Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference in differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NASA HECC Geometry and Performance Review Part 2: Geometric Differences Between the as-Manufactured and Design-Intent Impeller Geometry and Their Effects on the Vaneless Diffuser Configuration Performance

An investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. This multipart investigation focused on validating the computational model against experimental data. The validated model was then used to explore the effects of observed geometric differences between the as-manufactured and design-intent impellers. Lastly, the validated model was used for comparison against an experimental tip clearance study. Details regarding each of the parts are detailed below: This second part of a multipart investigation of the NASA HECC vaneless diffuser configuration focused on the comparison of the as-manufactured HECC vaneless computational model validated in Part I against a new model that used the same grid and solver settings but replaced the impeller section data with the design-intent sections from NASA/CR-2014-218114/Rev1. The 1D performance values showed that the as-manufactured impeller underperformed compared to the design-intent for all four speedlines that were simulated. Further investigation of radial profiles, loading and contours showed consistent underperformance of the as-manufactured. An investigation into the source of the difference led to the discovery of several geometric differences in the two impellers of magnitudes that could not be explained outside of manufacturing. The differences that were observed can be summarized into four categories: fillets, TE exit radius differences, splitter LE differences and main blade thickness differences. The investigation then shifted to attempting to isolate the geometric differences as best as possible and to understand their contribution to the observed underperformance. The investigation showed that out of the four geometric differences that were explored, the differences in the splitter blade had the largest effect.

centrifugal compressor↗

Functionally discrete fine roots differ in microbial assembly, microbial functional potential, and produced metabolites

Traditionally, fine roots were grouped using arbitrary size categories, rarely capturing the heterogeneity in physiology, morphology and functionality among different fine root orders. Fine roots with different functional roles are rarely separated in microbiome-focused studies and may result in confounding microbial signals and host-filtering across different root microbiome compartments. Using a 26-year-old common garden, we sampled fine roots from four temperate tree species that varied in root morphology and sorted them into absorptive and transportive fine roots. The rhizoplane and rhizosphere were characterized using 16S rRNA gene and internal transcribed spacer region amplicon sequencing and shotgun metagenomics for the rhizoplane to identify potential microbial functions. Fine roots were subject to metabolomics to spatially characterize resource availability. Both fungi and bacteria differed according to root functional type. We observed additional differences between the bacterial rhizoplane and rhizosphere compartments for absorptive but not transportive fine roots. Rhizoplane bacteria, as well as the root metabolome and potential microbial functions, differed between absorptive and transportive fine roots, but not the rhizosphere bacteria. Functional differences were driven by sugar transport, peptidases and urea transport. Our data highlights the importance of root function when examining root-microbial relationships, emphasizing different host selective pressures imparted on different root microbiome compartments.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of finite-difference schemes for analysis of shells of revolution

Several finite difference schemes are applied to the stress and free vibration analysis of homogeneous isotropic and layered orthotropic shells of revolution. The study is based on a form of the Sanders-Budiansky first-approximation linear shell theory modified such that the effects of shear deformation and rotary inertia are included. A Fourier approach is used in which all the shell stress resultants and displacements are expanded in a Fourier series in the circumferential direction, and the governing equations reduce to ordinary differential equations in the meridional direction. While primary attention is given to finite difference schemes used in conjunction with first order differential equation formulation, comparison is made with finite difference schemes used with other formulations. These finite difference discretization models are compared with respect to simplicity of application, convergence characteristics, and computational efficiency. Numerical studies are presented for the effects of variations in shell geometry and lamination parameters on the accuracy and convergence of the solutions obtained by the different finite difference schemes. On the basis of the present study it is shown that the mixed finite difference scheme based on the first order differential equation formulation and two interlacing grids for the different fundamental unknowns combines a number of advantages over other finite difference schemes previously reported in the literature.

