Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection probability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigation on Reaction Probabilities for Cyclic Voltammetry of Zirconium in LiCl-KCl Eutectic Molten Salt via Reverse-Engineering Method

This work focuses on a reverse-engineering program design for the cyclic voltammetry (CV) method to help illustrating, enhancing, and providing robustness in detection probability of the reactions during an electrorefining process. Analyzing the reactions from CV plots for 1.07, 2.49, and 4.98 wt% of zirconium chloride (ZrCl{sub 4}) in a LiCl-KCl molten salt at 773 K under different scan rates from Hoover's study has been accomplished. The results provide the current (Amp) versus potential (V) to investigate the optimum probability of the reactions at each peak. All simulations have been done through the commercial software MATLAB by using various experimental values existing in the literature as a first guess (e.g., the diffusion coefficients, and formal potentials). Preliminary results indicate that the zirconium reactions at each peak from cathodic to anodic side for 1.07 wt% are as followed: combination of Zr{sup +2}/Zr and Zr{sup +4}/ Zr{sup +2} at approximately -1.15 V, Zr{sup +2}/Zr at -1.5 V, Zr{sup +4}/Zr at -1.85 V, 70% Zr/Zr{sup +4} and 30% Zr/Zr{sup +2} at -0.5 V, and Zr{sup +2}/ Zr{sup +4} at - 0.25 V. These mentioned peaks are similar for 2.49 wt% at different voltages. In addition, the highest anodic peak for 4.98 wt% is found to be a combination of 30% Zr/Zr{sup +4} and 70% Zr/Zr{sup +2}. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ON THE COMPLEMENTARITY OF PULSAR TIMING AND SPACE LASER INTERFEROMETRY FOR THE INDIVIDUAL DETECTION OF SUPERMASSIVE BLACK HOLE BINARIES

Gravitational waves coming from supermassive black hole binaries (SMBHBs) are targeted by both the Pulsar Timing Array (PTA) and Space Laser Interferometry (SLI). The possibility of a single SMBHB being tracked first by PTA, through inspiral, and later by SLI, up to merger and ring-down, has been previously suggested. Although the bounding parameters are drawn by the current PTA or the upcoming Square Kilometer Array (SKA), and by the New Gravitational Observatory (NGO), derived from the Laser Interferometer Space Antenna (LISA), this paper also addresses sequential detection beyond specific project constraints. We consider PTA-SKA, which is sensitive from 10{sup -9} to p Multiplication-Sign 10{sup -7} Hz (p = 4, 8), and SLI, which operates from s Multiplication-Sign 10{sup -5} up to 1 Hz (s = 1, 3). An SMBHB in the range of 2 Multiplication-Sign 10{sup 8}-2 Multiplication-Sign 10{sup 9} M {sub Sun} (the masses are normalized to a (1 + z) factor, the redshift lying between z = 0.2 and z = 1.5) moves from the PTA-SKA to the SLI band over a period ranging from two months to fifty years. By combining three supermassive black hole (SMBH)-host relations with three accretion prescriptions, nine astrophysical scenarios are formed. They are then related to three levels of pulsar timing residuals (50, 5, 1 ns), generating 27 cases. For residuals of 1 ns, sequential detection probability will never be better than 4.7 Multiplication-Sign 10{sup -4} yr{sup -2} or 3.3 Multiplication-Sign 10{sup -6} yr{sup -2} (per year to merger and per year of survey), according to the best and worst astrophysical scenarios, respectively; put differently this means one sequential detection every 46 or 550 years for an equivalent maximum time to merger and duration of the survey. The chances of sequential detection are further reduced by increasing values of the s parameter (they vanish for s = 10) and of the SLI noise, and by decreasing values of the remnant spin. The spread in the predictions diminishes when timing precision is improved or the SLI low-frequency cutoff is lowered. So while transit times and the SLI signal-to-noise ratio (S/N) may be adequate, the likelihood of sequential detection is severely hampered by the current estimates on the number-just a handful-of individual inspirals observable by PTA-SKA, and to a lesser extent by the wide gap between the pulsar timing and space interferometry bands, and by the severe requirements on pulsar timing residuals. Optimization of future operational scenarios for SKA and SLI is briefly dealt with, since a detection of even a single event would be of paramount importance for the understanding of SMBHBs and of the astrophysical processes connected to their formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic planning of moving target defence for maximising detection effectiveness against false data injection attacks in smart grid

