Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital Image correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures. Dog bone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. Acoustic emission (AE) data were also continuously acquired throughout the loading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The damage progression was analyzed based on the results from these three techniques. The results for both architectures and test specimens followed a pattern where matrix cracks formed at the surface perpendicular to the tensile load direction. New surface cracks formed continuously throughout the loading and cracks extended in depth and width. In general, fiber failure was not detected until specimen failure.

Wade C Jackson↗

Analysis of a Dynamic Flexed Flat Cable Harness

A dynamic flex test was performed on a spacecraft instrument harness composed of multiple individual flex cables, with each flex cable containing multiple copper traces. The purpose of the test was to demonstrate the capability of the harness to survive the number of expected flex cycles during the planned mission with appropriate margin. However, during testing, increased trace resistances and open circuits were observed beginning at approximately 10% of the total number of planned flex cycles. This paper discusses the various proximate causes that contributed to increased and open resistance in the flex cables and the subsequent redesign, manufacturing, reliability, and quality-related changes that were instituted. An analysis process, including failure analysis, non-destructive evaluation, digital imaging correlation, and parametric modeling, will also be discussed. The paper will cover the development of a robust dynamic flex harness design and include recommendations to extend flex harness life; make changes to the flex harness life test; and improve flex cable manufacturing, quality, and reliability.

Flexible PCB↗

Finite Element Analysis Validation for Stitched, Blade-Stiffened Aerospace Structures

Increased performance and manufacturing rates for aircraft or spacecraft structures may be achieved using stitched and resin infused composite structures. In order to carry out design and analysis of stitched composites, 2-dimensional (2-D) and 3-dimensional (3-D) modeling approaches for stitched and non-stitched carbon fiber vacuum-infused parts were developed. These analysis approaches will be compared with data from previous test specimens tested at the NASA Langley Research Center (LaRC) under tension and bending load conditions. The preliminary results presented herein for the 2-D and 3-D models capture the strain patterns observed in digital image correlation (DIC) data for stitched, blade-stiffened specimens tested in either tension or bending. The analysis method study presented for these specimens is part of a larger analysis development effort planned for stitched composites, with the modeling practices developed here contributing to those that may be applied to a new set of blade- stiffened test specimens that are currently being manufactured for testing as well as the design of a blade stringer pull-off test. These future tests are expected to provide opportunities to validate the developed modeling approaches for predictive purposes, and to provide opportunities for further refinement of the modeling approaches.

HiCAM↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures loaded in the warp direction. Dogbone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure, and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The results for both architectures and test specimens followed a similar pattern where matrix cracks formed perpendicular to the load direction and were primarily located between the stacks of warp tows. Two-piece failure path always occurred perpendicular to the loading direction, along the through-thickness segments of the Z-tows. The combination of stress concentrations due to the specimen geometry, weave geometry, and cut tows created stress concentrations that appear to initiate failure.

Woven materials↗

Analysis of a Dynamic Flexed Flat Cable Harness

A dynamic flex test was performed on a spacecraft instrument harness composed of multiple individual flex cables, with each flex cable containing multiple copper traces. The purpose of the test was to demonstrate the capability of the harness to survive the number of expected flex cycles during the planned mission with appropriate margin. However, during testing, increased trace resistances and open circuits were observed beginning at approximately 10% of the total number of planned flex cycles. This paper discusses the various proximate causes that contributed to increased and open resistance in the flex cables and the subsequent redesign, manufacturing, reliability, and quality-related changes that were instituted. An analysis process, including failure analysis, non-destructive evaluation, digital imaging correlation, and parametric modeling, will also be discussed. The paper will cover the development of a robust dynamic flex harness design and include recommendations to extend flex harness life; make changes to the flex harness life test; and improve flex cable manufacturing, quality, and reliability.

