Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effects of diffraction and static wavefront errors on high-contrast imaging from the Thirty Meter Telescope

High-contrast imaging, particularly direct detection of extrasolar planets, is a major science driver for the next generation of extremely large telescopes such as the segmented Thirty Meter Telescope. This goal requires more than merely diffraction-limited imaging, but also attention to residual scattered light from wavefront errors and diffraction effects at the contrast level of 10-8-10-9. Using a wave-optics simulation of adaptive optics and a diffraction suppression system we investigate diffraction from the segmentation geometry, intersegment gaps, obscuration by the secondary mirror and its supports. We find that the large obscurations pose a greater challenge than the much smaller segment gaps. In addition the impact of wavefront errors from the primary mirror, including segment alignment and figure errors, are analyzed. Segment-to-segment reflectivity variations and residual segment figure error will be the dominant error contributors from the primary mirror. Strategies to mitigate these errors are discussed.

segmented mirrors↗

Hybrid quantitative simulation on the in-line phase-contrast x-ray imaging of three dimensional samples under actual clinic imaging parameters

A hybrid model combining Monte Carlo method with diffraction theory of wave optics has been developed and applied to quantitatively simulate the in-line diffractive phase-contrast x-ray imaging of three dimensional tissue samples under actual clinic imaging parameters. The primary microcosmic interactions of medical-energy x-ray within matter including photoabsorption, Compton scattering, and coherent scattering, have been taken into account in the Monte Carlo simulation. A diffraction processing based on Fresnel diffraction theory is carried out to simulate the macroscopic diffraction effect. A comparison with experiment results has also been performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-cell phase contrast imaging at the nanoscale using Fresnel Coherent Diffractive Imaging Tomography

X-ray tomography can provide structural information of whole cells in close to their native state. Radiation-induced damage, however, imposes a practical limit to image resolution, and as such, a choice between damage, image contrast, and image resolution must be made. New coherent diffractive imaging techniques, such Fresnel Coherent Diffractive Imaging (FCDI), allows quantitative phase information with exceptional dose efficiency, high contrast, and nano-scale resolution. Here we present three-dimensional quantitative images of a whole eukaryotic cell by FCDI at a spatial resolution below 70 nm with sufficient phase contrast to distinguish major cellular components. From our data, we estimate that the minimum dose required for a similar resolution is close to that predicted by the Rose criterion, considerably below accepted estimates of the maximum dose a frozen-hydrated cell can tolerate. Based on the dose efficiency, contrast, and resolution achieved, we expect this technique will find immediate applications in tomographic cellular characterisation.

MICROSCOPY↗

Phase retrieval by coherent modulation imaging

Phase retrieval is a long-standing problem in imaging when only the intensity of the wavefield can be recorded. Coherent diffraction imaging (CDI) is a lensless technique that uses iterative algorithms to recover amplitude and phase contrast images from diffraction intensity data. For general samples, phase retrieval from a single diffraction pattern has been an algorithmic and experimental challenge. Here we report a method of phase retrieval that uses a known modulation of the sample exit-wave. This coherent modulation imaging (CMI) method removes inherent ambiguities of CDI and uses a reliable, rapidly converging iterative algorithm involving three planes. It works for extended samples, does not require tight support for convergence, and relaxes dynamic range requirements on the detector. CMI provides a robust method for imaging in materials and biological science, while its single-shot capability will benefit the investigation of dynamical processes with pulsed sources, such as X-ray free electron laser.

36 MATERIALS SCIENCE↗

Diffraction and imaging study of imperfections of crystallized lysozyme with coherent X-rays

Phase-contrast X-ray diffraction imaging and high-angular-resolution diffraction combined with phase-contrast radiographic imaging were employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in the symmetric Laue case. The full-width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal was approximately 16.7 arcsec and imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <1 1 0> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Inclusions of impurities or formations of foreign particles in the central growth region are resolved in the images with high sensitivity to defects. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in X-ray diffraction images. The details of the observed defects and the significant change in the revealed microstructures with drying provide insight into the nature of imperfections, nucleation and growth, and the properties of protein crystals.

