Search NASA⌕ Search

SEARCH · Search NASA

Results for “distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Radar Autofocus Algorithm Incorporating a priori Terrain Knowledge for Correction of Mars’ Ionospheric Distortion in MARSIS Observations

Low-frequency subsurface radar observations of Mars’ polar ice deposits by MARSIS (Mars Advanced Radar for Subsurface and Ionosphere Sounding) are heavily impacted by the electron content of Mars’ ionosphere. The resulting ionospheric distortion can be represented as attenuation and bulk delay, in addition to higher-order frequency dispersion effects. Baseline, uncorrected images are often unusable when the solar zenith angle is less than 90◦ (day side). In this work, a radar autofocus algorithm is developed that estimates and inverts ionospheric distortion, producing a focused radargram of the ice deposit subsurface. Previously published autofocus algorithms have sought to maximize peak-to-noise contrast, which may yield sub-optimal results for complex terrain. Instead, a maximum likelihood approach is developed that incorporates simulated surface clutter returns for the current spacecraft position, based on the Mars Orbiter Laser Altimeter (MOLA) elevation model of the Martian surface. An ancillary product is a surface-only clutter simulation for each orbit, which is necessary to identify true subsurface features.

McMichael, Joseph G.↗

Calibration of the ProtoDUNE Horizontal-Drift position reconstruction using a laser system

Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coulomb corrections in quasi-elastic scattering: Tests of the effective-momentum approximation

Coulomb corrections for quasielastic scattering of electrons by nuclei are calculated using eikonal distorted waves. Corrections to the lowest-order eikonal approximation are included to obtain accurate results. Spin-dependent eikonal phase shifts are evaluated and they yield very small corrections to the longitudinal and transverse cross sections at electron energies of 500 MeV or higher. Because of this the Rosenbluth procedure is accurate for separation of the longitudinal and transverse response functions. The effective-momentum approximation is also found to be accurate with regard to removal of the remaining Coulomb effects from the distorted waves. Calculations are presented for electron scattering from {sup 208}Pb and {sup 56}Fe nuclei at energies of 500 and 800 MeV and momentum transfers q=550 and 900 MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SOFT-1: Imaging Processing Software

Five levels of image processing software are enumerated and discussed: (1) logging and formatting; (2) radiometric correction; (3) correction for geometric camera distortion; (4) geometric/navigational corrections; and (5) general software tools. Specific concerns about access to and analysis of digital imaging data within the Planetary Data System are listed.

Source record↗

Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom

Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through-plane direction and an increased blurring of capsule images, resulting in an apparent capsule volume increase by up to 170% in extreme axial FOV regions. Blurring increased with table speed and in the central regions of the phantom, geometric distortion was less for static table acquisitions compared to a table speed of 2 mm/s over the same volume. Overall, the best geometric accuracy was achieved with a table speed of 1.1 mm/s. Conclusions: The phantom designed enables full FOV imaging for distortion assessment for the purposes of RTP. MRI acquisition with a moving table extends the imaging volume in the z direction with reduced distortions which could be useful particularly if considering MR-only planning. If utilizing MR images to provide additional soft tissue information to the planning CT, standard acquisition sequences over a smaller volume would avoid introducing additional blurring or distortions from the through-plane table movement.

60 APPLIED LIFE SCIENCES↗

Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal imaging routines including different standard MRI sequences.

60 APPLIED LIFE SCIENCES↗

Three dimensional imaging and analysis of a single nano-device at the ultimate scale using correlative microscopy techniques

The analysis of a same sample using nanometre or atomic-scale techniques is fundamental to fully understand device properties. This is especially true for the dopant distribution within last generation nano-transistors such as MOSFET or FINFETs. In this work, the spatial distribution of boron in a nano-transistor at the atomic scale has been investigated using a correlative approach combining electron and atom probe tomography. The distortions present in the reconstructed volume using atom probe tomography have been discussed by simulations of surface atoms using a cylindrical symmetry taking into account the evaporation fields. Electron tomography combined with correction of atomic density was used so that to correct image distortions observed in atom probe tomography reconstructions. These corrected atom probe tomography reconstructions then enable a detailed boron doping analysis of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamically constrained correction to ab initio equations of state