Flexible PCB↗

In-situ Testing to Acquire HR-EBSD and DIC Strain Data Within a Coincident Domain

For this project, an inked rubber stamp was applied to a small Inconel 625 specimen. The stamp transferred a thin pattern with microscale features for digital image correlation (DIC). The pattern is easily visible at lower voltages and thin enough to not obstruct backscattered electrons. The unique characteristics of the pattern enabled the concurrent acquisition of DIC and high-resolution electron backscatter diffraction (HR-EBSD) data while the specimen was loaded in-situ. The challenges of in-situ testing and combining EBSD with DIC measurements are discussed. By combining the elastic strains (from HR-EBSD) and total strains (from DIC) the result of this approach is an estimate of stress- strain behavior at points across the specimen surface. This combined dataset can then be used as higher-fidelity data in the calibration of crystal plasticity models.

Will Gilliland↗

Effects of Cooling Holes on SiC/SiC Strength and Durability

Ceramic Matrix Composites (CMCs) such as SiC/SiC are currently operating in select high temperature components of turbine engines. When these materials are implemented in components at higher operating temperatures, film cooling may be necessary. Film cooling requires holes to be fabricated at appropriate locations within these components. This study examines the effect of cooling holes on SiC/SiC composite strength and durability. Mechanical test data on specimens with multiple holes is reported for isothermal conditions at room and elevated temperatures. Tools such as Digital Image Correlation (DIC) and Acoustic Emission (AE) are used to monitor strain and cracking upon loading.

Ceramic matrix composite↗

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗

Impact Ice Adhesion at NASA Glenn: Current Experimental Methods and Supporting Measurements

When examining the literature on the adhesion strength of impact ice, there have been a wide range of methodologies tried to measure the required stresses to induce interfacial delamination. Utilizing the Icing Research Tunnel at the NASA Glenn Research Center to generate the impact ice required for this work, several different mechanical tests have been and are being developed to determine the stresses along the interface between ice and coupon. This set of tests includes the technical mature modified lap joint test which has been used to conduct ice adhesion studies through a wide sweep of icing conditions. To conduct in situ ice adhesion measurements inside of the Icing Research Tunnel, several new experiments are currently being developed to make ice adhesion measurements during and immediately after ice accretion. In addition to these experimental methods, several supporting measurement techniques have been developed to allow for a better understanding on the influence of icing cloud conditions on the mechanical behavior of impact ice. Digital image correlation has been successfully implemented to augment the data generated by the modified lap joint test with full field surface displacement and strain measurements which allow for insight into the deformation processes present during a test. Both optical microscopy of impact ice samples along with ice replication techniques have been used to study the grain structure of the impact ice. This has led to a deeper understanding of the results from the modified lap joint method and how the structure of impact ice changes as it is accreted during an icing spray. The freezing process of impact ice generated by supercooled liquid water is not a volume conserving process, which leads to the presence of residual strains along the interface between ice and substrate. These strains have been observed using both a simplified flat geometry and a representative airfoil. The data gathered by these experimental adhesion methods and supporting measurements allows for a comprehensive understanding on the behavior of impact ice which will be critical to the development of future ice shedding models.

Ice Adhesion↗

Results from Two Full-Scale Hawker 4000 Fuselage Drop Tests

In the spring of 2022, NASA Langley Research Center (LaRC) conducted two full-scale drop tests on a Hawker 4000 partial fuselage structure for the evaluation of composite material response under dynamic impact loading conditions. The specific objectives of the tests were to induce dynamic composite damage initiation and progression and in primary structure and to understand the nature of the failure modes. The tests were conducted via dividing the fuselage hardware into three smaller sections. Dynamic drop tests were conducted on the forward and aft portions of the fuselage under different dynamic loading conditions, while the middle section was reserved for materials testing. Both tests were conducted by dropping the test articles from a height of 14 feet with significant amounts of pitch, which was added to initiate damage in specific regions of the structure. The test articles were ballasted then instrumented with accelerometers at various locations and speckle-coated on both exterior sides with a black and white stochastic pattern for use with three-dimensional digital image correlation (3D-DIC). In addition, the interior belly portion of the forward section test article was also speckle-coated, which was intended to capture deformations on the belly of the test article from the interior at impact. The interior of the aft section test article was not speckle-coated. Prior to testing, bow-tie markers were applied at various locations for use in marker tracking, to measure impact conditions such as vertical impact velocity and pitch. In this report, a partial summary of the data collected from the tests is presented. The data was primarily in the form of accelerometers to measure impact acceleration and 3D-DIC to measure deformation and failure onset and propagation. Post-test inspections revealed the primary damage mechanism was fiber cracking and delamination primarily in and around the area that contacted the impact surface. Acceleration pulse shapesin the ballast locations were trapezoidal in nature and ranged between 10 g and 40 g, depending on the location and test.