Abstract Moving target defence (MTD) has been gaining traction to thwart false data injection attacks against state estimation (SE) in the power grid. MTD actively perturbs the reactance of transmission lines equipped with distributed flexible AC transmission system (D‐FACTS) devices to falsify the attacker's knowledge about the system configuration. However, the existing literature has not systematically studied what influences the detection effectiveness of MTD and how it can be improved based on the topology analysis. These problems are tackled here from the perspective of an MTD plan in which the D‐FACTS placement is determined. We first exploit the relation between the rank of the composite matrix and the detecting effectiveness. Then, we rigorously derive upper and lower bounds on the attack detecting probability of MTDs with a given rank of the composite matrix. Furthermore, we analyse existing planning methods and highlight the importance of bus coverage by D‐FACTS devices. To improve the detection effectiveness, we propose a novel graph theory–based planning algorithm to retain the maximum rank of the composite matrix while covering all necessary buses. Comparative results on multiple systems show the high detecting effectiveness of the proposed algorithm in both DC‐ and AC‐SE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Faint Object Detection in Multi-Epoch Observations via Catalog Data Fusion

Astronomy in the time-domain era faces several new challenges. One of them is the efficient use of observations obtained at multiple epochs. The work presented here addresses faint object detection and describes an incremental strategy for separating real objects from artifacts in ongoing surveys. The idea is to produce low-threshold single-epoch catalogs and to accumulate information across epochs. This is in contrast to more conventional strategies based on co-added or stacked images. We adopt a Bayesian approach, addressing object detection by calculating the marginal likelihoods for hypotheses asserting that there is no object or one object in a small image patch containing at most one cataloged source at each epoch. The object-present hypothesis interprets the sources in a patch at different epochs as arising from a genuine object; the no-object hypothesis interprets candidate sources as spurious, arising from noise peaks. We study the detection probability for constant-flux objects in a Gaussian noise setting, comparing results based on single and stacked exposures to results based on a series of single-epoch catalog summaries. Our procedure amounts to generalized cross-matching: it is the product of a factor accounting for the matching of the estimated fluxes of the candidate sources and a factor accounting for the matching of their estimated directions. We find that probabilistic fusion of multi-epoch catalogs can detect sources with similar sensitivity and selectivity compared to stacking. The probabilistic cross-matching framework underlying our approach plays an important role in maintaining detection sensitivity and points toward generalizations that could accommodate variability and complex object structure.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY VARIABILITY AND EVIDENCE FOR PULSATIONS FROM THE UNIQUE RADIO PULSAR/X-RAY BINARY TRANSITION OBJECT FIRST J102347.6+003841

We report on observations of the unusual neutron-star binary system FIRST J102347.6+003841 carried out using the XMM-Newton satellite. This system consists of a radio millisecond pulsar (PSR J1023+0038) in a 0.198 day orbit with a {approx}0.2 M{sub sun} Roche-lobe-filling companion and appears to have had an accretion disk in 2001. We observe a hard power-law spectrum ({Gamma} = 1.26(4)) with a possible thermal component, and orbital variability in X-ray flux and possibly hardness of the X-rays. We also detect probable pulsations at the pulsar period (single-trial significance {approx}4.5{sigma} from an 11(2)% modulation), which would make this the first system in which both orbital and rotational X-ray pulsations are detected. We interpret the emission as a combination of X-rays from the pulsar itself and from a shock where material overflowing the companion meets the pulsar wind. The similarity of this X-ray emission to that seen from other millisecond pulsar binary systems, in particular 47 Tuc W (PSR J0024 - 7204W) and PSR J1740 - 5340, suggests that they may also undergo disk episodes similar to that seen in J1023 in 2001.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of Low-level Point Radioactive Sources using a sensor network

Identification of a low-level point radioactive source amidst background radiation is achieved by a network of radiation sensors using a two-step approach. Based on measurements from three or more sensors, a geometric difference triangulation method or an N-sensor localization method is used to estimate the location and strength of the source. Then a sequential probability ratio test based on current measurements and estimated parameters is employed to finally decide: (1) the presence of a source with the estimated parameters, or (2) the absence of the source, or (3) the insufficiency of measurements to make a decision. This method achieves specified levels of false alarm and missed detection probabilities, while ensuring a close-to-minimal number of measurements for reaching a decision. This method minimizes the ghost-source problem of current estimation methods, and achieves a lower false alarm rate compared with current detection methods. This method is tested and demonstrated using: (1) simulations, and (2) a test-bed that utilizes the scaling properties of point radioactive sources to emulate high intensity ones that cannot be easily and safely handled in laboratory experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Merits of pressure and geochemical data as indicators of CO 2 /brine leakage into a heterogeneous, sedimentary aquifer

