Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed predictive control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of plasma sheath on solar power satellite array

The structure of the plasma sheath and equilibrium voltage distribution of a high-power solar array governs various kinds of plasma-interaction phenomena and array losses. Sheath effects of a linearly-connected array are investigated for GEO. Although the array may be large, the thin-sheath-limit analysis may be invalid, necessitating numerical methods. Three-dimensional computer calculations show that potential barriers and over-lapping sheaths can occur, i.e., structures not predictable under the thin-sheath-limit analysis, but nevertheless controlling the distribution of plasma currents impacting on the array.

Parker, L. W.↗

Collaborative Distribution System Restoration Planning and Real-Time Dispatch Considering Behind-the-Meter DERs

Modern distribution systems are becoming more resilient against power outages thanks to the flexible generation capacity provided by the increasing integration of distributed energy resources (DERs). Compared to utility-scale DERs, which can be directly controlled by system operators, small-scale, behind-the-meter DERs are much more difficult to coordinate despite being the vast majority. Two major obstacles to the implementation of DERs for service restoration are the coordination of behind-the-meter DERs and the management of uncertainty. In this paper, a novel distribution system restoration strategy is proposed to overcome these two obstacles. The flexibility of be-hind-the-meter DERs is quantified and integrated into the restoration planning models within a hierarchical structure. The model predictive control technique is employed to enable adaptive restoration planning solution adjustments to accommodate fault scenarios and forecast errors. Besides, real-time power dispatch models are proposed to maintain power balance using available DER capability. Comprehensive integration of adaptive restoration planning schemes and real-time dispatch results are achieved through a collaborative restoration framework. Finally, the effectiveness of the proposed restoration strategy is verified through a modified IEEE 123-bus system and a real-world utility system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of the TRIGA IPR-R1 research reactor with the Serpent2/RINNOVO Nodal core analysis package

The Serpent2/RINNOVO nodal core analysis code system, a dedicated tool for modeling research reactors, has the capability to accurately predict important core physics parameters involved in the safety of reactor operation, such as various reactivity coefficients, control rod and bank worths including the shutdown margin, power distributions as well as local neutron flux predictions at various core locations of high importance, e.g., at irradiation rigs. In this work, a hexagonal model of the unrodded initial core of the Brazilian IPR-R1 Mark I type TRIGA nuclear reactor has been created using the Serpent2/RINNOVO code system. The choice of employing a hexagonal core geometry representation has mainly been made to facilitate subsequent fuel shuffling operations and core follow calculations of this reactor. Numerical results in terms of the core eigenvalue and the assembly power distribution have then been compared against corresponding full core Serpent2 results to prove feasibility of using the Serpent2/RINNOVO code system for modeling small and highly heterogeneous TRIGA reactors. Overall, RINNOVO predicts the power distribution very accurately but the eigenvalue error still remains quite large. In light of being the very first evaluation of a TRIGA reactor with the RINNOVO nodal core simulator, these results are also considered to be very preliminary. Improved accuracy is expected by incorporating a proper methodology in the current code system for computing discontinuity factors for multi-assembly configurations. Furthermore, improved results are expected by increasing the number of energy groups used by RINNOVO in these core calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Open-loop nanosecond-synchronization for wideband satellite communications

A synchronization technique for use with an onboard processing satellite communication system is discussed. The satellite oscillator is used both as the system time reference and as the frequency source for all downlink carriers and data clocks. Downlink timing is established at each system earth terminal through a combination of carrier and data-clock tracking and a downlink timing epoch signal consisting of one bit per TDMA data burst. Uplink timing is established by an open-loop range prediction process using precision ephemerides calculated and distributed by the central control station. Overall timing accuracy of the uplink signal at the satellite receiver of + or - 7 nanoseconds permits unambiguous identification of each data bit position in a 128 Mbps TDMA burst. This is accomplished by means of simple, inexpensive terminal hardware using available crystal oscillators for time/frequency references and digital synthesis techniques that may be implemented in digital LSI chips.

