Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Formation of electron bunches with tailored current profiles using multi-frequency linacs

Tailoring an electron bunch with specific current profile can provide substantial enhancement of the transformer ratio in beam-driven acceleration methods. We present a method relying on the use of a linac with accelerating sections operating at different frequencies followed by a magnetic bunch compressor. The experimental verfification of the technique in a two-frequency linac is presented. The compatibility of the proposed technique with the formation and acceleration of a drive and witness bunches is numerically demonstrated.

43 PARTICLE ACCELERATORS↗

Fast phase stabilization of a low frequency beat note for atom interferometry

Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 μs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the {sup 87}Rb recoil frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rigorous theory of molecular orientational nonlinear optics

Classical statistical mechanics of the molecular optics theory proposed by Buckingham [A. D. Buckingham and J. A. Pople, Proc. Phys. Soc. A 68, 905 (1955)] has been extended to describe the field induced molecular orientational polarization effects on nonlinear optics. In this paper, we present the generalized molecular orientational nonlinear optical processes (MONLO) through the calculation of the classical orientational averaging using the Boltzmann type time-averaged orientational interaction energy in the randomly oriented molecular system under the influence of applied electric fields. The focal points of the calculation are (1) the derivation of rigorous tensorial components of the effective molecular hyperpolarizabilities, (2) the molecular orientational polarizations and the electronic polarizations including the well-known third-order dc polarization, dc electric field induced Kerr effect (dc Kerr effect), optical Kerr effect (OKE), dc electric field induced second harmonic generation (EFISH), degenerate four wave mixing (DFWM) and third harmonic generation (THG). We also present some of the new predictive MONLO processes. For second-order MONLO, second-order optical rectification (SOR), Pockels effect and difference frequency generation (DFG) are described in terms of the anisotropic coefficients of first hyperpolarizability. And, for third-order MONLO, third-order optical rectification (TOR), dc electric field induced difference frequency generation (EFIDFG) and pump-probe transmission are presented.

36 MATERIALS SCIENCE↗

The turbulent bremsstrahlung (plasma-maser) effect

Because of nonlinear interaction between particles and waves, energy conversion between waves of large frequency difference can occur without particle population inversion or resonant wave-wave interaction. The effect involves the nonresonant interaction of the plasma particles with a pair of plasma modes of large frequency difference, and wave energy is converted into particle energy. This effect can appear in laboratory as well as astrophysical plasmas and is important in determining the transport properties of weakly turbulent plasmas. Here, the most important aspects of the plasma-maser theory is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Effects of Second-Order Hydrodynamics on a Semisubmersible Floating Offshore Wind Turbine: Preprint

The objective of this paper is to assess the second-order hydrodynamic effects on a semisubmersible floating offshore wind turbine. Second-order hydrodynamics induce loads and motions at the sum- and difference-frequencies of the incident waves. These effects have often been ignored in offshore wind analysis, under the assumption that they are significantly smaller than first-order effects. The sum- and difference-frequency loads can, however, excite eigenfrequencies of the system, leading to large oscillations that strain the mooring system or vibrations that cause fatigue damage to the structure. Observations of supposed second-order responses in wave-tank tests performed by the DeepCwind consortium at the MARIN offshore basin suggest that these effects might be more important than originally expected. These observations inspired interest in investigating how second-order excitation affects floating offshore wind turbines and whether second-order hydrodynamics should be included in offshore wind simulation tools like FAST in the future. In this work, the effects of second-order hydrodynamics on a floating semisubmersible offshore wind turbine are investigated. Because FAST is currently unable to account for second-order effects, a method to assess these effects was applied in which linearized properties of the floating wind system derived from FAST (including the 6x6 mass and stiffness matrices) are used by WAMIT to solve the first- and second-order hydrodynamics problems in the frequency domain. The method has been applied to the OC4-DeepCwind semisubmersible platform, supporting the NREL 5-MW baseline wind turbine. The loads and response of the system due to the second-order hydrodynamics are analysed and compared to first-order hydrodynamic loads and induced motions in the frequency domain. Further, the second-order loads and induced response data are compared to the loads and motions induced by aerodynamic loading as solved by FAST.