Muramidase/chemistry↗

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗

Quantitative measurement of phase variation amplitude of ultrasonic diffraction grating based on diffraction spectral analysis

A new method based on diffraction spectral analysis is proposed for the quantitative measurement of the phase variation amplitude of an ultrasonic diffraction grating. For a traveling wave, the phase variation amplitude of the grating depends on the intensity of the zeroth- and first-order diffraction waves. By contrast, for a standing wave, this amplitude depends on the intensity of the zeroth-, first-, and second-order diffraction waves. The proposed method is verified experimentally. The measured phase variation amplitude ranges from 0 to 2π, with a relative error of approximately 5%. A nearly linear relation exists between the phase variation amplitude and driving voltage. Our proposed method can also be applied to ordinary sinusoidal phase grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Dislocation Characterization by Electron Channeling Contrast Imaging and Cross-Correlation Electron Backscattered Diffraction

The characterization and quantification of dislocations is predominately carried out using transmission electron microscopy (TEM). Nevertheless, the sample preparation necessary for TEM foils can be cumbersome and possibly introduce defects. Two other techniques for characterizing and quantifying dislocations are electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD). ECCI is similar to TEM in that specific imaging (channeling or diffraction) conditions need to be established, but is carried out in a scanning electron microscope on bulk samples, resulting in less complex sample preparation. CC-EBSD measures subtle changes in orientation measured from EBSD patterns to calculate elastic strains and the Nye tensor to deduce and map the total geometrically necessary dislocation (GND) content. Furthermore, this work presented here compares the capabilities of ECCI and CC-EBSD to map dislocations generated from nanoindentation.

42 ENGINEERING↗

Optimization of Crystals of an Inhibitory Antibody of Urokinase Plasminogen Activator Receptor (uPAR) with Hydrogen Peroxide and Low Protein Concentration

Optimization of protein crystal formation is often a necessary step leading to diffraction-quality crystals to enable collection of a full X-ray data set. Typical protein crystal optimization involves screening different components, e.g., pH, precipitants, and additives of the precipitant solution. Here we present an example using an inhibitory antibody of urokinase plasminogen activator receptor (uPAR) where such procedures did not yield diffracting crystals. In contrast, it was the treatment of the protein with hydrogen peroxide incubation and the protein concentration reduction that were found to be key factors in obtaining diffracting crystals. Final crystals diffracted to 1.75 {angstrom}, and belong to orthorhombic P212121 space group with unit cell parameters a = 37.162 {angstrom}, b = 84.474 {angstrom}, c = 134.030 {angstrom}, and contain one molecule of Fab fragment of anti-uro kinase receptor antibody in the asymmetric unit.

59 BASIC BIOLOGICAL SCIENCES↗

Diffraction and Imaging Study of Imperfections of Protein Crystals with Coherent X-rays

High angular-resolution x-ray diffraction and phase contrast x-ray imaging were combined to study defects and perfection of protein crystals. Imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of a uniformly grown lysozyme crystal. The observed line defects carry distinct dislocation features running approximately along the <110> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in diffraction images. X-ray imaging and diffraction characterization of the quality of apoferritin crystals will also be discussed in the presentation.

Hu, Z. W.↗

In-situ X-ray observations of ultrasound-induced explosive decomposition

High-strain mechanical loading of polymer-bonded explosives can produce significant stress concentrations due to microstructural heterogeneities, resulting in localized thermal “hot spots”. Ultrasound produces similar effects and has been proposed as a tool to study the thermomechanical interactions related to explosive initiation. Detailed observations of the processes governing the generation of heat in these materials are severely lacking, yet they are vital for identifying salient physics, improving the modeling tools used to predict mechanical response, improving explosives safety, and providing insight into the initiation mechanisms of explosion. Here we discuss high-speed, high-resolution in-situ observations, obtained via synchrotron X-ray phase contrast imaging and diffraction, of the heating and decomposition of an explosive material under ultrasonic excitation. We demonstrate that interfacial friction is a dominant heating mechanism and can yield violent reaction of explosive particles. Moreover, sub-surface particle temperatures are estimated via diffraction.

36 MATERIALS SCIENCE↗

Imaging and structure analysis of ferroelectric domains, domain walls, and vortices by scanning electron diffraction

Direct electron detectors in scanning transmission electron microscopy give unprecedented possibilities for structure analysis at the nanoscale. In electronic and quantum materials, this new capability gives access to, for example, emergent chiral structures and symmetry-breaking distortions that underpin functional properties. Quantifying nanoscale structural features with statistical significance, however, is complicated by the subtleties of dynamic diffraction and coexisting contrast mechanisms, which often results in a low signal-to-noise ratio and the superposition of multiple signals that are challenging to deconvolute. Here we apply scanning electron diffraction to explore local polar distortions in the uniaxial ferroelectric Er(Mn,Ti)O 3 . Using a custom-designed convolutional autoencoder with bespoke regularization, we demonstrate that subtle variations in the scattering signatures of ferroelectric domains, domain walls, and vortex textures can readily be disentangled with statistical significance and separated from extrinsic contributions due to, e.g., variations in specimen thickness or bending. The work demonstrates a pathway to quantitatively measure symmetry-breaking distortions across large areas, mapping structural changes at interfaces and topological structures with nanoscale spatial resolution.