Holmes, W. M., Jr.↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ground based studies for the space processing of lead-tin-telluride

This paper summarizes the results of a series of studies dealing with crystal growth from the melt and in particular, the growth of the narrow bandgap semiconductor PbSnTe by the Bridgman technique. Theoretical calculations have shown that for low Prandtl number fluids such as semiconductors, convection has no effect on the temperature field in the melt but has a significant effect on the compositional field. They also show that convective flow will exist in a Bridgman growth system on earth, even in the 'thermally stable' configuration. Measurements of the specific heat have been made up to temperatures of 722 C. The thermal diffusivity has been measured up to 1010 C which includes values for the melt. The interdiffusion coefficients for PbTe and SnTe in the melt have been determined. A technique has been developed and tested which provides a vacuum tight quartz ampoule with electrical feedthroughs for interface demarcation studies during the Bridgman growth. Analysis of crystals grown has indicated that the PbSnTe system is solutally unstable and the distribution of SnTe in the crystal, after an anomalous first to freeze region, follows that predicted by Pfann for convection controlled growth. Studies of the amount of supercooling in PbSnTe indicate that this may explain an anomalous composition distribution in the first to freeze region of an unseeded growth.

Crouch, R. K.↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Domain-aware Control-oriented Neural Models for Autonomous Underwater Vehicles

Conventional physics-based modeling is a time-consuming bottleneck in control design for complex nonlinear systems like autonomous underwater vehicles (AUVs). In contrast, purely data-driven models, require a large number of observations and lack operational guarantees for safety-critical systems. Data-driven models leveraging available partially characterized dynamics have potential to provide reliable systems models in a typical data-limited scenario for high value complex systems, thereby avoiding months of expensive expert modeling time. In this work we explore this middle-ground between expert-modeled and pure data-driven modeling. We present control-oriented parametric models with varying levels of domain-awareness that exploit known system structure and prior physics knowledge to create constrained deep neural dynamical system models. We employ universal differential equations to construct data-driven blackbox and graybox representations of the AUV dynamics. In addition, we explore a hybrid formulation that explicitly models the residual error related to imperfect graybox models. We compare the prediction performance of the learned models for different distributions of initial conditions and control inputs to assess their suitability for control.

Shaw Cortez, Wenceslao E.↗

A numerical model including PID control of a multizone crystal growth furnace

This paper presents a 2D axisymmetric combined conduction and radiation model of a multizone crystal growth furnace. The model is based on a programmable multizone furnace (PMZF) designed and built at NASA Lewis Research Center for growing high quality semiconductor crystals. A novel feature of this model is a control algorithm which automatically adjusts the power in any number of independently controlled heaters to establish the desired crystal temperatures in the furnace model. The control algorithm eliminates the need for numerous trial and error runs previously required to obtain the same results. The finite element code, FIDAP, used to develop the furnace model, was modified to directly incorporate the control algorithm. This algorithm, which presently uses PID control, and the associated heat transfer model are briefly discussed. Together, they have been used to predict the heater power distributions for a variety of furnace configurations and desired temperature profiles. Examples are included to demonstrate the effectiveness of the PID controlled model in establishing isothermal, Bridgman, and other complicated temperature profies in the sample. Finally, an example is given to show how the algorithm can be used to change the desired profile with time according to a prescribed temperature-time evolution.

Panzarella, Charles H.↗

Autonomous control for Heat-Pipe microreactor using Data-Driven model predictive control

To enable a self-regulating capability for heat pipe (HP) microreactors, an anticipatory control strategy achieved via model predictive control (MPC) could proactively respond to potential disturbances and deviations in operating setpoints. This paper demonstrates data-driven methods for predicting the distribution and transient of temperatures and heat fluxes at selected components and regions in a 37-HP system, based on which the optimal control actions in response to changes in user-defined setpoints can be found. We present the development and validation of linear state-space model, feedfoward, and recurrent neural networks. Here, we compare the performance of MPCs with different modeling approaches in terms of following setpoints for temperatures and averaged output heat fluxes. The accuracies of the three data-driven models are similar, but the control actions initiated by neural-network-based MPC can better adapt to drastic changes in setpoints yet generate the smallest errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Model of Human and System Dynamics in Free Flight: Studies in Distributed Control Technologies

This paper presents a set of studies in full mission simulation and the development of a predictive computational model of human performance in control of complex airspace operations. NASA and the FAA have initiated programs of research and development to provide flight crew, airline operations and air traffic managers with automation aids to increase capacity in en route and terminal area to support the goals of safe, flexible, predictable and efficient operations. In support of these developments, we present a computational model to aid design that includes representation of multiple cognitive agents (both human operators and intelligent aiding systems). The demands of air traffic management require representation of many intelligent agents sharing world-models, coordinating action/intention, and scheduling goals and actions in a potentially unpredictable world of operations. The operator-model structure includes attention functions, action priority, and situation assessment. The cognitive model has been expanded to include working memory operations including retrieval from long-term store, and interference. The operator's activity structures have been developed to provide for anticipation (knowledge of the intention and action of remote operators), and to respond to failures of the system and other operators in the system in situation-specific paradigms. System stability and operator actions can be predicted by using the model. The model's predictive accuracy was verified using the full-mission simulation data of commercial flight deck operations with advanced air traffic management techniques.