17 WIND ENERGY↗

Exciton dressing by extreme nonlinear magnons in a layered semiconductor

Collective excitations presenting nonlinear dynamics are fundamental phenomena with broad applications. A prime example is nonlinear optics, where diverse frequency mixing processes are central to communication, sensing, wavelength conversion, and attosecond physics. Leveraging recent progress in van der Waals magnetic semiconductors, we demonstrate nonlinear opto-magnonic coupling by presenting exciton states dressed by up to 20 harmonics of magnons, resulting from their nonlinearities, in the layered antiferromagnetic semiconductor CrSBr. We also create tunable optical side bands from sum- and difference-frequency generation between two optically bright magnon modes under symmetry breaking magnetic fields. Moreover, the observed difference-frequency generation mode can be continuously tuned into resonance with one of the fundamental magnons, resulting in parametric amplification of magnons. These findings realize the modulation of the optical frequency exciton with the extreme nonlinearity of magnons at microwave frequencies, which could find applications in magnonics and hybrid quantum systems, and provide new avenues for implementing opto-magnonic devices.

Diederich, Geoffrey M.↗

Bio-inspired non self-similar hierarchical elastic metamaterials

Hierarchy provides unique opportunities for the design of advanced materials with superior properties that arise from architecture, rather than from constitutive material response. Contrary to the quasi-static regime, where the potential of hierarchy has been largely explored, its role in vibration mitigation and wave manipulation remains elusive. So far, the majority of the studies concerning hierarchical elastic metamaterials have proposed a self-similar repetition of a specific unit cell at multiple scale levels, leading to the activation of the same bandgap mechanism at different frequencies. On the contrary, here, we show that by designing non self-similar hierarchical geometries allows us to create periodic structures supporting multiple, highly attenuative and broadband bandgaps involving (independently or simultaneously) different scattering mechanisms, namely, Bragg scattering, local resonance and/or inertial amplification, at different frequencies. The type of band gap mechanism is identified and discussed by examining the vibrational mode shapes and the imaginary component of the wavenumber in the dispersion diagram of the unit cell. Finally, we also experimentally confirm this by performing measurements in the lowest frequency regime on a 3D printed structure. Hierarchical design strategies may find application in vibration mitigation for civil, aerospace and mechanical engineering.

36 MATERIALS SCIENCE↗

Statistical mechanics and pressure of composite multimoded weakly nonlinear optical systems

Statistical mechanics can provide a versatile theoretical framework for investigating the collective dynamics of weakly nonlinear-wave settings that can be utterly complex to describe otherwise. In optics, composite systems arise due to interactions between different frequencies and polarizations. The purpose of this work is to develop a thermodynamic theory that takes into account the synergistic action of multiple components. We find that the type of the nonlinearity involved can have important implications in the thermalization process and, hence, can lead to different thermal equilibrium conditions. Importantly, we derive closed-form expressions for the actual optomechanical pressure that is exerted on the system. In particular, the total optomechanical pressure is the sum of the partial pressures due to each component. Our results can be applied to a variety of weakly nonlinear optical settings such as multimode fibers, bulk waveguides, photonic lattices, and coupled microresonators. We present two specific examples, where two colors interact in a one-waveguide array with either a cubic or quadratic nonlinearity.

Efremidis, Nikolaos K. (ORCID:0000000298300268)↗

Energy storage cell impedance measuring apparatus, methods and related systems

Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

25 ENERGY STORAGE↗

The Impact of White Dwarf Luminosity Profiles on Oscillation Frequencies

KIC 08626021 is a pulsating DB white dwarf (WD) of considerable recent interest, and the first of its class to be extensively monitored by Kepler for its pulsation properties. Fitting the observed oscillation frequencies of KIC 08626021 to a model can yield insights into its otherwise-hidden internal structure. Template-based WD models choose a luminosity profile where the luminosity is proportional to the enclosed mass, ${L}_{r}\,\propto \,{M}_{r}$, independent of the effective temperature T eff . Evolutionary models of young WDs with T eff ≳ 25,000 K suggest that neutrino emission gives rise to luminosity profiles with L r ${/}\!\!\!\!\!\!{\propto }$ M r . We explore this contrast by comparing the oscillation frequencies between two nearly identical WD models: one with an enforced ${L}_{r}\propto {M}_{r}$ luminosity profile, and the other with a luminosity profile determined by the star's previous evolution history. We find that the low-order g-mode frequencies differ by up to ≃70 μHz over the range of Kepler observations for KIC 08626021. This suggests that by neglecting the proper thermal structure of the star (e.g., accounting for the effect of plasmon neutrino losses), the model frequencies calculated by using an ${L}_{r}\propto {M}_{r}$ profile may have uncorrected, effectively random errors at the level of tens of μHz. A mean frequency difference of 30 μHz, based on linearly extrapolating published results, suggests a template model uncertainty in the fit precision of ≃12% in WD mass, ≃9% in the radius, and ≃3% in the central oxygen mass fraction.

