Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

The ASD Scorpius Accelerator at the NNSS. Recruitment Slides for the University of Nevada, Reno [Slides]

The Scorpius Accelerator: Supports the maintenance of the US nuclear stockpile, helps the US not return to nuclear testing, is one of four diagnostics being installed 963 feet below ground, probes subcritical implosions of nuclear material, and supports the validation of LANL and LLNL computer codes. We are searching engineers and scientists with experienced in: Mechanical Engineering, Electrical Engineering, Pulsed Power, Plasma Physics, Controls, Diagnostics, and Fluids and pressure systems.

42 ENGINEERING↗

S&TR July-August: Beyond Ignition

On December 5, 2022, Lawrence Livermore’s National Ignition Facility achieved the first-ever successful positive-gain ignition shot. This scientific advance, heralded worldwide, required a multidecadal effort to synthesize physics theory, laser technologies, computation and diagnostic capabilities, as well as engineering, materials development, and other inputs. The question, “Can ignition be achieved?” had been answered. Since then, the Laboratory has answered the question, “Can we do it again?” with additional ignition shots at increasing yield. Now Lawrence Livermore researchers ask, “Can we improve ignition outcomes?” for the benefit of the Stockpile Stewardship Program. Interrelated articles presenting the Laboratory’s ignition science, the role of supercomputing in achieving ignition, the evolution of diagnostic instruments to measure ignition data, and the ambitious steps required to realize a fusion energy future lead to one answer: “Yes, we can.”

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

43 PARTICLE ACCELERATORS↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

Enhanced NIF neutron activation diagnostics

The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the {sup 89}Zr/{sup 89m}Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metamaterials for Cherenkov Radiation Based Particle Detectors

Measurement of Cherenkov radiation (CR) has long been a useful technique for charged particle detection and beam diagnostics. We are investigating metamaterials engineered to have refractive indices tailored to enhance properties of CR that are useful for particle detectors and that cannot be obtained using conventional media. Cherenkov radiation in dispersive media with a large refractive index differs significantly from the same effect in conventional detector media, like gases or aerogel. The radiation pattern of CR in dispersive metamaterials presents lobes at very large angles with respect to particle motion. Moreover, the frequency and particle velocity dependence of the radiated energy can differ significantly from CR in a conventional dielectric medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NSLS-II longitudinal impedance budget

From the beginning of the NSLS-II project, the vacuum chamber of the NSLS-II storage ring has been optimized to reduce its impedance. The optimization, performed in close collaboration with the Diagnostic, Vacuum, RF, and Mechanical Engineering groups, has been achieved via calculating the impedance of the vacuum chamber components with the use of both analytical and numerical tools, with the numerical computations carried out with the GdfidL code. Fore reliable NSLS-II operation with the total beam current of 500 mA, each component of the vacuum chamber has been individually optimized to minimize the beam-induced heating and to prevent single-bunch and coupled-bunch instabilities. In this study, the impedance calculation and optimization know-how are summarized for all the chamber components, and the total longitudinal impedance budget is analyzed. As a result of this extensive research and engineering effort, the design beam current of 500 mA has been recently accumulated in NSLS-II without any major problem caused by collective effects.

43 PARTICLE ACCELERATORS↗

TH-AB-206-00: Challenges and Opportunities for Nuclear Medicine Theranostics

In the past few decades, the field of nuclear medicine has made long strides with the continued advancement of related sciences and engineering and the availability of diagnostic and therapeutic radionuclides. Leveraging these advancements while combining the advantages of therapeutic and diagnostic radionuclides into one radiopharmaceutical has also created a new subfield “theranostics” in nuclear medicine that has the potential to further propel the field into the future. This session is composed of two talks; one focused on the physics principles of theranostics from properties of beta and alpha emitting radionuclides to dosimetric models and quantification; while the second describes preclinical and clinical applications of theranostics and discusses the challenges and opportunities of bringing them to the clinic. At the end of the session the listener should be able to identify: The different properties of beta and alpha emitting radionuclides Which radionuclides are selected for which nuclear medicine therapies and why How PET can be used to accurately quantify the uptake of tumor targeting molecules How individualized dosimetry can be performed from the management of thyroid cancer to novel radiolabeled antibody therapies Promising pre-clinical radiopharmaceutical pairs in prostate cancer and melanoma. Promising clinical Theranostics in neuroendocrine cancers. Challenges of bringing Theranostics to the clinic. E. Delpassand, RITA Foundation -Houston; SBIR Grant; CEO and share holder of RadioMedix.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-206-01: Advances in Radionuclide Therapy - From Radioiodine to Nanoparticles

In the past few decades, the field of nuclear medicine has made long strides with the continued advancement of related sciences and engineering and the availability of diagnostic and therapeutic radionuclides. Leveraging these advancements while combining the advantages of therapeutic and diagnostic radionuclides into one radiopharmaceutical has also created a new subfield “theranostics” in nuclear medicine that has the potential to further propel the field into the future. This session is composed of two talks; one focused on the physics principles of theranostics from properties of beta and alpha emitting radionuclides to dosimetric models and quantification; while the second describes preclinical and clinical applications of theranostics and discusses the challenges and opportunities of bringing them to the clinic. At the end of the session the listener should be able to identify: The different properties of beta and alpha emitting radionuclides Which radionuclides are selected for which nuclear medicine therapies and why How PET can be used to accurately quantify the uptake of tumor targeting molecules How individualized dosimetry can be performed from the management of thyroid cancer to novel radiolabeled antibody therapies Promising pre-clinical radiopharmaceutical pairs in prostate cancer and melanoma. Promising clinical Theranostics in neuroendocrine cancers. Challenges of bringing Theranostics to the clinic. E. Delpassand, RITA Foundation -Houston; SBIR Grant; CEO and share holder of RadioMedix.

