed to be a function of the amount of evaporation and condensation occurring at the screen. Good agreement exists between data and theory for normally saturated liquid but the model generally under predicts the bubble point in subcooled liquid. Better correlation with the data is obtained by using the liquid temperature at the screen to determine surface tension of the fluid, as opposed to the bulk liquid temperature.

Hartwig, Jason↗

A scanning quantum cryogenic atom microscope at 6 K

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