Search NASA⌕ Search

SEARCH · Search NASA

Results for “demand side”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Progress toward Producing Demand-Response-Ready Appliances

This report summarizes several historical and ongoing efforts to make small electrical demand-side devices like home appliances more responsive to the dynamic needs of electric power grids. Whereas the utility community often reserves the word demand response for infrequent 2 to 6 hour curtailments that reduce total electrical system peak load, other beneficial responses and ancillary services that may be provided by responsive electrical demand are of interest. Historically, demand responses from the demand side have been obtained by applying external, retrofitted, controlled switches to existing electrical demand. This report is directed instead toward those manufactured products, including appliances, that are able to provide demand responses as soon as they are purchased and that require few, or no, after-market modifications to make them responsive to needs of power grids. Efforts to be summarized include Open Automated Demand Response, the Association of Home Appliance Manufacturer standard CHA 1, a simple interface being developed by the U-SNAP Alliance, various emerging autonomous responses, and the recent PinBus interface that was developed at Pacific Northwest National Laboratory.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Roles For Demand Response in More-Electrified Futures

Power systems, both supply- and demand-side, are rapidly evolving due to technological change and various policy goals. This talk will describe potential roles for demand response in future power systems serving more electrified loads (including transport) and with higher shares of variable renewable generation. Starting from a broad definition of demand response as any change imposed on demand-side end-use operations meant to support power grid functionalities, we draw on a number of past and ongoing research topics to provide insight into the value of different kinds of demand response in different kinds of power systems.

demand response↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Role of Standard Demand Response Signals for Advanced Automated Aggregation

Emerging standards such as OpenADR enable Demand Response (DR) Resources to interact directly with Utilities and Independent System Operators to allow their facility automation equipment to respond to a variety of DR signals ranging from day ahead to real time ancillary services. In addition, there are Aggregators in today’s markets who are capable of bringing together collections of aggregated DR assets and selling them to the grid as a single resource. However, in most cases these aggregated resources are not automated and when they are, they typically use proprietary technologies. There is a need for a framework for dealing with aggregated resources that supports the following requirements: • Allows demand-side resources to participate in multiple DR markets ranging from wholesale ancillary services to retail tariffs without being completely committed to a single entity like an Aggregator; • Allow aggregated groups of demand-side resources to be formed in an ad hoc fashion to address specific grid-side issues and support the optimization of the collective response of an aggregated group along a number of different dimensions. This is important in order to taylor the aggregated performance envelope to the needs to of the grid; • Allow aggregated groups to be formed in a hierarchical fashion so that each group can participate in variety of markets from wholesale ancillary services to distribution level retail tariffs. This paper explores the issues of aggregated groups of DR resources as described above especially within the context of emerging smart grid standards and the role they will play in both the management and interaction of various grid-side entities with those resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Customer enrollment and participation in building demand management programs: A review of key factors

Increasing the efficiency and flexibility of electricity demand is necessary for ensuring a cost-effective and reliable transition to zero-carbon electricity systems. Such demand-side management (DSM) resources have been procured by utilities for decades via energy efficiency and demand response programs; however, the key drivers of program enrollment and customer participation levels remain poorly understood — even as governments and grid planners seek to scale up the deployment of DSM assets to meet climate targets. Here we systematically review the evidence on multiple factors that may influence customer enrollment and participation in building DSM programs, focusing primarily on residential and commercial buildings. We examine the contexts in which relationships between DSM factors and outcomes are most often explored and with which methods; we also score the strength, direction, and internal consistency of each factor's reported impact on the enrollment and participation outcomes. We find that studies most commonly assess the effects of economic incentives for load flexibility on program participation levels, often using simulation-based methods in lieu of measured data. Few studies focus on program enrollment outcomes or regulatory drivers of either enrollment or participation, and gaps are also evident in the coverage of emerging DSM opportunities like load electrification. Removal of structural barriers (e.g., the lack of controls infrastructure) and the use of third party services (e.g., load aggregators) are the factors with the largest positive impacts on DSM outcomes, but no single factor emerges as clearly most impactful. For a given factor, the range of reported impacts typically varies widely across the relevant studies reviewed. Our findings provide a snapshot of the state of knowledge about building DSM and customer decision-making, and they expose key gaps in understanding that must be filled if building DSM is to expand as a critical resource for operating clean power grids.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Security Constrained Distributed Transaction Model for Multiple Prosumers