This study assesses the merits of pressure data and geochemical data as indicators of a combined CO 2 /brine leakage into a heterogeneous, sedimentary aquifer. We simulate the changes in three aquifer responses (pressure, total dissolved solids (TDS), and pH) due to CO 2 /brine leakage at an abandoned well with an uncertain location and hypothesize that these changes can only be observed from a single shallow monitoring well, mimicking the low density of observation wells for the considered aquifer. Specifically, detection likelihoods are calculated to describe how frequently pressure, TDS, and pH signals will coincide with a leak for observations made at different distances and times from the initiation of the CO 2 /brine leakage rate. The pressure signal gives a more spatially extensive signal than either TDS or pH, and pressure detection probabilities increase upstream of flow barriers (pressurizing-affect). The pH and TDS rebound down-stream of the flow barriers. Finally, when only considering the samples that experience the highest leakage volumes, there is a 50% likelihood of detecting a pressure change 400 m away at times ≥30 years. However, the TDS and pH detection likelihoods are <20% at 100 m distance for times ≥30 years.

58 GEOSCIENCES↗

Probing parity violation with the four-point correlation function of BOSS galaxies

Parity-violating physics in the early universe can leave detectable traces in late-time observables. While vector- and tensor-type parity violation can be observed in the B -modes of the cosmic microwave background, scalar-type signatures are visible only in the four-point correlation function (4PCF) and beyond. This work presents a blind test for parity violation in the 4PCF of the baryon oscillation spectroscopic survey (BOSS) CMASS sample, considering galaxy separations in the range [20; 160]h -1 Mpc The parity-odd 4PCF contains no contributions from standard Λ CDM physics and can be efficiently measured using recently developed estimators. Data are analyzed using both a nonparametric rank test (comparing the BOSS 4PCFs to those of realistic simulations) and a compressed χ 2 analysis, with the former avoiding the assumption of a Gaussian likelihood. These find similar results, with the rank test giving a detection probability of 99.6% (2.9 σ). This provides significant evidence for parity violation, from either cosmological sources or systematics. We perform a number of systematic tests: although these do not reveal any observational artifacts, we cannot exclude the possibility that our detection is caused by the simulations not faithfully representing the statistical properties of the BOSS data. Our measurements can be used to constrain physical models of parity violation. As an example, we consider a coupling between the inflaton and a U (1) gauge field and place bounds on the latter’s energy density, which are several orders of magnitude stronger than those previously reported. Upcoming probes such as DESI and Euclid will reveal whether our detection of parity violation is due to new physics, and strengthen the bounds on a variety of models.

79 ASTRONOMY AND ASTROPHYSICS↗

Dose and detectability for a cone-beam C-arm CT system revisited

Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose){sup 1/2}. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose){sup 1/3} and (dose){sup 1/2.8}, respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.

36 MATERIALS SCIENCE↗

Safeguards Envelope Progress FY10

The Safeguards Envelope is a strategy to determine a set of specific operating parameters within which nuclear facilities may operate to maximize safeguards effectiveness without sacrificing safety or plant efficiency. This paper details the additions to the advanced operating techniques that will be applied to real plant process monitoring (PM) data from the Idaho Chemical Processing Plant (ICPP). Research this year focused on combining disparate pieces of data together to maximize operating time with minimal downtime due to safeguards. A Chi-Square and Croiser's cumulative sum were both included as part of the new analysis. Because of a major issue with the original data, the implementation of the two new tests did not add to the existing set of tests, though limited one-variable optimization made a small increase in detection probability. Additional analysis was performed to determine if prior analysis would have caused a major security or safety operating envelope issue. It was determined that a safety issue would have resulted from the prior research, but that the security may have been increased under certain conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FOLLOW-UP OBSERVATIONS OF THE SECOND AND THIRD KNOWN PULSATING HOT DQ WHITE DWARFS

We present follow-up time-series photometric observations that confirm and extend the results of the significant discovery made by Barlow et al. that the Hot DQ white dwarfs SDSS J220029.08 - 074121.5 and SDSS J234843.30 - 094245.3 are luminosity variable. These are the second and third known members of a new class of pulsating white dwarfs, after the prototype SDSS J142625.71+575218.3. We find that the light curve of SDSS J220029.08 - 074121.5 is dominated by an oscillation at 654.397 +- 0.056 s, and that the light pulse folded on that period is highly nonlinear due to the presence of the first and second harmonic of the main pulsation. We also present evidence for the possible detection of two additional pulsation modes with low amplitudes and periods of 577.576 +- 0.226 s and 254.732 +- 0.048 s in that star. Likewise, we find that the light curve of SDSS J234843.30 - 094245.3 is dominated by a pulsation with a period of 1044.168 +- 0.012 s, but with no sign of harmonic components. A new oscillation, with a low amplitude and a period of 416.919 +- 0.004 s, is also probably detected in that second star. We argue, on the basis of the very different folded pulse shapes, that SDSS J220029.08 - 074121.5 is likely magnetic, while SDSS J234843.30 - 094245.3 is probably not.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting gravitational waves from inspiraling binaries with a network of geographically separated detectors: Coherent versus coincident strategies

