Search NASA⌕ Search

SEARCH · Search NASA

Results for “design for X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of Agfa Structurix series D4 and D3sc x-ray films in the 0.7–4.6 keV energy range

X-ray films remain a key asset for high-resolution x-ray spectral imaging in high-energy-density experiments conducted at the National Ignition Facility (NIF). The soft x-ray Opacity Spectrometer (OpSpec) fielded at the NIF has an elliptically shaped crystal design that measures x rays in the 900–2100 eV range and currently uses an image plate as the detecting medium. However, Agfa D4 and D3sc x-ray films’ higher spatial resolution provides increased spectral resolution to the data over the IP-TR image plates, driving the desire for regular use of x-ray film as a detecting medium. The calibration of Agfa D4 x-ray film for use in the OpSpec is communicated here. These calibration efforts are vital to the accuracy of the NIF opacity measurements and are conducted in a previously un-studied x-ray energy range under a new film development protocol required by NIF. The absolute response of Agfa D4 x-ray film from 705 to 4620 eV has been measured using the Nevada National Security Site Manson x-ray source. A broader range of energies was selected to compare results with previously published data. The measurements were taken using selected anodes, filters, and applied voltages to produce well-defined energy lines.

Dutra, E. C. (ORCID:0000000167649195)↗

Guest Editorial

The design of X-ray optical systems is very different from that of conventional optical systems, whether it be for the peculiarities of synchrotron radiation or the grazing incidence operation of most X-ray optical components. Further, specific simulation tools are thus required to ensure that designs work as expected, and there is now a vibrant landscape of open-source, freely available software that can be used to that end, and explore new design concepts.

47 OTHER INSTRUMENTATION↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Powering the Woods Hole X-Spar Buoy with Ocean Wave Energy—A Control Co-Design Feasibility Study

Despite its success in measuring air–sea exchange, the Woods Hole Oceanographic Institution’s (WHOI) X-Spar Buoy faces operational limitations due to energy constraints, motivating the integration of an energy harvesting apparatus to improve its deployment duration and capabilities. This work explores the feasibility of an augmented, self-powered system in two parts. Part 1 presents the collaborative design between X-Spar developers and wave energy researchers translating user needs into specific functional requirements. Based on requirements like desired power levels, deployability, survivability, and minimal interference with environmental data collection, unsuitable concepts are pre-eliminated from further feasibility study consideration. In part 2, we focus on one of the promising concepts: an internal rigid body wave energy converter. We apply control co-design methods to consider commercial of the shelf hardware components in the dynamic models and investigate the concept’s power conversion capabilities using linear 2-port wave-to-wire models with concurrently optimized control algorithms that are distinct for every considered hardware configuration. During this feasibility study we utilize two different control algorithms, the numerically optimal (but acausal) benchmark and the optimized damping feedback. We assess the sensitivity of average power to variations in drive-train friction, a parameter with high uncertainty, and analyze stroke limitations to ensure operational constraints are met. Our results indicate that a well-designed power take-off (PTO) system could significantly extend the WEC-Spar’s mission by providing additional electrical power without compromising data quality.

autonomous systems↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Optimization of the IMAGINE-X Diffractometer at NB1

An upgraded protein crystal diffractometer with Dynamic Nuclear Polarization (DNP) is proposed for installation during the next HFIR Beryllium Reflector Replacement. The diffractometer will replace the IMAGINE protein crystal diffraction instrument currently located at CG4D. The simulation design meets the needs as requested in the science requirements document.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of multilayer-based diagnostics for measurement of high energy x rays and gamma rays

We investigate several possible multilayer-based optic designs for future hard x-ray and gamma ray diagnostics, including the detection and measurement of the positron annihilation radiation at 511 keV. The focus is set on increasing the photon efficiency and signal-to-noise ratio, compared to a previous multilayer-based system that was successfully employed to measure spectra in the 55 keV–100 keV range. Several possible designs using multilayer coatings are discussed, including mirror-based optics and multilayer Laue lenses.

