Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.4)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is responsible for coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, and teams. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF procedures. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.5)

This document specifies an interface to support the parallel features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a proposed solution in which the runtime library is primarily responsible for implementing coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, teams and collective subroutines. In this interface, the compiler is responsible for transforming the invocation of Fortran-level parallel features into procedure calls to the necessary PRIF subroutines. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Parallel Runtime Interface for Fortran (PRIF) Specification (Rev. 0.6)

This document specifies an interface to support the multi-image parallelism features of Fortran, named the Parallel Runtime Interface for Fortran (PRIF). PRIF is a solution in which a runtime library is primarily responsible for implementing coarray allocation, deallocation and accesses, image synchronization, atomic operations, events, teams and collective subroutines. The Fortran compiler is responsible for transforming the invocation of Fortran-level multi-image parallelism features into procedure calls to the necessary PRIF subroutines. The interface is designed for portability across shared- and distributed-memory machines, different operating systems, and multiple architectures. Implementations of this interface are intended as an augmentation for the compiler's own runtime library. With an implementation-agnostic interface, alternative parallel runtime libraries may be developed that support the same interface. One benefit of this approach is the ability to vary the communication substrate. A central aim of this document is to define a parallel runtime interface in standard Fortran syntax, which enables us to leverage Fortran to succinctly express various properties of the procedure interfaces, including argument attributes.

97 MATHEMATICS AND COMPUTING↗

Quench protection for high-temperature superconductor cables using active control of current distribution

Superconducting magnets of future fusion reactors are expected to rely on composite high-temperature superconductor (HTS) cable conductors. In presently used HTS cables, current sharing between components is limited due to poorly defined contact resistances between superconducting tapes or by design. The interplay between contact and termination resistances is the defining factor for power dissipation in these cables and ultimately defines their safe operational margins. However, the current distribution between components along the composite conductor and inside its terminations is a priori unknown, and presently, no means are available to actively tune current flow distribution in real-time to improve margins of quench protection. Also, the lack of ability to electrically probe individual components makes it impossible to identify conductor damage locations within the cable. In this work, we address both problems by introducing active current control of current distribution between components using cryogenically operated metal-oxide-semiconductor-field-effect transistors (MOSFETs). We demonstrate through simulation and experiments how real-time current controls can help to drastically reduce heat dissipation in a developing hot spot in a two-conductor model system and help identify critical current degradation of individual cable components. Finally, prospects of other potential uses of MOSFET devices for improved voltage detection, AC loss-driven active quench protection, and remnant magnetization reduction in HTS magnets are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distributed Coordination of Demand-side Flexible Resources in Microgrid with All-Time Feasibility

The prevalence of distributed renewable generators motivates microgrid operators to exploit demand-side flexible resources (DFRs). Due to their dispersed nature, distributed DFR coordination has been a vibrant research area, while there are several issues awaiting to be addressed. On one hand, DFR power is internally coupled through power flow, while DFR usually cannot access grid information. On the other hand, in time-restricted scenarios, solution feasibility cannot be guaranteed by conventional dual-based algorithms. To fill these gaps, we propose a distributed DFR coordination framework with all-time feasibility. The proposed framework accounts for the distinct access of microgrid entities to grid information. A distributed and all-time feasible algorithm is proposed for optimal DFR coordination, which allows DFRs to make local decisions without violating constraints throughout iterations. The effectiveness of the proposed algorithm is demonstrated through case studies. The impact of peer-to-peer communication links on algorithm convergence is also investigated, which emphasizes the balance between communication investment and algorithm performance.

Li, Hongyi [Iowa State Univ., Ames, IA (United Sta↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

A Measurement-Based Adaptive Voltage Regulation Method Considering Topology Changes

This paper proposes an online adaptive data-driven distributed energy resource (DER) dispatch optimization method for voltage control considering topology changes. By using a local sensitivity factor (LSF)-enabled voltage control, traditional DER control can be reformulated into a linear programming (LP) problem, leading to faster computation speeds. Power injection alteration and topology changes are two common operational changes in the distribution network that can affect the LSF and voltage control performance. To address this issue, a robust estimation method is developed to adjust the sensitivity matrix at each time step for the time-varying power injection changes. When topology changes occur, only the allocated predominant LSF submatrices are updated based on measurement data, allowing for a fast adaptation to the system reconfiguration. Results obtained from a real distribution feeder in Southern California demonstrate its robustness as compared to traditional volt-var control and constant LSF matrix dispatch control methods.

DERs↗

A Scalable, Distribution Network-Aware, Customer Privacy-Preserving Framework for Operation of Virtual Power Plants

This poster presents a hierarchical control framework for a virtual power plant that leverages behind-the-meter resources for grid services while maintaining customer privacy during setpoint disaggregation. Unlike many existing approaches, the virtual power plant model uses a hierarchical control strategy and an iterative approach to determine the optimal set point dis-aggregation without direct load control while maintaining system-level power flow and voltage constraints. The proposed approach is numerically validated on a synthetic distribution feeder in San Francisco, demonstrating the ability of the framework to provide privacy-preserving virtual power plant services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

Flexible Operation of Natural Gas Power Plants in Texas: Startup and Shutdown Durations and Nitrogen Dioxide Emissions