79 ASTRONOMY AND ASTROPHYSICS↗

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background: A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Gill, Ajay S. [National Research Council of Canada↗

Synthesis of Pt nanoparticles on electrochemically reduced graphene oxide by potentiostatic and alternate current methods

Reduced graphene oxide (RGO) has been synthesized on Pt wires by means of a potentiodynamic method between + 0.6 V and − 1.4 V for 20 scans. Cyclic voltammetry characterization of the coatings showed the typical capacitative behavior of graphene. Pt nanoparticles were synthesized on Pt–RGO electrodes by means of potentiostatic methods and a comparison between different synthesis potentials (− 0.16, 0, + 0.2 and + 0.4 V) for the same synthesis charge (mC·cm{sup −2}) was established. The electrodes obtained were characterized in 0.5 M H{sub 2}SO{sub 4} solution to observe the characteristic oxidation and reduction processes of the Pt surface. A 0.5 M H{sub 2}SO{sub 4}/0.5 M CH{sub 3}OH solution was used to measure the catalytic properties of the deposits against methanol oxidation. The most appropriate potential to perform the synthesis was 0 V followed by − 0.16 V and + 0.2 V. The morphology of the coatings varied depending on the potential applied as observed by scanning electron microscopy. Alternate current methods were also used to synthesize Pt nanoparticles and compare the results with the traditional potentiostatic method. Different frequencies were used: 0.1, 1, 10, 100, 1000 and 10 000 Hz. Alternate current synthesis is more efficient than traditional potentiostatic methods, obtaining more electroactive coatings with less effective synthesis time. - Highlights: • Reduced graphene oxide has been obtained by electrochemical reduction on Pt wires. • Pt nanoparticles have been obtained potentiostatically at different potentials. • Pt nanoparticles have been obtained by ac methods with different frequencies. • ac synthesis is a better synthesis method than potentiostatic synthesis.

36 MATERIALS SCIENCE↗

Enhancement of Second-Order Nonlinear-Optical Signals by Optical Stimulation

Second-order nonlinear optical interactions such as sum- and difference-frequency generation are widely used for bioimaging and as selective probes of interfacial environments. However, inefficient nonlinear optical conversion often leads to poor signal-to-noise ratio and long signal acquisition times. We demonstrate the dramatic enhancement of weak second-order nonlinear optical signals via stimulated sum- and difference-frequency generation. We present a conceptual framework to quantitatively describe the interaction and show that the process is highly sensitive to the relative optical phase of the stimulating field. To emphasize the utility of the technique, we demonstrate stimulated enhancement of second harmonic generation (SHG) from bovine collagen-I fibrils. Using a stimulating pulse fluence of only $3\text{ }\text{ }\mathrm{nJ}/{\mathrm{cm}}^{2}$, we obtain an SHG enhancement >${10}^{4}$ relative to the spontaneous signal. The stimulation enhancement is greatest in situations where spontaneous signals are the weakest—such as low laser power, small sample volume, and weak nonlinear susceptibility—emphasizing the potential for this technique to improve signal-to-noise ratios in biological imaging and interfacial spectroscopy.

42 ENGINEERING↗

Towards Universal Non-Dimensional Characterization of the Oscillatory Dynamics of Wind Turbine Rotors of Multiple Sizes

One concern in the field of Horizontal Axis Wind Turbines (HAWTs) is what control strategies are needed to handle gust pulses in the wind to prevent extreme oscillations of the blades to reduce fatigue stress, prevent blade rupture, and extend the turbine’s operational life. In order to design innovative control strategies to modify the blade’s oscillatory response, it is crucial to establish the fundamental vibrational behavior of the blades when excited by gust pulses of different frequencies and amplitudes present in the fluctuating wind inflow. In a series of previous works, the authors presented a novel Reduced-Order Characterization (ROC) technique that provided an energy-based characterization of the fundamental modes of oscillation of wind turbine rotors when excited by combinations of wind gust pulses of different frequencies and amplitudes. The main focus of the present work is to extend these original notions of energy-based ROC to a universal technique expressed in terms of non-dimensional quantities that could be applied to turbines of any size, operating in any set of wind conditions, as long as they share geometrical and material similarity. The ROC technique provides a simple formula that is capable of predicting the dominant vibrational modes of a blade with sufficient precision to be useful in the determination of a control decision that can be computed in real time, an aspect of fundamental importance in dealing with rapid fluctuations in wind conditions.