Noor, A. K.↗

Consequences of Different Air-Sea Feedbacks on Ocean Using MITgcm and MERRA-2 Forcing: Implications for Coupled Data Assimilation Systems

Ocean surface flux estimates from atmospheric and oceanic reanalyses contain errors that compensate for inaccuracies in the respective atmosphere and ocean models used to generate these reanalyses. A conundrum for climate studies is the discrepancy between surface fluxes that minimize model-data differences for an atmosphere-only model vs surface fluxes that minimize model-data differences for an ocean model. As a first step towards a consistent coupled ocean-atmosphere data-assimilation (DA) system, we compare surface net heat flux from a state-of-the-art atmospheric reanalysis, the Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), to net heat flux from a state-of-the-art ocean state estimate, the Estimating the Circulation and Climate of the Ocean Version 4 (ECCO-v4). The possible impacts of the MERRA-2 and ECCO-v4 air-sea net heat flux difference in a coupled DA system were assessed using a set of experiments designed to imitate different “flavors” of a coupled DA system in an ocean-only setup. This was done by forcing the ECCO-v4 underlying ocean model - the Massachusetts Institute of Technology general circulation model (MITgcm) - with different sets of MERRA-2 fields and utilizing different forcing methods. By doing so we were able to turn off different air-sea feedbacks which, in a coupled DA setup, are partially muted by the constraining observations. The set of experiments, therefore, represents a range of active feedbacks in different “flavors” of coupled data-assimilation systems. For the period 1992–2011, MERRA-2 net heat flux has a global mean difference of -4.9 Wm(exp -2) relative to ECCO-v4. When MERRA-2 surface fields are used to force MITgcm, imbalances in the energy and the hydrological cycles of MERRA-2, which are directly related to the fact that MERRA-2 was created without an interactive ocean, propagate to the ocean. The experiment in which MITgcm is forced with MERRA-2 fluxes (MERRA-2-flux experiment) results in a 2.5°C global mean Sea Surface Temperature (SST) cooling, a 1m reduction in global mean sea level, and other drastic changes in the large scale ocean circulation relative to those resulting when the MITgcm is forced with the optimized ECCO-v4 net heat flux (the ECCO-v4 experiment itself). When MITgcm is forced with MERRA-2 state variables (MERRA-2-state experiment), the SST is somewhat restored to the observed SST, but the errors are shifted to the water cycle, resulting in a global mean sea level increase of 2.7 m. To further explore the pros and cons of these two approaches, we introduce a new intermediate forcing method in which the ocean is forced with turbulent fluxes but has a long wave feedback. This method, unlike MERRA-2 state, preserves the MERRA-2 water and salinity cycles, and it reduces the SST error compared to the MERRA-2-flux experiment, but the SST is not as good as that in the MERRA-2-state experiment. Our results have implications for ocean-model forcing recipes and clearly reveal the undesirable consequences of limiting the feedbacks in either these types of experiments or in coupled DA.

Ehud Strobach↗

Investigation of the Differences in Onset Times for Magnetically Conjugate Magnetometers

We have identified nearly 1,000 onsets using two pairs of hemispheric conjugate ground magnetometers where the onset is defined based on a sharp decline in the H component of the magnetic field at a ground magnetometer station. Specifically, we used the pair of stations at West Antarctica Ice Sheet Divide and Sanikiluaq, Canada; Syowa, Antarctica; and Tjörnes, Iceland. While the onset time in the southern hemisphere is identified by eye, the value of the differences in the onset time between the northern and southern hemispheres is determined using cross covariance. We observe differences in the onset time between the two hemispheres as large as several minutes, but 53% of the events show no difference in the onset time. Using statistics, we show that the largest differences in onset time are associated with the summer and winter seasons and when the IMF By value is limited between 0.5 and 2.5 nT, which is the IMF By range when the local time difference between the northern and southern hemisphere foot points is the smallest. The results indicate that ionospheric conductivity associated with solar illumination plays a role in the differences in onset time between the northern and southern hemisphere when only non-zero differences in onset time are considered. We validate these results with two other less robust methods. The median value of the differences in onset time indicates that the onsets occur ∼23 s earlier in the winter hemisphere than that in the summer hemisphere. It has been reported that the time difference between the start of the substorm in the magnetotail and the observed auroral break up (substorm auroral onset) in the ionosphere is 30 s to 2 min in the current disruption model and the near earth neutral line model, respectively. Our results may be of interest to those two models.