Burcklen, C. (ORCID:0000000271566357)↗

Propulsion System Design using a Dual 3-Phase PM Synchronous Reluctance Machine with X-Type Multi-Level GaN Inverter

— A propulsion system design is exhibited here that comprises of an X-type GaN power module based dual multi-level inverter and a PM Synchronous Reluctance motor. With the critical benefits of multi-level operation, namely low common mode EMI noise, low switching loss, low current Total Harmonic Distortion (THD), smoother torque and lower iron loss, this topology targets high system-level efficiency and high power density while using reduced rare earth (RE) elements in its motor. General Motors and Purdue University jointly designed and developed this 800V class, highly scalable traction drive that can deliver 200+ kW of power suitable for C-SUV to truck vehicle class. The 3-phase electric machine design utilizes dual winding with 6 terminals to work in line with the GaN X-type inverter, and results in a tractive solution that ensures higher machine efficiency while reducing cost and uncertainty related to use and availability of heavy rare earth/rare earth elements in its rotor.

MOMEN, FAIZUL [General Motors LLC, Detroit, MI (Un↗

De Novo Design of High‐Affinity Miniprotein Binders Targeting Francisella Tularensis Virulence Factor

Abstract Francisella tularensis poses considerable public health risk due to its high infectivity and potential for bioterrorism. Francisella‐like lipoprotein (Flpp3), a key virulence factor unique to Francisella, plays critical roles in infection and immune evasion, making it a promising target for therapeutic development. However, the lack of well‐defined binding pockets and structural information on native interactions has hindered structure‐guided ligand discovery against Flpp3. Here, we used a combination of physics‐based and deep‐learning methods to design high‐affinity miniprotein binders targeting two distinct sites on Flpp3. We identified four binders for site I with binding affinities ranging between 24–110 nM. For the second site, an initial binder showed a dissociation constant ( K D ) of 81 nM, and subsequent site saturation mutagenesis yielded variants with sub‐nanomolar affinities. Circular dichroism confirmed the topology of designed miniproteins. The X‐ray crystal structure of Flpp3 in complex with a site I binder is nearly identical to the design model (Cα root‐mean‐square deviation (RMSD): 0.9 Å). These designed miniproteins provide research tools to explore the roles of Flpp3 in tularemia and should enable the development of new therapeutic candidates.

Gokce‐Alpkilic, Gizem [Molecular Engineering and S↗

Design of a Multi-Monochromatic X-ray Imager (MMI) for Kr K-shell line emission

We report the Multi-Monochromatic X-ray Imager (MMI) is a time-gated spectrometer used in implosion experiments at the OMEGA laser facility. From the data, electron temperature and density spatial distributions can be obtained at different implosion times. Previous MMI designs used Ar K-shell emission (3–6 keV) as a spectroscopic tracer and provided a spectral resolution of around 20 eV. However, Ar K-shell line emission becomes less useful at electron temperatures above 2 keV due to over-ionization. Kr K-shell (12–16 keV) has been shown to be an attractive alternative to diagnose hot implosion cores in recent publications. The purpose of this paper is to show a new point design that allows the MMI to detect this higher photon energy range with suitable spectral resolution. The algorithm used to find the optimal design couples a ray-tracing code and an exhaustive parameter space search. This algorithm may be useful as a tool to find optimal MMI designs for other purposes, i.e., other spectral regions for other spectroscopic tracers. So, the main change between the two designs is the replacement of the multi-layer mirror with a flat Bragg Ge (220) crystal. The final Kr K-shell MMI design has a photon energy range from 12 to 16.1 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

TMS XTRRA experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory [1,2] provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

36 MATERIALS SCIENCE↗

Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

An Ultra-Compact X-ray Regenerative Amplifier Free-Electron Laser

There is a growing interest in designing and building compact X-ray Free Electron Lasers (FELs) for scientific and industry applications. In this paper, we report an X-ray Regenerative Amplifier FEL (XRAFEL) design based on a proposed Ultra Compact X-ray FEL configuration. Our results show that an XRAFEL can dramatically enhance the temporal coherence and increase the spectral brightness of the radiation in the hard X-ray regime without increasing the footprint of the FEL configuration. The proposed compact, fully coherent, and high-flux hard X-ray source holds promise as a valuable candidate for a wide range of high-impact applications in both academia and industry.

Singleton, Madison↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography↗