This dataset provides insights into historical flexible operation of natural gas power plants in Texas, with a focus on startup and shutdown events. The dataset includes tables summarizing startup and shutdown durations as well as nitrogen oxide (NOx) emission factors during these events, and compares these emission factors with those observed during all other operating phases (referred to here as “steady-state operation”). The dataset is derived using the U.S. Environmental Protection Agency (EPA)’s Clean Air Markets Program Data (CAMPD). Historical hourly data from 2015–2024, including electricity generation, heat input, and NOx emission factors, are used for natural gas combined cycle units, combustion turbine units, and steam turbine units in Texas. This work was authored by the National Laboratory of the Rockies, operated by the Alliance for Energy Innovation, LLC, for the U.S Department of Energy (DOE) under contract no. DE-AC36-08GO28308. Funding was provided by the U.S. Department of Energy as part of its Grid Modernization Laboratory Consortium, a strategic partnership between DOE and the national laboratories to bring together leading experts, technologies, and resources to collaborate on the goal of modernizing the nation’s grid. The views expressed in the dataset do not necessarily represent the views of the DOE or the U.S. Government.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual sensing-enabled digital twin framework for real-time monitoring of nuclear systems leveraging deep neural operators

Abstract Real-time monitoring is a foundation of nuclear digital twin technology, crucial for detecting material degradation and maintaining nuclear system integrity. Traditional physical sensor systems face limitations, particularly in measuring critical parameters in hard-to-reach or harsh environments, often resulting in incomplete data coverage. Machine learning-driven virtual sensors offer a transformative solution by complementing physical sensors in monitoring critical degradation indicators. This paper introduces the use of Deep Operator Networks (DeepONet) to predict key thermal-hydraulic parameters in the hot leg of pressurized water reactor. DeepONet acts as a virtual sensor, mapping operational inputs to spatially distributed system behaviors without requiring frequent retraining. Our results show that DeepONet achieves low mean squared and Relative L2 error, making predictions 1400 times faster than traditional CFD simulations . These characteristics enable DeepONet to function as a real-time virtual sensor, synchronizing with the physical system to track degradation conditions and provide insights within the digital twin framework for nuclear systems.

Hossain, Raisa↗

Point-of-use filtration units as drinking water distribution system sentinels

Abstract Municipal drinking water distribution systems (DWDSs) and associated premise plumbing (PP) systems are vulnerable to proliferation of opportunistic pathogens, even when chemical disinfection residuals are present, thus presenting a public health risk. Monitoring the structure of microbial communities of drinking water is challenging because of limited continuous access to faucets, pipes, and storage tanks. We propose a scalable household sampling method, which uses spent activated carbon and reverse osmosis (RO) membrane point-of-use (POU) filters to evaluate mid- to long-term occurrence of microorganisms in PP systems that are relevant to consumer exposure. As a proof of concept, POU filter microbiomes were collected from four different locations and analyzed with 16S rRNA gene amplicon sequencing. The analyses revealed distinct microbial communities, with occasional detection of potential pathogens. The findings highlight the importance of local, and if possible, continuous monitoring within and across distribution systems. The continuous operation of POU filters offers an advantage in capturing species that may be missed by instantaneous sampling methods. We suggest that water utilities, public institutions, and regulatory agencies take advantage of end-of-life POU filters for microbial monitoring. This approach can be easily implemented to ensure drinking water safety, especially from microbes of emerging concerns; e.g., pathogenic Legionella and Mycobacterium species.

42 ENGINEERING↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

FRISM (FReight Integrated Simulation Model) [SWR-24-40]

FRISM simulates day-to-day freight activities including end-consumer shopping, distribution channel, and carrier operation with e-commerce dynamics between passenger and freight travel. It outputs an assignment of different shipments to carriers and tour plans of the carriers' vehicles to transport shipments from their origins to their destinations.

Ugirumurera, Juliette↗

Off-line Tests of the DM1200 Thermal Catalytic Oxidation (TCO) Unit (Final Report)

The River Protection Project-Waste Treatment Plant (RPP-WTP) Low-Activity Waste (LAW) and High-Level Waste (HLW) feed streams are listed for a variety of hazardous organic compounds. The permitting basis for the WTP systems may necessitate the demonstration of minimum Destruction/Removal Efficiencies (DREs) of such species from any released emissions of up to 99.99%. Results from a previous study on the fate of hazardous organics in the melter itself indicated, not only that DREs for selected test compounds approached 99.99% only at extreme melter conditions, but also that organic compounds not originally present in the feed were actually produced in the melter, In order to ensure that the required DREs for hazardous organics are met, Thermal Catalytic Oxidation (TCO) units were therefore added to both the HLW and LAW off-gas treatment systems, The extent to which these species can be destroyed or removed in the TCO units is therefore an important issue in the design and permitting of the LAW and HLW off-gas treatment systems. A further consideration is that it would be desirable, if possible, to be able to achieve all of the required DRE across the TCO alone. If that is not the case, the DRE would be distributed across several unit operations, which may then become subject to additional operational constraints that may reduce process flexibility. Compliance with the DRE requirements on the basis of the TCO unit alone is also an approach that lends itself to periodic confirmation during operations, since the TCO is located at the back-end of the off-gas treatment system where radioactivity levels are lowest.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Persistent DynAMICS

Persistent DynAMICS is a lightweight software platform that enables distributed sensing systems to operate as a unified, responsive network. It integrates with existing sensors, data systems, and processing tools as an overlay, without requiring hardware replacement or increasing user burden. As data is collected, the system identifies situations that require additional attention and directs selected sensors to gather more information. For example, if a sensor detects an unusual condition along a pipeline, the system can task nearby sensors or different sensing modalities to confirm the event and focus data collection where it is needed. To support this, the platform forms temporary groups of sensors that work together to address specific objectives. Once complete, these groups are dissolved and resources are reassigned as needed. Communication is handled through an integrated messaging framework with client and server components, enabling reliable operation and data continuity even in low-bandwidth or intermittent connectivity environments.

97 MATHEMATICS AND COMPUTING↗

The 2024 National Hydropower Map

A visualization of the geospatial distribution and characteristics of operational hydropower plants in the United States in 2024.

13 HYDRO ENERGY↗