full scale testing↗

Impact Ice Adhesion at NASA Glenn: Current Experimental Methods and Supporting Measurements

When examining the literature on the adhesion strength of impact ice, there have been a wide range of methodologies tried to measure the required stresses to induce interfacial delamination. Utilizing the Icing Research Tunnel at the NASA Glenn Research Center to generate the impact ice required for this work, several different mechanical tests have been and are being developed to determine the stresses along the interface between ice and coupon. This set of tests includes the technical mature modified lap joint test which has been used to conduct ice adhesion studies through a wide sweep of icing conditions. To conduct in situ ice adhesion measurements inside of the Icing Research Tunnel, several new experiments are currently being developed to make ice adhesion measurements during and immediately after ice accretion. In addition to these experimental methods, several supporting measurement techniques have been developed to allow for a better understanding on the influence of icing cloud conditions on the mechanical behavior of impact ice. Digital image correlation has been successfully implemented to augment the data generated by the modified lap joint test with full field surface displacement and strain measurements which allow for insight into the deformation processes present during a test. Both optical microscopy of impact ice samples along with ice replication techniques have been used to study the grain structure of the impact ice. This has led to a deeper understanding of the results from the modified lap join method and how the structure of impact ice changes as it is accreted during an icing spray. The freezing process of impact ice generated by supercooled liquid water is not a volume conserving process, which leads to the presence of residual strains along the interface between ice and substrate. These strains have been observed using both a simplified flat geometry and a representative airfoil. The data gathered by these experimental adhesion methods and supporting measurements allows for a compressive understanding on the behavior of impact ice which will be critical to the development of future ice shedding models.

Ice Adhesion↗

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗

Results from Two Full-Scale Hawker 4000 Fuselage Drop Tests

In the spring of 2022, NASA Langley Research Center (LaRC) conducted two full-scale drop tests on a Hawker 4000 partial fuselage structure for the evaluation of composite material response under dynamic impact loading conditions. The specific objectives of the tests were to induce dynamic composite damage initiation and progression and in primary structure and to understand the nature of the failure modes. The tests were conducted via dividing the fuselage hardware into three smaller sections. Dynamic drop tests were conducted on the forward and aft portions of the fuselage under different dynamic loading conditions, while the middle section was reserved for materials testing. Both tests were conducted by dropping the test articles from a height of 14 feet with significant amounts of pitch, which was added to initiate damage in specific regions of the structure. The test articles were ballasted then instrumented with accelerometers at various locations and speckle-coated on both exterior sides with a black and white stochastic pattern for use with three-dimensional digital image correlation (3D-DIC). In addition, the interior belly portion of the forward section test article was also speckle-coated, which was intended to capture deformations on the belly of the test article from the interior at impact. The interior of the aft section test article was not speckle-coated. Prior to testing, bow-tie markers were applied at various locations for use in marker tracking, to measure impact conditions such as vertical impact velocity and pitch. In this report, a partial summary of the data collected from the tests is presented. The data was primarily in the form of accelerometers to measure impact acceleration and 3D-DIC to measure deformation and failure onset and propagation. Post-test inspections revealed the primary damage mechanism was fiber cracking and delamination primarily in and around the area that contacted the impact surface. Acceleration pulse shapesin the ballast locations were trapezoidal in nature and ranged between 10 g and 40 g, depending on the location and test.