We compare two strategies of multidetector detection of compact binary inspiral signals, namely, the coincidence and the coherent for the realistic case of geographically separated detectors. The naive coincident strategy treats the detectors as if they are isolated - compares individual detector statistics with their respective thresholds while the coherent strategy combines the detector network data coherently to obtain a single detection statistic which is then compared with a single threshold. We also consider an enhanced coincidence strategy which is intermediate in the sense that though the individual statistics are added in quadrature and the sum compared with a single threshold, the estimated parameters are also checked for consistency. For simplicity, we consider detector pairs having the same power spectral density of noise, as that of initial LIGO and also assume the noise to be stationary and Gaussian. Further, since we consider the detectors to be widely separated on Earth, we take the instrumental noises to be uncorrelated; the wide separation implicitly means that since the detector arms must lie parallel to the Earth's surface, the detectors necessarily have different orientations. We compare the performances of the methods by plotting the receiver operating characteristics for the strategies. Several results are derived analytically in order to gain insight. Simulations are performed in order to plot the receiver operating characteristic (ROC) curves. A single astrophysical source as well as a distribution of sources is considered. We assume a 1 yr data train and a mass range of 1-40M{sub {center_dot}} for the case of astrophysically distributed sources. We find that the coherent strategy is superior to the two coincident strategies that we consider. Remarkably, the detection probability of the coherent strategy is 50% better than the naive coincident strategy. One the other hand, the difference in performance between the coherent strategy and enhanced coincident strategy is not very large. Even in this situation, it is not difficult to perform the real data analysis with the coherent strategy. The bottom line is that the coherent strategy is a good detection strategy.

99 GENERAL AND MISCELLANEOUS↗

Data Reconciliation and Gross Error Detection: A Filtered Measurement Test

Measured process data commonly contain inaccuracies because the measurements are obtained using imperfect instruments. As well as random errors one can expect systematic bias caused by miscalibrated instruments or outliers caused by process peaks such as sudden power fluctuations. Data reconciliation is the adjustment of a set of process data based on a model of the process so that the derived estimates conform to natural laws. In this paper, we will explore a predictor-corrector filter based on data reconciliation, and then a modified version of the measurement test is combined with the studied filter to detect probable outliers that can affect process measurements. The strategy presented is tested using dynamic simulation of an inverted pendulum.

99 GENERAL AND MISCELLANEOUS↗

MARKOV Model Application to Proliferation Risk Reduction of an Advanced Nuclear System

The Generation IV International Forum (GIF) emphasizes proliferation resistance and physical protection (PR&PP) as a main goal for future nuclear energy systems. The GIF PR&PP Working Group has developed a methodology for the evaluation of these systems. As an application of the methodology, Markov model has been developed for the evaluation of proliferation resistance and is demonstrated for a hypothetical Example Sodium Fast Reactor (ESFR) system. This paper presents the case of diversion by the facility owner/operator to obtain material that could be used in a nuclear weapon. The Markov model is applied to evaluate material diversion strategies. The following features of the Markov model are presented here: (1) An effective detection rate has been introduced to account for the implementation of multiple safeguards approaches at a given strategic point; (2) Technical failure to divert material is modeled as intrinsic barriers related to the design of the facility or the properties of the material in the facility; and (3) Concealment to defeat or degrade the performance of safeguards is recognized in the Markov model. Three proliferation risk measures are calculated directly by the Markov model: the detection probability, technical failure probability, and proliferation time. The material type is indicated by an index that is based on the quality of material diverted. Sensitivity cases have been done to demonstrate the effects of different modeling features on the measures of proliferation resistance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimally configuring a measurement system to detect diversions from a nuclear fuel cycle