James M. Weygand↗

NASA HECC Geometry and Performance Review Part 2: Geometric Differences Between the As-Manufactured and Design-Intent Impeller Geometry and their Effects on the Vaneless Diffuser Configuration Performance

An investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. This multipart investigation focused on validating the computational model against experimental data. The validated model was then used to explore the effects of observed geometric differences between the As-Manufactured and Design-Intent impellers. Lastly, the validated model was used for comparison against an experimental tip clearance study. Part II of the investigation of the NASA HECC vaneless diffuser configuration focused on understanding the differences in geometry and performance between the As-Manufactured impeller and the Design-Intent impeller. This was achieved through comparison of the As-Manufactured HECC vaneless computational model, developed from the solid model of the impeller and validated in Part I, against a new model developed from the Design-Intent blade sections published in NASA/CR-2014-218114/Rev1. The 1D performance values showed that the As-Manufactured impeller underperformed compared to the Design-Intent for all four speedlines that were simulated. Further investigation of profiles, loading and contours showed consistent underperformance of the As-Manufactured relative to the Design-Intent. An investigation into the source of the performance differences led to the discovery of several significant variations in the impeller geometries. The differences that were observed can be summarized into four categories: fillets, trailing-edge exit radii variation, dissimilarity in the splitter leading-edge geometry and main blade thickness differences. The investigation then shifted its effort to quantify the performance effects caused by geometric differences. The investigation showed that out of the four geometric differences that were explored, the differences in the splitter blade had the largest impact. These differences most notably changed flow physics near the splitter leading edge, especially near the tip of the impeller.

centrifugal compressor↗

Scale dependence in functional equivalence and difference in the soil microbiome

Climatic history can shape the functioning of soil microbial communities and thus rates of ecosystem processes such as organic matter decomposition. For example, broad spatial scale differences in climatic history, such as contrasting precipitation regimes, have been shown to generate unique microbial functional responses to contemporary moisture conditions. Yet it is an open question as to whether local differences in soil microclimate similarly influence the functional potential of decomposer communities. Here, we use a multi-scale approach within and among two temperate forest field sites to investigate this question. Soils from fifty-four microsites, that vary in their soil moisture climate-regimes, were used as inocula for a common leaf litter (Quercus rubra L.) in a controlled, laboratory microcosm study. Microcosms were placed under dry, mesic and wet lab-moisture conditions and the rate of carbon (C) mineralization of the litter was measured over 202 days. Our results reveal differences in decomposition rates under controlled conditions that highlight broad-scale functional differences between the soil communities at each site. Specifically, we found that C mineralization differed by as much as two-fold for soil communities when compared between the sites. Our results also show that functional differences of soil communities are observable within one site but not the other. In the site where local-scale functional legacies were apparent, the historical soil moisture microclimate-regimes generated as much as an 89% change in C mineralization rates of the leaf litter under the same contemporary, lab-imposed moisture conditions. Here, a similar pattern was not observable in the other site; instead, laboratory moisture conditions explained almost all variation in C mineralization. Notably, for the site with pronounced local-scale functional legacies, there was much greater within-site variation in field-soil microsite moisture than at the site which did not exhibit functional legacies, suggesting that the extent of local-scale variation in microclimate may act as control on whether local-scale functional legacies are observed. Regardless of whether this mechanism does explain our findings, our observations do confirm those from prior studies where regional-scale moisture-regime differences shape microbial function, and extend this prior work by providing evidence that pronounced local-scale differences in soil moisture microclimate-regimes are associated with microbial functional legacies.

54 ENVIRONMENTAL SCIENCES↗

Slope-Aspect Induced Climate Differences Influence How Water Is Exchanged Between the Land and Atmosphere

Cross-slope climate differences in the midlatitudes are ecologically important, and impact vegetation-mediated water balance between the earth surface and the atmosphere. We made high-resolution in situ observations of air temperature, relative humidity, soil moisture, insolation, and sap velocity observations on 14 Pacific madrone trees (Arbutus menziesii) spanning adjacent north and south slopes at the University of California's Angelo Coast Range Reserve. To understand the cross-slope response of sap velocity, a proxy for transpiration, to microclimate, we modeled the sap velocity on each slope using a transpiration model driven by ambient environment and parameterized with a Markov Chain Monte Carlo parameter estimation process. The results show that trees on opposing slopes do not follow a shared pattern of physiological response to transpiration drivers. This means that the observed sap velocity differences are not due entirely to observed microclimate differences, but also due to population-level physiological differences, which indicates acclimation to inhabited microclimate. While our present data set and analytical tools do not identify mechanisms of acclimation, we speculate that differing proportions of sun-adapted and shade-adapted leaves, differences in stomatal regulation, and cross-slope root zone moisture differences could explain some of the observed and modeled differences.