Yates, North (ORCID:000900052204261X)↗

Applications of Subsurface Microscopy

Exploring the interior of a cell is of tremendous importance in order to assess the effects of nanomaterials on biological systems. Outside of a controlled laboratory environment, nanomaterials will most likely not be conveniently labeled or tagged so that their translocation within a biological system cannot be easily identified and quantified. Ideally, the characterization of nanomaterials within a cell requires a nondestructive, label-free, and subsurface approach. Subsurface nanoscale imaging represents a real challenge for instrumentation. Indeed the tools available for high resolution characterization, including optical, electron or scanning probe microscopies, mainly provide topography images or require tagants that fluoresce. Although the intercellular environment holds a great deal of information, subsurface visualization remains a poorly explored area. Recently, it was discovered that by mechanically perturbing a sample, it was possible to observe its response in time with nanoscale resolution by probing the surface with a micro-resonator such as a microcantilever probe (Figure 1). Microcantilevers are used as the force-sensing probes in Atomic Force Microscopy (AFM), where the nanometer-scale probe tip on the microcantilever interacts with the sample in a highly controlled manner to produce high-resolution raster-scanned information of the sample surface. Taking advantage of the existing capabilities of AFM, we present a novel technique, Mode Synthesizing Atomic Force Microscopy (MSAFM) (Figure 1), which has the ability to probe subsurface structures such as non-labeled nanoparticles embedded in a cell. In MSAFM mechanical actuators (PZTs) excite the probe and the sample at different frequencies as depicted in Figure 1. The nonlinear nature of the tip-sample interaction, at the point of contact of the probe and the surface of the sample, in the contact mode AFM configuration permits the mixing of the elastic waves. The new dynamic system comprises new synthesized imaging modes, resulting from sum- and difference-frequency generation of the driving frequencies. The specific electronics of MSAFM allows the selection of individual modes and the monitoring of their amplitude and phase. From these quantities of various synthesized modes a series of images can be acquired. The new images contain subsurface information, thus revealing the presence of nanoparticles inside the cells.

Tetard, Laurene↗

Validation of Broadly Filtered Diagonalization Method for Extracting Frequencies and Modes from High-Performance Computations

Recent developments have shown that one can get around the difficulties of finding the eigenvalues and eigenmodes of the large systems studied with high performance computation by using broadly filtered diagonalization [G. R. Werner and J. R. Cary, J. Compo Phys. 227, 5200 (2008)]. This method can be used in conjunction with any time-domain computation, in particular those that scale very well up to 10000s of processors and beyond. Here we present results that show that this method accurately obtains both modes and frequencies of electromagnetic cavities, even when frequencies are nearly degenerate. The application was to a well-characterized Kaon separator cavity, the A15. The computations are shown to have a precision to a few parts in 10{sup 5}. Because the computed frequency differed from the measured frequency by more than this amount, a careful validation study to determine all sources of difference was undertaken. Ultimately, more precise measurements of the cavity showed that the computations were correct, with remaining differences accounted for by uncertainties in cavity dimensions and atmospheric and thermal conditions. Thus, not only was the method validated, but it was shown to have the ability to predict differences in cavity dimensions from fabrication specifications.

99 GENERAL AND MISCELLANEOUS↗

Generation of uniform large-area very high frequency plasmas by launching two specific standing waves simultaneously

With the characteristics of higher electron density and lower ion bombardment energy, large-area VHF (very high frequency) plasma enhanced chemical vapor deposition has become an essential manufacturing equipment to improve the production throughput and efficiency of thin film silicon solar cell. However, the combination of high frequency and large electrodes leads to the so-called standing wave effect causing a serious problem for the deposition uniformity of silicon thin film. In order to address this issue, a technique based on the idea of simultaneously launching two standing waves that possess similar amplitudes and are out of phase by 90° in time and space is proposed in this study. A linear plasma reactor with discharge length of 54 cm is tested with two different frequencies including 60 and 80 MHz. The experimental results show that the proposed technique could effectively improve the non-uniformity of VHF plasmas from >±60% when only one standing wave is applied to <±10% once two specific standing waves are launched at the same time. Moreover, in terms of the reactor configuration adopted in this study, in which the standing wave effect along the much shorter dimension can be ignored, the proposed technique is applicable to different frequencies without the need to alter the number and arrangement of power feeding points.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