Massive access of renewable energy has prompted demand-side distributed resources to participate in regulation and improve flexibility of power systems. With large-scale access of massive, decentralized, and diverse distributed resources, demand-side market members have transformed from traditional “consumers” to “prosumers”. To explore the distributed transaction model of prosumers, in this paper, a multi-prosumer distributed transaction model is proposed, and the Conditional Value-at-Risk (CVaR) theory is applied to quantify potential risks caused by the stochastic characteristics inherited from renewable energy. First, a prosumer model under constraints of the distribution network including photovoltaic units, fuel cells, energy storage system, central air conditioning and flexible loads is established, and a multi-prosumer distributed transaction strategy is proposed to achieve power sharing among multiple prosumers. Second, a prosumer transaction model based on CVaR is constructed to measure risks inherited from the uncertainty of PV output within the prosumer and ensure safety of system operation in extreme PV output scenarios. Then, the alternating direction multiplier method (ADMM) is utilized to solve the constructed model efficiently. Finally, distributed transaction costs of prosumers are distributed fairly based on the generalized Nash equilibrium to maximize social benefits. Simulation results show the multi-prosumer distributed transaction mechanism established under the proposed generalized Nash equilibrium method can encourage power sharing among prosumers, increasing their own income and social benefits. Also, the CVaR can assist decision making of prosumers in weighting the risks and benefits, improving system resilience through energy management of prosumers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent Energy Optimizer for Residential Buildings

Demand-side management in the buildings is essential for meeting grid flexibility needs in a highly renewable energy scenario. Appliance load monitoring helps decision making for demand-side management by providing the information on operation status/power consumption from different appliances in the buildings. Nonintrusive load monitoring (NILM) is an attractive option for appliance load monitoring using because it has lower cost for sensors and helps mitigate privacy concerns. In this study, the team used an event detection technique followed by two different methods for event classification. The results from k-means clustering showed that the events from a single appliance are often distributed in multiple clusters. Thus, the unsupervised method of NILM using k-means clustering used in this study was not very suitable for load disaggregation. The results from NILM showed that the F1 score for event classification was 0.77 for a heat pump water heater and very low for other appliances using the rule-based classification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic analysis of the impact of dynamic electricity prices on solar penetration in a smart grid environment with distributed energy storage

This study investigates the technical and economic feasibility of using high levels of solar energy penetration up to 400 MW into a smart grid system of 60,000 smart houses. A novel non-cooperative Stackelberg game is introduced that incorporates the profitability of the supply-side and helps in solving problems related to overgeneration and photovoltaic curtailment. The non-cooperative game is intended to find the optimal dynamic prices that would leverage distributed storage through the demand-side to stabilize the power grid operation. Ten cases are studied with five photovoltaic plant sizes and two battery designs. Here, a novel quantitative analysis of high levels of solar penetration as a percentage of the total electricity demand is introduced to evaluate the technical feasibility of the studied cases. To evaluate the economic viability of the proposed smart grid system, four metrics were used: the levelized cost of energy, the levelized cost of storage, the payback period, and the net present value. Two out of ten studied cases were concluded to be the most promising cases, one with a solar photovoltaic plant size of 200 MW and the other with 300 MW. The case with 300 MW solar plant is preferred as it paves the way for more solar energy deployment with a solar penetration percentage up to 67.78%. This case had a payback period of 10.72 years and a net present value of $\$51.44$ M for the solar plant and a payback period of 12.06 years and a net present value of $\$40.75$ M for the demand-side.

14 SOLAR ENERGY↗

Integrating Demand Response and Distributed Resources in Planning for Large-scale Renewable Energy Integration

The electricity grid is transitioning from a centralized and uncoordinated set of large generators and loads to a framework that also includes decentralized and coordinated "distributed energy resources" (DER). Advances in renewable generation, energy storage, efficiency, and controls technology present a significant opportunity for demand-side investment that is matched to the needs of the future grid infrastructure and operations, but the complex interplay of controls technology and grid operations makes estimating and realizing the potential of DER a significant challenge. Supply curves for conserved energy have long been used to synthesize energy efficiency opportunities for electricity system planners and show how demand side resources compete with building new power plants. We have developed a similar approach for supporting policymakers who now face a range of technology options for DER, with a focus on describing the potential for demand response (DR) to provide flexibility to the grid. We describe our modeling approach using supply curves for demand response across four key dimensions: reshaping with rates, shedding at critical time, shifting to capture renewables, and fast-response "shimmy" to balance the grid. In a California-focused study, we find a significant potential for DR to support the grid, and a need for integration between DR and energy efficiency. The combined efficiency benefits from a better-controlled and commissioned facility can lead to significant reductions in the cost of DR, increasing the quantity that is cost competitive by 5-200%. The benefit stream from DR can alternatively be framed to "buy down" the cost of EE investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Eliminating Electricity Deficit through Energy Efficiency in India: An Evaluation of Aggregate Economic and Carbon Benefits

