Search NASASearch

SEARCH · Search NASA

Results for “current limiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

Soltis, James V.

Dynamic array processing for computationally intensive expert systems in CLIPS

This paper puts forth an architecture for implementing a loop for advanced data structure of arrays in CLIPS. An attempt is made to use multi-field variables in such an architecture to process a set of data during the decision making cycle. Also, current limitations on the expert system shells are discussed in brief in this paper. The resulting architecture is designed to circumvent the current limitations set by the expert system shell and also by the operating environment. Such advanced data structures are needed for tightly coupling symbolic and numeric computation modules.

Athavale, N. N.

Arc discharge supply component protection circuitry

In a mercury-bombardment ion engine, the discharge supply is a high-current low-voltage one that maintains an arc or discharge inside the engine. In a 30-cm engine the supply provides up to 45 volts at about 13 amperes and is referenced at approximately 1100 volts above ground. Due to the engine discharge characteristics, a very slow feedback control loop is required. A high-speed current limit must be used to protect the components in the power conditioner, a pulse-width-modulated bridge inverter. A high-speed cycle-by-cycle current-limit circuit which allows the inverter to continue running in an overcurrent condition is used to protect it. The high-speed current sensing allows the inverter to be turned off each half cycle before the current in the primary of the inverter exceeds a safe level. This permits the inverter to continue to provide current into a discharge or a fault condition, until the feedback control system can actively control the current.

Ahrens, A. F.

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

cracking

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

cracking

Random Vibration Testing of Advanced Wet Tantalum Capacitors

Advanced wet tantalum capacitors allow for improved performance of power supply systems along with substantial reduction of size and weight of the systems that is especially beneficial for space electronics. Due to launch-related stresses, acceptance testing of all space systems includes random vibration test (RVT). However, many types of advanced wet tantalum capacitors cannot pass consistently RVT at conditions specified in MIL-PRF-39006, which impedes their use in space projects. This requires a closer look at the existing requirements, modes and mechanisms of failures, specifics of test conditions, and acceptance criteria. In this work, different lots of advanced wet tantalum capacitors from four manufacturers have been tested at step stress random vibration conditions while their currents were monitored before, during, and after the testing. It has been shown that the robustness of the parts and their reliability are mostly due to effective self-healing processes and limited current spiking or minor scintillations caused by RVT do not increase the risk of failures during operation. A simple model for scintillations events has been used to simulate current spiking during RVT and optimize test conditions. The significance of scintillations and possible effects of gas generation have been discussed and test acceptance criteria for limited current spiking have been suggested.

wet tantalum capacitors

Pathway to High Rate Capability in Interconnected Composite Electrolytes: A Case Study with a Single-Ion-Conducting Polymer

In a three-dimensional interconnected polymer/ceramic composite electrolyte (3D composite), both the polymer and ceramic electrolyte phases are individually connected with a polymer-rich surface layer to provide conformal contact with the electrodes. This work investigates how the transference number of the polymer phase affects the electrochemical properties of the 3D composite. Here, we fabricate a 3D composite using a “single-ion” conducting polymer electrolyte (PE), Li 1+x+y Al x Ti 2–x Si y P 3–y O 12 (LICGC) ceramic, and compare its electrochemical properties with the neat polymer, and with a 3D composite made with a dual-ion-conducting PE (we reported previously). Our results reveal that changing the polymer phase from a dual-ion-conducting PE to a single-ion-conducting PE results in a 9-fold increase in the limiting current density, although the interfacial impedance between the polymer and LICGC ceramic remains high (and contributes significantly to the total impedance of the 3D composite). Further, the limiting current density of the 3D composite is dictated by the PE and minimally affected by the ceramic scaffold. The ceramic scaffold, however, helps to ease the concentration gradient buildup within the PE and moderately improves the overall transference number. The LICGC scaffold does not provide any additional Li dendrite resistance due to its high reactivity with Li.