54 ENVIRONMENTAL SCIENCES↗

Determinants of rural-urban differences in health care provider visits among women of reproductive age in the United States

Background Rural health disparities and access gaps may contribute to higher maternal and infant morbidity and mortality. Understanding and addressing access barriers for specialty women’s health services is important in mitigating risks for adverse childbirth events. The objective of this study was to investigate rural-urban differences in health care access for women of reproductive age by examining differences in past-year provider visit rates by provider type, and quantifying the contributing factors to these findings. Methods and findings Using a nationally-representative sample of reproductive age women (n = 37,026) from the Medical Expenditure Panel Survey (2010–2015) linked to the Area Health Resource File, rural-urban differences in past-year office visit rates with health care providers were examined. Blinder-Oaxaca decomposition analysis quantified the portion of disparities explained by individual- and county-level sociodemographic and provider supply characteristics. Overall, there were no rural-urban differences in past-year visits with women’s health providers collectively (65.0% vs 62.4%), however differences were observed by provider type. Rural women had lower past-year obstetrician-gynecologist (OB-GYN) visit rates than urban women (23.3% vs. 26.6%), and higher visit rates with family medicine physicians (24.3% vs. 20.9%) and nurse practitioners/physician assistants (NPs/PAs) (24.6% vs. 16.1%). Lower OB-GYN availability in rural versus urban counties (6.1 vs. 13.7 providers/100,000 population) explained most of the rural disadvantage in OB-GYN visit rates (83.8%), and much of the higher family physician (80.9%) and NP/PA (50.1%) visit rates. Other individual- and county-level characteristics had smaller effects on rural-urban differences. Conclusion Although there were no overall rural-urban differences in past-year visit rates, the lower OB-GYN availability in rural areas appears to affect the types of health care providers seen by women. Whether rural women are receiving adequate specialized women’s health care services, while seeing a different cadre of providers, warrants further investigation and has particular relevance for women experiencing high-risk pregnancies and deliveries.

60 APPLIED LIFE SCIENCES↗

On the differences in the vertical distribution of modeled aerosol optical depth over the southeastern Atlantic

Abstract. The southeastern Atlantic is home to an expansive smoke aerosol plume overlying a large cloud deck for approximately a third of the year. The aerosol plume is mainly attributed to the extensive biomass burning activities that occur in southern Africa. Current Earth system models (ESMs) reveal significant differences in their estimates of regional aerosol radiative effects over this region. Such large differences partially stem from uncertainties in the vertical distribution of aerosols in the troposphere. These uncertainties translate into different aerosol optical depths (AODs) in the planetary boundary layer (PBL) and the free troposphere (FT). This study examines differences of AOD fraction in the FT and AOD differences among ESMs (WRF-CAM5, WRF-FINN, GEOS-Chem, EAM-E3SM, ALADIN, GEOS-FP, and MERRA-2) and aircraft-based measurements from the NASA ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES) field campaign. Models frequently define the PBL as the well-mixed surface-based layer, but this definition misses the upper parts of decoupled PBLs, in which most low-level clouds occur. To account for the presence of decoupled boundary layers in the models, the height of maximum vertical gradient of specific humidity profiles from each model is used to define PBL heights. Results indicate that the monthly mean contribution of AOD in the FT to the total-column AOD ranges from 44 % to 74 % in September 2016 and from 54 % to 71 % in August 2017 within the region bounded by 25∘ S–0∘ N–S and 15∘ W–15∘ E (excluding land) among the ESMs. ALADIN and GEOS-Chem show similar aerosol plume patterns to a derived above-cloud aerosol product from the Moderate Resolution Imaging Spectroradiometer (MODIS) during September 2016, but none of the models show a similar above-cloud plume pattern to MODIS in August 2017. Using the second-generation High Spectral Resolution Lidar (HSRL-2) to derive an aircraft-based constraint on the AOD and the fractional AOD, we found that WRF-CAM5 produces 40 % less AOD than those from the HSRL-2 measurements, but it performs well at separating AOD fraction between the FT and the PBL. AOD fractions in the FT for GEOS-Chem and EAM-E3SM are, respectively, 10 % and 15 % lower than the AOD fractions from the HSRL-2. Their similar mean AODs reflect a cancellation of high and low AOD biases. Compared with aircraft-based observations, GEOS-FP, MERRA-2, and ALADIN produce 24 %–36 % less AOD and tend to misplace more aerosols in the PBL. The models generally underestimate AODs for measured AODs that are above 0.8, indicating their limitations at reproducing high AODs. The differences in the absolute AOD, FT AOD, and the vertical apportioning of AOD in different models highlight the need to continue improving the accuracy of modeled AOD distributions. These differences affect the sign and magnitude of the net aerosol radiative forcing, especially when aerosols are in contact with clouds.