Electricity demand has consistently exceeded available supply in India. While the electricity deficit varies across states, nationally it was estimated to be of the order of 12percent on peak and 11percent for electricity during 2008-09. This paper explores a demand-side focused potential for energy efficiency improvement to eliminate the electricity deficit compared to a business as usual (BAU) supply-side focused scenario. The limited availability of finance and other legal and administrative barriers have constrained the construction of new power plant capacity in India. As a result, under the BAU scenario, India continues to face an electricity deficit beyond the end of the Twelfth Five Year Plan. The demand-side cost-effective potential achieved through replacement of new electricity-using products, however, is large enough to eliminate the deficit as early as 2013 and subsequently reduce the future construction of power plants and thus reduce air pollutant emissions. Moreover, energy efficiency improvements cost a fraction of the cost for new supply and can lead to a substantial increase in India's economic output or gross domestic product (GDP). Eliminating the deficit permits businesses that have experienced electricity cutbacks to restore production. We estimate the size of the cumulative production increase in terms of the contribution to GDP at a $505 billion between 2009 and 2017, the end of India's Twelfth Five Year Plan, which may be compared with India's 2007-08 GDP of $911 billion. The economic output is influenced by the size of the electricity savings and rate of penetration of energy efficient technologies, and that of self-generation equipment and inverters used by businesses faced with electricity cuts. Generation and inverters are estimated to service 23percent of these customers in 2009, which increase to 48percent by 2020. The reduction in the construction and operation of new power plants reduces the cumulative CO2 emissions by 65 Mt, and those of sulfur dioxide and nitrogen oxides by 0.4 Mt each, while also reducing India's imports of coal and natural gas. By 2020, the cumulative GDP benefit increases to $608 billion, the CO2 savings expand to 333 Mt and SO2 and NOx to 2.1 Mt.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating customer electricity savings from projects installed by the U.S. ESCO industry

The U.S. energy service company (ESCO) industry has a well-established track record of delivering substantial energy and dollar savings in the public and institutional facilities sector, typically through the use of energy savings performance contracts (ESPC) (Larsen et al. 2012; Goldman et al. 2005; Hopper et al. 2005, Stuart et al. 2013). This ~$6.4 billion industry, which is expected to grow significantly over the next five years, may play an important role in achieving demand-side energy efficiency under local/state/federal environmental policy goals. To date, there has been little or no research in the public domain to estimate electricity savings for the entire U.S. ESCO industry. Estimating these savings levels is a foundational step in order to determine total avoided greenhouse gas (GHG) emissions from demand-side energy efficiency measures installed by U.S. ESCOs. We introduce a method to estimate the total amount of electricity saved by projects implemented by the U.S. ESCO industry using the Lawrence Berkeley National Laboratory (LBNL) /National Association of Energy Service Companies (NAESCO) database of projects and LBNL’s biennial industry survey. We report two metrics: incremental electricity savings and savings from ESCO projects that are active in a given year (e.g., 2012). Overall, we estimate that in 2012 active U.S. ESCO industry projects generated about 34 TWh of electricity savings—15 TWh of these electricity savings were for MUSH market customers who did not rely on utility customer-funded energy efficiency programs (see Figure 1). This analysis shows that almost two-thirds of 2012 electricity savings in municipal, local and state government facilities, universities/colleges, K-12 schools, and healthcare facilities (i.e., the so-called “MUSH” market) were not supported by a utility customer-funded energy efficiency program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grid FriendlyTM Device Model Development and Simulation

