In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Performance Testing of the Astro-H Flight Model 3-Stage ADR

The Soft X-ray Spectrometer (SXS) is one of four instruments that will be flown on the Japanese Astro-H satellite, planned for launch in late 2015early 2016. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon micro calorimeters operated at 50 mK, cooled by an adiabatic demagnetization refrigerator (ADR). NASAGSFC is providing the detector array and ADR, and Sumitomo Heavy Industries, Inc. is providing the remainder of the cryogenic system (superfluid helium dewar (1.3 K), Stirling cryocoolers and a 4.5 K Joule-Thomson (JT) cryocooler). The ADR is unique in that it is designed to use both the liquid helium and the JT cryocooler as it heat sink. The flight detector and ADR assembly have successfully undergone vibration and performance testing at GSFC, and have now undergone initial performance testing with the flight dewar at Sumitomo Heavy Industries, Inc. in Japan. This presentation summarizes the performance of the flight ADR in both cryogen-based and cryogen-free operating modes.

adiabatic demagnetization refrigerator↗

Optimization Strategies for Single-Stage, Multi-Stage and Continuous ADRs

Adiabatic Demagnetization Refrigerators (ADR) have many advantages that are prompting a resurgence in their use in spaceflight and laboratory applications. They are solid-state coolers capable of very high efficiency and very wide operating range. However, their low energy storage density translates to larger mass for a given cooling capacity than is possible with other refrigeration techniques. The interplay between refrigerant mass and other parameters such as magnetic field and heat transfer points in multi-stage ADRs gives rise to a wide parameter space for optimization. This paper first presents optimization strategies for single ADR stages, focusing primarily on obtaining the largest cooling capacity per stage mass, then discusses the optimization of multi-stage and continuous ADRs in the context of the coordinated heat transfer that must occur between stages. The goal for the latter is usually to obtain the largest cooling power per mass or volume, but there can also be many secondary objectives, such as limiting instantaneous heat rejection rates and producing intermediate temperatures for cooling of other instrument components.

sub-kelvin cooling↗

Heat Switches for ADRs

Heat switches are key elements in the cyclic operation of Adiabatic Demagnetization Refrigerators (ADRs). Several of the types of heat switches that have been used for ADRs are described in this paper. Key elements in selection and design of these switches include not only ON/OFF switching ratio, but also method of actuation, size, weight, and structural soundness. Some of the trade-off are detailed in this paper.

adiabatic demagnetization refrigerator↗

Operation of an ADR Using Helium Exchange Gas as a Substitute for a Failed Heat Switch

The Soft X-ray Spectrometer (SXS) is one of four instruments on the Japanese Astro-H mission, which is currently planned for launch in late 2015. The SXS will perform imaging spectroscopy in the soft X-ray band (0.3-12 keV) using a 6 6 pixel array of microcalorimeters cooled to 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR) that rejects heat to either a superfluid helium tank (at 1.2 K) or to a 4.5 K Joule-Thomson (JT) cryocooler. Four gas-gap heat switches are used in the assembly to manage heat flow between the ADR stages and the heat sinks. The engineering model (EM) ADR was assembled and performance tested at NASA/GSFC in November 2011, and subsequently installed in the EM dewar at Sumitomo Heavy Industries, Japan. During the first cooldown in July 2012, a failure of the heat switch that linked the two colder stages of the ADR to the helium tank was observed. Operation of the ADR requires some mechanism for thermally linking the salt pills to the heat sink, and then thermally isolating them. With the failed heat switch unable to perform this function, an alternate plan was devised which used carefully controlled amounts of exchange gas in the dewar's guard vacuum to facilitate heat exchange. The process was successfully demonstrated in November 2012, allowing the ADR to cool the detectors to 50 mK for hold times in excess of 10 h. This paper describes the exchange-gas-assisted recycling process, and the strategies used to avoid helium contamination of the detectors at low temperature.