We show how equations of state generated by density functional theory methods can be augmented to match experimental data without distorting the correct behavior in the high- and low-density limits. The technique is thermodynamically consistent and relies on knowledge of the density and bulk modulus at a reference state and an estimation of the critical density of the liquid phase. We apply the method to four materials representing different classes of solids: carbon, molybdenum, lithium, and lithium fluoride. It is demonstrated that the corrected equations of state for both the liquid and solid phases show a significantly reduced dependence of the exchange-correlation functional used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave holography of large reflector antennas - Simulation algorithms

The performance of large reflector antennas can be improved by identifying the location and amount of their surface distortions and correcting them. To determine the accuracy of the constructed surface profiles, simulation studies are used to incorporate both the effects of systematic and random distortions, particularly the effects of the displaced surface panels. In this paper, different simulation models are investigated, emphasizing a model based on the vector diffraction analysis of a curved reflector with displaced panels. The simulated far-field patterns are then used to reconstruct the location and amount of displacement of the surface panels by employing a fast Fourier transform/iterative procedure. The sensitivity of the microwave holography technique based on the number of far-field sampled points, level of distortions, polarizations, illumination tapers, etc., is also examined.

Rahmat-Samii, Y.↗

Application of a recursive distortion estimator to the geodetic correction of thematic mapper imagery

It is pointed out that the higher resolution provided by the Thematic Mapper increases the demands on the accuracy needed by the ground processing in correcting for geodetic errors deriving from internal misalignments and uncertainties in the knowledge of spacecraft ephemeris and attitude. In addition, the Thematic Mapper will also process longer imagery intervals than previous missions. The recursive distortion estimator to be used is a Kalman filter. Here, a minimum variance spacecraft state error vector is estimated for known initial covariance of the elements of that vector and known image noise. Tests of the recursive distortion estimator with various spacecraft models carried out using a simulation of real world state vector dynamics are described. A determination is made of the density of control points needed to meet specified geometric correction requirements; it is expressed as a function of imagery interval length and control point measurement error.

Arnold, P.↗

A CONVENIENT SOLUTION TO GEOMETRIC DISTORTION AND ITS APPLICATION TO PHOEBE'S OBSERVATIONS

A simple but effective approach is proposed for measuring the geometric distortion of a CCD field of view of a ground-based telescope. For three open clusters (M35, M67, and NGC 2324), 425 CCD frames taken by a 1 m telescope at the Yunnan Observatory are used to test this approach. It is found that the geometric distortion pattern depends strongly on the corresponding filter used. The geometric distortion is then used to correct the pixel positions for Phoebe, the ninth satellite of Saturn, and its reference stars imaged in 220 CCD frames taken by the same telescope. The standard deviation of the (O - C; observed minus computed) residuals of Phoebe is significantly improved after correcting the geometric distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Echelle spectra image processing for the International Ultraviolet Explorer

This paper presents the techniques needed to convert the International Ultraviolet Explorer (IUE) high-resolution echelle spectra into useful scientific data. The image is obtained with a digitally controlled vidicon camera system. The processes that must be carried out on the image include: noise removal, correction for geometric and optical distortion, nonuniform photometric corrections, and two-dimensional wavelength determination. Results from the breadboard camera system are presented.

Klinglesmith, D. A.↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

In vivo volumetric imaging of calcium and glutamate activity at synapses with high spatiotemporal resolution

Studying neuronal activity at synapses requires high spatiotemporal resolution. For high spatial resolution in vivo imaging at depth, adaptive optics (AO) is required to correct sample-induced aberrations. To improve temporal resolution, Bessel focus has been combined with two-photon fluorescence microscopy (2PFM) for fast volumetric imaging at subcellular lateral resolution. To achieve both high-spatial and high-temporal resolution at depth, we develop an efficient AO method that corrects the distorted wavefront of Bessel focus at the objective focal plane and recovers diffraction-limited imaging performance. Applying AO Bessel focus scanning 2PFM to volumetric imaging of zebrafish larval and mouse brains down to 500 µm depth, we demonstrate substantial improvements in the sensitivity and resolution of structural and functional measurements of synapses in vivo. This enables volumetric measurements of synaptic calcium and glutamate activity at high accuracy, including the simultaneous recording of glutamate activity of apical and basal dendritic spines in the mouse cortex.

59 BASIC BIOLOGICAL SCIENCES↗