In late 2007, the Bonneville Power Administration (BPA) contracted Pacific Northwest National Laboratory (PNNL) to complete a research project titled Grid-Responsive Demand-Side Control Using Grid Friendly Appliance Technologies [Hammerstrom 2009, DeSteese and Hammerstrom 2009]. Cosponsors included Portland General Electric (PGE) and Puget Sound Energy (PSE). The project focused on applications of the Grid Friendly Appliance (GFA) controller, which is an autonomous controller that was designed to advise devices like appliances concerning valuable demand-side grid services that should be conducted. The controller bases its advice on observations it makes from the ac voltage signal. Electric tank water heaters were selected to be controlled by the GFA controller in this project. Two autonomous responses are addressed herein. First, an under-voltage-responsive water heater is able to recognize sudden reductions in feeder circuit voltage at each water heater and may curtail any electric load that is being consumed by the water heater. These under-voltage events are usually induced by nearby electrical faults. An under-voltage response is necessarily specified by the set of voltage thresholds at which the responsive water heaters would respond. The set of voltages at which the curtailment would be released must also be specified. Additionally, any delays prior to the water heater load becoming curtailed or again released must be specified. For example, a delay may be intentionally imposed prior to curtailing water heater loads to avoid responses during the fault itself. Much longer and randomized delays should be imposed prior to the release of curtailments in order to re-establish diversity of the water heater loads and soften what could otherwise be an abrupt reintroduction of a large aggregated electrical load into the already stressed grid region.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial and Industrial Base Intermittent Resource Management Pilot

This scoping study summarizes the challenges with integrating wind and solar generation into the California's electricity grid. These challenges include: Smoothing intra-hour variability; - Absorbing excess renewable energy during over-generation periods; - Addressing morning and evening ramping periods. In addition, there are technical challenges to integrating retail demand response (DR) triggered by the wholesale conditions into the CAISO markets. The study describes the DR programs available to the consumers through the utilities in California and CAISO's ancillary services market because an integration of the wholesale and retail DR requires an understanding of these different offerings and the costs associated with acquiring them. Demand-side active and passive storage systems are proposed as technologies that may be used to mitigate the effects of intermittence due to renewable generation. Commercial building technologies as well as industrial facilities with storage capability are identified as targets for the field tests. Two systems used for ancillary services communications are identified as providing the triggers for DR enablement. Through the field tests, issues related to communication, automation and flexibility of demand-side resources will be explored and the performance of technologies that participate in the field tests will be evaluated. The major outcome of this research is identifying and defining flexibility of DR resources and optimized use of these resources to respond to grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online distributed price-based control of DR resources with competitive guarantees

Demand response (DR) of building HVAC load can provide crucial demand-side flexibility for the future smart grid. Compared to direct load control, price-based control can respect the customers’ autonomy and privacy. However, it is challenging for price-based control to attain provable performance guarantees under future uncertainty. In this paper, we propose a framework for a utility to perform price-based control of flexible building load within the utility’s service area, in order to attain competitive performance guarantees in terms of controlling the system peak demand under future uncertainty. By adopting a two-step approach, our online price-based control solution can attain a provable competitive ratio for all possible realizations within a given uncertainty set. Simulation experiments demonstrate that, with a robustification procedure, our solution can perform well not only for worst-case inputs, but also for average-case inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Who Controls Energy in the Smart Home? A Multidisciplinary Taxonomy

Advances in technology have begun to open new opportunities for behavior-based and technical approaches to managing residential energy use and meet sustainability-related objectives. Visions of the future predict homes with smart technologies delivering enhanced comfort and cost savings to residents; utility-partners who can remotely optimize energy resources to meet grid needs; and occupants who play more active roles in the energy system supported by advanced information communication technologies. Each of these scenarios implies augmented control over home energy use, yet uncertainties remain regarding which ones will deliver the greatest grid benefits and services to customers in a given situation. These scenarios also raise broader questions regarding customer agency and the relationship between customers and third parties moving forward. While both the provision of information to spur behavior change and automated technologies theoretically enhance control over energy use in the built environment, these strategies are not often studied from an integrated perspective. Seeking to address this gap and develop a deeper understanding of the evolving paradigm of control over home energy use, this paper presents a taxonomy to evaluate perspectives from public policy (ex. demand-side management), technological innovation (automated controls), and user-agency (ex. the role of behavior change) on approaches to managing home energy use. We draw on theoretical and empirical evidence from across disciplines to detail the dimensions and implications of deploying programs that incorporate various levels of control and anticipate such a taxonomy will help holistically map out and evaluate tradeoffs between different approaches to demand-side management moving forward.

McIlvennie, Claire↗