Adiabatic demagnetization↗

Operating Modes and Cooling Capabilities of the Flight ADR for the SXS Instrument on Astro-H

The microcalorimeter array on the Soft X-ray Spectrometer instrument on Astro-H requires cooling to 50 mK, which will be accomplished by a 3-stage adiabatic demagnetization refrigerator (ADR). The ADR is surrounded by a cryogenic system consisting of a superfluid helium tank, a 4.5 K Joule-Thomson (JT) cryocooler, and additional 2-stage Stirling cryocoolers that pre-cool the JT cooler and radiation shields within the cryostat. The unique ADR design allows the instrument to meet all of its science requirements using either the stored cryogen or the JT cryocooler as its heat sink, giving the instrument an unusual degree of tolerance for component failures or degradation in the cryogenic system. The flight detector assembly, ADR and dewar were integrated in early 2014, and have since been extensively characterized and calibrated. At present, the four instruments are being integrated with the spacecraft in preparation for an early 2016 launch. This presentation summarizes the operation and performance of the ADR in all of its operating modes.

adiabatic demagnetization refrigerator↗

Operating Modes and Cooling Capabilities of the 3-Stage ADR Developed for the Soft-X-Ray Spectrometer Instrument on Astro-H

A 3-stage adiabatic demagnetization refrigerator (ADR) is used on the Soft X-ray Spectrometer instrument on Astro-H to cool a 6x6 array of x-ray microcalorimeters to 50 mK. The ADR is supported by a cryogenic system consisting of a superfluid helium tank, a 4.5 K Joule-Thomson (JT) cryocooler, and additional 2-stage Stirling cryocoolers that pre-cool the JT cooler and cool radiation shields within the cryostat. The ADR is configured so that it can use either the liquid helium or the JT cryocooler as its heat sink, giving the instrument an unusual degree of tolerance for component failures or degradation in the cryogenic system. The flight detector assembly, ADR and dewar were integrated into the flight dewar in early 2014, and have since been extensively characterized and calibrated. This paper summarizes the operation and performance of the ADR in all of its operating modes

x-ray astronomy↗

ADR Design and Operation for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite 38 days after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called XARM. XARM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). For XARM, the spectrometer instrument named Resolve will be rebuilt to the original SXS design. It consists of a 6x6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage adiabatic demagnetization refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5 K Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XARM ADR and how it differs from the SXS version, and will briefly summarize on-orbit ADR performance during Hitomi's operational period.

adiabatic demagnetization refrigeration↗

3-Stage ADR for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite shortly after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). The spectrometer instrument, now named Resolve, will be similar to the original SXS design. It consists of a 6 by 6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage Adiabatic Demagnetization Refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5-degrees-Kelvin Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XRISM ADR and how it differs from the SXS version.

ADR (Adiabatic Demagnetization Refrigerator)↗

Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗

Paleomagnetic and rock-magnetic studies of the Permian Cutler and Elephant Canyon formations in Utah.

Study of the Permian Cutler formation and the upper 15 meters of the Permian Elephant Canyon formation at 0.6-meter stratigraphic intervals southwest of Moab in eastern Utah. The directions of natural remanent magnetization show a pronounced streak distribution, but thermal demagnetization successfully isolates the stable paleomagnetic direction. All directions are reversed, and no significant long-term change in pole position is observed throughout the entire section. The pole calculated from the Elephant Canyon data lies at 43.6 N, 119.6 E; the Cutler pole lies at 44.4 N, 116.2 E. Rock-magnetic analyses suggest that the secondary magnetization results from the iron hydroxides and was acquired after recent surface exposure.

Gose, W. A.↗

Magnetocaloric pump

Very cold liquids and gases such as helium, neon, and nitrogen can be pumped by using magnetocaloric effect. Adiabatic magnetization and demagnetization are used to alternately heat and cool slug of pumped fluid contained in closed chamber.

Brown, G. V.↗

Cause of secondary magnetization in lunar samples, part C

The unstable component of the magnetization found in lunar samples was investigated by returning a demagnetized tracer igneous rock sample from Apollo 12 to the moon on Apollo 16. After the return of the sample, the soft component was similar to the original soft component of the first trip. It is concluded that the soft component is an artifact of the trip.

Pearce, G. W.↗

Remanent magnetization of the lunar surface.

Two lines of evidence support each other in suggesting that a large volume of the rocks near the lunar surface possess a uniform remanent magnetization with an intensity of about .000002 emu/g. The first line is the discovery by several groups of investigators of weak but stable remanent magnetizations in igneous samples returned from the first four Apollo missions. Although the mechanism of acquisition of this remanence has not been definitely established, several lines of evidence, including thermal demagnetization, suggest that it is a thermoremanent magnetization (TRM) carried by iron. Many of the breccias are similarly magnetized. The second line is the measurement of significant fields at the Apollo sites and the discovery of large-scale anomalies by the sub-satellite magnetometer experiment.