54 ENVIRONMENTAL SCIENCES↗

Application of a trigonometric finite difference procedure to numerical analysis of compressive and shear buckling of orthotropic panels

A numerical analysis developed for the buckling of rectangular orthotropic layered panels under combined shear and compression is described. This analysis uses a central finite difference procedure based on trigonometric functions instead of using the conventional finite differences which are based on polynomial functions. Inasmuch as the buckle mode shape is usually trigonometric in nature, the analysis using trigonometric finite differences can be made to exhibit a much faster convergence rate than that using conventional differences. Also, the trigonometric finite difference procedure leads to difference equations having the same form as conventional finite differences; thereby allowing available conventional finite difference formulations to be converted readily to trigonometric form. For two-dimensional problems, the procedure introduces two numerical parameters into the analysis. Engineering approaches for the selection of these parameters are presented and the analysis procedure is demonstrated by application to several isotropic and orthotropic panel buckling problems. Among these problems is the shear buckling of stiffened isotropic and filamentary composite panels in which the stiffener is broken. Results indicate that a break may degrade the effect of the stiffener to the extent that the panel will not carry much more load than if the stiffener were absent.

Stein, M.↗

The precise computation of geoid undulation differences with comparison to results obtained from the global positioning system

Ellipsoidal height differences have been determined for 13 station pairs in the central Ohio region using measurements made with the Global Positioning System. This information was used to compute geoid undulation differences based on known orthometric heights. These differences were compared to gravimetrically-computed undulations (using a Stokes integration procedure, and least squares collocation having an internal r.m.s. agreement of plus or minus 1 cm in undulation differences). The two sets of undulation differences have an r.m.s. discrepancy of plus or minus 5 cm while the average station separation is of the order of 14 km. This good agreement suggests that gravimetric data can be used to compute accurate geoid undulation differences that can be used to convert ellipsoidal height differences obtained from GPS to orthometric height differences.

Engelis, T.↗

Analysis of differences between seating positions in simulators and orbiters

Crew comments indicate that Space Shuttle simulator seats place crewmembers in a position different from that of the actual Orbiter seats. The crew feel that they launch in a different position, and with a different reach and visibility, from that in which they had trained. This study examined three factors in differences between training and flight positions. Key dimensions, which were considered important to spatial orientation, were compared in the Orbiters and simulators. These were dimensions such as seat back to glare shield and seat pan to overhead. The differences between flight and training crew equipment, and how these differences may contribute to the problem were discussed with engineers and technicians responsible for the equipment. Eye position measurements were taken on subjects to assess any differences that could be attributed to different ingress methods in the Orbiters and the simulators. This report presents the data, analysis, and recommendations.