full scale testing↗

Impact Forces From Artificial and Real Birds on a Large Diameter Hopkinson Bar

Forces were measured from normal impacts with two different artificial bird recipes and two species of real birds on a very rigid flat surface. The tests were conducted by launching the soft body projectiles axially into a Hopkinson bar in accordance with the SAE AS6940 test standard at three different nominal impact conditions: (a) a 1 kg projectile at an impact velocity of 49 m/sec; (b) a 1.8 kg projectile at an impact velocity of 110 m/sec; and (c) a 1.8 kg projectile at an impact velocity of 310 m/sec. At each condition two artificial birds and one real bird projectile were tested with at least three test repeats. Simulations were conducted to assess the effects of projectile orientation and velocity on predicted forces. The Hopkinson bar consisted of an Aluminum 6061 solid cylindrical bar with a diameter of 305 mm and a length of 7.31 m, made up of two 3.66 m long sections that were in axial contact with each other. The bar was instrumented for strain measurement at two locations, 457.2 mm and 609.6 mm (1.5 and 2 diameters) from the impacted face. Forces were calculated from the measured strain. In addition, digital image correlation (DIC) was used to measure the velocity of the free end of the bar. The real bird projectiles were 1 kg Mallard ducks and 1.8 kg Golden Comet chickens that were prepared per ASTM F330-21. Prior to testing, the real birds were placed in muslin bags to minimize tumbling during flight. Two artificial bird formulations were tested, one produced by the University of Dayton Research Institute (UDRI) and the other by the German Aerospace Center, DLR. The UDRI projectile was a homogeneous, relatively soft solid, formulated with a mixture of water, gelatin and phenolic micro-balloons to achieve a nominal density of 0.95 g/cc. The DLR projectile consisted of a printed plastic shell with internal plastic ribs and filled with a gel material. The projectiles were designed such that the overall average density was the desired value of 0.95 g/cc. Initial testing showed that contact between the two Hopkinson bar segments was not sufficient to allow full transmission of the waves through the interface. For the 49 m/sec and 110 m/sec tests this resulted in reflections returning to the strain measurement site prior to the end of the impact. For these tests only a portion of the force pulse could be accurately measured. For the highest velocity tests at 310 m/sec the force pulse was complete by the time reflected waves interfered with the response. Despite this limitation, useful force data were obtained for all velocities. Impact forces were very sensitive to the impact orientation and velocity. The force history generally consisted of an initial region with varying amplitude followed by a relatively constant amplitude response. The steady state region was similar among all projectiles and similar to what would be predicted for an inviscid fluid with a density of 0.95 g/cc. The initial part of the force response exhibited varying degrees of test-to-test repeatability associated with each projectile type. Forces calculated from DIC velocity measurements of the free end of the bar compared favorably those from the strain measurements. In general, the artificial projectile impact forces were quite repeatable from test to test, with some exceptions which could be explained by issues associated with either the projectile itself or with how the projectile exited the gun barrel. For all impact velocities the initial portion of the impact force from the bird projectiles exhibited large test-to-test variability. In this paper, impact forces for three types of projectiles at three impact velocities will be presented with an emphasis on the test-to-test repeatability of the results. Based on test and simulation results a proposed method for normalizing the impact force to minimize effects of differences in projectile orientation, impact velocity and density will also be discussed.

Bird strike↗

High-Temperature Mechanical Tensile Testing of Unidirectional Sic/Sic Composites Using A Versatile Lamp Furnace

Silicon carbide (SiC) based ceramic matrix composites (CMCs) are of interest for high-temperature structural applications, including use in turbine engine components. To understand damage mechanisms and predict durability of these systems, in-depth knowledge of their behavior at ambient and high temperatures is necessary. A method for high temperature testing of SiC/SiC minicomposite specimens up to 1500oC in both tensile fast fracture and creep conditions to investigate their thermomechanical behavior will be presented. This method utilizes a novel radiation heat furnace, equipped with infrared lamps with ellipsoidal reflectors, to heat the specimen at the furnace center in user-defined atmospheres. The housing structure of the lamps allows for observation of the specimen during testing using optical methods and for conducting other experimental studies. The goal is to employ nondestructive health monitoring techniques in-situ, including acoustic emission (AE), electrical resistance (ER), and digital image correlation (DIC) to evaluate damage initiation and evolution in the minicomposite specimens during tensile testing. Results from mechanical testing and nondestructive techniques will be presented. Electron microscopy and X-ray micro-computed tomography were used to further characterize specimen damage after testing.