36 MATERIALS SCIENCE↗

Multidimensional images and aberrations in STEM

Recent advances in scanning transmission electron microscopy (STEM) have led to increased development of multi-dimensional STEM imaging modalities and novel image reconstruction methods. This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens. This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images, such as ptychography and scanning nano-beam diffraction. However, the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance. Here, we examine this paradox by considering the effects of aberrations in both image and diffraction planes, and likewise separate the contributions of pre- and post-sample aberrations. In conclusion, this consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.

Hoglund, Eric R.↗

One-dimensional neutron diffraction from layered graphite: Reciprocal space structure and grating behavior

In this work we report observations of one-dimensional neutron diffraction from highly oriented pyrolytic graphite (HOPG), where the scattering angle varies continuously with incident angle following classical grating-like behavior. The 2D polycrystalline structure of HOPG—with highly aligned layers along the 𝑐 axis but random in-plane rotations—creates planes of scattering intensity in reciprocal space at 𝑄 𝑐 =𝑛⁢(2⁢𝜋/𝑑) where 𝑑=3.35Å is the interlayer spacing. As the Ewald sphere sweeps through reciprocal space during sample rotation, it continuously intersects these planes, producing the observed angular dispersion. We observe both first-order (𝑛=1) and second-order (𝑛=2) diffraction at conventional scattering angles (25°–70°), with peak positions that remain temperature-independent between 10 K and 294 K and follow quantitative agreement with momentum conservation 𝑄 𝑐 =𝑘⁢[sin⁡𝜓−sin⁡𝜓 𝑓 ]=𝑛⁢(2⁢𝜋/𝑑). X-ray diffraction under similar conditions shows no comparable behavior, confirming that sharp nuclear-vacuum contrast is essential. While diffraction intensities are weak (∼10 −6 of Bragg peaks), the observations demonstrate how the interplay of atomic-scale periodicity, nuclear contrast, and structural disorder enables observation of continuous diffraction curves at thermal neutron wavelengths, illustrating how HOPG's unique microstructure determines its scattering properties beyond conventional Bragg diffraction.

2-dimensional systems↗

Nanoscale conditions for ductile void nucleation in copper: vacancy condensation and the growth-limited microstructural state

Ductile rupture or tearing usually involves structural degradation from the nucleation and growth of voids and their coalescence into cracks. Although some materials contain preexisting pores, the first step in failure is often the formation of voids. Because this step can govern both the failure strain and the fracture mechanism, it is critical to understand the mechanisms of void nucleation and the enabling microstructural configurations which give rise to nucleation. To understand the role of dislocations during void nucleation, the present study presents ex-situ cross-sectional observations of interrupted deformation experiments revealing incipient, subsurface voids in a copper material containing copper oxide inclusions. The local microstructural state was evaluated using electron backscatter diffraction (EBSD), electron channeling contrast (ECC), transmission electron microscopy (TEM), and transmission kikuchi diffraction (TKD). Surprisingly, before substantial growth and coalescence had occurred, the deformation process had resulted in the nucleation of a high density of nanoscale (≈50 μm) voids in the deeply deformed neck region where strains were on the order of 1.5. Such a proliferation of nucleation sites immediately suggests that the rupture process is limited by void growth, not nucleation. With regard to void growth, analysis of more than 20 microscale voids suggests that dislocation boundaries facilitate the growth process. The present observations call into question prior assumptions on the role of dislocation pile-ups and provide new context for the formulation of revised ductile rupture models. While the focus of this study is on damage accumulation in a highly ductile metal containing small, well-dispersed particles, these results are also applicable to understanding void nucleation in engineering alloys.

36 MATERIALS SCIENCE↗

Influence of Polarization Setting on Gold Nanorod Signal at Nonplasmonic Wavelengths Under Differential Interference Contrast Microscopy

Researchers rely on a variety of microscopic techniques for observing and tracking anisotropic nanoparticles in real time experiments. This technical note focuses on the optical behavior exhibited by gold nanorods at nonplasmonic wavelengths under differential interference contrast microscopy (DIC). Intense diffraction patterns appear at nonplasmonic wavelengths, and the behavior of these patterns can be altered by adjusting the surrounding medium or the polarizer setting. Such patterns are absent when linear and crossed polarizations are utilized. Making polarization adjustments is important in DIC microscopy, because it affects bias retardation and image contrast. The nonplasmonic diffraction bands that were observed could potentially be exploited for rotational tracking, but more importantly, researchers should exhibit care in selecting a nanorod sample and the polarization setting when working with DIC microscopy.

36 MATERIALS SCIENCE↗