Mongan, Philip T.↗

Experiments with explicit filtering for LES using a finite-difference method

The equations for large-eddy simulation (LES) are derived formally by applying a spatial filter to the Navier-Stokes equations. The filter width as well as the details of the filter shape are free parameters in LES, and these can be used both to control the effective resolution of the simulation and to establish the relative importance of different portions of the resolved spectrum. An analogous, but less well justified, approach to filtering is more or less universally used in conjunction with LES using finite-difference methods. In this approach, the finite support provided by the computational mesh as well as the wavenumber-dependent truncation errors associated with the finite-difference operators are assumed to define the filter operation. This approach has the advantage that it is also 'automatic' in the sense that no explicit filtering: operations need to be performed. While it is certainly convenient to avoid the explicit filtering operation, there are some practical considerations associated with finite-difference methods that favor the use of an explicit filter. Foremost among these considerations is the issue of truncation error. All finite-difference approximations have an associated truncation error that increases with increasing wavenumber. These errors can be quite severe for the smallest resolved scales, and these errors will interfere with the dynamics of the small eddies if no corrective action is taken. Years of experience at CTR with a second-order finite-difference scheme for high Reynolds number LES has repeatedly indicated that truncation errors must be minimized in order to obtain acceptable simulation results. While the potential advantages of explicit filtering are rather clear, there is a significant cost associated with its implementation. In particular, explicit filtering reduces the effective resolution of the simulation compared with that afforded by the mesh. The resolution requirements for LES are usually set by the need to capture most of the energy-containing eddies, and if explicit filtering is used, the mesh must be enlarged so that these motions are passed by the filter. Given the high cost of explicit filtering, the following interesting question arises. Since the mesh must be expanded in order to perform the explicit filter, might it be better to take advantage of the increased resolution and simply perform an unfiltered simulation on the larger mesh? The cost of the two approaches is roughly the same, but the philosophy is rather different. In the filtered simulation, resolution is sacrificed in order to minimize the various forms of numerical error. In the unfiltered simulation, the errors are left intact, but they are concentrated at very small scales that could be dynamically unimportant from a LES perspective. Very little is known about this tradeoff and the objective of this work is to study this relationship in high Reynolds number channel flow simulations using a second-order finite-difference method.

Lund, T. S.↗

Large 0/12 GMT Differences of US Vaisala RS80 Observations

The daily differences between the temperatures and heights taken at 0 GMT and 12 GMT by Vaisala RS80 rawinsondes have been calculated. The observations were obtained during selected months from 1998 - 2002 over North America, Europe and Australia. The daily differences are defined by the formula, Delta T = Delta T(sub 0) - 0.5(T(sub -12) - T(sub +12)) where AT is the 0/12 GMT difference, T(sub 0) is the 0 GMT observation and T(sub -12) and T(sub +12) are the 12 GMT observations taken just prior and after the 0 GMT synoptic time. If T(sub +12) is missing then Delta T = T(sub 0) - T(sub -12). A similar expression is used if T(sub -12) is missing. Monthly averages of the increments at each station that launch RS80 rawinsondes are then calculated. The results show positive systematic differences in the stratosphere with values as high as 5 K and 150 m at 10 hPa over the central United States. The values remain generally positive and gradually decrease as the levels descend into the upper troposphere but are still significant. In addition, the maximum at each level is just westward of 90 W at the highest levels and just eastward in the troposphere with smaller values along both coasts. In Canada as well as in Europe and Australia the differences are much smaller with no systematic patterns similar to those that exist over the contiguous United States. Time-series plots of the temperatures and heights at select stations in the United States show that the observed values taken at 0 GMT are consistently higher than those at 12 GMT. Over Canada the differences become much less apparent and some cases non-existent. The observations were obtained through National Centers for Environmental Prediction (NCEP) but were checked with data from other sources to verify that no modifications were made other than those at the stations. Since the data from outside the the United States exhibit no large systematic differences, the preliminary conclusion is that the large differences are artificial and probably originate from the post-processing software at the observing stations.

Redder, Chris↗

Are the World's Oceans Optically Different?