Corker, Kevin M.↗

Dynamic-Phasor Model of Transformer Inrush Simulation for Unbalanced Distribution System

Abstract— Power system stability is a critical concern, with respect to the increasing distributed energy resources, microgrids, and emphasis on enhancing resiliency. For stability analysis and evaluation, modeling and simulation capabilities are important. In this paper, the authors’ previous work on modeling transformer inrush dynamics is improved with a new formulation of the key equation that converts the dynamic-phasor into real-time value. Simulation results in an electromechanical time-scale are compared with PSCAD results in an electromagnetic time-scale to demonstrate the improvement. The impact of simulation step size is discussed. A bug in PSCAD transformer setting that leads to incorrect magnetizing flux and current under Delta winding type is identified and reported. In addition, explanations and analysis are provided on two modeling techniques utilized since the previous work. This work is being incorporated into the next release of GridLAB-D. The improved transformer inrush calculation enables more accurate predictions of current amplitudes for analyzing the dynamics of distribution operation and control.

power transformers, power system simulation, satur↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Patterns and rates of soil movement and shallow failures across several small watersheds on the Seward Peninsula, Alaska

Abstract. Thawing permafrost can alter topography, ecosystems, and sediment and carbon fluxes, but predicting landscape evolution of permafrost-influenced watersheds in response to warming and/or hydrological changes remains an unsolved challenge. Sediment flux and slope instability in sloping saturated soils have been commonly predicted from topographic metrics (e.g., slope, drainage area). In addition to topographic factors, cohesion imparted by soil and vegetation and melting ground ice may also control spatial trends in slope stability, but the distribution of ground ice is poorly constrained and hard to predict. To address whether slope stability and surface displacements follow topographic-based predictions, we document recent drivers of permafrost sediment flux present on a landscape in western Alaska that include creep, solifluction, gullying, and catastrophic hillslope failures ranging in size from a few meters to tens of meters, and we find evidence of rapid and substantial landscape change on an annual timescale. We quantify the timing and rate of surface movements using a multi-pronged, multi-scalar dataset including aerial surveys, interannual GPS surveys, synthetic aperture radar interferometry (InSAR), and climate data. Despite clear visual evidence of downslope soil transport of solifluction lobes, we find that the interannual downslope surface displacement of these features does not outpace downslope displacement of soil in locations where lobes are absent (downslope movement means: 7 cm yr−1 for lobes over 2 years vs. 10 cm yr−1 in landscape positions without lobes over 1 year). Annual displacements do not appear related to slope, drainage area, or modeled total solar radiation but are likely related to soil thickness, and volumetric sediment fluxes are high compared to temperate landscapes of comparable bedrock lithology. Time series of InSAR displacements show accelerated movement in late summer, associated with intense rainfall and/or deep thaw. While mapped slope failures do cluster at slope–area thresholds, a simple slope stability model driven with hydraulic conductivities representative of throughflow in mineral and organic soil drastically overpredicts the occurrence of slope failures. This mismatch implies permafrost hillslopes have unaccounted-for cohesion and/or throughflow pathways, perhaps modulated by vegetation, which stabilize slopes against high rainfall. Our results highlight the breadth and complexity of soil transport processes in Arctic landscapes and demonstrate the utility of using a range of synergistic data collection methods to observe multiple scales of landscape change, which can aid in predicting periglacial landscape evolution.

54 ENVIRONMENTAL SCIENCES↗

Voltage Violation Prediction in Unobservable Distribution Systems

Recently, distributed energy resources (DERs) such as photovoltaic (PV) systems have garnered significant attention due to their economic and environmental benefits. However, DERs can also pose new technical challenges to distribution system operation including under/over voltage issues. In this regard, voltage violation prediction (VVP) becomes an essential component of system operation as it enables proactive control strategies. Unfortunately, classical voltage monitoring techniques assume full availability of state measurements across all nodes in the system. In real-world scenarios, distribution systems are limited with few measurement devices, rendering the system unobservable. Therefore, this paper proposes a new Bayesian matrix completion (BMC) based VVP technique that accurately predicts the probability of nodal voltage violations in unobservable (and unbalanced) distribution systems. The proposed approach is tested via simulations on the IEEE 37 test system. Results show that the proposed method offers over 90% violation prediction accuracy with as low as 50% fraction of available data.

Abujubbeh, Mohammad↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