60 APPLIED LIFE SCIENCES↗

TH-AB-206-02: Nuclear Medicine Theronostics: Wave of the Future; Pre-Clinical and Clinical Opportunities

In the past few decades, the field of nuclear medicine has made long strides with the continued advancement of related sciences and engineering and the availability of diagnostic and therapeutic radionuclides. Leveraging these advancements while combining the advantages of therapeutic and diagnostic radionuclides into one radiopharmaceutical has also created a new subfield “theranostics” in nuclear medicine that has the potential to further propel the field into the future. This session is composed of two talks; one focused on the physics principles of theranostics from properties of beta and alpha emitting radionuclides to dosimetric models and quantification; while the second describes preclinical and clinical applications of theranostics and discusses the challenges and opportunities of bringing them to the clinic. At the end of the session the listener should be able to identify: The different properties of beta and alpha emitting radionuclides Which radionuclides are selected for which nuclear medicine therapies and why How PET can be used to accurately quantify the uptake of tumor targeting molecules How individualized dosimetry can be performed from the management of thyroid cancer to novel radiolabeled antibody therapies Promising pre-clinical radiopharmaceutical pairs in prostate cancer and melanoma. Promising clinical Theranostics in neuroendocrine cancers. Challenges of bringing Theranostics to the clinic. E. Delpassand, RITA Foundation -Houston; SBIR Grant; CEO and share holder of RadioMedix.

61 RADIATION PROTECTION AND DOSIMETRY↗

Learnings from the Marcellus Shale Energy and Environmental Lab (MSEEL) Using Fiber Optic Tools and Geomechanical Modeling

The study focuses on the MIP and Boggess pads of the MSEEL (Marcellus Shale Energy and Environmental Laboratory), a public-private partnership with a mandate to publicly release data for scientists and engineers to engage with. Multiple diagnostic tools are used to characterize the formation and monitor fracture treatment and propagation. Geomechanical modeling is used to understand the insitu stresses, microseismic to describe half-lengths and heights, and fiber optics to characterize offset well. Fracture Driven Interactions (FDI’s) and interstage communication. Recent publications covering the MSEEL MIP-3H and MIP-5H wells are reviewed and discussed. A preview of the findings from the Boggess pad (first production in November 2019) is also shared here

03 NATURAL GAS↗

Operating displays - new concept: high performance displays - 118

New control rooms in Nuclear Power Plants using digital Distributed Control System (DCS) operated with software displays, are providing thousands of signals to the operating crew. When an event happens, the Flood of information provided to operators could obscure the initiator event increasing the operator response time, work load and complicating the selection of the actions to be performed. There are some initiatives that are trying to minimize the 'avalanche effect' as the alarm engineering filtering and prioritization or diagnostic displays. Likewise, new control rooms are lost the availability to know the plant status just with a quick glance to the panel indicators. Regarding Small Modular Reactors, where in some cases four operators should monitor and control twelve reactors, these problems are even more significant. The challenge is to find a solution, based on current digital systems, that supply information to operators in order to prevent events and take early actions to minimize or avoid any unexpected incident. In order to minimize human errors, Tecnatom has developed a specific set of displays, called 'High Performance Displays' (HPD) based on objectives, work environment limitation, and non-anticipated events. These displays are being design following the HFE standards: applying the NUREG-0711 elements to identify the information that they have to content and the NUREG-0700 to design the interface. The function of these displays is monitoring the plant situation in a way that the operators are able to recognize any potential event at a simple glance but controlling thousands of signals through pattern recognition, symmetries, regular polygons and colors. The objective of the HPD is to provide an integrated function minimizing the tunnel effect and reduce the workload during the diagnosis phase. Moreover, HPD enhance operators to take the right actions to anticipate the response to any event, even avoiding it, if possible This paper analyzes how HPD's have been design as well as presents the results of a preliminary validation of their capabilities. The preliminary validation is a reduce validation in a full scope simulator running two representative scenarios of abnormal and emergency operation. The analysis is focused on the first stage of the event, i.e. the detection phase, HPD's have been installed in a generic full scope simulator of a nuclear power plant, digital controlled. Both scenarios have been performed by two different operator crews. The first operator shift has worked with the conventional human machine interface, that is, displays similar to the ones currently installed in existing nuclear power plant with digital control. The second crew, reproduce the same scenarios but with HPD available. The studio collects preliminary data in order to compare results, draw lesson learned from the experience to improve HPD design, and find solutions in terms of reducing human errors, human workload, and increase the availability of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