Regional differences in the Sea-viewing Wide Field-of-view Sensor chlorophyll algorithm uncertainty were observed in a large global data set containing coincident in situ measurements of chlorophyll a concentration (Chla) and spectral radiometry. The uncertainty was found to be systematic when the data were sorted by ocean: Atlantic, Pacific, Southern, and Indian Oceans. Artifacts associated with different instrumentation and analytical methods had been previously ruled out. Given these oceanic biases in the chlorophyll algorithm, we hypothesized that the oceans may be optically different, and their optical differences may be intrinsically related to regional differences in phytoplankton community structure or biogeochemical processes. The oceanic biases, originally observed using radiometric measurements, were independently verified using total absorption measurements in a subset of the data. Moreover, they were explained through oceanic differences in the absorption of colored detrital matter (CDM) and phytoplankton. Both effects were considered together in explaining the ocean biases through a stepwise linear regression analysis. Significant oceanic differences in the amount of CDM and in phytoplankton cell sizes and pigmentation would give rise to optical differences, but we raise a concern for the spatial coverage of the data. We do not suggest the application of ocean-based algorithms but rather emphasize the importance of consolidating regional data sets before reaching this conclusion.

Szeto, M.↗

Maximum likelihood estimation of difference scaling functions for suprathreshold judgments

Maximum likelihood estimation (MLE) has been used to produce perceptual scales from binary judgments of triads and quadruples. This method relies on Thurstone’s theory of a stochastic perceptual process where the perceived difference of two stimuli is the difference in their perceived strengths. It is possible that the perception of a suprathreshold difference is overestimated when adding smaller differences, a phenomenon referred to as diminishing returns. The current approach to construct a perceptual scale using MLE does not account for this phenomenon. We present a way to model the perception of differences using MLE and Thurstone’s theory, adapted to allow the possibility of diminishing returns. This method is validated using Monte Carlo simulated responses to experimental triads and can correctly model diminishing returns, the absence of diminishing returns, and the opposite of diminishing returns both in the cases when a perceptual scale is known and when the true perceived strengths of the stimuli are unknown. Additionally, this method was applied to empirical data sets to determine its feasibility in investigations of perception. Ultimately, it was found that this analysis allows for more accurate modeling of suprathreshold difference judgments, a more complete understanding of the perceptual processes underlying comparisons, and the evaluation of Thurstone’s theory of difference judgments.

97 MATHEMATICS AND COMPUTING↗

Sex Differences in Vagus Nerve Stimulation Effects on Rat Cardiovascular and Immune Systems

Background: Investigations into the benefits of vagus nerve stimulation (VNS) through pre-clinical and clinical research have led to promising findings for treating several disorders. Despite proven effectiveness of VNS on conditions such as epilepsy and depression, understanding of off-target effects and contributing factors such as sex differences can be beneficial to optimize therapy design. New Methods: In this article, we assessed longitudinal effects of VNS on cardiovascular and immune systems, and studied potential sex differences using a rat model of longterm VNS. Rats were implanted with cuff electrodes around the left cervical vagus nerve for VNS, and wireless physiological monitoring devices for continuous monitoring of cardiovascular system using electrocardiogram (ECG) signals. ECG morphology and heart rate variability (HRV) features were extracted to assess cardiovascular changes resulting from VNS in short-term and long-term timescales. We also assessed VNS effects on expression of inflammatory cytokines in blood during the course of the experiment. Statistical analysis was performed to compare results between Treatment and Sham groups, and between male and female animals from Treatment and Sham groups. Results: Considerable differences between male and female rats in cardiovascular effects of VNS were observed in multiple cardiovascular features. However, the effects seemed to be transient with approximately 1-h recovery after VNS. While short-term cardiovascular effects were mainly observed in male rats, females in general showed more significant long-term effects even after VNS stopped. We did not observe notable changes or sex differences in systemic cytokine levels resulting from VNS. Comparison With Existing Methods: Compared to existing methods, our study design incorporated wireless physiological monitoring and systemic blood cytokine level analysis, along with long-term VNS experiments in unanesthetized rats to study sex differences. Conclusion: The contribution of sex differences for long-term VNS off-target effects on cardiovascular and immune systems was assessed using awake behaving rats. Although VNS did not change the concentration of inflammatory biomarkers in systemic circulation for male and female rats, we observed significant differences in cardiovascular effects of VNS characterized using ECG morphology and HRV analyses.

59 BASIC BIOLOGICAL SCIENCES↗