Aeronautics↗

High-Cycle Fatigue Behavior of SiC-based Ceramic Matrix Composites (CMCs) at High Temperatures

High-cycle fatigue (HCF) behavior of a melt-infiltrated, pre-preg SiC/SiC ceramic matrix composite (CMC) was investigated using dogbone tensile specimens without and with simulated cooling holes at 1500 and 2400 °F. The CMC material used for this study was fabricated by GE Aviation and had a ply configuration of [0/90/0]3. HCF tests were conducted with an R-ratio of 0.6 and a cyclic frequency of 30 Hz. Runout in HCF was defined as 30 million cycles. Monotonic tensile tests were conducted at room temperature (RT) on as-received CMC specimens and on runout HCF specimens to determine residual tensile strengths. Digital image correlation (DIC) and acoustic emission (AE) techniques were used to monitor the initiation and progression of damage in RT tensile tests on specimens with and without holes. Microscopy was performed on the polished edge of specimens without cooling holes and on the polished face of specimens with cooling holes that were tested in HCF and achieved runout. Comparisons were made with baseline specimens. Fractography was performed to examine the fracture surfaces of samples that failed under different loading conditions.

Ceramic Matrix Composites↗

Tensile Behavior and High-Cycle Fatigue Durability of a SiC/SiC Ceramic-Matrix Composite Without and With Simulated Cooling Holes

High-cycle fatigue (HCF) behavior of a melt-infiltrated, prepreg SiC/SiC composite was investigated using specimens without and with simulated cooling holes at 816 and 1,316 °C. The ceramic-matrix composite (CMC) material used for this study was fabricated by GE Aviation and had a ply configuration of [0/90/0] 3 . HCF tests were conducted with an R-ratio of 0.6 and a cyclic frequency of 30 Hz. Maximum tensile gross-section stresses used in the HCF tests ranged from 152 to 359 MPa. Runout in HCF was defined as 30 million cycles (278 h) at both temperatures. Monotonic tensile tests were conducted at room temperature (RT) on as-received CMC specimens and on HCF runout specimens without and with holes to determine residual tensile strengths. Digital image correlation (DIC) and acoustic emission (AE) techniques were used to monitor progression of damage in RT tensile tests on specimens without and with holes. Fractography was performed on a limited number of specimens without and with holes to determine morphology of fracture surfaces. Representative RT stress-strain behavior, elevated temperature HCF behavior at the two temperatures, and RT residual tensile strengths of HCF runout specimens are documented in this report. Select examples of DIC and AE data from RT tensile tests on specimens without and with holes and typical features observed on fracture surfaces of specimens tested under tensile and HCF conditions are also discussed.

Ceramic matrix composite↗

Experimental Characterization of Non-Associative Plasticity Flow Rule Coefficients and Post-Peak Stress Degradation for the LS-DYNA MAT213 Model

This project is focused on developing an experimental framework for characterizing non-associative plasticity flow rule coefficients through coupon-scale tests for the LS-DYNA MAT213 model. The main objective is to characterize these coefficients based on the multi-scale (i.e., both microscopic and macroscopic) full-field measurement of the evolution of strain and stress fields. This paper focuses on presenting the experimental work on characterizing the full-scale stress-strain curves of T700/LM-PAEK composites under tension, compression, and shear loads. The experimental data set was intended to build a deformation sub-model in the MAT213 model for the material. The strain data were collected using both microscopic and macroscopic digital image correlation techniques. The microscopic technique was particularly useful for fracture cases under small strains. A preliminary simulation result obtained from the MAT213 model is also presented in the paper. The experimental framework herein will be extended to characterize post-peak stress degradation in the composite material and to develop a damage sub-model for the material. This project will contribute to developing a simulation tool based on the MAT213 model for simulating the rate-dependent impact damage in composites under multi-axial loading.

MAT213↗