25 ENERGY STORAGE

Sea ice motions in the Central Arctic pack ice as inferred from AVHRR imagery

Synoptic observations of ice motion in the Arctic Basin are currently limited to those acquired by drifting buoys and, more recently, radar data from ERS-1. Buoys are not uniformly distributed throughout the Arctic, and SAR coverage is currently limited regionally and temporally due to the data volume, swath width, processing requirements, and power needs of the SAR. Additional ice-motion observations that can map ice responses simultaneously over large portions of the Arctic on daily to weekly time intervals are thus needed to augment the SAR and buoys data and to provide an intermediate-scale measure of ice drift suitable for climatological analyses and ice modeling. Principal objectives of this project were to: (1) demonstrate whether sufficient ice features and ice motion existed within the consolidated ice pack to permit motion tracking using AVHRR imagery; (2) determine the limits imposed on AVHRR mapping by cloud cover; and (3) test the applicability of AVHRR-derived motions in studies of ice-atmosphere interactions. Each of these main objectives was addressed. We conclude that AVHRR data, particularly when blended with other available observations, provide a valuable data set for studying sea ice processes. In a follow-on project, we are now extending this work to cover larger areas and to address science questions in more detail.

Emery, William

Development and performance of high-temperature superconducting CORC ® cables with CFD REBCO tapes

Abstract Increasing the normal zone propagation velocity (NZPV) in superconducting cables based on rare earth barium copper oxide (REBCO) tapes is expected to cause a paradigm shift by enabling the development of faster and more reliable quench detection systems to mitigate the development of destructive hot spots. Furthermore, a higher NZPV is beneficial in terms of fault current limitation capabilities by accelerating the homogenization of the quench in superconducting power devices. One way envisioned to increase the NZPV of cables based on REBCO tapes is the current flow diverter (CFD) concept. A Conductor on Round Core (CORC ® ) cable made with CFD REBCO tapes, called CFD CORC ® cable, and a CORC ® cable made with regular REBCO tapes, were fabricated and tested. The critical current of the CFD and regular CORC ® cables were obtained at temperatures ranging from 67 to 77 K in self-field. Measurements showed that the NZPV was increased by a factor of 4–4.5 in the case of the CFD CORC ® cable. Furthermore, the results suggest that the NZPV depends only on the applied current, similar to what has been observed previously on single REBCO tapes. These results demonstrate the successful integration of CFD REBCO tapes in CORC ® cables, without compromising their superconducting properties or their enhanced NZPV. The possibility of enhancing the NZPV of REBCO-based cables could facilitate quench detection, which remains an important issue in HTS magnet applications. This advancement also holds promise for the fault current limitation functionality of CORC ® cables.

Ben Saâd, Haïfa (ORCID:0000000216205364)

Current conduction in junction gate field effect transistors

The internal physical mechanism that governs the current conduction in junction-gate field effect transistors is studied. A numerical method of analyzing the devices with different length-to-width ratios and doping profiles is developed. This method takes into account the two dimensional character of the electric field and the field dependent mobility. Application of the method to various device models shows that the channel width and the carrier concentration in the conductive channel decrease with increasing drain-to-source voltage for conventional devices. It also shows larger differential drain conductances for shorter devices when the drift velocity is not saturated. The interaction of the source and the drain gives the carrier accumulation in the channel which leads to the space-charge-limited current flow. The important parameters for the space-charge-limited current flow are found to be the L/L sub DE ratio and the crossover voltage.

Kim, C.

Toward Optimization of Polymer Electrolytes by Electrochemical Characterization: Poly(pentyl malonate) versus Poly(ethylene oxide)

Ion transport in two polymer electrolytes, poly­(ethylene oxide) (PEO) and poly­(pentyl malonate) (PPM), mixed with lithium bis­(trifluoromethanesulfonyl)­imide (LiTFSI) is studied in the vicinity of the limiting current. The experimental measurements are in quantitative agreement with theoretical predictions based on the concentrated solution theory. The properties of two electrolytes are compared using a new plot wherein the length-normalized limiting current, i lim L, is plotted as a function of the length-normalized potential drop, Φlim/L, in symmetric cells with electrolyte thickness, L. We propose that electrolyte design should aim to obtain the largest values of i lim L and the smallest values of Φlim/L. Using this criterion, PPM/LiTFSI is a better polymer electrolyte than PEO/LiTFSI. We hope that PPM/LiTFSI will serve as a benchmark for developing next-generation polymer electrolytes.

Lee, Jaeyong

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY

Inrush Current Suppression Circuit and Method for Controlling When a Load May Be Fully Energized

A circuit and method for controlling when a load may be fully energized includes directing electrical current through a current limiting resistor that has a first terminal connected to a source terminal of a field effect transistor (FET), and a second terminal connected to a drain terminal of the FET. The gate voltage magnitude on a gate terminal of the FET is varied, whereby current flow through the FET is increased while current flow through the current limiting resistor is simultaneously decreased. A determination is made as to when the gate voltage magnitude on the gate terminal is equal to or exceeds a predetermined reference voltage magnitude, and the load is enabled to be fully energized when the gate voltage magnitude is equal to or exceeds the predetermined reference voltage magnitude.

