Techno-economic performance of reservoir thermal energy storage for data center cooling system
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
reVeal (the reV Extension for Analyzing Loads) is an open-source, flexible geospatial platform designed to characterize site suitability, with the goal of informing spatial downscaling and disaggregation of large-scale load projections.
Not Available
Digital twins are an excellent tool to model, visualize, and simulate complex systems, to understand and optimize their operation. In this work, we present the technical challenges of real-time visualization of a digital twin of the Frontier supercomputer.We show the initial prototype and current state of the twin and highlight technical design challenges of visualizing such a large High Performance Computing (HPC) system. The goal is to understand the use of augmented reality as a primary way to extract information and collaborate on digital twins of complex systems. This leverages the spatio-temporal aspect of a 3D representation of a digital twin, with the ability to view historical and real-time telemetry, triggering simulations of a system state and viewing the results, which can be augmented via dashboards for details. Finally, we discuss considerations and opportunities for augmented reality of digital twins of large-scale, parallel computers.
This software repository automates the deployment of a multi-vendor VXLAN-based BGP EVPN architecture, leveraging Containerlab to instantiate a stretched CLOS topology. It integrates Linux, Nokia SR Linux, and Arista cEOS, using BGP for underlay, overlay, and topology extension. The software enables rapid prototyping and testing of advanced network configurations. Its key advantage lies in providing a dynamic, programmable environment for research and development of critical technologies supporting dynamic workflows within supercomputing environments, surpassing the limitations of static, vendor-locked alternatives by fostering interoperability and agility.
Explore the source record for details and available documents.
We report the first O-band link with electrically reconfigurable intensity-modulation direct-detection (IMDD) and coherent operation using custom silicon photonic chips packaged with commercial electronic chips. Transmission below the KP4-FEC threshold is shown using commercial 53 Gbaud PAM4 digital signal processing (DSP) for 16QAM (200 Gbps/ λ ) and PAM4 (100 Gbps/ λ ). Efficient operation of the packaged full link at 12 and 11.2 pJ/bit is achieved for the PAM4 and 16QAM modes, respectively.
Water is a valuable resource that is all too often ignored when thinking about sustainability and High-Performance Computing (HPC). Los Alamos National Laboratory (LANL) found a solution to eliminate the amount of potable water usage needed for cooling HPC facilities. The Sanitary Effluent Reclamation Facility (SERF) was constructed in 2013 with the main purpose of removing silica from water in Los Alamos, New Mexico, to increase the cycles of concentration for the HPC Complex. SERF enabled Los Alamos National Laboratory to remove silica, reclaim effluent from the wastewater treatment plant and reduce the usage of potable water for HPC cooling.
The future of High Performance Computing (HPC) is carved out for all high-performance facilities. As computer processing increases exponentially, especially with the demand for AI training, more speed will equate to more computing density and ultimately more power draw and resource demand. Sandia National Laboratories has not seen or known of anything that would lead us to think this might change in the next 5 to 10 years.
This slide deck describes typical power systems of large datacenters along with reliability problems to bulk power systems from large-scale integration of datacenters. The slide deck covers the architecture of datacenter power systems, different power electronic converters used inside datacenters, their operation modes, and R&Dopportunities in maintaining grid stability.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The explosive growth in data collection and the need to process it efficiently, as well as the desire to automate increasingly complex tasks in transportation, medical care, manufacturing, security and many other fields have motivated a growing interest in neuromorphic computing. Unlike the binary, transistorbased ON/OFF logic gates and separate logic and memory functionalities employed in digital computing, neuromorphic computing is inspired by animal brains that use interconnected synapses and neurons to perform processing, storage and transmission of information at the same location, while only consuming ~20 W or less of power. Motivated by the brain’s efficiency, adaptability, self-learning and resiliency qualities, neuromorphic computing can be broadly defined as an approach to processing and storing information using hardware and algorithms inspired by models of biological neural systems. Present research in neuromorphic computing encompasses approaches that vary significantly in their degree of neuro-inspiration, from systems that only incorporate features such as asynchronous, event-driven operation or use crossbar arrays of non-volatile memory (NVM) elements to accelerate deep neural networks (DNNs), to designs that embrace the extreme parallelism, sparsity, reconfigurability, adaptability, complexity and stochasticity observed in nervous systems. The term ‘neuromorphic’ computing is often credited to Carver Mead, who in the 1980s investigated Si-based analog electronics to replicate functions of the animal retina. Earlier important advances in this field include the work of Frank Rosenblatt, who proposed the concept of the perceptron, Bernard Widrow, who used this concept to build one of the first analog neural networks, the Adaline and many other researchers (see ref. 6 for an historical perspective on neuromorphic computing). With the recent increase in the use of artificial intelligence and large language models, and rising concerns over the associated energy costs, interest in neuromorphic hardware has expanded rapidly. According to some estimates, driven largely by the drastic growth in the training use of artificial intelligence (AI) models using the current computing architectures, the energy cost of computing is projected to reach the energy supply worldwide by 2045. Furthermore, while this is not a realistic outcome, it means that, if more efficient computing technologies are not developed -- soon -- the world will soon become one where demand for energy and market constraints limit the continued increase of societal access to AI and cloud services from data centers. Data centers used for training and use of these models consume hundreds of terawatt hours of electricity, already past 4% of the US electricity demand.
Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness
The OR-SAGE tool is designed to use industry-accepted practices in screening sites and then employ the proper array of data sources through the considerable computational capabilities of GIS technology available at ORNL. The tool was developed to screen the potential for NPP siting on a national and regional basis. However, because of the tool granularity, it is often focused specifically on the immediate area around user sites of interest. If data center siting parameters can be added to OR-SAGE, the ability to evaluate data center siting on a localized scale will be beneficial.1 More than 60 data sets have been collected and processed by ORNL to develop exclusionary, avoidance, and suitability criteria for screening sites for a variety of power generation types, including nuclear power plants. Available site evaluation parameters include population density, slope, seismic activity, proximity to cooling-water sources, proximity to hazard facilities, avoidance of protected lands and floodplains, susceptibility to landslide hazards, and many others. All siting parameters should be considered as flags to inform siting decisions and should not be used to rule in or rule out any NPP site. Once data center siting parameters are identified, appropriate data sets will be collected and processed. The OR-SAGE process is very versatile. Essentially, OR-SAGE is a visual, relational database. The database partitions the contiguous United States, a total of 720 million hectares (~1.8 billion acres), into 100-m by 100-m (1 hectare or ~2.5 acre) cells. The database is tracking just under 700 million individual land cells. Successive suitability criterion is applied to each cell in the database. User-specified thresholds can be applied to each siting parameter data layer. In this manner, a variety of scenarios can be quickly and thoroughly evaluated. Data can be added and/or revised within OR-SAGE to address user interests. Siting security assessment capability is currently being added to OR-SAGE. Security is expected to be of concern at data centers whether it is collocated with a nuclear power generating technology or not. If data center is collocated with a nuclear power generating source, the security threat attractiveness level of both will likely increase. It will be of additional benefit if a potential data center site is also assessed for security vulnerability.