The civilian nuclear fuel cycle is an industrial process that produces electrical power from the nuclear fission of uranium. Using a measurement system to accurately account for nuclear material, such as uranium, in a fuel cycle is important because of the possible loss or diversion of this potentially dangerous material. A measurement system is defined by a set of measurement methods, or “devices,” used to account for material flows and inventory values at specific locations in the fuel cycle. Here, we develop a simulation-optimization algorithm and an integer-programming model to find the best, or near-best, resource-limited measurement system with a high degree of confidence. The simulation-optimization algorithm minimizes a weighted sum of false positive and false negative diversion-detection probabilities while accounting for material quantities and measurement errors across a finite, discrete time horizon in hypothetical non-diversion and diversion contexts. In each time period, the estimated cumulative material unaccounted for is compared to a fixed or an optimized threshold value to assess if a “significant amount of material” is lost from a measurement system. The integer-programming model minimizes the population variance of the estimated material loss, i.e., material unaccounted for, in a measurement system. We analyze three potential problems in nuclear fuel cycle measurement systems: (i) given location-dependent device precisions, find the configuration of n devices at n locations ( n = 3) that gives the lowest corresponding objective values using the simulation-optimization algorithm and integer-programming model, (ii) find the location at which improving device precision reduces objective values the most using the simulation-optimization algorithm, and determine the effect of measurement frequency on measurement system configurations and objective values using the simulation-optimization algorithm. We obtain comparable results for each problem at least an order of magnitude faster than existing methods do. Using an optimized, rather than fixed, detection threshold in the simulation-optimization algorithm reduces the weighted sum of false positive and false negative probabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Variability in Performance of a Machine Learning Seismicity Catalog: Central Italy, 2016–2017

Machine learning (ML) catalogs contain many more earthquakes than routine catalogs, but their performance in phase picking and earthquake detection has not been fully evaluated. We develop station‐level detection probabilities using logistic regression and combine them across a seismic network to compute spatial magnitude‐of‐completeness fields. We apply this approach to two catalogs from the 2016–2017 Central Italy sequence that were constructed from the same seismic network, one routine and one ML‐based. At the station level, the ML picker increases detection sensitivity by identifying smaller magnitude events and detecting earthquakes at greater distances. Spatially, the magnitude of completeness decreases substantially, with median values shifting from 1.6 to 0.5 for P waves and from 1.7 to 0.5 for S waves. However, the ML catalog also shows greater variability in station‐level performance than the routine catalog. These results demonstrate that ML‐based improvements in detectability are widespread but spatially nonuniform, highlighting their benefits, their limitations, and the potential for further improvements.

15 GEOTHERMAL ENERGY↗

ON THE PROGENITOR SYSTEM OF THE TYPE Iax SUPERNOVA 2014dt IN M61

We present pre-explosion and post-explosion Hubble Space Telescope images of the Type Iax supernova (SN Iax) 2014dt in M61. After astrometrically aligning these images, we do not detect any stellar sources at the position of the SN in the pre-explosion images to relatively deep limits (3σ limits of M {sub F438W} > –5.0 mag and M {sub F814W} > –5.9 mag). These limits are similar to the luminosity of SN 2012Z's progenitor system (M {sub F435W} = –5.43 ± 0.15 and M {sub F814W} = –5.24 ± 0.16 mag), the only probable detected progenitor system in pre-explosion images of a SN Iax, and indeed, of any white-dwarf supernova. SN 2014dt is consistent with having a C/O white-dwarf primary/helium-star companion progenitor system, as was suggested for SN 2012Z, although perhaps with a slightly smaller or hotter donor. The data are also consistent with SN 2014dt having a low-mass red giant or main-sequence star companion. The data rule out main-sequence stars with M {sub init} ≳ 16 M {sub ☉} and most evolved stars with M {sub init} ≳ 8 M {sub ☉} as being the progenitor of SN 2014dt. Hot Wolf-Rayet stars are also allowed, but the lack of nearby bright sources makes this scenario unlikely. Because of its proximity (D = 12 Mpc), SN 2014dt is ideal for long-term monitoring, where images in ∼2 yr may detect the companion star or the luminous bound remnant of the progenitor white dwarf.

79 ASTRONOMY AND ASTROPHYSICS↗

A Neutron Based Scanner to Detect Explosives in Small, Sealed Containers

A scanning system has been designed for portal protection applications, with the capability of detecting explosive materials after an initial scan of 30 seconds. The scanner operates using the principle of neutron induced return gamma-ray spectrometry. This system utilizes high purity germanium detectors, a neutron generator based on deuterium-tritium fusion and a unique neutron reflector and guide design. The neutron reflector amplifies the flux and alters the energy spectrum of neutrons produced by the generator. A depleted uranium reflector is shown to perform 7.3 times better than no reflector, and is found to perform 1.5 times better than a tungsten reflector using MCNP simulation. This improvement is due to neutron knockout and induced fission occurring in depleted uranium. The system is capable of detecting 300 g of explosives with 90% detection probability, which includes a 15% rescan rate after a 30 second initial scan.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