Schwerman, Paul

In General, the Total Voltammetric Current from a Mixture of Redox-Active Substances will Not be the Sum of the Currents that Each Substance would Produce Independently at the Same Concentration as in the Mixture

At the potential range where both decamethylferrocene (dMeFc) and ferrocene (Fc) are oxidized with rates controlled by linear diffusion, electrogenerated Fc(+) radicals diffusing outwards from the electrode react quantitatively (K23 C=5.8 x 10(exp 8) with dMeFc diffusing towards the electrode and produce Fc and dMeFc. That reaction replaces dMeFc with Fc, whose diffusion coefficient is higher than that of dMeFc(+), and the total mass-transfer limited current from the mixture is increased by approximately 10%. Analogous observations are made when mass-transfer is controlled by convective-diffusion as in RDE voltammetry. Similar results have been obtained with another, and for all practical purposes randomly selected pair of redox-active substances, [Co(bipy)3](2+) and N - methylphenothiazine (MePTZ); reaction of MePTZ(+) with [Co(bipy)3](2+) replaces the latter with MePTZ, which diffuses faster and the current increases by approximately 20%. The experimental voltammograms have been simulated numerically and the role of (a) the rate constant of the homogeneous reaction; (b) the relative concentrations; and, (c) the diffusion coefficients of all species involved have been studied in detail. Importantly, it was also identified that within any given redox system the dependence of the mass-transfer limited current on the bulk concentrations of the redox-active species is expected to be non-linear. These findings are discussed in terms of their electroanalytical implications.

Leventis, Nicholas

Sputter coating of Nb₃Sn into SRF cavity using stoichiometric target

Nb₃Sn has emerged as a leading alternative material due to its higher superconducting critical temperature (Tc) and superheating field (Hsh), promising a viable solution to the intrinsic performance limit currently faced by Nb superconducting radiofrequency (SRF) cavities. We sputter-coated Nb₃Sn inside Nb SRF cavity using a stoichiometric Nb₃Sn tube target in a DC cylindrical magnetron sputter coater. The target was fabricated by growing an estimated >20 μm thick Nb₃Sn layer on a Nb tube via Sn vapor diffusion using Jefferson Lab’s coating system. Approximately 150 nm thick Nb-Sn films were sputter-deposited onto flat Nb samples at positions representing the beam tubes and equator of a 2.6 GHz Nb cavity. Post-deposition annealing at 950 °C for 3 h resulted in the formation of Nb₃Sn. Microstructural analysis of the annealed films was carried out to investigate the morphology and structure of the Nb₃Sn films. Later, a 2.6 GHz Nb SRF cavity was coated with a ~1.2 μm thick sputtered Nb-Sn film using a stoichiometric Nb₃Sn target, followed by annealing. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, indicating the formation of Nb₃Sn. After a light Sn recoating treatment, the cavity achieved a quality factor (Q0) of 6.7E+08 at lower field at 2.0 K.

Accelerator Physics

A Generalized Approach to Aircraft Trajectory Prediction via Supervised Deep Learning

As research advances diverse forms and missions of aircraft, the National Airspace System (NAS) will become increasingly crowded, limiting current communications resources to accommodate aviation operations. Ongoing research proposes a paradigm of airspace communications, such that resources are autonomously and dynamically allocated via intelligent agents; this allocation requires accurate representations of the NAS, including the predicted positions of aircraft. State-of-the-art research emphasizes the importance of a hybrid-recurrent framework for trajectory prediction and compares the impact of commonly considered weather data on prediction accuracy. However, current research has been limited in its scope of efforts, frequently utilizing a unique flight route, architecture, set of weather data, and date range. This article considers the challenges of generalizing hybrid-recurrent predictive models for flight trajectories. Results illustrate an increase in error variance when identical models are trained over a generalized set of flights; this may be mitigated with careful tuning of hyperparameters, both in the network structure and optimization algorithms. Even so, an irreducible vertical error was identified, resulting from the complex takeoff and landing procedures which can not be correlated to functions of weather or additional assumptions of aircraft behavior. Finally, the use of a test route indicates that generalized models still do not possess sufficient knowledge for general aircraft predictions, with mean error increases ranging from 70-500%. These results illustrate the need for continued efforts on improving model versatility, as well as potential limitations for spectrum allocation near airports and other centers.

Nathan Schimpf

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION